Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

High-Resolution Inspection of the Space Shuttle External Tank Spray-on-Foam Insulation (SOFI) using Focused Millimeter Waves at D-Band (150 GHz)

Space Shuttle Columbia's catastrophic failure has been attributed to a piece of spray-on-foam insulation (SOFI) that was dislodged from the external tank and struck the leading edge of the left wing. A piece of SOFI was also dislodged in the recent Space Shuttle Discovery's flight. Clearly, there is a great and urgent need to inspect the external tank SOFI and other similar insulating structures (including the acreage heat tile) in a reliable and robust fashion. In the past two years, millimeter wave nondestructive testing methods, using both real and synthetic focusing techniques, have shown great potential for this purpose. Recently obtained real-focused images from several different and complex SOFI panels have demonstrated the utility of these methods as being viable, robust, repeatable, simple, portable and effective. D-band frequency range which covers a frequency spectrum of 110- 170 GHz is well-suited for this purpose given the nature of the foam which causes significant scattering at much higher frequencies. This paper presents the results of using continuous-wave (CW) reflectometry conducted on several typical and complex SOFI panes at 150 GHz.

Kharkovsky, S.↗

Device and method for generating a beam of acoustic energy from a borehole, and applications thereof

In some aspects of the invention, a method of generating a beam of acoustic energy in a borehole is disclosed. The method includes generating a first acoustic wave at a first frequency; generating a second acoustic wave at a second frequency different than the first frequency, wherein the first acoustic wave and second acoustic wave are generated by at least one transducer carried by a tool located within the borehole; transmitting the first and the second acoustic waves into an acoustically non-linear medium, wherein the composition of the non-linear medium produces a collimated beam by a non-linear mixing of the first and second acoustic waves, wherein the collimated beam has a frequency based upon a difference between the first frequency range and the second frequency, and wherein the non-linear medium has a velocity of sound between 100 m/s and 800 m/s.

47 OTHER INSTRUMENTATION↗

Intrinsic dielectric frequency dependent spectrum of a single domain tetragonal BaTiO3

The intrinsic dielectric frequency dependent spectrum of single domain barium titanate (BaTiO3) at room temperature is investigated by considering the vibration of phonons and the conductivity of the tetragonal system in a wide frequency range up to THz. The proposed model combines Debye type of dissipation, soft mode theory, and the influence of conductivity on the dielectric loss to obtain a more precise dielectric frequency spectrum. The calculated results were compared with experimental data on single domain nanocrystals of BaTiO3, both free standing and suspended in a low dielectric medium. The comparisons provide insight into the mechanism for the dielectric behavior, which can be extended to apply to a range of composites that comprise single domain dielectrics embedded in continuous media. At the lower frequency range, conductivity plays a dominant role in the contribution to the dielectric loss along both a-and c-axes, while the phonon vibration controls the dielectric behavior of the system at higher frequency range. When the conductivity of the system increases, the dielectric loss increases below the MHz range, with such an effect diminishing when the frequency reaches the GHz regime. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4734004]

Liu, SY↗

All-dielectric periodic terajet waveguide using an array of coupled cuboids

In this paper, the recently proposed technique to produce photonic jets (terajets at terahertz (THz) frequencies) using 3D dielectric cuboids is applied in the design of a mesoscale cuboid-chain waveguide. The chains are basically designed with several dielectric cubes with side λ{sub 0} placed periodically along the axial z-axis and separated by an air-gap. Based on this, a systematic study of the focusing properties and wave guiding of this chain is performed when the air-gap between the dielectric cubes is changed from 0.25λ{sub 0} to 3λ{sub 0} with the best performance achieved at 2.5λ{sub 0}. An analysis when losses are included in the cubes is also done, demonstrating a robust performance. Finally, the wave guiding is experimentally demonstrated at sub-THz frequencies with a good agreement with numerical results. The simulation results of focusing and transport properties are carried out using Finite Integration Technique. The results here presented may be scaled to any frequency ranges such as millimeter, sub-millimeter, and optical frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband (0–5 Hz) Fully Deterministic 3D Ground‐Motion Simulations of a Magnitude 7.0 Hayward Fault Earthquake: Comparison with Empirical Ground‐Motion Models and 3D Path and Site Effects from Source Normalized Intensities

We report on high‐performance computing (HPC) fully deterministic simulation of ground motions for a moment magnitude (⁠Mw⁠) 7.0 scenario earthquake on the Hayward fault resolved to 5 Hz using the SW4 finite‐difference code. We computed motions obeying physics‐based 3D wave propagation at a regional scale with an Mw 7.0 kinematic rupture model generated following Graves and Pitarka (2016). Both plane‐layered (1D) and 3D Earth models were considered, with 3D subsurface material properties and topography interpolated from a model of the U.S. Geological Survey (USGS). The resulting ground‐motion intensities cover a broader frequency range than typically considered in regional‐scale simulations, including higher frequencies relevant for engineering analysis of structures. Median intensities for sites across the domain are within the reported between‐event uncertainties (⁠τ⁠) of ground‐motion models (GMMs) across spectral periods 0.2–10 s (frequencies 0.1–5 Hz). The within‐event standard deviation ϕ of ground‐motion intensity measurement residuals range 0.2–0.5 natural log units with values consistently larger for the 3D model. Source‐normalized ratios of intensities (3D/1D) reveal patterns of path and site effects that are correlated with known geologic structure. These results demonstrate that earthquake simulations with fully deterministic wave propagation in 3D Earth models on HPC platforms produce broadband ground motions with median and within‐event aleatory variability consistent with empirical models. Systematic intensity variations for the 3D model caused by path and site effects suggest that these epistemic effects can be estimated and removed to reduce variation in site‐specific hazard estimates. This study motivates future work to evaluate the validity of the USGS 3D model and investigate the development of path and site corrections by running more scenarios.

Rodgers, Arthur J.↗

Tunable all-angle negative refraction and photonic band gaps in two-dimensional plasma photonic crystals with square-like Archimedean lattices

In this paper, the tunable all-angle negative refraction and photonic band gaps (PBGs) in two types of two-dimensional (2D) plasma photonic crystals (PPCs) composed of homogeneous plasma and dielectric (GaAs) with square-like Archimedean lattices (ladybug and bathroom lattices) for TM wave are theoretically investigated based on a modified plane wave expansion method. The type-1 structure is dielectric rods immersed in the plasma background, and the complementary structure is named as type-2 PPCs. Theoretical simulations demonstrate that the both types of PPCs with square-like Archimedean lattices have some advantages in obtaining the higher cut-off frequency, the larger PBGs, more number of PBGs, and the relative bandwidths compared to the conventional square lattices as the filling factor or radius of inserted rods is same. The influences of plasma frequency and radius of inserted rod on the properties of PBGs for both types of PPCs also are discussed in detail. The calculated results show that PBGs can be manipulated by the parameters as mentioned above. The possibilities of all-angle negative refraction in such two types of PPCs at low bands also are discussed. Our calculations reveal that the all-angle negative phenomena can be observed in the first two TM bands, and the frequency range of all-angle negative refraction can be tuned by changing plasma frequency. Those properties can be used to design the optical switching and sensor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The emissions of broadband electrostatic noise in the near vicinity of the Shuttle Orbiter

Measurements of the Space Shuttle environment from the STS-3 and Spacelab 2 missions indicate the presence of oblique ion streams and broadband electrostatic noise. A two-dimensional theoretical model is applied to study a possible causal relationship between the ion streams and the broadband noise, especially in terms of the ion acoustic wave and ion-ion wave modes. This model predicts the generation of waves with frequencies ranging from the ion cyclotron frequency up to values greater than the ion plasma frequency, with the maximum growth rate occurring in the 10-kHz range. These results are consistent with the observational data from the STS-3 mission. The model also shows that these two wave modes can coexist only when the wave vectors of the two wave modes are nearly perpendicular. The parametric dependence of the wave instabilities on the plasma parameters and the inclination of the wave propagation vector is also studied.

Hwang, K. S.↗

Electron density dependence of impedance probe plasma potential measurements

In earlier works, we used spheres of various sizes as impedance probes in demonstrating a method of determining plasma potential, φ{sub p}, when the probe radius is much larger than the Debye length, λ{sub D}. The basis of the method in those works [Walker et al., Phys. Plasmas 13, 032108 (2006); ibid. 15, 123506 (2008); ibid. 17, 113503 (2010)] relies on applying a small amplitude signal of fixed frequency to a probe in a plasma and, through network analyzer-based measurements, determining the complex reflection coefficient, Γ, for varying probe bias, V{sub b}. The frequency range of the applied signal is restricted to avoid sheath resonant effects and ion contributions such that ω{sub pi} ≪ ω ≪ ω{sub pe}, where ω{sub pi} is the ion plasma frequency and ω{sub pe} is the electron plasma frequency. For a given frequency and applied bias, both Re(Z{sub ac}) and Im(Z{sub ac}) are available from Γ. When Re(Z{sub ac}) is plotted versus V{sub b}, a minimum predicted by theory occurs at φ{sub p} [Walker et al., Phys. Plasmas 17, 113503 (2010)]. In addition, Im(Z{sub ac}) appears at, or very near, a maximum at φ{sub p}. As n{sub e} decreases and the sheath expands, the minimum becomes harder to discern. The purpose of this work is to demonstrate that when using network analyzer-based measurements, Γ itself and Im(Z{sub ac}) and their derivatives are useful as accompanying indicators to Re(Z{sub ac}) in these difficult cases. We note the difficulties encountered by the most commonly used plasma diagnostic, the Langmuir probe. Spherical probe data is mainly used in this work, although we present limited data for a cylinder and a disk. To demonstrate the effect of lowered density as a function of probe geometry, we compare the cylinder and disk using only the indicator Re(Z{sub ac})

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Glass transition and composite formation in InF{sub 3}-containing oxyfluoroniobate system

The glasses in the system MnNbOF{sub 5}-BaF{sub 2}-InF{sub 3} have been firstly synthesized and studied. The thermal parameters of these glasses are analyzed. It was stated that glass of the composition 40MnNbOF{sub 5}-40BaF{sub 2}-20InF{sub 3} is the most thermal stable in the system under study. By X-ray analysis the compositions of the crystalline phases obtained at the glass thermal treatment were determined: the main phases are Ba{sub 3}In{sub 2}F{sub 12} and BaNbOF{sub 5}. By Raman and IR spectra analysis it was stated that the networks of glasses in the system are built by the structural type of the glasses in NbO{sub 2}F-BaF{sub 2} system: (NbO{sub n}F{sub m}) polyhedra joined oxygen bridges. Indium trifluoride forms InF{sub 6} polyhedra, which are embeded between oxyfluoroniobate ions, forming a common networks or forms its own layers from InF{sub 6} polyhedra. IR-spectroscopy method showed that at devitrification of the sample 30MnNbOF{sub 5}-50BaF{sub 2}-20InF{sub 3} the band position and shape change in going from glass state to crystalline. The bands in the range 900–700 cm{sup −1} shift into the low-frequency range and transformed into narrow peaks characteristic for the crystalline state. It was determined that for this sample the IR-spectroscopy method fixes the presence of the crystalline phases at 340°C without time of exposure, despite the fact that X-ray analysis shows an amorphous state for this sample at the same temperature. It was suggested, that controlling the composition and conditions of annealing of the glasses it can be obtain the transparent glass-ceramics of definite composition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determining moisture content of Traditional Chinese Medicines using a near-infrared LED-based moisture content sensor with spectrum analysis

In Traditional Chinese Medicine (TCM), moisture content (MC) inspection using voltage level or a lock-in amplifier, with a features-based near-infrared light-emitting diode sensor is possible. Abundant absorption response in a wide frequency range and information in both the time-domain and frequency-domain can be obtained, with the square excitation method. However, planeness, heterogeneous particle sizes, and measurement noise negatively affect the time-domain feature during MC inspection. In this work, spectrum analysis (SA) for feature extraction is investigated, to precisely measure the MC of Dutong pills. The principal components for low and high frequencies, are aimed at counteracting the dimensional methods, which are used for supplying the lower dimensional features. The SA experimental results demonstrate that the low frequency components, ranging from the base to the 3rd harmonic components, have a high linear correlation with the MC. The calibration and validation experimental results reveal that the MC can be a monotonic function about the SA amplitudes or first principal component (PC1), with the proposed sensor. This method has the potential to be used for gauging automatic, in situ MCs, particularly for quality control and Process Analytical Technology in TCM. Future research opportunities include improving accuracy and application of the method under field conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact high-performance low-field NMR apparatus for measurements on fluids at very high pressures and temperatures

We discuss an innovative new high-performance apparatus for performing low-field Nuclear Magnetic Resonance (NMR) relaxation times and diffusion measurements on fluids at very high pressures and high temperatures. The apparatus sensor design and electronics specifications allow for dual deployment either in a fluid sampling well logging tool or in a laboratory. The sensor and electronics were designed to function in both environments. This paper discusses the use of the apparatus in a laboratory environment. The operating temperature and pressure limits, and the signal-to-noise ratio (SNR) of the new system exceed by a very wide margin what is currently possible. This major breakthrough was made possible by a revolutionary new sensor design that breaks many of the rules of conventional high pressure NMR sensor design. A metallic sample holder capable of operating at high pressures and temperatures is provided to contain the fluid under study. The sample holder has been successfully tested for operation up to 36 Kpsi. A solenoid coil wound on a slotted titanium frame sits inside the metallic sample holder and serves as an antenna to transmit RF pulses and receive NMR signals. The metal sample holder is sandwiched between a pair of gradient coils which provide a linear field gradient for pulsed field gradient diffusion measurements. The assembly sits in the bore of a low-gradient permanent magnet. The system can operate over a wide frequency range without the need for tuning the antenna to the Larmor frequency. The SNR measured on a water sample at room temperature is more than 15 times greater than that of the commercial low-field system in our laboratory. Thus, the new system provides for data acquisition more than 200 times faster than was previously possible. Laboratory NMR measurements of relaxations times and diffusion coefficients performed at pressures up to 25 Kpsi and at temperatures up to 175 °C with crude oils enlivened with dissolved hydrocarbon gases (referred to as “live oils”) are shown. This is the first time low-field NMR measurements have been performed at such high temperatures and pressures on live crude oil samples. We discuss the details of the apparatus design, tuning, calibration, and operation. NMR data acquired at multiple temperatures and pressures on a live oil sample are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ARTEMIS Observations of Plasma Waves in Laminar and Perturbed Interplanetary Shocks

The ‘Acceleration, Reconnection, Turbulence and Electrodynamics of the Moon's Interaction with the Sun’ (ARTEMIS) mission provides a unique opportunity to study the structure of interplanetary shocks and the associated generation of plasma waves with frequencies between ~50-8000 Hz due to its long duration electric and magnetic field burst waveform captures. We compare wave properties and occurrence rates at 11 quasi-perpendicular interplanetary shocks with burst data within 10 minutes (~3200 proton gyroradii upstream, ~1900 downstream) of the shock ramp. A perturbed shock is defined as possessing a large amplitude whistler precursor in the quasi-static magnetic field with an amplitude greater than ⅓ the difference between the upstream and downstream average magnetic field magnitudes; laminar shocks lack these large precursors and have a smooth, step function-like transition. In addition to wave modes previously observed, including ion acoustic, whistler, and electrostatic solitary waves, waves in the ion acoustic frequency range that show rapid temporal frequency change are common. Three shocks had burst captures in the ramp; of these, the two laminar shocks with burst data in the ramp contained a wide range of large amplitude wave modes in the ramp whereas the one perturbed shock contained no such waves. Thus, energy dissipation through wave-particle interactions is more prominent in these two laminar shocks than in the perturbed shock. Based on observations from all 11 shocks, the The wave occurrence rates for laminar shocks are higher in the transition region, especially the ramp, than downstream. In contrast, perturbed shocks have approximately 2-3 times the wave occurrence rate downstream than laminar shocks.

L. A. Davis↗

Efficient and versatile graphene-based multilayers for EM field absorption

We thoroughly investigate the possibility to absorb most (i.e., up to more than 90%) of the incident electro-magnetic radiations in thin multilayered PMMA/graphene structures, thus proposing the technical realization of a device with an operational frequency range in the millimeter-wave domain, i.e., 30 GHz–300 GHz. Our simulations demonstrate the concrete possibility to enhance the field absorption by means of a selective removal and proper micro-pattering within the graphene material, enabling a complete and efficient control of the graphene sheet conductance. This method is applied to design and engineer a class of devices, endowed with a wideband operation capability, showing almost no fluctuations throughout the whole range of mm-wave frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MHz gravitational wave constraints with decameter Michelson interferometers

A new detector, the Fermilab Holometer, consists of separate yet identical 39-meter Michelson interferometers. Strain sensitivity achieved is better than 10 –21 /√Hz between 1 to 13 MHz from a 130-h data set. This measurement exceeds the sensitivity and frequency range made from previous high frequency gravitational wave experiments by many orders of magnitude. Constraints are placed on a stochastic background at 382 Hz resolution. The 3σ upper limit on Ω GW , the gravitational wave energy density normalized to the closure density, ranges from 5.6 × 10 12 at 1 MHz to 8.4 × 10 15 at 13 MHz. Another result from the same data set is a search for nearby primordial black hole binaries (PBHB). There are no detectable monochromatic PBHBs in the mass range 0.83–3.5 × 10 21 g between the Earth and the Moon. Projections for a chirp search with the same data set increase the mass range to 0.59–2.5 × 10 25 g and distances out to Jupiter. Furthermore, this result presents a new method for placing limits on a poorly constrained mass range of primordial black holes. Additionally, solar system searches for PBHBs place limits on their contribution to the total dark matter fraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Narrow-band near-field nanoscopy in the spectral range from 1.3 to 8.5 THz

Nano-spectroscopy in the terahertz frequency range remains challenging despite recent technological progress in developing both THz emitter sources and near-field optical microscopy (SNOM). Here, we combine scattering-type SNOM with a free-electron laser light source, to tune into the 1.3–8.5 THz range. A significant portion of this range, namely, the frequencies above ∼3 THz, is not covered by previously reported near-field microscopy systems. However, it constitutes an indispensable regime where many elementary processes in solids including collective lattice excitations, charge, and spin transport occur. Our approach of nano-spectroscopy and nano-imaging provides a versatile analysis of nanostructures as small as 50 nm, hence beating the optical diffraction limit by λ/4600.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Latitudinal beaming of Jupiter's low frequency radio emissions

By comparing RAE-1 and IMP-6 satellite measurements of Jupiter's radio emission near 1MHz with recent Voyager-1 and 2 observations in the same frequency range, the properties of the low frequency radiation pattern over a 10 deg range of latitudes with respect to the Jovian rotation equator can be studied. These observations, which cover a wider latitudinal range than is possible from the earth, are consistent with many aspects of earlier ground-based measurements used to infer a sharp beaming pattern for the decameter wavelength emissions. Marked, systematic changes are found in the statistical occurrence probability distributions with system 3 central meridian longitude as the jovigraphic latitude of the observer changes over this range. Simultaneous observations by the two Voyager spacecraft suggest that the instantaneous beam width may be no more than a few degrees at times. The new hectometer-wave results can be interpreted in terms of a narrow, curved sheet at a fixed magnetic latitude into which the emission is beamed to escape the planet.

Alexander, J. K.↗

Dielectric Properties of Nanocrystalline Tungsten Oxide in the Temperature Range of 223–293 K

The dielectric properties of nanocrystalline tungsten oxide are studied in the temperature range of 223–293 K and in the frequency range ν = 10{sup –2}–10{sup 6} Hz. Powders of WO{sub 3} with particle sizes of 110, 150, and 200 nm are prepared by the heat treatment of ammonium paratungstate at various temperatures. It is established that the frequency dependences of the conductivity for all samples increase with an increase in frequency, while the polarization characteristics ε'(ν) and ε'(ν) decrease. It is found that the frequency dependences of the conductivity are described by a function of the form ν{sup s} with an index in the range of (0.83–0.90) ± 0.01, which is characteristic of the “hopping” mechanism of charged-particle motion (complexes) over localized states confined by potential barriers and structural defects.

36 MATERIALS SCIENCE↗