Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A graphical approach to the efficiency of flat-plate collectors

A nomogram is described which can be used to determine the thermal performance of flat plate solar collectors, resulting in two performance factors: the net absorptance and the net heat loss coefficient. The nomogram takes into account angle of incidence, collector slope, absorber plate design, insulating materials, thicknesses, optical properties of absorbing surfaces and glazing materials, and flow factors. A case example is given to illustrate the use of the nomogram.

Selcuk, M. K.↗

Environmental testing of flat plate solar cell modules

Commercially available flat-plate solar cell modules have been subjected to a variety of environmental tests designed to simulate service conditions. Among the tests are those simulating heat and rain, wind-driven rains, humidity and freezing, humidity and heat, humidity with a voltage bias, salt fog, hail impact, and fungus infestation. Tests for optical surface soiling and the combined effects of temperature, humidity and UV irradiation are under development. A correlation has been demonstrated between degradation caused by the qualification tests and such observed field effects as power loss.

Griffith, J.↗

Numerical solution for supersonic flow near the trailing edge of a flat plate

In the present study, problems of laminar and turbulent two-dimensional flow of a viscous compressible fluid near the trailing edge of a thin flat plate are considered. The complete set of Navier-Stokes equations is solved by the finite-difference method of MacCormack (MacCormack and Baldwin, 1975). It is an explicit, predictor-corrector, time-splitting method of second order acuracy. The computational mesh employed has sufficient resolution for all the characteristic lengths suggested by theory. In the laminar case, the present results are compared with the triple deck solution of Daniels (1974). This comparison indicates that the asymptotic triple deck theory for supersonic trailing edge flow is accurate within five percent for Reynolds numbers greater than 1000. In the turbulent case, the Prandtl-Van Driest-Clauser algebraic eddy viscosity model is used. The numerical results show that the region of upstream influence is approximately of the order of the boundary layer thickness. The solutions for skin-friction, pressure and wake center-line velocity are presented.

Degani, D.↗

Environmental requirements for flat plate photovoltaic modules for terrestrial applications

The environmental test requirements that have been developed for flat plate modules purchased through Department of Energy funding are described. Concurrent with the selection of the initial qualification tests from space program experience - temperature cycling and humidity - surveys of existing photovoltaic systems in the field revealed that arrays were experiencing the following failure modes: interconnect breakage, delamination, and electrical termination corrosion. These coupled with application-dependent considerations led to the development of additional qualification tests, such as cyclic pressure loading, warped mounting surface, and hail. Rationale for the selection of tests, their levels and durations is described. Comparisons between field-observed degradation and test-induced degradation show a positive correlation with some of the observed field effects. Also, the tests are proving useful for detecting design, process, and workmanship deficiencies. The status of study efforts for the development of environmental requirements for field-related problems is reviewed.

Hoffman, A. R.↗

Environmental testing of terrestrial flat plate photovoltaic modules

The Low-Cost Solar Array (LSA) Project at the Jet Propulsion Laboratory has as one objective: the development and implementation of environmental tests for flat plate photovoltaic modules as part of the Department of Energy's terrestrial photovoltaic program. Modules procured under this program have been subjected to a variety of laboratory tests intended to simulate service environments, and the results of these tests have been compared to available data from actual field service. This comparison indicates that certain tests (notably temperature cycling, humidity cycling, and cyclic pressure loading) are effective indicators of some forms of field failures. Other tests have yielded results useful in formulating module design guidelines. Not all effects noted in field service have been successfully reproduced in the laboratory, however, and work is continuing in order to improve the value of the test program as a tool for evaluating module design and workmanship. This paper contains a review of these ongoing efforts and an assessment of significant test results to date.

Hoffman, A.↗

Wind Loads on Flat Plate Photovoltaic Array Fields

The aerodynamic forces resulting from winds acting on flat plate photovoltaic arrays were investigated. Local pressure distributions and total aerodynamic forces on the arrays are shown. Design loads are presented to cover the conditions of array angles relative to the ground from 20 deg to 60 deg, variable array spacings, a ground clearance gap up to 1.2 m (4 ft) and array slant heights of 2.4 m (8 ft) and 4.8 m (16 ft). Several means of alleviating the wind loads on the arrays are detailed. The expected reduction of the steady state wind velocity with the use of fences as a load alleviation device are indicated to be in excess of a factor of three for some conditions. This yields steady state wind load reductions as much as a factor of ten compared to the load incurred if no fence is used to protect the arrays. This steady state wind load reduction is offset by the increase in turbulence due to the fence but still an overall load reduction of 2.5 can be realized. Other load alleviation devices suggested are the installation of air gaps in the arrays, blocking the flow under the arrays and rounding the edges of the array. A wind tunnel test plan to supplement the theoretical study and to evaluate the load alleviation devices is outlined.

Miller, R.↗

Full-coverage film cooling on flat, isothermal surfaces: Data and predictions

The heat transfer and fluid mechanics characteristics of full-coverage film cooling were investigated. The results for flat, isothermal plates for three injection geometries (normal, slant, and compound angle) are summarized and data concerning the spanwise distribution of the heat transfer coefficient within the blowing region are presented. Data are also presented for two different numbers of rows of holes (6 and 11). The experimental results summarized can be predicted with a two dimensional boundary layer code, STANCOOL, by providing descriptors of the injection parameters as inputs.

Crawford, M. E.↗

Preliminary design of large reflectors with flat facets

A concept for approximating curved antenna surfaces using flat facets is discussed. A preliminary design technique for determining the size of the reflector surface facets necessary to meet antenna surface accuracy requirements is presented. A proposed large Microwave Radiometer Satellite is selected as an application, and the far field electromagnetic response of a faceted reflector surface is compared with that from a spherical reflector surface.

Agrawal, P. K.↗

Calculation of oblique-shock-wave laminar-boundary-layer interaction on a flat plate

A finite difference solution to the problem of the interaction between an impinging oblique shock wave and the laminar boundary layer on a flat plate is presented. The boundary layer equations coupled with the Prandtl-Meyer relation for the external flow are used to calculate the flow field. A method for the calculation of the separated flow region is presented and discussed. Comparisons between this theory and the experimental results of other investigators show fairly good agreement. Results are presented for the case of a cooled wall with an oncoming flow at Mach number 2.0 without and with suction. The results show that a small amount of suction greatly reduces the extent of the separated region in the vicinity of the shock impingement location.

Goldberg, U.↗

Pollutant emissions from flat-flame burners at high pressures

Maximum flame temperatures and pollutant emission measurements for NOx, CO, and UHC (unburned hydrocarbons) are reported for premixed methane air flat flames at constant total mass flow rate over the pressure range from 1.9 to 30 atm and for equivalence ratios from 0.84 to 1.12. For any given pressure, maxima typically occur in both the temperature and NOx emissions curves slightly to the lean side of stoichiometric conditions. The UHC emissions show minima at roughly the same equivalence ratios. The CO emissions, however, increase continually with increasing equivalence ratio. Flame temperature and NOx emissions decrease with increasing pressure, while the opposite is true for the CO and UHC emissions. The NOx data correlate reasonably well as a function of flame temperature only. Four flameholders, differing only slightly, were used. In general, the temperature and emissions data from these four flameholders are similar, but some differences also exist. These differences appear to be related to minor variations in the condition of the flameholder surfaces.

Maahs, H. G.↗

Buckling and postbuckling research on flat and curved composite panels

Progress in the development of verified design technology for generic advanced-composite structural components loaded in compression is reported. Generic structural configurations material systems and load ranges of interest for a given application were investigated using structural procedures, structural analysis procedures, and laboratory testing of structural specimens. Both flat and curved composite compression panels that are designed either to be buckling resistant or to have postbuckling strength depending on the expected application of the panels were considered.

Starnes, J. H., Jr.↗

The very flat radio spectrum of 0735 plus 178 - A cosmic conspiracy

Multifrequency interferometric and total flux density measurements of the radiation from 0735 plus 178 are discussed. It is shown that it is far more likely that the very flat radio spectrum of this source results from a superposition of incoherent synchrotron radiation from four distinct, homogeneous components, each with a peaked spectrum, than from radiation from a single inhomogeneous component.

Cotton, W. D.↗

Testing flat plate photovoltaic modules for terrestrial environment

New qualification tests have been developed for flat plate photovoltaic modules. Temperature cycling, cyclic pressure load, and humidity exposure are especially useful for detecting design and fabrication deficiencies. There is positive correlation between many of the observed field effects, such as power loss, and qualification test induced degradation. The status of research efforts for the development of test methodology for field-related problems is reviewed.

Hoffman, A. R.↗

Wind loads on flat plate photovoltaic array fields

The results of an experimental analysis (boundary layer wind tunnel test) of the aerodynamic forces resulting from winds acting on flat plate photovoltaic arrays are presented. Local pressure coefficient distributions and normal force coefficients on the arrays are shown and compared to theoretical results. Parameters that were varied when determining the aerodynamic forces included tilt angle, array separation, ground clearance, protective wind barriers, and the effect of the wind velocity profile. Recommended design wind forces and pressures are presented, which envelop the test results for winds perpendicular to the array's longitudinal axis. This wind direction produces the maximum wind loads on the arrays except at the array edge where oblique winds produce larger edge pressure loads. The arrays located at the outer boundary of an array field have a protective influence on the interior arrays of the field. A significant decrease of the array wind loads were recorded in the wind tunnel test on array panels located behind a fence and/or interior to the array field compared to the arrays on the boundary and unprotected from the wind. The magnitude of this decrease was the same whether caused by a fence or upwind arrays.

Miller, R. D.↗

Wind loads on flat plate photovoltaic array fields (nonsteady winds)

Techniques to predict the dynamic response and the structural dynamic loads of flat plate photovoltaic arrays due to wind turbulence were analyzed. Guidelines for use in predicting the turbulent portion of the wind loading on future similar arrays are presented. The dynamic response and the loads dynamic magnification factor of the two array configurations are similar. The magnification factors at a mid chord and outer chord location on the array illustrated and at four points on the chord are shown. The wind tunnel test experimental rms pressure coefficient on which magnification factors are based is shown. It is found that the largest response and dynamic magnification factor occur at a mid chord location on an array and near the trailing edge. A technique employing these magnification factors and the wind tunnel test rms fluctuating pressure coefficients to calculate design pressure loads due to wind turbulence is presented.

Miller, R. D.↗

Design optimization of sinusoidal glass honeycomb for flat plate solar collectors

The design of honeycomb made of sinusoidally corrugated glass strips was optimized for use in water-cooled, single-glazed flat plate solar collectors with non-selective black absorbers. Cell diameter (d), cell height (L), and pitch/diameter ratio (P/d) maximizing solar collector performance and cost effectiveness for given cell wall thickness (t sub w) and optical properties of glass were determined from radiative and convective honeycomb characteristics and collector performance all calculated with experimentally validated algorithms. Relative lifetime values were estimated from present materials costs and postulated production methods for corrugated glass honeycomb cover assemblies. A honeycomb with P/d = 1.05, d = 17.4 mm, L = 146 mm and t sub w = 0.15 mm would provide near-optimal performance over the range delta T sub C greater than or equal to 0 C and less than or equal to 80 C and be superior in performance and cost effectiveness to a non-honeycomb collector with a 0.92/0.12 selective black absorber.

Mcmurrin, J. C.↗

SAM II aerosol profile measurements, Poker Flat, Alaska; July 16-19, 1979

SAM II satellite measurements during the July 1979 Poker Flat mission, yielded an aerosol extinction coefficient of 0.0004/km at 1.0 micron wavelength, in the region of the stratospheric aerosol mixing ratio peak (12-16 km). The stratospheric aerosol optical depth for these data, calculated from the tropopause through 30 km, is approximately 0.001. These results are consistent with the average 1979 summertime values found throughout the Arctic.

Mccormick, M. P.↗

Comparison of stratospheric aerosol measurements over Poker Flat, Alaska, July, 1979

Stratospheric aerosols were collected at Poker Flat, Alaska, in July, 1979, to determine particle properties, confirm coincident satellite SAGE measurements, and compare similar results obtained with different airborne samplers. Because of the steep slopes in size-distribution curves for larger particles, it is found that properties such as concentrations, aerosol mass, and optical extinction are very sensitive to small errors in radii. It is calculated that the concentration measurements agree with photoelectric particle counter results when a 16% radius change is introduced. An 8% radius change matches our calculated sulfate mass with filter mass measurements. And a 13% radius change results in agreement between the calculated optical extinction and coincident SAGE satellite results. Recognizing that different instruments can produce 10-20% differences in measured sizes, it is believed the results of these comparative measurements of SAGE and in situ instruments are essentially in agreement.

Farlow, N. H.↗