Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “first wall”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Impact of particle size and particle-flow-wall coupling on pressurized oxy-combustion in the down-fired burner

Concerns over climate change have led to numerous efforts in developing low-carbon energy technologies. Pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in power generation. Designing an effective burner plays a vital role in developing new coal combustion technologies. Because of the high pressure, the volume fraction of coal particles at the fuel inlet of the burner of a pressurized oxy-combustor is close or even higher than the maximum limit that commercial CFD codes (e.g., ANSYS FLUENT) can handle. At this high particle volume fraction, the interactions among particles, fluid flow, and wall need to be re-evaluated. The present computational work is the first step of a systematic analysis of the particle influence, like releasing method, releasing locating, and particle size, in a pilot-scale POC combustor, developed at Washington University in St. Louis (WUSTL). In a POC process, pulverized coal is burned under elevated pressure and O2-CO2 environment. Specifically, a 15-bar, 100 kWth, POC combustor is modeled employing ANSYS FLUENT, using Reynolds-averaged Navier-Stokes (RANS) modeling. It is revealed that for this pilot-scale, pressurized burner, velocity profiles of the near-wall region in this POC facility exhibit some discrepancy against the near-wall turbulent flow velocity profile. In order to investigate the particle influence in the near-wall region, particle releasing location will be investigated. Numerical simulation results exhibit the coupling effect of turbulence flow and particles in this case. The particle size also demonstrates a great effect on particle trajectory, then further has an impact on flame stability and temperature.

Li, Lei↗

The effects of compliant walls on transition and turbulence

Two theoretical approaches to the phenomenon of drag reduction by a compliant wall are proposed. One is to study the limit cycle oscillations of the Navier-Stokes equations for a boundary layer flow over a compliant wall or a Poiseuille flow in a channel with a compliant wall. The other is a complementary study of a simpler, sequential model, which partially decouples the fluid and wall motions. In this approach, a 'Total Model' is constructed from suitable component models. While the first study is more rigorously based, it will be initially limited, by computational constraints, to relatively low Reynolds numbers. The second, more approximate approach, will allow consideration of a fully developed turbulent flow. The Total Model will predict the compliant wall motion accurately, but will not per se be sufficient to predict the skin friction drag. However, once the wall motion is known, the skin friction drag and the pressure drag can be computed separately, using one of the existing models.

Dowell, E. H.↗

A numerical investigation of coal particle modeling for the inlet section of a pressurized oxy-combustion burner

Concerns over climate change have led to numerous efforts to develop low-carbon technologies, and pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in the power industry. Designing an effective burner for such technologies is vital for the development of these and other coal combustion technologies. Because of the high pressure, the volume fraction of coal particles at the fuel inlet of the pressurized oxy-combustor burner is close to or even higher than the maximum limit for commercial CFD codes (e.g., ANSYS FLUENT). At these high particle volume fractions, the interactions among particles, fluid flow and wall need to be re-evaluated. The present computational work is a first step in a systematic analysis of the influence of various parameters, like method of particle release, release location, and particle size, in a pilot-scale POC combustor, developed at Washington University in St. Louis (WUSTL). In the POC process, pulverized coal is burned under elevated pressure in an O2-CO2 environment. Specifically, a 15-bar, 100 kWth, POC combustor is modeled employing Ansys FLUENT commercial sodtware using the Reynolds-Averaged Navier-Stokes (RANS) approach. It is revealed that for this pilot-scale, pressurized burner, velocity profiles in the near-wall region exhibit some anomalies. In order to investigate the influence of particle loading in the near-wall region, particle release location was investigated. The numerical simulations incorporate the coupling between the turbulent flow and the particles. A sensitivity investigation of particle release location found that by tuning the release location, the velocity profile can be consistent with the pure gas flow velocity profile. More importantly, the particle releasing location also affects flame stability. Particle size was also found to have a significant impact on particle trajectory, flame stability and temperature. Finally, Large Eddy Simulations (LES) were performed and compared with the results from two-dimensional RANS.

Li, Lei↗

History of Ultrasonic Inspection of High-Level Waste Tanks at SRS - 20220

The Liquid Waste Disposition Projects (LWDP) Structural Authority and Inspection Engineering Support Group has teamed with the Materials Science and Technology Non-destructive Evaluation Group of Savannah River National Laboratory (SRNL) to implement a comprehensive In-Service Inspection (ISI) program for the High-Level Waste (HLW) tanks in the sites tank farms. The purpose of this program is to demonstrate the structural and leak integrity of the tanks to maintain the function of waste containment throughout the desired service life. Four types of waste tanks were constructed at Savannah River Site (SRS) from 1951 thru 1981 to store radioactive nuclear waste from the separations process. The Type I, II and III are carbon steel cylindrical tanks with varying degrees of access to the side walls and very limited access to the tank bottom. The tanks contain 750,000 to 1.3 million gallons of waste and are buried or backfilled with soil. The tanks are 75'-85' in diameter and 24'-33' from tank bottom to the tank roof. Inspection of the HLW tanks is made difficult by radiation, contamination, and small access openings. Through the years these challenges have been overcome by progressive improvements to programs and equipment resulting in the sophisticated wall crawler Ultrasonic Testing (UT) technology of today. A formal inspection program was developed and put in service in 1972. UT thickness measurements were first made in 1967 and 1969 of selected waste tanks using an analog-type instrument to measure the thickness of the carbon steel walls. Routine inspections for thinning were performed from 1972-1985 and then discontinued because no thinning had been observed and this technique could not detect pitting or cracking. UT inspections resumed in 1994 using a sophisticated robotic wall crawler with UT technology capable of detecting thinning, cracking and pitting. The current program focuses on the newer Type III tanks that are used primarily for storage. The program was upgraded in 2003 to include selected regions of the tank wall, secondary wall and annulus floor on a 7 to 10-year frequency. The facility is currently in its third cycle of tank inspections. Thus far, there have been no reportable indications of service induced degradation. This result provides assurance that the chemistry control program has been effective at mitigating corrosion and that the tanks remain structurally sound even after more than 40 years of service. This paper will present the UT technology first used at SRS and the evolution to the current systems and their capabilities. Additionally, plans for equipment upgrades that will improve the extent of inspection will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Visualization of lignification in flax stem cell walls with novel click-compatible monolignol analogs

As an essential part of plant cell walls, lignin provides mechanical support for plant growth, enhances water transport, and helps to defend against pathogens. As the most abundant natural aromatic-based renewable resource on earth, its biosynthesis has always been a research focus, and it is still currently under study. In this study, the p-coumaryl alcohol analog (H ALK ) and the coniferyl alcohol analog (G ALK ) containing an alkyne group at the ortho position were synthesized and applied to lignification in vivo and in vitro. The incorporation of these novel lignin monomers was observed via fluorescence imaging. It was found that the two monolignol analogs could be incorporated in dehydrogenated polymers (DHPs) in vitro and in flax cell walls in vivo. The results showed that as the cultivation time and precursor concentration varied, the deposition of H and G-type lignin exhibited differences in deposition mode. At the subcellular scale, the deposited lignin first appears in the cell corner and the middle lamella, and then gradually appears on the cell walls. Furthermore, lignin was also found in bast fiber. It was demonstrated that these new molecules could provide high-resolution localization of lignin during polymerization.

59 BASIC BIOLOGICAL SCIENCES↗

A Wall Correction Program Based on Classical Methods for the National Transonic Facility (Solid Wall or Slotted Wall) and the 14x22-Ft Subsonic Tunnel at NASA LaRC

A Fortran subroutine CMWALL is described, which is an implementation of the collective information from classical methods-based wall corrections. These methods use established closed-form expressions which were developed based on simple linear potential-based methods. This is a simple and rapid tool to calculate corrections due to wall interference in the National Transonic Facility (Solid Wall or Slotted Wall) or the 14x22-Ft Subsonic Tunnel at NASA LaRC. It is designed to be easily implemented in the existing tunnel data reduction programs, either as real-time or post-point. It is however important to realize that the method is based on the simplifying assumptions of linearity, small model and attached flow. The computed results are thus to be viewed as first-cut estimates, to be refined further using more complex methods based on measured wall pressures (known as wall signature methods).

Hemsch, Michael J.↗

Flow in additively manufactured super-rough channels

Metal additive manufacturing has enabled geometrically complex internal cooling channels for turbine and heat exchanger applications, but the process gives rise to large-scale roughness whose size is comparable to the channel height (which is 500 $\mathrm {\mu }$ m). These super-rough channels pose previously unseen challenges for experimental measurements, data interpretation and roughness modelling. First, it is not clear if measurements at a particular streamwise and spanwise location still provide accurate representation of the mean (time- and plane-averaged) flow. Second, we do not know if the logarithmic layer survives. Third, it is unknown how well previously developed rough-wall models work for these large-scale roughnesses. To answer the above practical questions, we conduct direct numerical simulations of flow in additively manufactured super-rough channels. Three rough surfaces are considered, all of which are obtained from computed tomography scans of additively manufactured surfaces. The roughness’ trough to peak sizes are 0.1 $h$ , 0.3 $h$ and 0.8 $h$ , respectively, where $h$ is the intended half-channel height. Each rough surface is placed opposite a smooth wall and the other two rough surfaces, leading to six rough-wall channel configurations. Two Reynolds numbers are considered, namely $Re_\tau =180$ and $Re_\tau =395$ . We show first that measurements at one streamwise and spanwise location are insufficient due to strong mean flow inhomogeneity across the entire channel, second that the logarithmic law of the wall survives despite the mean flow inhomogeneity and third that the established roughness sheltering model remains accurate.

Altland, Samuel↗

Heat transfer in laminar wall boundary layer within noncentered unsteady expansion wave

The paper summarizes results of theoretical and experimental investigations of wall temperature change and heat transfer in the laminar boundary layer formed within noncentered unsteady expansion waves in shock tubes. The study is restricted to a class of noncentered plane waves which have one key feature in common with centered waves, i.e., the first derivatives of the inviscid flow quantities have values or are discontinuous at the wavehead. The wall temperature is calculated implicitly by matching the local heat transfer rates of gas and wall thermal boundary layers. Experimentally, the wall temperature was measured using a thin-film resistance thermometer and heat transfer was then deduced using a one-dimensional unsteady heat conduction equation.

Srinivasan, G.↗

Cold plate with combined inclined impingement and ribbed channels

Heat transfer devices and methods for making the same that include a first enclosure having at least one inlet port; a second enclosure having a bottom plate and one or more dividing walls to establish channels, at least one internal surface of each channel having rib structures to create turbulence in a fluid flow; and a jet plate connecting the first enclosure and the second enclosure having impinging jets that convey fluid from the first enclosure to the channels, said impinging jets being set at an angular deviation from normal to cause local acceleration of fluid and to increase a local heat transfer rate.

42 ENGINEERING↗

Aerofoil testing in a self-streamlining flexible walled wind tunnel

Two-dimensional self-streamlining flexible walled test sections eliminate, as far as experimentally possible, the top and bottom wall interference effects in transonic aerofoil testing. The test section sidewalls are rigid, while the impervious top and bottom walls are flexible and contoured to streamline shapes by a system of jacks, without reference to the aerofoil model. The concept of wall contouring to eliminate or minimise test section boundary interference in two-dimensional testing was first demonstrated by the National Physical Laboratory (NPL) in England during the early 1940's. The transonic streamlining strategy proposed, developed and used by NPL has been compared with several modern strategies. The NPL strategy has proved to be surprisingly good at providing a wall interference-free test environment, giving model performance indistinguishable from that obtained when using the modern strategies over a wide range of test conditions. In all previous investigations the achievement of wall streamlining in flexible walled test sections has been limited to test conditions up to those which result in the model's shock just extending to a streamlined wall. This work, however, has also successfully demonstrated the feasibility of two-dimensional wall streamlining at test conditions where both model shocks have reached and penetrated through their respective flexible walls. Appropriate streamlining procedures have been established and are uncomplicated, enabling flexible walled test sections to easily cope with these high transonic flows.

Mark Charles Lewis↗

Enhancing the Electrode Gravimetric Capacity of Li 1.2 Mn 0.4 Ti 0.4 O 2 Cathode Using Interfacial Carbon Deposition and Carbon Nanotube-Mediated Electrical Percolation

Mn-based cation disordered rocksalt oxides (Mn-DRX) are emerging as promising cathode materials for next-generation Li-ion batteries due to their high specific capacities and cobalt and nickel free characteristic. However, to reach the theoretical capacity, solid-state method synthesized Mn-DRX materials require activation via post-synthetic ball milling, typically incorporating more than 20 wt.% conductive carbon that adversely reduces the electrode level gravimetric capacity. To solve this issue, we firstly deposit amorphous carbon on the surface of the Li 1.2 Mn 0.4 Ti 0.4 O 2 (LMTO) particles to increase the electrical conductivity by a five order of magnitude. Although the cathode material gravimetric first charge capacity reaches 180 mAh/g, its highly irreversible behavior leads to a 70 mAh/g first discharge capacity. Subsequently, to ensure a good electrical percolation network, the LMTO material is ball milled with multi-wall carbon nanotube (CNT) to obtain a 78.7 wt.% LMTO active material loading in the cathode electrode (LMTO-CNT). As a result, a 210 mAh/g cathode electrode gravimetric first charge and 165 mAh/g first discharge capacity are obtained, compared to the respective capacity values of 222 mAh/g and 155 mAh/g for the LMTO ball milled with 20 wt.% SuperP C65 electrode (LMTO-SP). After 50 cycles, the LMTO-CNT delivers a 121 mAh/g electrode gravimetric discharge capacity, largely outperforming the 44 mAh/g value of the LMTO-SP. In conclusion, our study demonstrates that while ball milling is necessary to achieve the theoretical capacity of LMTO, a careful selection of the additive, such as CNT, effectively reduces the required carbon quantity to achieve a higher electrode gravimetric discharge capacity.

25 ENERGY STORAGE↗

Gas Turbine Engine Inlet Wall Design

A gas turbine engine has an inlet duct formed to have a shape with a first ellipse in one half and a second ellipse in a second half. The second half has an upstream most end which is smaller than the first ellipse. The inlet duct has a surface defining the second ellipse which curves away from the first ellipse, such that the second ellipse is larger at an intermediate location. The second ellipse is even larger at a downstream end of the inlet duct leading into a fan.

Florea, Razvan Virgil↗

Hermetic seal for a shaft

An hermetic seal for a linear rod having a portion thereof projected axially through a port defined in a wall for a pressure chamber and supported thereby for omni-directional motion is described. The seal is characterized by a resilient, impervious, cylindrical body having a first section concentrically related to the shaft and integrally affixed thereto comprising a linear ordered array of annular flutes. A second section integrally is affixed to the wall of the chamber and concentrically related to the port comprising a second linear ordered array of annular flutes. A third section is interposed between the first and second sections and integrally affixed in coaxial alignment therewith comprising an annular ordered array of linear flutes concentrically related to the shaft, whereby axial, angular, and pivotal motion of the rod is accommodated.

Lombardi, F.↗

Imaging of Electrothermal Filament Formation in a Mott Insulator

Resistive switching—the current- and voltage-induced change of electrical resistance—is at the core of memristive devices, which play an essential role in the emerging field of neuromorphic computing. This study is about resistive switching in a Mott insulator, which undergoes a thermally driven metal-to-insulator transition. Two distinct switching mechanisms are reported for such a system: electric-field-driven resistive switching and electrothermal resistive switching. The latter results from an instability caused by Joule heating. Here, we present the visualization of the reversible resistive switching in a planar V 2 O 3 thin-film device using high-resolution wide-field microscopy in combination with electric transport measurements. We investigate the interaction of the electrothermal instability with the strain-induced spontaneous phase separation in the V 2 O 3 thin film at the Mott transition. The photomicrographs show the formation of a narrow metallic filament with a minimum width ≲500 nm. Although the filament formation and the overall shape of the current-voltage characteristics (IVCs) are typical of an electrothermal breakdown, we also observe atypical effects such as oblique filaments, filament splitting, and hysteretic IVCs with sawtoothlike jumps at high currents in the low-resistance regime. We are able to reproduce the experimental results in a numerical model based on a two-dimensional resistor network. This model demonstrates that resistive switching in this case is indeed electrothermal and that the intrinsic heterogeneity is responsible for the atypical effects. This heterogeneity is strongly influenced by strain, thereby establishing a link between switching dynamics and structural properties.

42 ENGINEERING↗

Electronic nature of chiral charge order in the kagome superconductor CsV 3 Sb 5

Kagome superconductors with T C up to 7 K have been discovered for over 40 y. Recently, unconventional chiral charge order has been reported in kagome superconductor KV 3 Sb 5 , with an ordering temperature of one order of magnitude higher than the T C . However, the chirality of the charge order has not been reported in the cousin kagome superconductor CsV 3 Sb 5 , and the electronic nature of the chirality remains elusive. In this paper, we report the observation of electronic chiral charge order in CsV 3 Sb 5 via scanning tunneling microscopy (STM). We observe a 2 × 2 charge modulation and a 1 × 4 superlattice in both topographic data and tunneling spectroscopy. 2 × 2 charge modulation is highly anticipated as a charge order by fundamental kagome lattice models at van Hove filling, and is shown to exhibit intrinsic chirality. We find that the 1 × 4 superlattices form various small domain walls, and can be a surface effect as supported by our first-principles calculations. Crucially, we find that the amplitude of the energy gap opened by the charge order exhibits real-space modulations, and features 2 × 2 wave vectors with chirality, highlighting the electronic nature of the chiral charge order. STM study at 0.4 K reveals a superconducting energy gap with a gap size 2Δ = 0.85 meV, which estimates a moderate superconductivity coupling strength with 2Δ/k B T C = 3.9. Furthermore, when further applying a c-axis magnetic field, vortex core bound states are observed within this gap, indicative of clean-limit superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient Thermal Energy Storage with Radial Flow in Packed Beds

Thermal energy storage (TES) is a way to store excess heat in order to generate power later. These types of systems are valuable in the solar industry, where power production can still occur when sunlight is not available. This not only increases system flexibility, it drives down the cost of electricity. One option to store thermal energy is with a packed bed where the storage media resides in a cylindrical container. Flow from one end of the cylinder to the other deposits or recovers heat (axial flow). While a promising technology in terms of energy storage, it exhibits a high pressure drop that lowers overall system efficiency. This project seeks to flow the heat transfer fluid through the storage media in the radial direction. This system offers the potential to retain reasonable thermal performance while substantially lowering the pressure drop. The overall goal was to assess the performance of radial flow experimentally and numerically. Three main designs were considered in this work. The first system utilized a central pipe and four receiving pipes near the wall. The second system utilized a central pipe and an annulus with holes near the wall. The last approach considered segmenting the bed so only select zones would receive flow in the radial direction. In a high-aspect ratio system, the hole patterns in the piping are important for ensuring even flow into the bed, and a major design effort was testing holes patterns to promote even flow. The four pipe system was shown to be not feasible, as preferential flow paths occur that do not allow even and full heating of the packed bed. The annular system can lead to even flow, but the results show this is better accomplished through larger piping instead of considering variations in the hole pattern along the axial length of the pipe. Segmenting the bed can lead to similar exergetic performance when compared to axial or radial flow. However, the pressure drop in the segmented design is likely too high for practical implementation. A baseline commercial design showed exergetic efficiencies for axial, radial, and radial segments of 81.6%, 82.8%, and 80.2%, respectively. Pressure drop for the axial and radial results were 2.36 psi and 2.45 psi, respectively, with segments being nearly an order of magnitude higher. At these large scales, the aspect ratio of the system is important. From a baseline of 0.64, an aspect ratio of 0.32 for radial flow showed an exergetic efficiency of 86% but a pressure drop of 5.39 psi. All of these results provide new insights into packed bed thermal energy storage with radial flow. Competing effects must be considered when designing a radial system, and results show a radial design can show strong thermal results at the expense of system efficiencies from pressure drop. The COMSOL models used in this analysis are available to the public and other researchers. Public benefits include a potential increase in the efficiency of packed bed thermal energy storage. Higher efficiency in storage promotes green energy technologies while reducing costs.

14 SOLAR ENERGY↗

c-HAND: near real-time coastal flood mapping

The Texas Gulf Coast region contains significant centers of population, infrastructure, and economy and is threatened by intensifying tropical storms. The flooding from these tropical storms often has multiple compounding drivers. This characteristic presents a complex numerical problem where a simulation must consider multiple hydrologic forcings. While several procedures exist for addressing this problem numerically, they tend to be resource-intensive and cannot be conducted in near real-time. We extend GeoFlood, a reduced physics approach for fluvial flood forecasting, to rapidly predict coastal and compound fluvial-coastal inundation. This method is validated against a numerical ocean circulation model (ADCIRC) simulation of Hurricane Ike, a major coastal flooding event that happened on the Texas Gulf Coast in 2008. We show that the inundation map generated by coastal HAND (c-HAND) has reasonable agreement with the ADCIRC simulation while taking about 1.7% of the time currently needed to run ADCIRC on a supercomputer. While our model correctly predicts 99% of ADCIRC-inundated DEM cells, it also overpredicts inundated area by a factor of approximately 27%. We combine c-HAND with the GeoFlood framework for fluvial flood forecasting to create a compound fluvial-coastal inundation mapping workflow that can be run in near real-time. c-HAND's fast wall-clock time and low CPU requirements can support decision making by first response personnel. The method provides timely and convenient access to crucial information, such as the locations of flooded roads and inundated coastal areas.

42 ENGINEERING↗

Propagation of high amplitude higher order sounds in slightly soft rectangular ducts, carrying mean flow

The resonance expansion method, developed to study the propagation of sound in rigid rectangular ducts is applied to the case of slightly soft ducts. Expressions for the generation and decay of various harmonics are obtained. The effect of wall admittance is seen through a dissipation function in the system of nonlinear differential equations, governing the generation of harmonics. As the wall admittance increases, the resonance is reduced. For a given wall admittance this phenomenon is stronger at higher input intensities. Both the first and second order solutions are obtained and the results are extended to the case of ducts having mean flow.

Wang, K. S.↗