Charge exchange of multiply charged fluorine and lithium ions with Ne atoms

The charge exchange of multiply charged fluorine and lithium ions with Ne atoms in a gas jet was recorded from the line spectra in the 125 - 350 A range, which arise from the radiative decay of the excited states of Li II - III and F III - VIII ions populated in the charge exchange. In the F III - VI ion spectra obtained from the plasma - gas interaction region we observed transitions from levels with an open (partly filled or completely open) 2s-shell, which may be populated in sequential events of single-electron charge exchange as well as in double- and many-electron charge exchange. Partial cross sections were calculated for the single-electron charge exchange of F VIII ions with Ne atoms. By way of Hartree - Fock energy level calculations it was possible to reveal resonances between the ground states of k-fold (k = 1 - 4) ionised donor atoms and the states of k-fold excited multiply charged fluorine ion resulting from the k-fold charge exchange of F VIII ions. These resonances may be responsible for the relatively large cross sections of double- and many-electron charge exchange (laser applications and other topics in quantum electronics)

74 ATOMIC AND MOLECULAR PHYSICS↗

Electronic structure and exchange interactions in altermagnetic MnGeP 2 in the quasiparticle self-consistent G W approach

The quasiparticle self-consistent 𝐺⁡𝑊 method is used to study the electronic band structure, optical dielectric function, and exchange interactions in chalcopyrite, 𝐼⁢ ‾ 4 ⁢2⁢𝑑, structure MnGeP 2 . The material is found to be an antiferromagnetic semiconductor with a lowest direct gap of 2.44 eV at the Γ point and a lower indirect gap of 1.87 eV from Γ to 𝑀. The material is an altermagnet because the two magnetic atoms of opposite spin are related by a twofold rotation operation perpendicular to the main fourfold rotation inversion axis. The spin splittings along a low symmetry line like 𝑃⁢𝑁 is sizable while at k points on the diagonal mirror planes or on the twofold symmetry axes the spin splitting is zero. The exchange interactions are calculated using a linear response approach. The antiferromagnetic exchange interaction between nearest neighbors in the primitive unit cell is dominating and found to be slightly decreasing upon carrier doping but not sufficiently to change the interaction to become ferromagnetic. The bare (noninteracting) and interacting transverse spin susceptibilities, which provide interatomic site exchange interactions after averaging over the muffin-tin spheres, are calculated from the 𝐺⁡𝑊 band structure and wave functions. From these exchange interactions, the spin wave spectra are obtained along the high symmetry lines and the Néel temperature is calculated using the mean-field and Tyablikov estimations. The dielectric function and the optical absorption spectra are calculated including excitonic effects using the Bethe Salpeter equation. The exchange interactions around Mn Ge defect sites is also studied. While we find it can generate ferromagnetic interactions with neighboring spins, we did not find direct evidence of producing an overall ferromagnetic phase. First, if Mn antisites are introduced by exchanging Mn with a nearby Ge, the interactions stay largely antiferromagnetic. Second, when we add additional Mn, in other words in Mn-rich stoichiometry, the Mn Ge antisites produce a strong ferromagnetic interaction primarily with the Mn in the same basal plane but weaker ferromagnetic interaction with adjacent plane Mn. The interactions between regular lattice Mn stay antiferromagnetic as before and thus favor keeping the antiferromagnetic order along the [001] direction. Adding Mn antisites, however, does lead to a metallic band structure.

36 MATERIALS SCIENCE↗

THREE-DIMENSIONAL THERMAL MODELING ANALYSIS OF CST MEDIA FOR THE SMALL ION EXCHANGE PROJECT

The Small Column Ion Exchange (SCIX) project is designed to accelerate closure of High Level Waste (HLW) tanks at the Savannah River Site (SRS). The SRS tanks store HLW in three forms: sludge, saltcake, and supernate. An in-tank ion exchange process is being designed to treat supernate and dissolved saltcake waste. Through this process, radioactive cesium from the salt solution is adsorbed into Crystalline Silicotitanate (CST) ion exchange media packed within a flow-through column. A packed column loaded with radioactive cesium generates significant heat from radiolytic decay. The waste supernate solution within the ion exchange bed will boil around 120 C. Solution superheating above the boiling point within the column could lead to violent hazardous energy releases. System heating from loaded CST is also of concern in other process modules, such as the waste tank. Due to tank structural integrity concerns, the wall temperature limit for the SRS waste tanks is 100 C. The transfer of cesium-loaded CST to the tank could result in localized hot spots on the tank floor and walls which may exceed this limit. As a result, thermal modeling calculations have been conducted to predict the maximum temperatures achievable both in the column and in the waste tank. As specified in the associated Technical Task Plan, one objective of the present work was to compute temperature distributions within the ion exchange column module under accident scenarios including loss of salt solution flow through the bed and loss of coolant system flow. The column modeling domain and the scope of the calculations in this case were broadened relative to previous two-dimensional calculations to include vertical temperature distributions within the packed bed of ion exchange media as well as the upper column plenum region containing only fluid. The baseline design conditions and in-column modeling domain for the ion-exchange column module are shown in Figure 1. These evaluations assumed the maximum bounding cesium loading considered possible based on current knowledge regarding CST media and the anticipated feed compositions. Since this cesium loading was considerably higher than the nominal loading conditions in SRS waste, cases with lower loading were also evaluated. Modeling parameters were the same as those used previously unless otherwise indicated. The current model does not capture multi-phase cooling mechanisms operative when solution boiling occurs. This feature is conservative in the sense that it does not account for the large cooling effects associated with phase transfer. However, the potential transfer of heat to the plenum region associated with vertical bubble ascension through the column during boiling is also neglected. Thermal modeling calculations were also performed for the entire waste storage tank for the case where loaded and ground CST was transferred to the tank. The modeling domain used for the in-tank calculations is provided in Figure 2. The in-tank domain is based on SRS Tank 41, which is a Type-IIIA tank. Temperature distributions were evaluated for cylindrical, ground CST mounds located on the tank floor. Media grinding is required prior to vitrification processing of the CST in the SRS Defense Waste Processing Facility (DWPF). The location of the heat source region on the tank floor due to the accumulation of CST material was assumed to be just under the grinder. The shape of the CST mound was assumed to be cylindrical. This shape is believed to be most representative of the actual mound shape formed in the tank, given that submersible mixing pumps will be available for media dispersion. Alternative configurations involving other geometrical shapes for the CST mound were evaluated in the previous work. Sensitivity analysis for the in-tank region was performed for different amounts of CST media. As was the case for the in-column model, the in-tank model does not include multi-phase cooling mechanisms operative when solution boiling occurs. The in-column and the in-tank evaluations incorporated recently updated maximum cesium loading levels calculated using the current SCIX feed compositions, which resulted in significantly higher cesium loading than previously calculated. The calculations were conducted to ensure conservative predictions for the maximum temperatures achievable using the current baseline design. The degree of conservatism was reduced for in-column calculations relative to the previous work by using a three-dimensional modeling approach and selecting parameters which were nearer to expected conditions. The degree of conservatism for the in-tank calculations was also reduced by lowering the soil penetration depth below the tank from 150 to 20 feet. The primary goals of the extended thermal modeling effort were to determine whether fluid boiling or superheating are possible within the column module and to determine the maximum floor temperatures within the tank loaded with spent CST.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers

Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: (1) An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing high-moisture, low rank coals. (2) Data on typical concentrations of HCl, HNO 3 and H 2 SO 4 in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. (3) Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. (4) Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. (5) Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. (6) Condensed flue gas water treatment needs and costs. (7) Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO 2 scrubber. (8) Results of cost-benefit studies of condensing heat exchangers.

01 COAL, LIGNITE, AND PEAT↗

Heat Exchanger Intensification Through Powder Processing and Enhanced Design (HIPPED)

High intensity, supercritical CO 2 heat exchangers capable of operating at temperatures between 800 and 1100 ˚C and pressures greater than 80 bar are considered a critical component for high efficiency power generation and a range of next-generation industrial processes. A novel heat exchanger concept was proposed in this project. The proposed concept involved a plate-type architecture with three-dimensional fins, called twisted s-shaped fins, that capitalize on additive manufacturing. Four manufacturing processes were studied to realize the complex envisioned design: press and sinter of metallic powders, directed energy deposition, laser powder bed fusion, and a novel powder bed process involving a photoreactive polymer called SEAM (scalable expeditious additive manufacturing), that later was developed at MSU. The team was able to manufacture subscale heat exchangers using laser powder bed fusion (LPBF) and SEAM. The team settled on using SEAM as a final manufacturing approach due to its very low cost. The SEAM-manufactured heat exchanger, however, when tested under pressure, exhibited leaks and the process still requires further development beyond the timeline of the project. To support the heat exchanger design and testing, the team developed a new high temperature flow loop allowing testing under high temperature and pressure. Computational modeling of the heat exchanger was also performed for the twisted s-shaped fins and the computations were validated with experimental data. The new twisted fins resulted in enhanced heat transfer and reduced pressure drop. To further minimize pressure drop in the plate heat exchanger, the team also developed a simplified model for flow maldistribution in the manifolds, providing a new tool for designers that eliminates the need for complex CFD calculations. A technoeconomic analysis was also developed to contrast SEAM with LPBF, this tool indicated that SEAM is several times less costly and offer significant promises as a rapid low cost additive manufacturing process for metallic systems.

30 DIRECT ENERGY CONVERSION↗

Experimental Characterization of an Additively Manufactured Inconel 718 Heat Exchanger for High-Temperature Applications

This work presents the experimental results of a novel, air-to-air, additively manufactured manifold-microchannel heat exchanger with straight fins on both sides. The heat exchanger was made of Inconel 718 using a direct metal laser sintering technique. The overall core size of the heat exchanger was 94 mm × 87.6 mm × 94.4 mm, with a fin thickness of 0.220 mm on both the hot and cold sides. The heat exchanger was tested with pressurized nitrogen gas at 300 °C and 340 kPa for the hot side, while air at an ambient condition was used for the cold side. An overall heat transfer of 276 W/m2K was obtained for Reynolds number values of 132 and 79 for the cold and hot sides, respectively. A gravimetric heat transfer density (Q/m∆T) of 4.7–6.7 W/kgK and a volumetric heat transfer density (Q/V∆T) of 6.9–9.8 kW/m3K were recorded for this heat exchanger with a coefficient of performance value that varied from 42 to 52 over the operating conditions studied here. The experimental pressure drop results were within 10% of the numerical values, while the corresponding heat transfer results were within 17% of the numerical results, mainly due to imperfections in the fabrication process. Despite this penalty, the performance of the tested heat exchanger was superior to the conventional plate-fin heat exchangers: more than 60% of improvements in both gravimetric and volumetric heat transfer densities were recorded for the entire range of experimental data.

42 ENGINEERING↗

MULTI-SCALE MODELING AND APPROXIMATION ASSISTED OPTIMIZATION OF BARE TUBE HEAT EXCHANGERS

Air-to-refrigerant heat exchangers are very common in air-conditioning, heat pump and refrigeration applications. In these heat exchangers, there is a great benefit in terms of size, weight, refrigerant charge and heat transfer coefficient, by moving from conventional channel sizes (~ 9mm) to smaller channel sizes (< 5mm). This work investigates new designs for air-to-refrigerant heat exchangers with tube outer diameter ranging from 0.5 to 2.0mm. The goal of this research is to develop and optimize the design of these heat exchangers and compare their performance with existing state of the art designs. The air-side performance of various tube bundle configurations are analyzed using a Parallel Parameterized CFD (PPCFD) technique. PPCFD allows for fast-parametric CFD analyses of various geometries with topology change. Approximation techniques drastically reduce the number of CFD evaluations required during optimization. Maximum Entropy Design method is used for sampling and Kriging method is used for metamodeling. Metamodels are developed for the air-side heat transfer coefficients and pressure drop as a function of tube-bundle dimensions and air velocity. The metamodels are then integrated with an air-to-refrigerant heat exchanger design code. This integration allows a multi-scale analysis of air-side performance heat exchangers including air-to-refrigerant heat transfer and phase change. Overall optimization is carried out using a multi-objective genetic algorithm. The optimal designs found can exhibit 50 percent size reduction, 75 percent decrease in air side pressure drop and doubled air heat transfer coefficients compared to a high performance compact micro channel heat exchanger with same capacity and flow rates.

CFD↗

Guest Molecule Exchange Kinetics for the 2012 Ignik Sikumi Gas Hydrate Field Trial

A commercially viable technology for producing methane from natural gas hydrate reservoirs remains elusive. Short-term depressurization field tests have demonstrated the potential for producing natural gas via dissociation of the clathrate structure, but the long-term performance of the depressurization technology ultimately requires a heat source to sustain the dissociation. A decade of laboratory experiments and theoretical studies have demonstrated the exchange of pure CO2 and N2-CO2 mixtures with CH4 in sI gas hydrates, yielding critical information about molecular mechanisms, recoveries, and exchange kinetics. Findings indicated the potential for producing natural gas with little to no production of water and rapid exchange kinetics, generating sufficient interest in the guest-molecule exchange technology for a field test. In 2012 the U.S. DOE/NETL, ConocoPhillips Company, and Japan Oil, Gas and Metals National Corporation jointly sponsored the first field trial of injecting a mixture of N2-CO2 into a CH4-hydrate bearing formation beneath the permafrost on the Alaska North Slope. Known as the Ignik Sikumi #1 Gas Hydrate Field Trial, this experiment involved three stages: 1) the injection of a N2-CO2 mixture into a targeted hydrate-bearing layer, 2) a 4-day pressurized soaking period, and 3) a sustained depressurization and fluid production period. Data collected during the three stages of the field trial were made available after an extensive quality check. These data included continuous temperature and pressure logs, injected and recovered fluid compositions and volumes. The Ignik Sikumi #1 data set is extensive, but contains no direct evidence of the guest-molecule exchange process. This investigation is directed at using numerical simulation to provide an interpretation of the collected data. A numerical simulator, STOMP-HYDT-KE, was recently completed that solves conservation equations for energy, water, mobile fluid guest molecules, and hydrate guest molecules, for up to three gas hydrate guest molecules: CH4, CO2, and N2. The independent tracking of mobile fluid and hydrate guest molecules allows for the kinetic exchange of guest molecules between the mobile fluids and hydrate. The particular interest of this numerical investigation is to determine whether kinetic exchange parameters, determined from laboratory-scale experiments, are directly applicable to interpreting the Ignik Sikumi #1 data.

Alaska North Slope↗

Nanomaterials-Enhanced Electrically Switched Ion Exchange Process for Water Treatment

The objective of our work is to develop an electrically switched ion exchange (ESIX) system based on conducting polymer/carbon nanotube (CNT) nanocomposites as a new and cost-effective approach for removal of radioactive cesium, chromate, and perchlorate from contaminated groundwater. The ESIX technology combines ion exchange and electrochemistry to provide a selective, reversible method for the removal of target species from wastewater. In this technique, an electroactive ion exchange layer is deposited on a conducting substrate, and ion uptake and elution are controlled directly by modulation of the potential of the layer. ESIX offers the advantages of highly-efficient use of electrical energy combined with no secondary waste generation. Recently, we have improved upon the ESIX process by modifying the conducting substrate with carbon nanotubes prior to the deposition of the electroactive ion exchanger. The nanomaterial-based electroactive ion exchange technology will remove cesium-137, chromate, and perchlorate rapidly from wastewater. The high porosity and high surface area of the electroactive ion exchange nanocomposites results in high loading capacity and minimize interferences for non-target species. Since the ion adsorption/desorption is controlled electrically without generating a secondary waste, this electrically active ion exchange process is a green process technology that will greatly reduce operating costs.

54 ENVIRONMENTAL SCIENCES↗

Effect of Channel Configurations for Tritium Transfer in Printed Circuit Heat Exchangers

The Next Generation Nuclear Plant (NGNP), a very High temperature Gas-Cooled Reactor (VHTR) concept, will provide the first demonstration of a closed-loop Brayton cycle at a commercial scale of a few hundred megawatts electric and hydrogen production. The power conversion system (PCS) for the NGNP will take advantage of the significantly higher reactor outlet temperatures of the VHTR to provide higher efficiencies than can be achieved in the current generation of light water reactors. Besides demonstrating a system design that can be used directly for subsequent commercial deployment, the NGNP will demonstrate key technology elements that can be used in subsequent advanced power conversion systems for other Generation IV reactors. In anticipation of the design, development and procurement of an advanced power conversion system for the NGNP, the system integration of the NGNP and hydrogen plant was initiated to identify the important design and technology options that must be considered in evaluating the performance of the proposed NGNP. In the VHTR system, an intermediate heat exchanger (IHX), which transfers heat from the reactor core to the electricity or hydrogen production system is one key component, and its effectiveness is directly related to the system overall efficiency. In the VHTRs, the gas fluids used for coolant generally have poor heat transfer capability, so it requires very large surface area for a given condition. For this reason, a compact heat exchanger (CHE), which is widely used in industry especially for gasto-gas or gas-to-liquid heat exchange is considered as a potential candidate for an IHX replacing the classical shell and tube type heat exchanger. A compact heat exchanger is arbitrary referred to be a heat exchanger having a surface area density greater than 700 m2/m3. The compactness is usually achieved by fins and micro-channels, and leads to the enormous heat transfer enhancement and size reduction. The surface area density is the total heat transfer area divided by the volume of the heat exchanger. In the case of PCHE units, the heat transfer surface area density may be as high as 2,500 m2/m3. This high compactness implies an appreciable reduction in material reducing cost. In this study, heat transfer and tritium penetration analyses have been performed for two different channel configurations of the PCHE; (1) standard and (2) off-set. One of the goals of this study was to determine whether offsetting the hot and cold streams would significantly reduce the tritium flux, and whether or not it would affect the heat transfer significantly.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Selectivity, Kinetics, and Efficiency of Reversible Anion Exchange with TcO 4 - in a Supertetrahedral Cationic Framework

[ThB5O6(OH)6][BO(OH)2]·2.5H2O (Notre Dame Thorium Borate-1, NDTB-1) is an inorganic supertetrahedral cationic framework material that is derived from boric acid flux reactions. NDTB-1 exhibits facile single crystal to single crystal anion exchange with a variety of common anions such as Cl-, Br-, NO3-, IO3-, ClO4-, MnO4-, and CrO42-. More importantly, NDTB-1 is selective for the removal of TcO4- from nuclear waste streams even though there are large excesses of competing anions such as Cl-, NO3-, and NO2-. Competing anion exchange experiments and magic-angle spinning (MAS)-NMR spectroscopy of anion-exchanged NDTB-1 demonstrate that this unprecedented selectivity originates from the ability of NDTB-1 to trap TcO4- within cavities, whereas others remain mobile within channels in the material. The exchange kinetics of TcO4- in NDTB-1 are second-order with the rate constant k2 of 0.059 s-1 M-1. The anion exchange capacity of NDTB-1 for TcO4- is 162.2 mg g-1 (0.5421 mol mol-1) with a maximum distribution coefficient Kd of 1.0534 × 104 mL g-1. Finally, it is demonstrated that the exchange for TcO4- in NDTB-1 is reversible. TcO4- trapped in NDTB-1 can be exchanged out using higher-charged anions with a similar size such as PO43- and SeO42-, and therefore the material can be easily recycled and reused.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Regio-Selective Intramolecular Hydrogen/Deuterium Exchange in Gas-Phase Electron Transfer Dissociation

Protein backbone amide hydrogen/deuterium exchange mass spectrometry (HDX-MS) typically utilizes enzymatic digestion after the exchange reaction and before MS analysis to improve data resolution. Gas-phase fragmentation of a peptic fragment prior to MS analysis is a promising technique to further increase the resolution. The biggest technical challenge for this method is elimination of intramolecular hydrogen/deuterium exchange (scrambling) in the gas phase. The scrambling obscures the location of deuterium. Jørgensen’s group pioneered a method to minimize the scrambling in gas-phase electron capture/transfer dissociation. Despite active investigation, the mechanism of hydrogen scrambling is not well-understood. The difficulty stems from the fact that the degree of hydrogen scrambling depends on instruments, various parameters of mass analysis, and peptide analyzed. In most hydrogen scrambling investigations, the hydrogen scrambling is measured by the percentage of scrambling in a whole molecule. This paper demonstrates that the degree of intramolecular hydrogen/deuterium exchange depends on the nature of exchangeable hydrogen sites. The deuterium on Tyr amide of neurotensin (9–13), Arg-Pro-Tyr-Ile-Leu, migrated significantly faster than that on Ile or Leu amides, indicating the loss of deuterium from the original sites is not mere randomization of hydrogen and deuterium but more site-specific phenomena. This more precise approach may help understand the mechanism of intramolecular hydrogen exchange and provide higher confidence for the parameter optimization to eliminate intramolecular hydrogen/deuterium exchange during gas-phase fragmentation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Life cycle assessment of novel heat exchanger for dry cooling of power plants based on encapsulated phase change materials

Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polymer heat exchanger design for condensing boiler applications

Condensing boilers achieve very high efficiency levels by recovering both sensible heat and water vapor latent heat from the flue gas. Research since the 1980's has focused on corrosion in such condensing heat exchangers related to the acidic condensate and material selection. Polymers in condensing heat exchangers have been considered to avoid the cost and corrosion concerns of metallic designs. Past efforts have shown that polymers offer the advantage of corrosion resistance and cost, however, lower thermal conductivity limited their application. More recent developments have introduced thermally conductive polymers which now offer promising conductivity values. This project focused on the evaluation of a thermally conductive polymer heat exchanger for this application. Computational fluid dynamic results indicated thermal conductivity values of stainless steel, a typical heat exchanger material, do not need to be achieved for similar heat transfer performance. An increase in thermal conductivity from about 10 times that of the base polymer can achieve an overall heat exchanger effectiveness similar to that achieved with stainless steel. A polymer composite thermal conductivity of approximately 2.5 W/m∙K would be adequate. Thermally conductive polymer materials are now commercially available which offer values up to 20 W/m∙K. In this work, one Nylon-12 and one thermally conductive polymer composite heat exchanger prototypes were constructed for a condensing boiler application. In conclusion, tests demonstrated that good overall heat transfer performance was achieved. The lower thermal conductivity of the polymer heat exchanger will lead to higher surface temperatures and lower water condensation rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synthesis, characterization and evaluation of nano-zirconium vanadate ion exchanger by using three different preparation techniques

Sol-gel, homogeneous precipitation and hydrothermal synthesis are three different preparation techniques have been used as an attempt to synthesize nano-zirconium vanadate with properties suitable to be used as ion exchangers. The impact of the synthetic preparation variables such as the reactant concentrations, reaction temperature and reaction time on the ion exchange capacity of the produced ion exchanger has been considered for each preparation technique. One sample from each preparation technique having the largest ion exchange capacity has been selected to be physically and chemically characterized using various analytical techniques such as XRD, TGA, DSC, pH titration, FTIR and SEM in order to determine the properties of the ion exchanger produced from each technique. For all the studied ZrV samples it can be presumed that they have the ion exchange affinity sequences for alkali metal ions K > Na > Li, the order for the alkaline earth metals is Ba > Ca > Mg and their affinity for radioactive metals follow Cs > Sr. Moreover, the prepared materials are of high thermal and radiation stabilities. Also they have high chemical stabilities toward wide concentration ranges of acid, basic as well as polar solvents. It has been deduced from the X-ray analysis that ZrV produced from the sol-gel technique has an amorphous structural. While those produced from the homogeneous precipitation and hydrothermal synthesis techniques, in the nano-scale have semi-crystalline structural. Furthermore, SEM confirms that particle size of the all studied prepared ZrV samples have nano-diameters of range 50-60 nm. Specific surface area of the three different prepared ion exchangers are found to be equal to 187, 192 and 320 m{sup 2}/g for sol-gel, homogeneous precipitation and hydrothermal, respectively. A tentative structural formula of Zr(OH){sub 2}(HVO{sub 4}){sub 2}.2H{sub 2}O has been proposed for all studied samples on the basis of on FTIR, DSC and TGA results.

36 MATERIALS SCIENCE↗

Toxicodynamics of rigid polystyrene microparticles on pulmonary gas exchange in mice: Implications for microemboli-based drug delivery systems

The toxicodynamic relationship between the number and size of pulmonary microemboli resulting from uniformly sized, rigid polystyrene microparticles (MPs) administered intravenously and their potential effects on pulmonary gas exchange were investigated. CD-1 male mice (6–8 weeks) were intravenously administered 10, 25 and 45 μm diameter MPs. Oxygen hemoglobin saturation in the blood (SpO{sub 2}) was measured non-invasively using a pulse oximeter while varying inhaled oxygen concentration (F{sub I}O{sub 2}). The resulting data were fit to a physiologically based non-linear mathematical model that estimates 2 parameters: ventilation–perfusion ratio (V{sub A}/Q) and shunt (percentage of deoxygenated blood returning to systemic circulation). The number of MPs administered prior to a statistically significant reduction in normalized V{sub A}/Q was dependent on particle size. MP doses that resulted in a significant reduction in normalized V{sub A}/Q one day post-treatment were 4000, 40,000 and 550,000 MPs/g for 45, 25 and 10 μm MPs, respectively. The model estimated V{sub A}/Q and shunt returned to baseline levels 7 days post-treatment. Measuring SpO{sub 2} alone was not sufficient to observe changes in gas exchange; however, when combined with model-derived V{sub A}/Q and shunt early reversible toxicity from pulmonary microemboli was detected suggesting that the model and physical measurements are both required for assessing toxicity. Moreover, it appears that the MP load required to alter gas exchange in a mouse prior to lethality is significantly higher than the anticipated required MP dose for effective drug delivery. Overall, the current results indicate that the microemboli-based approach for targeted pulmonary drug delivery is potentially safe and should be further explored. -- Highlights: ► Murine pulmonary gas exchange after microembolization was non-invasively studied. ► A physiologically based model quantified impairment of pulmonary gas exchange. ► Number and size of microemboli determine severity of impaired gas exchange. ► Pulmonary gas exchange returns to baseline within 7 days.

60 APPLIED LIFE SCIENCES↗

In Situ Cs and H Exchange into Gaidonnayite and Proposed Mechanisms of Ion Diffusion

Here, the microporous mineral gaidonnayite Na 2 ZrSi 3 O 9 ·2H 2 O was studied to better understand its ion-exchange mechanisms, specifically for Cs + and H + ions. In situ Raman spectroscopy, in situ X-ray diffraction (XRD), simultaneous thermogravimetric analysis and differential scanning calorimetry (TGA/DSC), and in situ X-ray fluorescence were used to determine the exchange processes involved. The Raman spectra contain strong peaks that can be attributed to the vibrational modes for the 3MR symmetric stretch at 500 cm –1 , Si–O–Zr–O chain stretches at 938 cm –1 , and Si–O stretching in the 1000–1100 cm –1 range. The most prominent Raman shift during ion exchange is found near the 520 cm –1 peak, which corresponds to distortions of the 3MR substructure of gaidonnayite. In all instances of this study, the 3MR exhibited the highest amount of distortion during ion exchange, and the evolution of this distortion is compared to unit-cell changes as measured from XRD data and elemental changes via XRF. The correlations between the Raman, XRD, and XRF data show rapid deformation of the 3MR during the onset of H + ion exchange in the Na form of gaidonnayite. Even when unit-cell volume changes were small (<3 Å 3 ) as in the cases for Cs + into Na-gaidonnayite and Cs + into H-gaidonnayite, significant changes in the ≈520 cm –1 peak were measured. By comparing XRD data and Raman data, and verifying the cation uptake by XRF, we were able to identify and confirm conformational changes and distortions in the crystal structure before, during, and after Cs + and H + exchange. Finally, Cs exchange occurred the fastest and with the greatest capacity when starting in the H-form at room temperature, and at elevated temperatures when starting in the Na-form.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inelastic Neutron Scattering Study of Magnetic Exchange Pathways in MnS

We report an investigation of the magnetic structure and magnetic exchange pathways in MnS via neutron scattering methods, aided by density functional theory (DFT) modeling. The material has been confirmed to undergo antiferromagnetic (AFM) ordering at 152 K, with the magnetic structure representing AFM stacking of ferromagnetic (FM) (111) planes of Mn magnetic moments. Correspondingly, the magnetic structure is described by a propagation vector k = (1/2, 1/2, 1/2), with the volume of the magnetic unit cell being 8 times larger than the volume of the nuclear unit cell. Analysis of inelastic neutron scattering (INS) data collected on a powder sample of MnS revealed that the next-nearest-neighbor magnetic exchange constant (J 2 ) exceeds the nearest-neighbor exchange constant (J 1 ) by more than 3 times, while in the case of MnO, which exhibits the same nuclear and magnetic structures as MnS, the J 2 /J 1 ratio was reported to be below 1.5. Although for MnO the signs of both J 1 and J 2 indicated AFM exchange interactions, machine-learning INS data analysis in combination with DFT calculations suggests that the INS data collected on MnS are best described with J 1 < 0 and J 2 > 0, corresponding to FM and AFM exchange couplings, respectively. To achieve a satisfactory fit to the experimentally observed data, the Hamiltonian used to model the INS spectra also included the next-next-nearest-neighbor magnetic exchange constant (J 3 ). The best-fit model has been obtained with the values of the exchange constants J 1 = -0.27 meV, J 2 = 1.05 meV, and J 3 = -0.19 meV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗