At least 523 records · Page 29

Molecular Tuning of Ether Cosolvent Chemistry for High-Voltage Sodium-Ion Batteries

Ethers as electrolyte cosolvents in sodium-ion batteries (SIBs) provide favorable Na + solvation and interfacial properties, but their low oxidative stability limits their use in high-voltage SIBs. Herein, we address this limitation via molecular tuning of ether cosolvents for high-voltage (4.2 V) hard carbon || NaNi 0.33 Fe 0.33 Mn 0.33 O 2 full cells. Tetrahydropyran (THP) is functionalized with a nitrile group to form tetrahydropyran-4-carbonitrile (THPCN). To delineate the effect of nitrile functionalization and benchmark ether against a conventional carbonate, THP, THPCN, and diethyl carbonate (DEC) are evaluated as cosolvents with ethylene carbonate. Nitrile functionalization lowers the HOMO energy of the ether, extends the electrolyte stability window, and alters Na⁺ solvation. Spectroscopic techniques and molecular dynamics simulations reveal that THPCN exhibits predominantly aggregate-dominated solvation (95.1 %) with weakened Na + -solvent interactions, producing the most anion-rich environment relative to DEC and THP cosolvents. THPCN-modified solvation promotes the formation of highly conductive, fluorine-enriched interphases that suppress parasitic reactions. Pouch full cells with THPCN sustained ~ 600 cycles at 4.2 V, outperforming THP and DEC. Operando gas analysis reveals that THPCN reduces CO 2 generation by 45% and H 2 generation by 30% relative to THP. Furthermore, the findings demonstrate nitrile functionalization as a molecular design strategy to stabilize ethers and enable high-voltage SIBs.

25 ENERGY STORAGE↗

In situ quantification of interphasial chemistry in Li-ion battery

The solid-electrolyte-interphase (SEI) is probably the least understood component in Li-ion batteries. Considerable effort has been put in the understanding of its formation and electrochemistry under realistic battery conditions, but mechanistic insights have been inferred mostly indirectly. Here we show the formation of the SEI between a graphite anode and a carbonate electrolyte using combined atomic scale microscopy and in-situ and operando techniques. In particular, we weigh the graphitic anode during its initial lithiation process with electrochemical quartz crystal microbalance, which unequivocally identifies lithium fluoride (LiF) and lithium alkylcarbonates as the main chemical components at different potentials. In-situ gas analysis confirmed the preferential reduction of cyclic over acyclic carbonate molecules, making its reduction product the major component in SEI. We find that SEI formation starts at graphite edge-sites with dimerization of solvated Li + -intercalation between graphite-layers. As a result, we also show that this lithium salt, at least in its nascent form, is re-oxidizable, despite the general belief that an SEI is electrochemically inert and its formation irreversible.

25 ENERGY STORAGE↗

The thermally induced decarboxylation mechanism of a mixed-oxidation state carboxylate-based iron metal–organic framework

Investigations into a thermally generated decarboxylation mechanism for metal site activation and the generation of mesopores in a carboxylate iron-based MOF, PCN-250, have been conducted. PCN-250 exhibits an interesting oxidation state change during thermal treatment under inert atmospheres or vacuum conditions, transitioning from an Fe(III)3 cluster to a Fe(II)Fe(III) 2 cluster. To probe this redox event and discern a mechanism of activation, a combination of thermogravimetric analysis, gas sorption, scanning electron microscopy, 57 Fe Mössbauer spectroscopy, gas chromatography-mass spectrometry, and X-ray diffraction studies were conducted. The results suggest that the iron-site activation occurs due to ligand decarboxylation above 200 °C. This is also consistent with the generation of a missing cluster mesoporous defect in the framework. The resulting mesoporous PCN-250 maintains high thermal stability, preserving crystallinity after multiple consecutive high-temperature regeneration cycles. Additionally, the thermally reduced PCN-250 shows improvements in the total uptake capacity of methane and CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hybrid feature selection approach for power transformer fault diagnosis based on support vector machine and genetic algorithm

To further improve fault diagnosis accuracy, a new hybrid feature selection approach combined with a genetic algorithm (GA) and support vector machine (SVM) is presented in this study. Adaptive synthetic technique and arctangent transformation method are adopted to improve the statistical property of the training set (IEC TC10 dataset). Five filter methods based on different evaluation metrics are employed to rank 48 input features derived from dissolved gas analysis (DGA). Then, feature combination methods are applied to aggregate feature ranks and form a lower-dimension candidate feature subset. The GA-SVM model is implemented to optimise parameters and select optimal feature subsets. 5-fold cross-validation accuracy of the GA-SVM is used to evaluate fault diagnosis capability of feature subsets and finally, a novel subset is determined as the optimal feature subset. Accuracy comparison manifests the superiority of the optimal feature subsets over that of conventional approaches. Besides, generalisation and robustness of the optimal subset are validated by testing DGA samples from the local power utility. Results indicate that the optimal feature subset obtained by the proposed method can significantly improve the accuracies of power transformer fault diagnosis.

Kari, Tusongjiang↗

Outgassing and degradation of polyimide induced by swift heavy ion irradiation at cryogenic temperature

Polyimide foils were irradiated with energetic Kr (740 MeV) and Pb (890 MeV) ions at cryogenic temperature (12 K). Beam-induced degradation processes were monitored by residual gas analysis and online infrared spectroscopy. The outgassing components observed at low irradiation temperatures differ in quantity but are similar in mass distribution to those identified at room temperature exposure. Besides CO as major volatile fragment, a significant contribution of short hydrocarbons like C{sub 2}H{sub x} is released. In situ infrared spectroscopy indicates accumulation of CO and CO{sub 2} molecules at 12 K in the foils. During heat-up cycles, most of these frozen gases become mobile and outgas at a temperature between 35 and 55 K. The study is motivated by the application of polyimide foils as insulating material in high radiation environment of the future accelerator facility for antiproton and ion research (FAIR).

36 MATERIALS SCIENCE↗

Laser power meters as an X-ray power diagnostic for LCLS-II

For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine the absolute X-ray power at the endstations. Here, thermopile power meters, which measure average power, and have been chosen primarily for their compatibility with the high repetition rates at LCLS-II, are evaluated. Here, a number of characteristics in the soft X-ray range are presented including linearity, calibrations conducted with a photodiode and a gas monitor detector as well as ultra-high-vacuum compatibility tests using residual gas analysis. The application of these power meters for LCLS-II and other X-ray FEL sources is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Heat Transfer from Glass Melt to Cold Cap: Gas Evolution and Foaming

In electric melters, the conversion heat is transferred through the foam layer at the cold cap bottom. Understanding cold cap foaming is thus important for enhancing the efficiency of both commercial and waste glass melters as well as for the development of advanced batch-to-glass conversion models. Observing foam behavior “in-situ” is still impossible, i.e., viewing directly in glass melters. To investigate the feed foaming behavior in laboratory conditions, we employed the feed volume expansion test, evolved gas analysis, and thermogravimetry. Combining these techniques helps assess the cold cap bottom temperature that directly influences the temperature gradient at the melt/cold cap interface, and thus the rate of melting. We also discuss the behavior of cavities formed by coalescing primary foam bubbles and ascending secondary bubbles.

Hrma, Pavel R.↗

Nucleation and growth of molybdenum disulfide grown by thermal atomic layer deposition on metal oxides

To enable greater control over thermal atomic layer deposition (ALD) of molybdenum disulfide (MoS 2 ), here we report studies of the reactions of molybdenum hexafluoride (MoF 6 ) and hydrogen sulfide (H 2 S) with metal oxide substrates from nucleation to few-layer films. In situ quartz crystal microbalance experiments performed at 150, 200, and 250 °C revealed temperature-dependent nucleation behavior of the MoF 6 precursor, which is attributed to variations in surface hydroxyl concentration with temperature. In situ Fourier transform infrared spectroscopy coupled with ex situ x-ray photoelectron spectroscopy (XPS) indicated the presence of molybdenum oxide and molybdenum oxyfluoride species during nucleation. Density functional theory calculations additionally support the formation of these species as well as predicted metal oxide to fluoride conversion. Residual gas analysis revealed reaction by-products, and the combined experimental and computational results provided insights into proposed nucleation surface reactions. With additional ALD cycles, Fourier transform infrared spectroscopy indicated steady film growth after ~13 cycles at 200 °C. XPS revealed that higher deposition temperatures resulted in a higher fraction of MoS 2 within the films. Deposition temperature was found to play an important role in film morphology with amorphous films obtained at 200 °C and below, while layered films with vertical platelets were observed at 250 °C. Finally, these results provide an improved understanding of MoS 2 nucleation, which can guide surface preparation for the deposition of few-layer films and advance MoS 2 toward integration into device manufacturing.

36 MATERIALS SCIENCE↗

Conversion of solid carbonaceous fuels in a fluidized bed fuel cell

A fluidized bed direct carbon fuel cell was employed to achieve direct conversion of solid fuels into electricity. Power was generated from pulverized Lower Kittanning (bituminous) coal, synthetic carbon, and biomass in a single process step. Current-voltage characteristics exhibited typical fuel cell behavior. Fluidization in flowing CO{sub 2} overcomes the difficulty of attaining solid fuel-to-anode contact and generates CO in situ via the Boudouard reaction. A mechanistic reaction pathway is proposed for anodic oxidation of the solid fuel. Conversion was verified by gas analysis of oxidation products in the flue stream and by oxygen mass balance.

20 FOSSIL-FUELED POWER PLANTS↗

Electrochemical Investigation of Moisture Byproducts in Molten Calcium Chloride

Residual water in molten CaCl 2 reacts to form different byproducts, such as HCl, which can impact the corrosivity of the salt and efficiency of electrochemical operations, such as electrolytic oxide reduction and electrorefining. The ability to detect and quantify these byproducts electrochemically can provide feedback on the efficacy of vacuum drying and other purification methods, as well as the impact of these byproducts on process operations. An electrochemical signal’s association with the production of H 2 is verified and characterized using cyclic voltammetry (CV) and residual gas analysis. CV estimated a 2-electron exchange process associated with H 2 production. CV detected trace quantities of an oxidized species containing hydrogen in the salt on the order of 10 ppm. Different salt handling methods were compared for their impact on the hydrogen electrochemical signal. It was found that 30 min of exposure of CaCl 2 in a beaker to low-humidity air (<20%) had minimal impact on the H 2 production signal.

Electrochemistry↗

AmeriFlux US-Bsg Burns Sagebrush

This is the AmeriFlux version of the carbon flux data for the site US-Bsg Burns Sagebrush. Site Description - The site was established in 2012 and is part of a NOAA observation network for high precision measurements of carbon dioxide concentrations. It is located about 60 km southwest of Burns, Oregon in the Oregon High Desert. The vegetation in this area is dominated by sagebrush. The sampling inlets are at the heights of 18.5, 28.5, and 38.5 m. Gas analysis is performed with a Picarro 2302 Cavity Ringdown Spectrometer and a Li-Cor 7200 enclosed path IRGA. The tower is also equipped with a set of meteorological instruments, including an HMP sensor, radiation sensors (incoming and diffuse PAR, Net radiometer), and a CSAT3 sonic anemometer. This site is also part of the PhenoCam network operated by Harvard University and the University of New Hampshire.

Still, Chris↗

Evaluation Of Methods To Measure Hydrogen Generation Rate In A Shielded Cell Environment And A Method Recommendation

The purpose of this document is to describe the current state of the art for determination of hydrogen generation rates of radioactive slurries and solutions to provide a basis for design, fabrication, testing, and implementation of a measurement method for Hydrogen Generation Rate (HGR) during qualification of waste feeds for the Hanford Waste Treatment and Immobilization Plant (WTP). The HGR measurement will be performed on samples of the Low Activity Waste (LAW) and High Level Waste (HLW) staged waste feeds for the WTP as well as on samples from selected unit operations testing during the qualification program. SRNL has performed a review of techniques utilized to measure HGR of high level radioactive waste slurries, evaluated the Hanford 222-S Laboratory method for measurement of hydrogen, and reviewed the hydrogen generation rate models for Hanford waste.Based on the literature review, method evaluation, and SRNL experience with measuring hydrogen generation rate, SRNL recommends that a continuous flow system with online gas analysis be used as the HGR measurement method during waste qualification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methodologies for Reservoir Characterization Using Fluid Inclusion Gas Chemistry

The purpose of this project was to: 1) evaluate the relationship between geothermal fluid processes and the compositions of the fluid inclusion gases trapped in the reservoir rocks; and 2) develop methodologies for interpreting fluid inclusion gas data in terms of the chemical, thermal and hydrological properties of geothermal reservoirs. Phase 1 of this project was designed to conduct the following: 1) model the effects of boiling, condensation, conductive cooling and mixing on selected gaseous species; using fluid compositions obtained from geothermal wells, 2) evaluate, using quantitative analyses provided by New Mexico Tech (NMT), how these processes are recorded by fluid inclusions trapped in individual crystals; and 3) determine if the results obtained on individual crystals can be applied to the bulk fluid inclusion analyses determined by Fluid Inclusion Technology (FIT). Our initial studies however, suggested that numerical modeling of the data would be premature. We observed that the gas compositions, determined on bulk and individual samples were not the same as those discharged by the geothermal wells. Gases discharged from geothermal wells are CO 2 -rich and contain low concentrations of light gases (i.e. H 2 , He, N, Ar, CH4). In contrast many of our samples displayed enrichments in these light gases. Efforts were initiated to evaluate the reasons for the observed gas distributions. As a first step, we examined the potential importance of different reservoir processes using a variety of commonly employed gas ratios (e.g. Giggenbach plots). The second technical target was the development of interpretational methodologies. We have develop methodologies for the interpretation of fluid inclusion gas data, based on the results of Phase 1, geologic interpretation of fluid inclusion data, and integration of the data. These methodologies can be used in conjunction with the relevant geological and hydrological information on the system to create fluid models for the system. The hope is that the methodologies developed will allow bulk fluid inclusion gas analysis to be a useful tool for estimating relative temperatures, identifying the sources and origins of the geothermal fluids, and developing conceptual models that can be used to help target areas of enhanced permeability.

15 GEOTHERMAL ENERGY↗

H2FIRST Hydrogen Contaminant Detector Task: Requirements Document and Market Survey

The rollout of hydrogen fueling stations, and the fuel cell electric vehicles (FCEV) they support, requires the assurance of high quality hydrogen at the dispensing point. Automotive fuel cells are sensitive to a number of chemicals that can be introduced into the dispensed fuel at multiple points. Quality assurance and quality control methods are employed by the industry to ensure product quality, but they are not completely comprehensive and can fail at various points in the hydrogen pathway from production to dispensing. This reality leaves open the possibility of a station unknowingly dispensing harmful contaminants to a FCEV which, depending on the contaminant, may not be discovered until the FCEV is irreparably damaged. This situation is unacceptable. A hydrogen contaminant detector (HCD), defined as a combination of a gas analyzer and the components necessary for fuel stream integration, installed at hydrogen stations is one method for preventing poor quality gas from reaching an FCEV. This document identifies the characteristics required of such a device by industry and compares those requirements with the current state of commercially available gas analysis technology.

30 DIRECT ENERGY CONVERSION↗

Compendium of Phase-I Mini-SHINE Experiments

Argonne National Laboratory is assisting SHINE Medical Technologies in their efforts to develop the technology to become a domestic Mo-99 producer using low-enriched uranium (LEU). Mini-SHINE experiments are being performed with the high-current electron linear accelerator (linac) at Argonne. The target solution is a 90-150 g-U/L LEU uranyl sulfate at pH 1. In Phase 1, the convertor was tantalum with a maximum beam power on the convertor of 10 kW, and the target solution was limited to 5 L. This configuration generated a peak fission power density of 0.05 W/mL. Nine experiments were performed between February and October 2015. Results are reported and discussed for each experiment regarding the off-gas analysis system, the sampling and Mo-recovery operation, and the Mo-product concentration and purification system. In Phase 2, the convertor will be depleted uranium; beam power will increase to 20 kW; and the solution volume will be 18 L. This configuration will generate a fission power density of up to 1 W/mL.

43 PARTICLE ACCELERATORS↗

Technical basis for inner container leak detection sensitivity goals in 3013 DE surveillance

Helium leak checking of 3013 inner container lids is under consideration for addition to DE Surveillance tasks as an improved means to detect any through-wall flaws that may have formed during storage. This white paper evaluates whether leak checking at DE could replace and improve upon the current method of comparing gas compositions and pressures within the inner and outer containers. We have used viscous and molecular flow equations in ANSI N14.5 to calculate what the measured standard helium leak rate would be for hypothetical leaks of three different sizes. For comparison, we have also calculated the effects on gas composition and pressure differences as a function of pre-DE storage time for the same three leak sizes, using molecular and viscous flow equations as well as diffusion equations to predict the relevant gas transport. For a hypothetical leak that would be measured at 1x10 -7 std cc/sec, likely an achievable sensitivity using helium leak checking at DE, the calculations predict no measurable effect on pressure difference or gas composition as measured by DE gas analysis. We also calculate that it would take over 200 years for water vapor to diffuse through a 10 -7 std cc/sec leak enough to raise the RH outer container to half the RH value in the inner container. A leak 100 times larger, which would be measured at 1x10 -5 std cc/sec, the same water vapor diffusion would take at least 14 years. Our conclusion is that helium leak checking will be useful even at a sensitivity of 1x10 -5 std cc/sec, and a significant improvement over current DE methods at a sensitivity of 1x10 -7 std cc/sec.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Decomposition Model Development of EN-7 and EN-8 Polyurethane Elastomers.

Thermogravimetric analysis - gas chromatography/mass spectrometry (TGA- GC/MS) experiments were performed on EN-7 and EN-8, analyzed, and reported in [1] . This SAND report derives and describes pyrolytic thermal decomposition models for use in predicting the responses of EN-7 and EN-8 in an abnormal thermal environment.

36 MATERIALS SCIENCE↗

Helium Sample Loop Monitoring System (Final Report)

C-CDE was requested to assist with a gas analysis system for the Northstar helium flow loop experimental design. The system was requested due to concerns that the lubricating oils in the blower unit could potentially contaminate the helium loop piping system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗