Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Vibroacoustic Response of the NASA ACTS Spacecraft Antenna to Launch Acoustic Excitation

The Advanced Communications Technology Satellite was an experimental NASA satellite launched from the Space Shuttle Discovery. As part of the ground test program, the satellite s large, parabolic reflector antennas were exposed to a reverberant acoustic loading to simulate the launch acoustics in the Shuttle payload bay. This paper describes the modelling and analysis of the dynamic response of these large, composite spacecraft antenna structure subjected to a diffuse acoustic field excitation. Due to the broad frequency range of the excitation, different models were created to make predictions in the various frequency regimes of interest: a statistical energy analysis (SEA) model to capture the high frequency response and a hybrid finite element-statistical energy (hybrid FE-SEA) model for the low to mid-frequency responses. The strengths and limitations of each of the analytical techniques are discussed. The predictions are then compared to the measured acoustic test data and to a boundary element (BEM) model to evaluate the performance of the hybrid techniques.

Larko, Jeffrey M.↗

FREQ: A computational package for multivariable system loop-shaping procedures

Many approaches in the field of linear, multivariable time-invariant systems analysis and controller synthesis employ loop-sharing procedures wherein design parameters are chosen to shape frequency-response singular value plots of selected transfer matrices. A software package, FREQ, is documented for computing within on unified framework many of the most used multivariable transfer matrices for both continuous and discrete systems. The matrices are evaluated at user-selected frequency-response values, and singular values against frequency. Example computations are presented to demonstrate the use of the FREQ code.

Giesy, Daniel P.↗

Flight testing and frequency domain analysis for rotorcraft handling qualities characteristics

A demonstration of frequency domain flight testing techniques and analyses was performed on a U.S. Army OH-58D helicopter in support of the OH-58D Airworthiness and Flight Characteristics Evaluation and the Army's development and ongoing review of Aeronautical Design Standard 33C, Handling Qualities Requirements for Military Rotorcraft. Hover and forward flight (60 knots) tests were conducted in 1 flight hour by Army experimental test pilots. Further processing of the hover data generated a complete database of velocity, angular rate, and acceleration frequency responses to control inputs. A joint effort was then undertaken by the Airworthiness Qualification Test Directorate (AQTD) and the U.S. Army Aeroflightdynamics Directorate (AFDD) to derive handling qualities information from the frequency response database. A significant amount of information could be extracted from the frequency domain database using a variety of approaches. This report documents numerous results that have been obtained from the simple frequency domain tests; in many areas, these results provide more insight into the aircraft dynamics that affect handling qualities than to traditional flight tests. The handling qualities results include ADS-33C bandwidth and phase delay calculations, vibration spectral determinations, transfer function models to examine single axis results, and a six degree of freedom fully coupled state space model. The ability of this model to accurately predict aircraft responses was verified using data from pulse inputs. This report also documents the frequency-sweep flight test technique and data analysis used to support the tests.

Ham, Johnnie A.↗

High-energy radiographic imaging performance of LYSO

Here, a comprehensive comparison of the dominant sources of radiation-induced blur for radiographic imaging system performance is made. End-point energies of 6, 10, 15, and 20 MeV bremsstrahlung photon radiation produced at the Los Alamos National Laboratory Microtron facility were used to examine the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO:Ce) scintillators 3, 5 and 10 mm thick. The system resolution was measured and compared between the various end-point energies and scintillator thicknesses. Contrary to expectations, it is found that there was only a minor dependence of system resolution on scintillator thickness or beam end-point energy. This indicates that increased scintillator thickness does not have a dramatic effect on system performance. The data are then compared to Geant4 simulations to assess contributions to the system performance through the examination of modulation transfer functions. It was determined that the low-frequency response of the system is dominated by the radiation-induced signal, while the higher-frequency response of the system is dominated by the optical imaging of the scintillation emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of piezoelectric foil for flow diagnostics

A laboratory investigation was conducted to characterize two piezoelectric-film sensor configurations, a rigidly mounted sensor and a sensor mounted over an air cavity. The sensors are evaluated for sensitivity and frequency response, and methods to optimize data are presented. The cavity-mounted sensor exhibited a superior frequency response and was more sensitive to normal pressure fluctuations and less sensitive to vibrations through the structure. Both configurations were sensitive to large-scale structural vibrations. Flight-test data are shown for cavity-mounted sensors, illustrating practical aspects to consider when designing sensors for application in such harsh environments. The relation of the data to skin friction and maximum shear stress, transition detection, and turbulent viscous layers is derived through analysis of the flight data.

Carraway, Debra L.↗

Measurements With a Split-Fiber Probe in Complex Unsteady Flows

A split-fiber probe was used to acquire unsteady data in a research compressor. A calibration method was devised for a split-fiber probe, and a new algorithm was developed to decompose split-fiber probe signals into velocity magnitude and direction. The algorithm is based on the minimum value of a merit function that is built over the entire range of flow velocities for which the probe was calibrated. The split-fiber probe performance and signal decomposition was first verified in a free-jet facility by comparing the data from three thermo-anemometric probes, namely a single-wire, a single-fiber, and the split-fiber probe. All three probes performed extremely well as far as the velocity magnitude was concerned. However, there are differences in the peak values of measured velocity unsteadiness in the jet shear layer. The single-wire probe indicates the highest unsteadiness level, followed closely by the split-fiber probe. The single-fiber probe indicates a noticeably lower level of velocity unsteadiness. Experiments in the NASA Low Speed Axial Compressor facility revealed similar results. The mean velocities agreed well, and differences in the velocity unsteadiness are similar to the case of a free jet. A reason for these discrepancies is in the different frequency response characteristics of probes used. It follows that the single-fiber probe has the slowest frequency response. In summary, the split-fiber probe worked reliably during the entire program. The acquired data averaged in time followed closely data acquired by conventional pneumatic probes.

Lepicovsky, Jan↗

Pyrotechnic shock measurement and data analysis requirements

A study of laboratory measurement and analysis of pyrotechnic shock prompted by a discrepancy in preliminary Mariner Jupiter/Saturn shock test data is reported. It is shown that before generating shock response plots from any recorded pyrotechnic event, a complete review of each instrumentation and analysis system must be made. In addition, the frequency response capability of the tape recorder used should be as high as possible; the discrepancies in the above data were due to inadequate frequency response in the FM tape recorders. The slew rate of all conditioning amplifiers and input converters must be high enough to prevent signal distortion at maximum input voltage; amplifier ranges should be selected so that the input pulse is approximately 50% of full scale; the Bessel response type should be chosen for digital shock analysis if antialiasing filters are employed; and transducer selection must consider maximum acceleration limit, mounted resonance frequency, flat clean mounting surfaces, base bending sensitivity, and proper torque.

Albers, L.↗

High frequency electromagnetic response of the moon

It is shown that the contribution of higher harmonics to the lunar transfer functions for the tangential components of the surface magnetic field is significant at frequencies greater than 0.01 Hz. The inclusion of the higher harmonics shows that there are two distinct transfer functions corresponding to the components of the tangential surface magnetic field perpendicular and parallel to the direction of the wave vector of the external disturbance forcing the lunar induction. The dependences of these transfer functions on frequency and location are determined. The effects of the higher harmonics can: (1) account for a hitherto unexplained feature in the Apollo 12-Explorer 35 transfer functions, namely the rolloff at high frequencies; and (2) offer a possible explanation for the frequency dependence of the difference between the transfer functions for the two orthogonal components of the surface magnetic field. The harmonic response of a simple current layer model of the moon is derived.

Schubert, G.↗

A closed-loop phase-locked interferometer for wide bandwidth position sensing

This article describes a position sensitive interferometer with closed-loop control of the reference mirror. A calibrated nanopositioner is used to lock the interferometer phase to the most sensitive point in the interferogram. In this configuration, large low-frequency movements of the sensor mirror can be detected from the control signal applied to the nanopositioner and high-frequency short-range signals can be measured directly from the photodiode. It is demonstrated that these two signals are complementary and can be summed to find the total displacement. The resulting interferometer has a number of desirable characteristics: it is optically simple, does not require polarization or modulation to detect the direction of motion, does not require fringe-counting or interpolation electronics, and has a bandwidth equal to that of the photodiode. Experimental results demonstrate the frequency response analysis of a high-speed positioning stage. The proposed instrument is ideal for measuring the frequency response of nanopositioners, electro-optical components, MEMs devices, ultrasonic devices, and sensors such as surface acoustic wave detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pyrotechnic shock measurement and data analysis requirements

An investigation is described into the laboratory measurement and analysis of pyrotechnic shock which was prompted at JPL when two separate facilities generated discrepant pyrotechnic shock data while testing Mariner Jupiter/Saturn 1977 spacecraft hardware. Both of the testing facilities were surveyed. The only difference noted was in the FM tape recorders used to record the data. One facility used a tape recorder operating at 60 in./sec with a frequency response of 20 kHz; the other used a tape recorder operating at 120 in./sec with a frequency response of 80 kHz. The accelerometers, cables, charge amplifiers, and mechanical setups were identical.

Albers, L.↗

Operation and design considerations for unsteady data acquisition with PC-based systems in high Reynolds number hypersonic flowfields

Operation and design considerations for personal-computer-based data acquisition are analyzed, and a system is created that is portable, inexpensive, and capable of high-frequency response. This system performed well when given an extensive analysis of the characteristics of the radio-frequency noise in the test environment. The system architecture is well-suited for support of high-frequency data acquisition from both pressure transducers and high-frequency-response thermocouple gauges. As configured, the system provides a data resolution of approximately 0.09 psia and 0.56 F. Considering the constraints placed upon this design, this data resolution is acceptable. The $5000 budget did require use of an existing PC and rental of signal-conditioning equipment.

Flanagan, M. J., Jr.↗

Sub-Nyquist Distortions in Sampled One- and Two-Dimensional Signals Studied

Hardware testing frequently involves the acquisition of waveform and instrumentation signals, which are often recorded on waveform recorders, oscillographs, and video recorders. Years ago, the waveforms were viewed as analog records, as drawn by a paper strip chart pen or electron beam on a cathode ray tube screen. One of the problems in the past was that the analog electronics may not have been able to accurately display the full amplitude of a signal if the real-time signals exceeded the frequency response bandwidth of the recording device. The advent of digital oscilloscopes, waveform recorders, and video frame-grabbers solved many of the frequency response problems, though not all. A restriction on digital waveform acquisition is well known by people in the instrumentation field. Put simply, the sampling frequency must be at least twice the frequency of any signal to be sampled, or vice versa; the signals must be filtered so that none of the signal frequencies are higher than one-half the sample rate (the Nyquist Limit). Then, per Shannon's Sampling Theorem (1949, ref. 1), any sampled signal can be reconstructed for viewing on a display device. If any signals exceed the Nyquist frequency limit, error signals called aliases occur in the output display.

Williams, Glenn L.↗

Nanoscale Compositional and Strain Gradients Enable High‐Speed and Amplitude‐Resolved Pyroelectric Sensing

The frequency response of pyroelectric sensors is fundamentally governed by thermal time constant (τth, determined by thermal mass and thermal conductance) and electrical impedance arising from film capacitance and readout circuit. Conventional bulk LiTaO3 detectors are optimized for high responsivity at low modulation frequencies (0.1-10 Hz), possessing a large τth that thermally averages rapid temperature oscillations at elevated modulation frequencies, limiting fidelity in resolving dynamic varying thermal signals. Here, compositional and strain gradients are introduced into 100-nm-thick relaxor-ferroelectric films reducing τth to ≈2 µs and producing built-in potentials (≈1.45 V or 145 kV cm-1) that enhance the pyroelectric coefficient and suppress the dielectric constant. This enables complementary dual-mode operation by enhancing current-mode electrical responsivity and improving the voltage-mode figure of merit - advantageous for superior temperature resolution (ΔTmin ≈ 30 µK). The responsivity peak shifts to near 1 kHz (>2500-times higher than conventional bulk sensors), with measurable responsivity extending to a carrier frequency of 100 kHz and amplitude-resolved detection at modulation frequencies up to 15 kHz. These results establish nanoscale internal-field engineering can reshape electro-thermal trade-off in pyroelectric thin films toward zero-bias, high-thermal-sensitivity, and amplitude-resolved thermal sensing across a wide frequency bandwidth.

Lin, Ching‐Che↗

Effect of backscattering on nonlinear distortions of the scale factor of a laser gyro with a rectangular bias

We report the results of measurements of nonlinear scale factor corrections, resulting from the backscattering effect in a laser gyro with a rectangular bias. It is shown that taking conservative and dissipative backscattering components into account allows one to obtain analytical relationships that adequately describe the frequency response of a laser gyroscope over the entire working range of angular velocities. Using these relationships to correct the frequency response of a laser gyroscope makes it possible to reduce the value of nonlinear corrections to 1 – 2 ppm. (laser gyroscopes)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear rotordynamics analysis

The special nonlinearities of the Jeffcott equations in rotordynamics are examined. The immediate application of this analysis is directed toward understanding the excessive vibrations recorded in the LOX pump of the SSME during hot firing ground testing. Deadband, side force and rubbing are three possible sources of inducing nonlinearity in the Jeffcott equations. The present analysis initially reduces these problems to the same mathematical description. A special frequency, named the nonlinear natural frequency is defined and used to develop the solutions of the nonlinear Jeffcott equations as asympotic expansions. This nonlinear natural frequency which is the ratio of the cross-stiffness and the damping, plays a major role in determining response frequencies. Numerical solutions are included for comparison with the analysis. Also, nonlinear frequency-response tables are made for a typical range of values.

Day, W. B.↗

Development of a nondestructive vibration technique for bond assessment of Space Shuttle tiles

This final report describes the achievements of the above titled project. The project is funded by NASA-KSC (Grant No. NAG 10-0117) for the period of 1 Jan. to 31 Dec. 1993. The purpose of this project was to develop a nondestructive, noncontact technique based on 'vibration signature' of tile systems to quantify the bond conditions of the thermal protection system) tiles of Space Shuttle orbiters. The technique uses a laser rapid scan system, modal measurements, and finite element modeling. Finite element models were developed for tiles bonded to both clamped and deformable integrated skin-stringer orbiter mid-fuselage. Results showed that the size and location of a disbonded tile can be determined from frequency and mode shape information. Moreover, a frequency response survey was used to quickly identify the disbonded tiles. The finite element results were compared with experimentally determined frequency responses of a 17-tile test panel, where a rapidscan laser system was employed. An excellent degree of correlation between the mathematical simulation and experimental results was realized. An inverse solution for single-tile assemblies was also derived and is being implemented into a computer program that can interact with the modal testing software. The output of the program displays the size and location of disbond. This program has been tested with simulated input (i.e., finite element data), and excellent agreement between predicted and simulated disbonds was shown. Finally, laser vibration imaging and acoustic emission techniques were shown to be well suited for detecting and monitoring the progressive damage in Graphite/Epoxy composite materials.

Moslehy, Faissal A.↗