Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Reduced carbon emission estimates from fossil fuel combustion and cement production in China

Nearly three-quarters of the growth in global carbon emissions from the burning of fossil fuels and cement production between 2010 and 2012 occurred in China. Yet estimates of Chinese emissions remain subject to large uncertainty; inventories of China’s total fossil fuel carbon emissions in 2008 differ by 0.3 gigatonnes of carbon, or 15 per cent. The primary sources of this uncertainty are conflicting estimates of energy consumption and emission factors, the latter being uncertain because of very few actual measurements representative of the mix of Chinese fuels. Here we re-evaluate China’s carbon emissions using updated and harmonized energy consumption and clinker production data and two new and comprehensive sets of measured emission factors for Chinese coal. We find that total energy consumption in China was 10 per cent higher in 2000–2012 than the value reported by China’s national statistics, that emission factors for Chinese coal are on average 40 per cent lower than the default values recommended by the Intergovernmental Panel on Climate Change, and that emissions from China’s cement production are 45 per cent less than recent estimates. Altogether, our revised estimate of China’s CO 2 emissions from fossil fuel combustion and cement production is 2.49 gigatonnes of carbon (2 standard deviations = ±7.3 per cent) in 2013, which is 14 per cent lower than the emissions reported by other prominent inventories. Over the full period 2000 to 2013, our revised estimates are 2.9 gigatonnes of carbon less than previous estimates of China’s cumulative carbon emissions. Our findings suggest that overestimation of China’s emissions in 2000–2013 may be larger than China’s estimated total forest sink in 1990–2007 (2.66 gigatonnes of carbon) or China’s land carbon sink in 2000–2009 (2.6 gigatonnes of carbon).

54 ENVIRONMENTAL SCIENCES↗

Explicit approximations to estimate the perturbative diffusivity in the presence of convectivity and damping. I. Semi-infinite slab approximations

In this paper, a number of new approximations are introduced to estimate the perturbative diffusivity (χ), convectivity (V), and damping (τ) in cylindrical geometry. For this purpose, the harmonic components of heat waves induced by localized deposition of modulated power are used. The approximations are based on semi-infinite slab approximations of the heat equation. The main result is the approximation of χ under the influence of V and τ based on the phase of two harmonics making the estimate less sensitive to calibration errors. To understand why the slab approximations can estimate χ well in cylindrical geometry, the relationships between heat transport models in slab and cylindrical geometry are studied. In addition, the relationship between amplitude and phase with respect to their derivatives, used to estimate χ, is discussed. The results are presented in terms of the relative error for the different derived approximations for different values of frequency, transport coefficients, and dimensionless radius. The approximations show a significant region in which χ, V, and τ can be estimated well, but also regions in which the error is large. Also, it is shown that some compensation is necessary to estimate V and τ in a cylindrical geometry. On the other hand, errors resulting from the simplified assumptions are also discussed showing that estimating realistic values for V and τ based on infinite domains will be difficult in practice. This paper is the first part (Part I) of a series of three papers. In Part II and Part III, cylindrical approximations based directly on semi-infinite cylindrical domain (outward propagating heat pulses) and inward propagating heat pulses in a cylindrical domain, respectively, will be treated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the estimation of the local dark matter density using the rotation curve of the Milky Way

The rotation curve of the Milky Way is commonly used to estimate the local dark matter density ρDM,⊙. However, the estimates are subject to the choice of the distribution of baryons needed in this type of studies. In this work we explore several Galactic mass models that differ in the distribution of baryons and dark matter, in order to determine ρDM,⊙. For this purpose we analyze the precise circular velocity curve measurement of the Milky Way up to ~ 25 kpc from the Galactic centre obtained from Gaia DR2 [1]. We find that the estimated value of ρDM,⊙ stays robust to reasonable changes in the spherical dark matter halo. However, we show that ρDM,⊙ is affected by the choice of the model for the underlying baryonic components. In particular, we find that ρDM,⊙ is mostly sensitive to uncertainties in the disk components of the Galaxy. We also show that, when choosing one particular baryonic model, the estimate of ρDM,⊙ has an uncertainty of only about 10% of its best-fit value, but this uncertainty gets much bigger when we also consider the variation of the baryonic model. In particular, the rotation curve method does not allow to exclude the presence of an additional very thin component, that can increase ρDM,⊙ by more than a factor of 8 (the thin disk could even be made of dark matter). Therefore, we conclude that exclusively using the rotation curve of the Galaxy is not enough to provide a robust estimate of ρDM,⊙. For all the models that we study without the presence of an additional thin component, our resulting estimates of the local dark matter density take values in the range ρDM,⊙ ≃ 0.3–0.4 GeV/cm 3 , consistent with many of the estimates in the literature.

79 ASTRONOMY AND ASTROPHYSICS↗

DESI DR1 Ly α 1D power spectrum: Validation of estimators

The Data Release 1 (DR1) of the Dark Energy Spectroscopic Instrument (DESI) is the largest sample to date for small-scale Lyα forest cosmology, accessed through its one-dimensional power spectrum (P 1D ). The Lyα forest P 1D is extracted from quasar spectra that are highly inhomogeneous (both in wavelength and between quasars) in noise properties due to intrinsic properties of the quasar, atmospheric and astrophysical contamination, and also sensitive to low-level details of the spectral extraction pipeline. We employ two estimators in DR1 analysis to measure P 1D : the optimal estimator and the fast Fourier transform (FFT) estimator. To ensure robustness of our DR1 measurements, we validate these two power spectrum and covariance matrix estimation methodologies against the challenging aspects of the data. First, using a set of 20 synthetic 1D realizations of DR1, we derive the masking bias corrections needed for the FFT estimator and the continuum fitting bias needed for both estimators. We demonstrate that both estimators, including their covariances, are unbiased with these corrections using the Kolmogorov-Smirnov test. Second, we substantially extend our previous suite of CCD image simulations to include 675,000 quasars, allowing us to accurately quantify the pipeline's performance. This set of simulations reveals biases at the highest k values, corresponding to a resolution error of a few percent. We base the resolution systematics error budget of DR1 P 1D on these values, but do not derive corrections from them since the simulation fidelity is insufficient for precise corrections.

Lyman alpha forest↗

Local Group timing argument and virial theorem mass estimators from cosmological simulations

ABSTRACT We identify Local Group (LG) analogues in the IllustrisTNG cosmological simulation, and use these to study two-mass estimators for the LG: One based on the timing argument (TA) and one based on the virial theorem (VT). Including updated measurements of the Milky Way-M31 tangential velocity and the cosmological constant, we show that the TA mass estimator slightly overestimates the true median LG-mass, though the ratio of the TA to the true mass is consistent at the approximate 90 per cent c.l.. These are in broad agreement with previous results using dark matter-only simulations. We show that the VT estimator better estimates the true LG-mass, though there is a larger scatter in the virial mass to true mass ratio relative to the corresponding ratio for the TA. We attribute the broader scatter in the VT estimator to several factors, including the predominantly radial orbits for LG satellite galaxies, which differs from the VT assumption of isotropic orbits. With the systematic uncertainties we derive, the updated measurements of the LG mass at 90 per cent c.l. are $4.75_{-2.41}^{+2.22} \times 10^{12}$ M⊙ from the TA and $2.0_{-1.5}^{+2.1} \times 10^{12}$ M⊙ from the VT. We consider the LMC’s effect on the TA and VT LG mass estimates, and do not find exact LMC–MW–M31 analogues in the Illustris simulations. However, in LG simulations with satellite companions as massive as the LMC, we find that the effect on the TA and VT estimators is small, though we need further studies on a larger sample of LMC–MW–M31 systems to confirm these results.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate shear estimation with fourth-order moments

ABSTRACT As imaging surveys progress in exploring the large-scale structure of the Universe through the use of weak gravitational lensing, achieving sub-per cent accuracy in estimating shape distortions caused by lensing, or shear, is imperative for precision cosmology. In this paper, we extend the Fourier power function shapelets (FPFS) shear estimator using fourth-order shapelet moments and combine it with the original second-order shear estimator to reduce galaxy shape noise. We calibrate this novel shear estimator analytically to a sub-per cent level-accuracy using the AnaCal framework. This higher order shear estimator is tested with realistic image simulations, and after analytical correction for the detection/selection bias and noise bias, the multiplicative shear bias $|m|$ is below $3\times 10^{-3}$ (99.7 per cent confidence interval) for both isolated and blended galaxies. Once combined with the second-order FPFS shear estimator, the shape noise is reduced by $\sim 35~{{\ \rm per\ cent}}$ for isolated galaxies in simulations with Hyper Suprime-Cam and Vera C. Rubin Observatory Legacy Survey of Space and Time observational conditions. However, for blended galaxies, the effective number density does not significantly improve with the combination of the two estimators. Based on these results, we recommend exploration of how this framework can further reduce the systematic uncertainties in shear due to point spread function leakage and modelling error, and potentially provide improved precision in shear inference in high-resolution space-based images.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimating Am-241 activity in the body: comparison of direct measurements and radiochemical analyses

The assessment of dose and ultimately the health risk from intakes of radioactive materials begins with estimating the amount actually taken into the body. An accurate estimate provides the basis to best assess the distribution in the body, the resulting dose, and ultimately the health risk. This study continues the time-honored practice of evaluating the accuracy of results obtained using in vivo measurement methods and techniques. Results from the radiochemical analyses of the 241Am activity content of tissues and organs from four donors to the United States Transuranium and Uranium Registries were compared to the results from direct measurements of radioactive material in the body performed in vivo and post mortem. Two were whole body donations and two were partial body donations The skeleton was the organ with the highest deposition of 241Am activity in all four cases. The activities ranged from 30 Bq to 300 Bq. The skeletal estimates obtained from measurements over the forehead were within 20% of the radiochemistry results in three cases and differed by 78% in one case. The 241Am lung activity estimates ranged from 1 Bq to 30 Bq in the four cases. The results from the direct measurements were within 40% of the radiochemistry results in 3 cases and within a factor of 3 for the other case. The direct measurement estimates of liver activity ranged from 2 Bq to 60 Bq and were generally lower than the radiochemistry results. The results from this study suggest that the measurement methods and calibration techniques used at the In Vivo Radiobioassay and Research Facility to quantify the activity in the lungs, skeleton and liver are reasonable under the most challenging conditions where there is 241Am activity in multiple organs. These methods and techniques are comparable to those used at other Department of Energy sites. This suggests that the current in vivo methods and calibration techniques provide reasonable estimates of radioactive material in the body. Not unexpectedly, there can be significant uncertainty in the estimates especially when activity is also present in other organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved estimation of cluster mass profiles from the cosmic microwave background

We develop a new method for reconstructing cluster-mass profiles and large-scale structure from the cosmic microwave background (CMB). By analyzing the likelihood of CMB lensing, we analytically prove that standard quadratic estimators for CMB lensing are unbiased and achieve the optimal condition only in the limit of no lensing; they become progressively biased and suboptimal, when the lensing effect is large, especially for clusters that can be found by ongoing Sunyaev-Zel'dovich surveys. Adopting an alternative approach to the CMB likelihood, we construct a new maximum likelihood estimator that utilizes delensed CMB temperature fields based on an assumed model. We analytically show that this estimator asymptotically approaches the optimal condition as our assumed model is refined, and we numerically show that as we iteratively apply it to CMB maps our estimator quickly converges to the true model with a factor of 10 less number of clusters than standard quadratic estimators need. For realistic CMB experiments, we demonstrate the applicability of the maximum likelihood estimator with tests against numerical simulations in the presence of CMB secondary contaminants. With significant improvement on the signal-to-noise ratio, our new maximum likelihood estimator can be used to measure the cluster-mass cross-correlation functions at different redshifts, probing the evolution of dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Real space estimator for the weak lensing convergence from the CMB

We propose an estimator defined in real space for the reconstruction of the weak lensing potential due to the intervening large-scale structure from high resolution maps of the cosmic microwave background. This estimator was motivated as an alternative to the quadratic estimator in harmonic space to surpass the difficulties of the analysis of maps containing galactic cuts and point source excisions. Using maps synthesized by pixel remapping, we implement the estimator for two experiments, namely, one in the absence and one in the presence of detector noise, and compare the reconstruction of the convergence field with that obtained with the quadratic estimator defined in harmonic space. We find good agreement between the input and the reconstructed power spectra using the proposed real space estimator. We discuss interesting features of the real space estimator and future extensions of this work.

79 ASTRONOMY AND ASTROPHYSICS↗

General CMB and primordial bispectrum estimation: Mode expansion, map making, and measures of F{sub NL}

We present a detailed implementation of two parallel bispectrum estimation methods which can be applied to general nonseparable primordial and cosmic microwave background (CMB) bispectra. The method exploits bispectrum mode decompositions on the tetrahedral domain of allowed wave number or multipole values, using both separable basis functions and related orthonormal modes. We provide concrete examples of such modes constructed from symmetrized tetrahedral polynomials, demonstrating the rapid convergence of expansions describing nonseparable bispectra. We use these modes to create rapid and robust pipelines for generating simulated CMB maps of high resolution (l>2000) given an arbitrary primordial power spectrum and bispectrum or an arbitrary late-time CMB angular power spectrum and bispectrum. By extracting coefficients for the same separable basis functions from an observational map, we are able to present an efficient f{sub NL} estimator for a given theoretical model with a nonseparable bispectrum. The estimator has two manifestations, comparing the theoretical and observed coefficients at either primordial or late times, thus encompassing a wider range of models, including secondary anisotropies and lensing as well as active models, such as cosmic strings. We provide examples and validation of both f{sub NL} estimation methods by direct comparison with simulations in a WMAP-realistic context. In addition, we demonstrate how the full primordial and CMB bispectrum can be extracted from observational maps using these mode expansions, irrespective of the theoretical model under study. We also propose a universal definition of the bispectrum parameter F{sub NL}, so that the integrated bispectrum on the observational domain can be more consistently compared between theoretical models. We obtain WMAP5 estimates of f{sub NL} for the equilateral model from both our primordial and late-time estimators which are consistent with each other, as well as results already published in the literature. These general bispectrum estimation methods should prove useful for non-Gaussianity analysis with the Planck satellite data, as well as in other contexts.

79 ASTRONOMY AND ASTROPHYSICS↗

A Hybrid Method to Estimate Specific Differential Phase and Rainfall With Linear Programming and Physics Constraints

A hybrid method of combining linear programming (LP) and physical constraints is developed to estimate specific differential phase (K DP ) and to improve rain estimation. Moreover, the hybrid K DP estimator and the existing estimators of LP, least squares fitting, and a self-consistent relation of polarimetric radar variables are evaluated and compared using simulated data. Our simulation results indicate the new estimator's superiority, particularly in regions where backscattering phase (δ hv ) dominates. Further, a quantitative comparison between auto-weather-station rain-gauge observations and K DP -based radar rain estimates for a Meiyu event also demonstrate the superiority of the hybrid K DP estimator over existing methods.

54 ENVIRONMENTAL SCIENCES↗

Bootstrapping outperforms community‐weighted approaches for estimating the shapes of phenotypic distributions

Abstract Estimating phenotypic distributions of populations and communities is central to many questions in ecology and evolution. These distributions can be characterized by their moments (mean, variance, skewness and kurtosis) or diversity metrics (e.g. functional richness). Typically, such moments and metrics are calculated using community‐weighted approaches (e.g. abundance‐weighted mean). We propose an alternative bootstrapping approach that allows flexibility in trait sampling and explicit incorporation of intraspecific variation, and show that this approach significantly improves estimation while allowing us to quantify uncertainty. We assess the performance of different approaches for estimating the moments of trait distributions across various sampling scenarios, taxa and datasets by comparing estimates derived from simulated samples with the true values calculated from full datasets. Simulations differ in sampling intensity (individuals per species), sampling biases (abundance, size), trait data source (local vs. global) and estimation method (two types of community‐weighting, two types of bootstrapping). We introduce the traitstrap R package, which contains a modular and extensible set of bootstrapping and weighted‐averaging functions that use community composition and trait data to estimate the moments of community trait distributions with their uncertainty. Importantly, the first function in the workflow, trait_fill , allows the user to specify hierarchical structures (e.g. plot within site, experiment vs. control, species within genus) to assign trait values to each taxon in each community sample. Across all taxa, simulations and metrics, bootstrapping approaches were more accurate and less biased than community‐weighted approaches. With bootstrapping, a sample size of 9 or more measurements per species per trait generally included the true mean within the 95% CI. It reduced average percent errors by 26%–74% relative to community‐weighting. Random sampling across all species outperformed both size‐ and abundance‐biased sampling. Our results suggest randomly sampling ~9 individuals per sampling unit and species, covering all species in the community and analysing the data using nonparametric bootstrapping generally enable reliable inference on trait distributions, including the central moments, of communities. By providing better estimates of community trait distributions, bootstrapping approaches can improve our ability to link traits to both the processes that generate them and their effects on ecosystems.

Maitner, Brian S.↗

NMR Logging to Estimate Hydraulic Conductivity in Unconsolidated Aquifers

Abstract Nuclear magnetic resonance ( NMR ) logging provides a new means of estimating the hydraulic conductivity ( K ) of unconsolidated aquifers. The estimation of K from the measured NMR parameters can be performed using the Schlumberger‐Doll Research ( SDR ) equation, which is based on the Kozeny–Carman equation and initially developed for obtaining permeability from NMR logging in petroleum reservoirs. The SDR equation includes empirically determined constants. Decades of research for petroleum applications have resulted in standard values for these constants that can provide accurate estimates of permeability in consolidated formations. The question we asked: Can standard values for the constants be defined for hydrogeologic applications that would yield accurate estimates of K in unconsolidated aquifers? Working at 10 locations at three field sites in Kansas and Washington, USA, we acquired NMR and K data using direct‐push methods over a 10‐ to 20‐m depth interval in the shallow subsurface. Analysis of pairs of NMR and K data revealed that we could dramatically improve K estimates by replacing the standard petroleum constants with new constants, optimal for estimating K in the unconsolidated materials at the field sites. Most significant was the finding that there was little change in the SDR constants between sites. This suggests that we can define a new set of constants that can be used to obtain high resolution, cost‐effective estimates of K from NMR logging in unconsolidated aquifers. This significant result has the potential to change dramatically the approach to determining K for hydrogeologic applications.

Knight, Rosemary↗

Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake

Estimating organ residence times is an essential part of patient-specific dosimetry for radioimmunotherapy (RIT). Quantitative imaging methods for RIT are often evaluated using a single physical or simulated phantom but are intended to be applied clinically where there is variability in patient anatomy, biodistribution, and biokinetics. To provide a more relevant evaluation, the authors have thus developed a population of phantoms with realistic variations in these factors and applied it to the evaluation of quantitative imaging methods both to find the best method and to demonstrate the effects of these variations. Using whole body scans and SPECT/CT images, organ shapes and time-activity curves of 111In ibritumomab tiuxetan were measured in dosimetrically important organs in seven patients undergoing a high dose therapy regimen. Based on these measurements, we created a 3D NURBS-based cardiac-torso (NCAT)-based phantom population. SPECT and planar data at realistic count levels were then simulated using previously validated Monte Carlo simulation tools. The projections from the population were used to evaluate the accuracy and variation in accuracy of residence time estimation methods that used a time series of SPECT and planar scans. Quantitative SPECT (QSPECT) reconstruction methods were used that compensated for attenuation, scatter, and the collimator-detector response. Planar images were processed with a conventional (CPlanar) method that used geometric mean attenuation and triple-energy window scatter compensation and a quantitative planar (QPlanar) processing method that used model-based compensation for image degrading effects. Residence times were estimated from activity estimates made at each of five time points. The authors also evaluated hybrid methods that used CPlanar or QPlanar time-activity curves rescaled to the activity estimated from a single QSPECT image. The methods were evaluated in terms of mean relative error and standard deviation of the relative error in the residence time estimates taken over the phantom population. The mean errors in the residence time estimates over all the organs were <9.9% (pure QSPECT), <13.2% (pure QPLanar), <7.2% (hybrid QPlanar/QSPECT), <19.2% (hybrid CPlanar/QSPECT), and 7%-159% (pure CPlanar). The standard deviations of the errors for all the organs over all the phantoms were <9.9%, <11.9%, <10.8%, <22.0%, and <107.9% for the same methods, respectively. The processing methods differed both in terms of their average accuracy and the variation of the accuracy over the population of phantoms, thus demonstrating the importance of using a phantom population in evaluating quantitative imaging methods. Hybrid CPlanar/QSPECT provided improved accuracy compared to pure CPlanar and required the addition of only a single SPECT acquisition. The QPlanar or hybrid QPlanar/QSPECT methods had mean errors and standard deviations of errors that approached those of pure QSPECT while providing simplified image acquisition protocols, and thus may be more clinically practical.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dynamic estimation of three-dimensional cerebrovascular deformation from rotational angiography

Purpose: The objective of this study is to investigate the feasibility of detecting and quantifying 3D cerebrovascular wall motion from a single 3D rotational x-ray angiography (3DRA) acquisition within a clinically acceptable time and computing from the estimated motion field for the further biomechanical modeling of the cerebrovascular wall. Methods: The whole motion cycle of the cerebral vasculature is modeled using a 4D B-spline transformation, which is estimated from a 4D to 2D+t image registration framework. The registration is performed by optimizing a single similarity metric between the entire 2D+t measured projection sequence and the corresponding forward projections of the deformed volume at their exact time instants. The joint use of two acceleration strategies, together with their implementation on graphics processing units, is also proposed so as to reach computation times close to clinical requirements. For further characterizing vessel wall properties, an approximation of the wall thickness changes is obtained through a strain calculation. Results: Evaluation on in silico and in vitro pulsating phantom aneurysms demonstrated an accurate estimation of wall motion curves. In general, the error was below 10% of the maximum pulsation, even in the situation when substantial inhomogeneous intensity pattern was present. Experiments on in vivo data provided realistic aneurysm and vessel wall motion estimates, whereas in regions where motion was neither visible nor anatomically possible, no motion was detected. The use of the acceleration strategies enabled completing the estimation process for one entire cycle in 5-10 min without degrading the overall performance. The strain map extracted from our motion estimation provided a realistic deformation measure of the vessel wall. Conclusions: The authors' technique has demonstrated that it can provide accurate and robust 4D estimates of cerebrovascular wall motion within a clinically acceptable time, although it has to be applied to a larger patient population prior to possible wide application to routine endovascular procedures. In particular, for the first time, this feasibility study has shown that in vivo cerebrovascular motion can be obtained intraprocedurally from a 3DRA acquisition. Results have also shown the potential of performing strain analysis using this imaging modality, thus making possible for the future modeling of biomechanical properties of the vascular wall.

60 APPLIED LIFE SCIENCES↗

Model-based PSF and MTF estimation and validation from skeletal clinical CT images

Purpose: A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Methods: Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. Results: The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). Conclusions: The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge about the scanner-specific parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry

Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample size required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen–pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence.

61 RADIATION PROTECTION AND DOSIMETRY↗

Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations

Purpose: To investigate the correlation of size-specific dose estimate (SSDE) with absorbed organ dose, and to develop a simple methodology for estimating patient organ dose in a pediatric population (5–55 kg). Methods: Four physical anthropomorphic phantoms representing a range of pediatric body habitus were scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations to determine absolute organ dose. Phantom absolute organ dose was divided by phantom SSDE to determine correlation between organ dose and SSDE. Organ dose correlation factors (CF{sub SSDE}{sup organ}) were then multiplied by patient-specific SSDE to estimate patient organ dose. The CF{sub SSDE}{sup organ} were used to retrospectively estimate individual organ doses from 352 chest and 241 abdominopelvic pediatric CT examinations, where mean patient weight was 22 kg ± 15 (range 5–55 kg), and mean patient age was 6 yrs ± 5 (range 4 months to 23 yrs). Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm; thus, showing appropriate scalability of the phantoms across the entire pediatric population in this study. IndividualCF{sub SSDE}{sup organ} were determined for a total of 23 organs in the chest and abdominopelvic region across nine weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7–1.4) and abdominopelvic region (average 0.9; range 0.7–1.3) was near unity. For organ/tissue that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1–0.4) for both the chest and abdominopelvic regions, respectively. A means to estimate patient organ dose was demonstrated. Calculated patient organ dose, using patient SSDE and CF{sub SSDE}{sup organ}, was compared to previously published pediatric patient doses that accounted for patient size in their dose calculation, and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusions: For organs fully covered within the scan volume, the average correlation of SSDE and organ absolute dose was found to be better than ±10%. In addition, this study provides a complete list of organ dose correlation factors (CF{sub SSDE}{sup organ}) for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.

60 APPLIED LIFE SCIENCES↗