Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

The size distributions of fragments ejected at a given velocity from impact craters

The mass distribution of fragments that are ejected at a given velocity for impact craters is modeled to allow extrapolation of laboratory, field, and numerical results to large scale planetary events. The model is semi-empirical in nature and is derived from: (1) numerical calculations of cratering and the resultant mass versus ejection velocity, (2) observed ejecta blanket particle size distributions, (3) an empirical relationship between maximum ejecta fragment size and crater diameter, (4) measurements and theory of maximum ejecta size versus ejecta velocity, and (5) an assumption on the functional form for the distribution of fragments ejected at a given velocity. This model implies that for planetary impacts into competent rock, the distribution of fragments ejected at a given velocity is broad, e.g., 68 percent of the mass of the ejecta at a given velocity contains fragments having a mass less than 0.1 times a mass of the largest fragment moving at that velocity. The broad distribution suggests that in impact processes, additional comminution of ejecta occurs after the upward initial shock has passed in the process of the ejecta velocity vector rotating from an initially downward orientation. This additional comminution produces the broader size distribution in impact ejecta as compared to that obtained in simple brittle failure experiments.

O'Keefe, John D.↗

Modeling-Based Design and Optimization of a Gradient Composite Transition Joint

An innovative additively manufactured gradient composite transition joint (AM-GCTJ) has been designed to join dissimilar metals, to address the pressing issue of premature failure observed in conventional dissimilar metal welds (DMWs) when subjected to increased cyclic operating conditions of fossil fuel power plants. The transition design, guided by computational modeling, developed a gradient composite material distribution, facilitating a smooth transition in material volume fraction and physical properties between different alloys. This innovative design seeks to alleviate structural challenges arising from distinct material properties, including high thermal stress and potential cracking issues resulting from the thermal expansion mismatch typically observed in conventional DMWs. In this study, we investigated the creep properties of transition joints comprising Grade 91 steel and 304 stainless steel through a combination of simulations and creep testing experiments. The implementation of a gradient composite design in the plate transition joint resulted in a significant enhancement of creep resistance when compared to the baseline conventional DMW. For instance, the creep rupture life of the transition joint was improved by > 400% in a wide range of temperature and stress testing conditions. Meanwhile, the failure location shifted to the base material of Grade 91 steel. Such enhancement can be primarily attributed to the strong mechanical constraint facilitated by the gradient composite design, which effectively reduced the stresses on the less creep-resistant alloy in the transition zone. Beyond examining plate joints, it is crucial to assess the deformation response of tubular transition joints under pressure loading and transient temperature conditions to substantiate and demonstrate the effectiveness of the design. The simulation results affirm that the tubular transition joint demonstrates superior resistance compared to its counterpart DMW when subjected to multiaxial stresses in tubular structures. In addition, optimization of the transition joint’s geometry dimensions has been conducted to diminish the accumulated deformation and enhance the service life. Lastly, the scalability and potential of the innovative transition joints for large-diameter pipe applications are addressed.

Zhang, Wei↗

Failure Analysis of T-38 Aircraft Burst Hydraulic Aileron Return Line

During maintenance troubleshooting for fluctuating hydraulic pressures, a technician found that a right hand aileron return line, on the flight hydraulic side, was ruptured (Fig. 1, 2). This tubing is part of the Hydraulic Flight Control Aileron Return Reducer to Aileron Manifold and is suspected to be original to the T-38 Talon trainer aircraft. Ailerons are small hinged sections on the outboard portion of a wing used to generate rolling motion thereby banking the aircraft. The ailerons work by changing the effective shape of the airfoil of the outer portion of the wing [1]. The drawing, Northrop P/N 3-43033-55 (6/1960), specifies that the line is made from 0.375 inch OD, aluminum 5052-0 tubing with a 0.049 inch wall thickness. WW-T-787 requires the tube shall be seamless and uniform in quality and temper [2]. The test pressure for this line is 3000 psi, and the operational pressure for this line is estimated to be between 45 psi and 1500 psi based on dynamic loading during flight. Examination of the fracture surface found evidence of arrest bands originating on the inner diameter (Fig 3). Ductile dimples are observed on the tube fractures (Fig. 4). The etched cross-section revealed thinning and work-hardening in the burst region (Fig. 5). The wall thickness just outside the work-hardened fracture region measured 0.035". Barlow's Formula: P = 2St/D, where P is burst pressure, S is allowable stress, t is wall thickness and D is the outer diameter of tube. Using the ultimate tensile strength of 28 ksi and a measured wall thickness of 0.035 inches at burst, P = 5.2 ksi (burst pressure). Using the yield of 13 ksi (YS) for aluminum 5052-0, plastic deformation will happen at P = 2.4 ksi suggesting plastic deformation occurred at a proof pressure of 3.0 ksi. Conclusion: The burst resulted from high stress, low-cycle fatigue. Evidence of arrest bands originating on the inner diameter. Fracture is predominately shear dimples, characteristic of high load ductile fractures (Fig 6). Section wall reduction in the burst region. Plastic deformation and thinning of the out-of-specification tube wall likely happened during the initial proof testing years ago. Metallography of tubing away from rupture site confirmed tubing was seamless. Based on the tube microstructure, it is likely that the initial wall thickness was about 30 % thinner than the requirement of 0.049 inches. Fracture initiated on the ID and progressed to the OD (shear lip). The tube is made of the correct material of 5052-0 aluminum as verified using Optical Emission Spectroscopy (Table 2). The tubing hardness tested 77 HV100 (77 HRE). This hardness is slightly above the requirement for 70 HRE maximum for aluminum 5052-0 in AMS 2658C [3].

Martinez, J. E.↗

Coal to Carbon Fiber (C2CF) Continuous Processing for High Value Composites (Final Report)

Coal tar is a condensed and recovered by-product of the coking of metallurgical coal for steel production. The heaviest fraction of distilled coal tar is an isotropic pitch largely used as a binder in the manufacturing of carbonaceous electrodes for primary aluminum smelting and in electric arc furnaces. Coal tar pitch offers high carbon yield upon carbonization. In this project, a process to convert the domestically sourced isotropic coal tar pitch, containing very low particulates (QI = 0.32 wt.%), to form flow-domain mesophase pitch amenable for melt spinning into precursor (green) fibers for carbon fiber, was developed and optimized. The final reproducible processing developed is reviewed in this report, along with several characterizations of the mesophase pitch. A final definition of the characteristics of a ‘spinnable’ mesophase pitch is presented. With this mesophase pitch, reproducible and stable multifilament melt spinning was developed, producing green fiber tows with filament diameters of approximately 20 m. The multifilament melt spinning was the most challenging aspect of the project and required the most effort. The best practices learned from this project for melt spinning are reviewed in this report. Once spun, the green fibers were oxidatively stabilized, carbonized and graphitized under inert gas atmosphere to form the final carbon fibers. Given the relatively high softening point of the mesophase pitch, no issues of interfilament fusion were observed during batch oxidation, and subsequent batch carbonization and graphitization went smoothly in all cases. An ~ 80 wt.% conversion of the green fiber mass to final carbon fiber was achieved. After graphitization, the carbon fibers showed high tensile moduli (most were ~ 600 GPa, or 87 Msi) consistent with commercially-available high-performance pitch-based carbon fiber. However, tensile strength and strain to failure were comparatively low. Further work to reduce defects in and on the fiber surfaces would increase these properties. SEM imaging of the graphitic fiber textures is presented herein. Rudimentary composites were fabricated from the carbon fibers and characterized showing similar modulus to baseline composites fabricated with commercial carbon fiber. Finally, a basic economic analysis was done showing the potential to increase the value of the isotropic coal tar pitch by up to 13.6 to 136 times based on a carbon fiber value of $\$$5/lb to $\$$50/lb, respectively. Moreover, the site case study suggests that the coal tar from the single integrated steel mill could supply production of up to 16 kt/yr of carbon fiber. Finally, a technological gap analysis was done which shed light on remaining technical challenges. These challenges included: recovery and utilization of condensates from the mesophase pitch processing, further advancing and increasing stability of the multifilament melt spinning processing, optimization of the oxidation processing, defect reduction for increased carbon fiber strength, and the development of a weaving process towards carbon fiber fabrics. To maximize the coal value chain, the primary objectives of this project were to (a) develop and scale efficient processing technology for producing melt-spinnable mesophase pitch from isotropic coal tar pitch, (b) clarify and simplify tedious continuous fiber processing technologies (particularly multifilament melt spinning of mesophase pitch) towards the efficient production of high performance carbon fiber, and (c) demonstrate and characterize representative composite parts derived from the final carbon fiber. Immense progress was made on all 3 objectives and is detailed in this report.

01 COAL, LIGNITE, AND PEAT↗

Flaw Tolerance Assessment for DOE Standard SNF Dry Storage Canisters - 26550

The U.S. DOE has designed four spent nuclear fuel (SNF) dry storage canisters for storing DOE standardized SNFs. The DOE standard canisters are cylindrical shells with a diameter of 24 inches (610 m) or 18 inches (457 m), a wall thickness of 0.5 inches (12.7 m) or 0.375 inches (9.53 m), and a length of 15 feet (4.57 m) or 10 feet (3.05 m). These DOE canister geometries are completely different from commercial canisters. The latter may experience chloride-induced stress cracking corrosion (CI-SCC) because they are stored near coastal regions. The former may not experience CI-SCC but face different challenges because they are stored in the SNF storage facilities. Because of large residual stresses, mechanical flaws may occur in the DOE canisters during long-distance transportation or lifting handling. To date, only limited structural integrity analyses were carried out through drop tests on the DOE canisters, but a more general flaw tolerance assessment has not been performed. Therefore, the failure assessment diagram (FAD)-based fracture mechanics method, as codified by the latest API 579-1/ASME FFS-1-2021 Edition, is adopted in this work to assess surface flaw tolerance for DOE canisters under operation loading and welding residual stresses (WRS), where the new code-recommended WRS distributions are used. To more adequately consider the transverse distribution of WRS, an equivalent WRS distribution is proposed to account for the WRS reduction with distance from the weld centerline. Moreover, the closed-form solutions of stress intensity factor K, which serves as the crack driving force during subcritical crack growth, are developed from the tabular data of the K factors provided in API 579-1/ASME FFS-1 and used to determine more accurate flaw sizes at flaw instability. Subsequently, the Level 2 assessment procedures with 12 assessment steps, as codified and detailed in API 579-1 and ASME FFS-1, are followed to assess the flaw tolerance for the surface flaws in the DOE standard canisters with consideration of normal or accident operation loads combined with WRS. The assessment results show that the four designs of DOE standard canisters can tolerate all surface flaws that meet the code permitted maximum sizes of a flaw length of 8 inches (i.e., 200 mm) and a flaw depth of 80% wall thickness. This demonstrates that all designs of DOE standard canisters are robust and reliable.

DOE standard canister↗

Flat plate puncture test convergence study.

The ASME Task Group on Computational Mechanics for Explicit Dynamics is investigating the types of finite element models needed to accurately solve various problems that occur frequently in cask design. One type of problem is the 1-meter impact onto a puncture spike. The work described in this paper considers this impact for a relatively thin-walled shell, represented as a flat plate. The effects of mesh refinement, friction coefficient, material models, and finite element code will be discussed. The actual punch, as defined in the transport regulations, is 15 cm in diameter with a corner radius of no more than 6 mm. The punch used in the initial part of this study has the same diameter, but has a corner radius of 25 mm. This more rounded punch was used to allow convergence of the solution with a coarser mesh. A future task will be to investigate the effect of having a punch with a smaller corner radius. The 25-cm thick type 304 stainless steel plate that represents the cask wall is 1 meter in diameter and has added mass on the edge to represent the remainder of the cask. The amount of added mass to use was calculated using Nelm's equation, an empirically derived relationship between weight, wall thickness, and ultimate strength that prevents punch through. The outer edge of the plate is restrained so that it can only move in the direction parallel to the axis of the punch. Results that are compared include the deflection at the edge of the plate, the deflection at the center of the plate, the plastic strains at radius r=50 cm and r=100 cm , and qualitatively, the distribution of plastic strains. The strains of interest are those on the surface of the plate, not the integration point strains. Because cask designers are using analyses of this type to determine if shell will puncture, a failure theory, including the effect of the tri-axial nature of the stress state, is also discussed. The results of this study will help to determine what constitutes an adequate finite element model for analyzing the puncture hypothetical accident.

36 MATERIALS SCIENCE↗

Transcatheter Arterial Embolization for Spontaneous Rupture of the Omental Artery

We encountered a rare case of spontaneous rupture of the omental artery. A 25-year-old man without any episode of abdominal trauma or bleeding disorders came to the emergency unit with left upper abdominal pain. Hematoma with extravasation of the greater omentum and a hemoperitoneum was confirmed on abdominal contrast-enhanced computed tomography. Bleeding from the omental artery was suspected based on these findings. Transcatheter arterial embolization was successfully performed after extravasation of the omental artery, which arises from the left gastroepiploic artery, was confirmed on arteriography. Partial ometectomy was performed 10 days after transcatheter arterial embolization, revealing that the hematoma measured 10 cm in diameter in the greater omentum. Pathological examination showed rupture of the branch of an omental artery without abnormal findings, such as an aneurysm or neoplasm. Thus, we diagnosed him with spontaneous rupture of the omental artery. The patient recovered and was discharged from the hospital 10 days after the surgery, with a favorable postoperative course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Radioactive {sup 125}I Seed Implantation Therapy of Symptomatic Retroperitoneal Lymph Node Metastases

Purpose: This study explored the clinical efficacy of CT-guided radioactive {sup 125}I seed implantation in treating patients with symptomatic retroperitoneal lymph node metastases. Methods: Twenty-five patients with pathologically confirmed malignant tumors received CT-guided radioactive {sup 125}I seed implantation to treat metastatic lymph nodes. The diameter of the metastatic lymph nodes ranged from 1.5 to 4.5 cm. Treatment planning system (TPS) was used to reconstruct the three-dimensional image of the tumor and then calculate the corresponding quantity and distribution of {sup 125}I seeds. Results: Follow-up period for this group of patients was 2–30 months, and median time was 16 months. Symptoms of refractory pain were significantly resolved postimplantation (P < 0.05), and Karnofsky score rose dramatically (P < 0.05). Most patients reported pain relief 2–5 days after treatment. Follow-up imaging studies were performed 2 months later, which revealed CR in 7 patients, PR in 13 patients, SD in 3 patients, and PD in 2 patients. The overall effective rate (CR + PR) was 80 %. Median survival time was 25.5 months. Seven patients died of recurrent tumor; 16 patients died of multiorgan failure or other metastases. Two patients survived after 30 months follow-up. Two patients reported localized skin erythema 1 week postimplantation, which disappeared after topical treatment. Conclusions: CT-guided radioactive {sup 125}I seed implantation, which showed good palliative pain relief with acceptable short-term effects, has proved in our study to be a new, safe, effective, and relatively uncomplicated treatment option for symptomatic retroperitoneal metastatic lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Joule-Thomson valves for long term service in space cryocoolers

Joule-Thomson valves for small cryocoolers have throttling passages on the order of 0.1 millimeter in diameter. Consequently, they can become plugged easily and stop the operation of the cooler. Plugging can be caused by solid particles, liquids or gases. Plugging is usually caused by the freezing of contaminant gases from the process stream. In small open loop coolers and in closed loop coolers where periodic maintenance is allowed, the problem is overcome by using careful assembly techniques, pure process gases, warm filters and cold adsorbers. A more thorough approach is required for closed loop cryocoolers which must operate unattended for long periods. This paper presents the results of an effort to solve this problem. The causes of plugging are examined, and various ways to eliminate plugging are discussed. Finally, the development of a J-T defroster is explained. It is concluded that a combination of preventive measures and a defroster will reduce the chance of cooler failure by plugging to such a degree that J-T coolers can be used for long term space missions.

Lester, J. M.↗

Foreign Object Damage Behavior of a SiC/SiC Composite at Ambient and Elevated Temperatures

Foreign object damage (FOD) behavior of a gas-turbine grade SiC/SiC ceramic matrix composite (CMC) was determined at 25 and 1316 C, employing impact velocities from 115 to 440 meters per second by 1.59-mm diameter stell-ball projectiles. Two different types of specimen support were used at each temperature: fully supported and partially supported. For a given temperature, the degree of post-impact strength degradation increased with increasing impact velocity, and was greater in a partially supported configuration than in a fully supported one. The elevated-temperature FOD resistance of the composite, particularly under partially supported loading at higher impact velocities greater than or equal to 350 meters per second, was significantly less than the ambient-temperature counterpart, attributed to a weakening effect of the composite. For fully supported loading, frontal contact stress played a major role in generating composite damage; whereas, for partially supported loading, both frontal contact and backside bending stresses were combined sources of damage generation. The SiC/SiC composite was able to survive higher energy impacts without complete structural failure but suffered more strength affecting damage from low energy impacts than AS800 and SN282 silicon nitrides.

Bhatt, Ramakrishna T.↗

Impact Resistance of EBC Coated SiC/SiC Composites

Impact performance of 2-D woven SiC/SiC composites coated with 225 and 525 m thick environmental barrier coating (EBC) was investigated. The composites were fabricated by melt infiltration and the EBC was deposited by plasma spray. Impact tests were conducted at room temperature and at 1316 C in air using 1.59-mm diameter steel-balls at projectile velocities ranging from 110 to 375 m/s. Both microscopy and nondestructive evaluation (NDE) methods were used to determine the extent of damage in the substrate and coating with increasing projectile velocity. The impacted specimens were tensile tested at room temperature to determine their residual mechanical properties. At projectile velocities less than 125 m/s, no detectable damage was noticed in the MI SiC/SiC composites coated with 525 m EBC. With increase in projectile velocity beyond this value, spallation of EBC layers, delamination of fiber plies, and fiber fracture were detected. At a fixed projectile velocity, the composites coated with 525 m EBC showed less damage than the composite coated with 225 m EBC. Both types of EBC coated composites retained a large fraction of the baseline properties of as-fabricated composites and exhibited non-brittle failure after impact testing at projectile velocities up to 375 m/s. Exposure of impact tested specimens in a moisture environment at 1316 C for 500 hr indicated that the through-the-thickness cracks in the EBC coating and delamination cracks in the substrate generated after impact testing acted as conduits for internal oxidation.

Fox, Dennis S.↗

Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS)-associated Refractory Hepatic Encephalopathy by Shunt Reduction Using the Parallel Technique: Outcomes of a Retrospective Case Series

Purpose: To investigate the reproducibility and technical and clinical success of the parallel technique of transjugular intrahepatic portosystemic shunt (TIPS) reduction in the management of refractory hepatic encephalopathy (HE). Materials and Methods: A 10-mm-diameter self-expanding stent graft and a 5-6-mm-diameter balloon-expandable stent were placed in parallel inside the existing TIPS in 8 patients via a dual unilateral transjugular approach. Changes in portosystemic pressure gradient and HE grade were used as primary end points. Results: TIPS reduction was technically successful in all patients. Mean {+-} standard deviation portosystemic pressure gradient before and after shunt reduction was 4.9 {+-} 3.6 mmHg (range, 0-12 mmHg) and 10.5 {+-} 3.9 mmHg (range, 6-18 mmHg). Duration of follow-up was 137 {+-} 117.8 days (range, 18-326 days). Clinical improvement of HE occurred in 5 patients (62.5%) with resolution of HE in 4 patients (50%). Single episodes of recurrent gastrointestinal hemorrhage occurred in 3 patients (37.5%). These were self-limiting in 2 cases and successfully managed in 1 case by correction of coagulopathy and blood transfusion. Two of these patients (25%) died, one each of renal failure and hepatorenal failure. Conclusion: The parallel technique of TIPS reduction is reproducible and has a high technical success rate. A dual unilateral transjugular approach is advantageous when performing this procedure. The parallel technique allows repeat bidirectional TIPS adjustment and may be of significant clinical benefit in the management of refractory HE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact Resistance of Environmental Barrier Coated SiC/SiC Composites

Impact performance of 2D woven SiC/SiC composites coated with 225 and 525 microns thick environmental barrier coating (EBC) was investigated. The composites were fabricated by melt infiltration and the EBC was deposited by plasma spray. Impact tests were conducted at room temperature and at 1316 C in air using 1.59 mm diameter steel-balls at projectile velocities ranging from 110 to 375 m/s . Both microscopy and non-destructive evaluation (NDE) methods were used to determine the extent of damage in the substrate and coating with increasing projectile velocity. The impacted specimens were tensile tested at room temperature to determine their residual mechanical properties. At projectile velocities less than 125 m/s , no detectable internal damage was noticed in the MI SiC/SiC composites coated with 525 microns EBC. With increase in projectile velocity beyond this value, spallation of EBC layers, delamination of fiber plies, and fiber fracture were detected. At a fixed projectile velocity, the composites coated with 525 microns EBC showed less damage than those coated with 225 microns EBC. Both types of coated composites retained a large fraction of the baseline properties of the as-fabricated composites and exhibited non-brittle failure after impact testing. Furnace exposure of impacted specimens in a moisture environment at 1316 C for 500 h indicated that the through-the-thickness cracks in the coating and delamination cracks in the substrate generated after impact testing acted as conduits for internal oxidation.

Bhatt, Ramakrishna T.↗

Inspection of the Space Shuttle External Tank SOFI Using Near-Field and Focused Millimeter Wave Nondestructive Testing Techniques

The Space Shuttle Columbia's catastrophic failure has been attributed to a piece of external tank SOFI (Spray On Foam Insulation) striking the left wing of the orbiter causing significant damage to some of the reinforced carbon/carbon leading edge wing panels. Subsequently, several nondestructive testing (NDT) techniques have been considered for inspecting the external tank. One such method involves using millimeter waves which have been shown to easily penetrate through the foam and provide high resolution images of its interior structures. This paper presents the results of inspecting three different SOFI covered panels by reflectometers at millimeter wave frequencies, specifically at 100 GHz. Each panel was fitted with various embedded anomalies/inserts representing voids and unbonds of diferent shapes, sizes and locations within each panel. In conjunction with these reJqectome&rs, radiators including a focused lens antenna and a small horn antenna were used. The focused lens antenna provided for a footprint diameter of approximately 1.25 cm (0.5") at 25.4 cm (10") away from the lens surface. The horn antenna was primarily operated in its near-field for obtaining relatively high resolution images. These images were produced using 2 0 scanning mechanisms. Discussions of the difference between the capabilities of these two types of antennas (radiators) for the purpose of inspecting the SOFI as it relates to the produced images are also presented.

Kharkovsky, S.↗

The OSIRIS-REx Spacecraft and the Touch-and-Go Sample Acquisition Mechanism (TAGSAM)

The Origins, Spectral-Interpretation, Resource-Identification, Security and Regolith- Explorer (OSIRIS-REx) spacecraft supports all aspects of the mission science objectives, from extensive remote sensing at the asteroid Bennu, to sample collection and return to Earth. In general, the success of planetary missions requires the collection, return, and analysis of data, which in turn depends on the successful operation of instruments and the host spacecraft. In the case of OSIRIS-REx, a sample-return mission, the spacecraft must also support the acquisition, safe stowage, and return of the sample. The target asteroid is Bennu, a B-class near-Earth asteroid roughly 500 m diameter. The Lockheed Martin-designed and developed OSIRIS-REx spacecraft draws significant heritage from previous missions and features the Touch-and-Go-Sample-Acquisition-Mechanism, or TAGSAM, to collect sample from the surface of Bennu. Lockheed Martin developed TAGSAM as a novel, simple way to collect samples on planetary bodies. During short contact with the asteroid surface, TAGSAM releases curation-grade nitrogen gas, mobilizing the surface regolith into a collection chamber. The contact surface of TAGSAM includes "contact pads", which are present to collect surface grains that have been subject to space weathering. Extensive 1-g laboratory testing, "reduced-gravity" testing (via parabolic flights on an airplane), and analysis demonstrate that TAGSAM will collect asteroid material in nominal conditions, and a variety of off-nominal conditions, such as the presence of large obstacles under the TAGSAM sampling head, or failure in the sampling gas firing. TAGSAM, and the spacecraft support of the instruments, are central to the success of the mission.

Spacecraft↗

Adiabatic Shear Localization and Microstructure in Ultrafine Grained Aluminum Alloy at Cryogenic Temperature

Adiabatic shear localization plays an important role in the deformation and failure of ultrafine grained 6061 aluminum alloy processed by friction stir processing. To understand the effects of temperature and strain on adiabatic shear localization in the ultrafine grained 6061 aluminum alloy, it has been investigated dynamic mechanical behavior of ultrafine grained 6061 aluminum alloy under the controlled shock loading experiments. Deformation characteristics and microstructures in the shear band were performed by optical microscopy and transmission electron microscopy. The shear band in the ultrafine grained aluminum alloy is a long and straight band distinguished from the matrix. The width of the shear band decreases with increasing nominal strain. The results show that the grains in the boundary of the shear band are highly elongated along the shear direction and form the elongated cell structures (0.2 μ in width), and the core of the shear band consists of a number of recrystallized equiaxed grains 0.2-0.3 μ in diameters and the second phases distribute in both the boundary and the inner of the equiaxed new grains. The calculated temperature in the shear band is about 692 K. Rotational dynamic recrystallization mechanism is responsible for the formation of the microstructure in the shear band.

36 MATERIALS SCIENCE↗

Vertically oriented ZrO 2 –TiO 2 –Nb 2 O 5 –Al 2 O 3 mixed nanopatterned bioceramics on Ti6Al7Nb implant assessed by laser spallation technique

Recently, reports on the fabrication of nonstructural configuration have generated scientific interest due to increased awareness of the oxide nanotubes in the biomedical implant field and other industrial approaches. In this paper, highly ordered ZrO 2 –TiO 2 –Nb 2 O 5 –Al 2 O 3 nanotube arrays were grown by physical vapor deposition (PVD) of a zirconium layer on titanium-niobium alloy implant (IMPTi67) and succeeding anodic oxidation at a constant voltage (60 V) with exposure times ranging from 30 to 300 min. To crystallize the resulting mixed oxide nanotubes, heat treatment was also applied. The nanotubes were placed in an atmospheric furnace at temperatures ranging from 450 to 800 °C for 2 h. This treatment provided a morphological evolution was strongly influenced by the anodization time, where highly aligned bamboo-shaped oxide nanotubes (161 ± 44 nm in inside diameter and ~1 μm in length) were formed after 300 min of anodization. After annealing at temperature below 500 °C, the nano-array configuration remained stable and the average inner diameter decreased to around 40 nm. The effects of anodically fabrication time on the adhesion strength of four-phase multilayered mixed oxide nanotubes on anodized Zr/IMPTi67 surfaces assed by microscratch analysis. From the results, increasing the annealing temperature further to 800 °C fully destroyed the nanotubes and consequently the tubular arrangement was converted to a coarse grain structure. It was revealed that annealing at 450 °C for 2 h was the optimum conditions for stable nanotubular array generation, where the highest adhesion strength (shifted from 2595.59 to 2640.12 mN), microhardness (372 HV) and hydrophilicity (15 ± 1°) were recorded. It is notify that the adhesion strength of highly ordered mixed nanotubes was remarkably decreased after thermal treatment at 800 °C (1817.51 mN). Through the laser spallation analysis, the intrinsic adhesion strength of the Zr/IMPTi67 interface was found to be at 63 MPa, while the first stages of failure occurred at a stress state of 35 MPa. The adhesion of the film with the tubular structure proved to have a significantly larger adhesion strength of 246 MPa for the complete failure and 203 MPa for incipient stages of spallation. Finally, the considered surface modification can be an effective step in determining the interface strength between biomedical implants and the nanostructured coatings.

36 MATERIALS SCIENCE↗

Design and evaluation of candidate pressure ports for the HYFLITE experiment

A concept for placing a pressure transducer directly in a shuttle type tile was developed at Langley Research Center. A 5 inch long quartz with a .020 inch inner diameter provides the thermal isolation necessary to allow 2800 F surface pressure measurements to be taken by pressure transducer rated at 250 F. The assembly is potted in place with RTV 560 in a piece of FRCI-12 thermal protection system insulation tile. The integrity of the thermal protection system is maintained even with the intrusion of the pressure port assembly and the pressure port does not disrupt the air flow across the lifting body. Approximately 200 of these pressure ports are to be used in each of the Hypersonic Flight Experiment (HYFLITE) flight tests. Initial vibroacoustic and aerothermal testing of the pressure port designs have been completed at Langley Research vibration laboratory and the 20 MWatt 2 x 9 turbulent duct facility at Ames Research Center. The performance of the pressure ports were found to be well within the required design limits for all cases. In addition, a failure mode in which the entire pressure port assembly was removed proved to be a begin case.

Teter, John E., Jr.↗