Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A Coupled Deep Learning Model for Estimating Surface NO 2 Levels from Remote Sensing Data: 15-Year Study Over the Contiguous United States

This study proposes a novel two-step deep learning (DL) model for estimating surface NO 2 concentrations using satellite data over the contiguous United States (CONUS) from 2005 to 2019. The first phase of the model uses partial convolutional neural network (PCNN), an advanced DL model that accurately imputes gaps between surface NO 2 stations and creates 5,478 daily-mean NO 2 grids (PCNN-NO 2 ) of the 2005-2019 period over the study area. We then feed the PCNN-NO 2 , along with other predictor variables, into a deep neural network (DNN) to estimate surface NO 2 levels, achieving exceptional performance with a correlation coefficient of 0.975 to 0.978, a mean absolute bias of 0.99 ppb to 1.38 ppb, and a root mean square error of 1.47 ppb to 1.97 ppb. Spatial cross-validation results also indicate strong spatial performance of PCNN-DNN surface NO 2 estimates. In addition to its accurate estimates, the PCNN-DNN model consistently generates estimated NO 2 grids without any missing values, improving the quality of various applications such as emission reduction strategies and public health studies. Between 2005 and 2019, the 5,478 daily estimated NO 2 grids over the CONUS reveal significant reductions in NO 2 levels in fourteen major urban environments: Washington D.C. (-43%), New York (-45%), Los Angeles (-38%), Chicago (-25%), Boston (-43%), Houston (-34%), Dallas (-40%), Philadelphia (-41%), Phoenix (-38%), Detroit (-20%), Denver (-23%), Atlanta (-0.7%), Cincinnati (-38%), and Pittsburgh (-56%). Furthermore, the study shows that the denser urban regions that in-situ stations are installed in, the higher the difference between in-situ observations and regional-mean NO 2 levels.

54 ENVIRONMENTAL SCIENCES↗

Adaptive stretching of representations across brain regions and deep learning model layers

Prefrontal cortex (PFC) is known to modulate the visual system to favor goal-relevant information by accentuating task-relevant stimulus dimensions. Does the brain broadly re-configures itself to optimize performance by stretching visual representations along task-relevant dimensions? We considered a task that required monkeys to selectively attend on a trial-by-trial basis to one of two dimensions (color or motion direction) to make a decision. Although effects were most prominent in frontal areas, representations stretched along task-relevant dimensions in all sites considered: V4, MT, lateral PFC, frontal eye fields (FEF), lateral intraparietal cortex (LIP), and inferotemporal cortex (IT). Spike timing was crucial to this code. A deep learning model was trained on the same visual input and rewards as the monkeys. Despite lacking an explicit selective attention or other control mechanism, by minimizing error during learning, the model’s representations stretched along task-relevant dimensions, indicating that stretching is an adaptive strategy.

59 BASIC BIOLOGICAL SCIENCES↗

Spectral contaminant identifier for off-axis integrated cavity output spectroscopy measurements of liquid water isotopes

Developments in cavity-enhanced absorption spectrometry have made it possible to measure water isotopes using faster, more cost-effective field-deployable instrumentation. Several groups have attempted to extend this technology to measure water extracted from plants and found that other extracted organics absorb light at frequencies similar to that absorbed by the water isotopomers, leading to {delta}{sup 2}H and {delta}{sup 18}O measurement errors ({Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O). In this note, the off-axis integrated cavity output spectroscopy (ICOS) spectra of stable isotopes in liquid water is analyzed to determine the presence of interfering absorbers that lead to erroneous isotope measurements. The baseline offset of the spectra is used to calculate a broadband spectral metric, m{sub BB}, and the mean subtracted fit residuals in two regions of interest are used to determine a narrowband metric, m{sub NB}. These metrics are used to correct for {Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O. The method was tested on 14 instruments and {Delta}{delta}{sup 18}O was found to scale linearly with contaminant concentration for both narrowband (e.g., methanol) and broadband (e.g., ethanol) absorbers, while {Delta}{delta}{sup 2}H scaled linearly with narrowband and as a polynomial with broadband absorbers. Additionally, the isotope errors scaled logarithmically with m{sub NB}. Using the isotope error versus m{sub NB} and m{sub BB} curves, {Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O resulting from methanol contamination were corrected to a maximum mean absolute error of 0.93 per mille and 0.25 per mille respectively, while {Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O from ethanol contamination were corrected to a maximum mean absolute error of 1.22 per mille and 0.22 per mille . Large variation between instruments indicates that the sensitivities must be calibrated for each individual isotope analyzer. These results suggest that the properly calibrated interference metrics can be used to correct for polluted samples and extend off-axis ICOS measurements of liquid water to include plant waters, soil extracts, wastewater, and alcoholic beverages. The general technique may also be extended to other laser-based analyzers including methane and carbon dioxide isotope sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical gradients of complete active space self-consistent field energies using Cholesky decomposition: Geometry optimization and spin-state energetics of a ruthenium nitrosyl complex

We present a formulation of analytical energy gradients at the complete active space self-consistent field (CASSCF) level of theory employing density fitting (DF) techniques to enable efficient geometry optimizations of large systems. As an example, the ground and lowest triplet state geometries of a ruthenium nitrosyl complex are computed at the DF-CASSCF level of theory and compared with structures obtained from density functional theory (DFT) using the B3LYP, BP86, and M06L functionals. The average deviation of all bond lengths compared to the crystal structure is 0.042 Å at the DF-CASSCF level of theory, which is slightly larger but still comparable with the deviations obtained by the tested DFT functionals, e.g., 0.032 Å with M06L. Specifically, the root-mean-square deviation between the DF-CASSCF and best DFT coordinates, delivered by BP86, is only 0.08 Å for S{sub 0} and 0.11 Å for T{sub 1}, indicating that the geometries are very similar. While keeping the mean energy gradient errors below 0.25%, the DF technique results in a 13-fold speedup compared to the conventional CASSCF geometry optimization algorithm. Additionally, we assess the singlet-triplet energy vertical and adiabatic differences with multiconfigurational second-order perturbation theory (CASPT2) using the DF-CASSCF and DFT optimized geometries. It is found that the vertical CASPT2 energies are relatively similar regardless of the geometry employed whereas the adiabatic singlet-triplet gaps are more sensitive to the chosen triplet geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermophysical models of underground coal gasification and FEM analysis

In this study, mathematical models of the coupled thermohydromechanical process of coal rock mass in an underground coal gasification panel are established. Combined with the calculation example, the influence of heating effects on the observed values and simulated values for pore water pressure, stress, and displacement in the gasification panel are fully discussed and analyzed. Calculation results indicate that 38, 62, and 96 days after the experiment, the average relative errors for the calculated values and measured values for the temperature and water pressure were between 8.51-11.14% and 3-10%, respectively; with the passage of gasification time, the calculated errors for the vertical stress and horizontal stress gradually declined, but the simulated errors for the horizontal and vertical displacements both showed a rising trend. On the basis of the research results, the calculated values and the measured values agree with each other very well.

01 COAL, LIGNITE, AND PEAT↗

Development of control quality factor for HVAC control loop performance assessment I—Methodology (ASHRAE RP-1587)

This article is the second paper from the ASHRAE research project RP-1587, focusing on the methodology of obtaining a control quality factor (CQF). This article presents a development of two CQFs for assessing the heating, ventilation, and air-conditioning (HVAC) control loop performance. Both CQFs are able to detect whether the control loop is able to maintain the setpoint and identify the loop's ability to handle disturbances. In addition, the reversal behaviors are assessed as well. The first CQF (CQF-Harris) is proposed based on the normalized Harris index using the recursive least squares method. This recursive least squares method is selected because of its computational efficiency compared with the maximum likelihood estimation method. The second CQF (CQF-EWMA) is based on the exponentially weighted moving average of the error ratio. The assessment scale of excellent, good, fair, bad, and failed, which indicates the quality of the HVAC control loops, is established as well. The sensitivity analysis for both CQFs is also conducted, and it provides insights on choosing the appropriate parameters to compute such CQFs. Such parameters include the sampling frequency, the length of the moving window, and the variance of the unmeasured disturbance. The field evaluations and tests of the proposed CQFs for simulated control loops and real control loops can be found in the companion paper with the title 'Development of Control Quality Factor for HVAC Control Loop Performance Assessment - III: Field Testing and Results (ASHRAE RP-1587).'

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Removing Atmospheric Fringes from Zwicky Transient Facility i-band Images using Principal Component Analysis

The Zwicky Transient Facility is a time-domain optical survey that has substantially increased our ability to observe and construct massive catalogs of astronomical objects by use of its 47 square degree camera that can observe in multiple filters. However the telescope’s i-band filter suffers from significant atmospheric fringes that reduce photometric precision, especially for faint sources and in multi-epoch co-additions. Here we present a method for constructing models of these atmospheric fringes using Principal Component Analysis that can be used to identify and remove these artifacts from contaminated images. In addition, we present the Uniform Background Indicator as a quantitative measurement of the reduced correlated background noise and photometric error present after removing fringes. We conclude by evaluating the effect of our method on measuring faint sources through the injection and recovery of artificial stars in both single-image epochs and co-additions. Our method for constructing atmospheric fringe models and applying those models to produce cleaned images is available for public download in the open source Python package fringez.

79 ASTRONOMY AND ASTROPHYSICS↗

Finite and infinite matrix product states for Gutzwiller projected mean-field wave functions

Matrix product states (MPS) and “dressed” ground states of quadratic mean fields (e.g., Gutzwiller projected Slater determinants) are both important classes of variational wave functions. This latter class has played important roles in understanding superconductivity and quantum spin liquids. We present a method to obtain both the finite and infinite MPS (iMPS) representation of the ground state of an arbitrary fermionic quadratic mean-field Hamiltonian (which in the simplest case is a Slater determinant and in the most general case is a Pfaffian). We also show how to represent products of such states (e.g., determinants times Pfaffians). From this representation one can project to single occupancy and evaluate the entanglement spectra after Gutzwiller projection. We then obtain the MPS and iMPS representation of Gutzwiller projected mean-field states that arise from the variational slave-fermion approach to the S = 1 bilinear-biquadratic quantum spin chain. To accomplish this, we develop an approach to orthogonalize degenerate iMPS to find all the states in the degenerate ground-state manifold. We find the energies of the MPS and iMPS states match the variational energies closely, indicating the method is accurate and there is minimal loss due to truncation error. We then present an exploration of the entanglement spectra of projected slave-fermion states, exploring their qualitative features and finding good qualitative agreement with the respective exact ground-state spectra found from density matrix renormalization group.

1-dimensional spin chains↗

Observation of B{sup +}{yields}b{sub 1}{sup +}K{sup 0} and search for B-meson decays to b{sub 1}{sup 0}K{sup 0} and b{sub 1}{pi}{sup 0}

We present the results of searches for decays of B mesons to final states with a b{sub 1} meson and a neutral pion or kaon. The data, collected with the BABAR detector at the Stanford Linear Accelerator Center, represent 465x10{sup 6} BB pairs produced in e{sup +}e{sup -} annihilation. The results for the branching fractions are, in units of 10{sup -6}, B(B{sup +}{yields}b{sub 1}{sup +}K{sup 0})=9.6{+-}1.7{+-}0.9, B(B{sup 0}{yields}b{sub 1}{sup 0}K{sup 0})=5.1{+-}1.8{+-}0.5 (<7.8), B(B{sup +}{yields}b{sub 1}{sup +}{pi}{sup 0})=1.8{+-}0.9{+-}0.2 (<3.3), and B(B{sup 0}{yields}b{sub 1}{sup 0}{pi}{sup 0})=0.4{+-}0.8{+-}0.2 (<1.9), with the assumption that B(b{sub 1}{yields}{omega}{pi})=1. We also measure the charge asymmetry A{sub ch}(B{sup +}{yields}b{sub 1}{sup +}K{sup 0})=-0.03{+-}0.15{+-}0.02. The first error quoted is statistical, the second systematic, and the upper limits in parentheses indicate the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PPT-GPU: Scalable GPU Performance Modeling

Performance modeling is a challenging problem due to the complexities of hardware architectures. In this paper, we present PPT-GPU, a scalable and accurate simulation framework that enables GPU code developers and architects to predict the performance of applications in a fast, and accurate manner on different GPU architectures. PPT-GPU is part of the open source project, Performance Prediction Toolkit (PPT) developed at the Los Alamos National Laboratory. We extend the old GPU model in PPT that predict the runtimes of computational physics codes to offer better prediction accuracy, for which, we add models for different memory hierarchies found in GPUs and latencies for different instructions. To further show the utility of PPT-GPU, we compare our model against real GPU device(s) and the widely used cycle-accurate simulator, GPGPU-Sim using different workloads from RODINIA and Parboil benchmarks. The results indicate that the predicted performance of PPT-GPU is within a 10% error compared to the real device(s). In addition, PPT-GPU is highly scalable, where it is up to 450x faster than GPGPU-Sim with more accurate results.

97 MATHEMATICS AND COMPUTING↗

Comparison of Results for Quarter 1 Surface Water Split Samples Collected at the Nuclear Fuel Services Site, Erwin, Tennessee

Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on August 22, 2012. Representatives from the U.S. Nuclear Regulatory Commission and Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses. The comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER ≤ 3 indicates that, at a 99% confidence interval, split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty. The NFS split sample report does not specify the confidence level of reported uncertainties. Therefore, standard two sigma reporting is assumed and uncertainty values were divided by 1.96. A comparison of split sample results, using the DER equation, indicates one set with a DER greater than 3. A DER of 3.1 is calculated for gross alpha results from ORAU sample 5198W0003 and NFS sample MCU-310212003. The ORAU result is 0.98 ± 0.30 pCi/L (value ± 2 sigma) compared to the NFS result of -0.08 ± 0.60 pCi/L. Relatively high DER values are not unexpected for low (e.g., background) analyte concentrations analyzed by separate laboratories, as is the case here. It is noted, however, NFS uncertainties are at least twice the ORAU uncertainties, which contributes to the elevated DER value. Differences in ORAU and NFS minimum detectable activities are even more pronounced. comparison of ORAU and NFS split samples produces reasonably consistent results for low (e.g., background) concentrations.

54 ENVIRONMENTAL SCIENCES↗

COMPARISON OF RESULTS FOR QUARTER 4 SURFACE WATER SPLIT SAMPLES COLLECTED AT THE NUCLEAR FUELS SERVICES SITE, ERWIN, TN

Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on June 12, 2013. Representatives from the U.S. Nuclear Regulatory Commission (NRC) and the Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses, and Table 1 presents the comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER ≤ 3 indicates at a 99% confidence interval that split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty (ANSI N42.22). The NFS split sample report specifies 95% confidence level of reported uncertainties (NFS 2013). Therefore, standard two sigma reporting values were divided by 1.96. In conclusion, most DER values were less than 3 and results are consistent with low (e.g., background) concentrations. The gross beta result for sample 5198W0014 was the exception. The ORAU gross beta result of 6.30 &plusmn 0.65 pCi/L from location NRD is well above NFS's non-detected result of 1.56 &plusmn 0.59 pCi/L. NFS's data package includes no detected result for any radionuclide at location NRD. At NRC's request, ORAU performed gamma spectroscopic analysis of sample 5198W0014 to identify analytes contributing to the relatively elevated gross beta results. This analysis identified detected amounts of naturally-occurring constituents, most notably Ac-228 from the thorium decay series, and does not suggest the presence of site-related contamination.

54 ENVIRONMENTAL SCIENCES↗

COMPARISON OF RESULTS FOR QUARTER 3 SURFACE WATER SPLIT SAMPLES COLLECTED AT THE NUCLEAR FUEL SERVICES SITE, ERWIN, TENNESSEE

Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on March 20, 2013. Representatives from the U.S. Nuclear Regulatory Commission and the Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses, and Table 1 presents the comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER {<=} 3 indicates that at a 99% confidence interval, split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty (ANSI N42.22). The NFS split sample report does not specify the confidence level of reported uncertainties (NFS 2013). Therefore, standard two sigma reporting is assumed and uncertainty values were divided by 1.96. In conclusion, most DER values were less than 3 and results are consistent with low (e.g., background) concentrations. The gross beta result for sample 5198W0012 was the exception. The ORAU result of 9.23 &plusmn 0.73 pCi/L from location MCD is well above NFS's result of -0.567 &plusmn 0.63 pCi/L (non-detected). NFS's data package included a detected result for U-233/234, but no other uranium or plutonium detection, and nothing that would suggest the presence of beta-emitting radionuclides. The ORAU laboratory reanalyzed sample 5198W0012 using the remaining portion of the sample volume and a result of 11.3 &plusmn 1.1 pCi/L was determined. As directed, the laboratory also counted the filtrate using gamma spectrometry analysis and identified only naturally occurring or ubiquitous man-made constituents, including beta emitters that are presumably responsible for the elevated gross beta values.

54 ENVIRONMENTAL SCIENCES↗

COMPARISON OF RESULTS FOR QUARTER 2 SURFACE WATER SPLIT SAMPLES COLLECTED AT THE NUCLEAR FUEL SERVICES SITE, ERWIN, TENNESSEE

Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on November 15, 2012. Representatives from the U.S. Nuclear Regulatory Commission and Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses, and the results are compared using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER {<=} 3 indicates that, at a 99% confidence interval, split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty (ANSI N42.22). The NFS split sample report does not specify the confidence level of reported uncertainties (NFS 2012). Therefore, standard two sigma reporting is assumed and uncertainty values were divided by 1.96. In conclusion, all DER values were less than 3 and results are consistent with low (e.g., background) concentrations.

54 ENVIRONMENTAL SCIENCES↗

Solid Mechanics Code Verification: Contrasting Classical and Manufactured Reference Solutions

Verification results for Sierra/SM using inexact reference solutions have often exhibited unsatisfactory convergence behavior. With an understanding of the convergence behavior for these types of tests, one can avoid falsely attributing pathologies of the test with incorrectness of the code. Simple theoretical results highlight that for an inexact reference solution two conditions must be met to observe asymptotic convergence. These conditions, and the resulting types of convergence behaviors, are further illustrated with graphical examples depicting the exact, inexact reference, and sequence of numerical solutions as vectors (in a function space). A stress concentration problem is adopted to contrast convergence behaviors when using inexact (classical linear elastic) and exact (manufactured) reference solutions. Convergence is not initially attained with the classical solution. Convergence with the manufactured solution indicates the convergence failure with the classical reference did not result from code error and provides insight on how for this problem asymptotic convergence could be attained with the classical reference solution by modifying the computational models.

42 ENGINEERING↗

Validation Analysis of the Shoal Groundwater Flow and Transport Model

Environmental restoration at the Shoal underground nuclear test is following a process prescribed by a Federal Facility Agreement and Consent Order (FFACO) between the U.S. Department of Energy, the U.S. Department of Defense, and the State of Nevada. Characterization of the site included two stages of well drilling and testing in 1996 and 1999, and development and revision of numerical models of groundwater flow and radionuclide transport. Agreement on a contaminant boundary for the site and a corrective action plan was reached in 2006. Later that same year, three wells were installed for the purposes of model validation and site monitoring. The FFACO prescribes a five-year proof-of-concept period for demonstrating that the site groundwater model is capable of producing meaningful results with an acceptable level of uncertainty. The corrective action plan specifies a rigorous seven step validation process. The accepted groundwater model is evaluated using that process in light of the newly acquired data. The conceptual model of ground water flow for the Project Shoal Area considers groundwater flow through the fractured granite aquifer comprising the Sand Springs Range. Water enters the system by the infiltration of precipitation directly on the surface of the mountain range. Groundwater leaves the granite aquifer by flowing into alluvial deposits in the adjacent basins of Fourmile Flat and Fairview Valley. A groundwater divide is interpreted as coinciding with the western portion of the Sand Springs Range, west of the underground nuclear test, preventing flow from the test into Fourmile Flat. A very low conductivity shear zone east of the nuclear test roughly parallels the divide. The presence of these lateral boundaries, coupled with a regional discharge area to the northeast, is interpreted in the model as causing groundwater from the site to flow in a northeastward direction into Fairview Valley. Steady-state flow conditions are assumed given the absence of groundwater withdrawal activities in the area. The conceptual and numerical models were developed based upon regional hydrogeologic investigations conducted in the 1960s, site characterization investigations (including ten wells and various geophysical and geologic studies) at Shoal itself prior to and immediately after the test, and two site characterization campaigns in the 1990s for environmental restoration purposes (including eight wells and a year-long tracer test). The new wells are denoted MV-1, MV-2, and MV-3, and are located to the northnortheast of the nuclear test. The groundwater model was generally lacking data in the north-northeastern area; only HC-1 and the abandoned PM-2 wells existed in this area. The wells provide data on fracture orientation and frequency, water levels, hydraulic conductivity, and water chemistry for comparison with the groundwater model. A total of 12 real-number validation targets were available for the validation analysis, including five values of hydraulic head, three hydraulic conductivity measurements, three hydraulic gradient values, and one angle value for the lateral gradient in radians. In addition, the fracture dip and orientation data provide comparisons to the distributions used in the model and radiochemistry is available for comparison to model output. Goodness-of-fit analysis indicates that some of the model realizations correspond well with the newly acquired conductivity, head, and gradient data, while others do not. Other tests indicated that additional model realizations may be needed to test if the model input distributions need refinement to improve model performance. This approach (generating additional realizations) was not followed because it was realized that there was a temporal component to the data disconnect: the new head measurements are on the high side of the model distributions, but the heads at the original calibration locations themselves have also increased over time. This indicates that the steady-state assumption of the groundwater model is in error. To test the robustness of the model despite the transient nature of the heads, the newly acquired MV hydraulic head values were trended back to their likely values in 1999, the date of the calibration measurements. Additional statistical tests are performed using both the backward-projected MV heads and the observed heads to identify acceptable model realizations. A jackknife approach identified two possible threshold values to consider. For the analysis using the backward-trended heads, either 458 or 818 realizations (out of 1,000) are found acceptable, depending on the threshold chosen. The analysis using the observed heads found either 284 or 709 realizations acceptable. The impact of the refined set of realizations on the contaminant boundary was explored using an assumed starting mass of a single radionuclide and the acceptable realizations from the backward-trended analysis.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of observed and modelled aerosol lifetimes using radioactive tracers of opportunity and an ensemble of 19 global models

Aerosols have important impacts on air quality and climate, but the processes affecting their removal from the atmosphere are not fully understood and are poorly constrained by observations. This makes modelled aerosol lifetimes uncertain. In this study, we make use of an observational constraint on aerosol lifetimes provided by radionuclide measurements and investigate the causes of differences within a set of global models. During the Fukushima Dai-Ichi nuclear power plant accident of March 2011, the radioactive isotopes cesium-137 ( 137 Cs) and xenon-133 ( 133 Xe) were released in large quantities. Cesium attached to particles in the ambient air, approximately according to their available aerosol surface area. 137 Cs size distribution measurements taken close to the power plant suggested that accumulation-mode (AM) sulfate aerosols were the main carriers of cesium. Hence, 137 Cs can be used as a proxy tracer for the AM sulfate aerosol's fate in the atmosphere. In contrast, the noble gas 133 Xe behaves almost like a passive transport tracer. Global surface measurements of the two radioactive isotopes taken over several months after the release allow the derivation of a lifetime of the carrier aerosol. We compare this to the lifetimes simulated by 19 different atmospheric transport models initialized with identical emissions of 137 Cs that were assigned to an aerosol tracer with each model's default properties of AM sulfate, and 133 Xe emissions that were assigned to a passive tracer. We investigate to what extent the modelled sulfate tracer can reproduce the measurements, especially with respect to the observed loss of aerosol mass with time. Modelled 137 Cs and 133 Xe concentrations sampled at the same location and times as station measurements allow a direct comparison between measured and modelled aerosol lifetime. The e-folding lifetime τ e , calculated from station measurement data taken between 2 and 9 weeks after the start of the emissions, is 14.3 days (95 % confidence interval 13.1–15.7 days). The equivalent modelled τ e lifetimes have a large spread, varying between 4.8 and 26.7 days with a model median of 9.4 ± 2.3 days, indicating too fast a removal in most models. Because sufficient measurement data were only available from about 2 weeks after the release, the estimated lifetimes apply to aerosols that have undergone long-range transport, i.e. not for freshly emitted aerosol. However, modelled instantaneous lifetimes show that the initial removal in the first 2 weeks was quicker (lifetimes between 1 and 5 days) due to the emissions occurring at low altitudes and co-location of the fresh plume with strong precipitation. Deviations between measured and modelled aerosol lifetimes are largest for the northernmost stations and at later time periods, suggesting that models do not transport enough of the aerosol towards the Arctic. The models underestimate passive tracer ( 133 Xe) concentrations in the Arctic as well but to a smaller extent than for the aerosol ( 137 Cs) tracer. As a result, this indicates that in addition to too fast an aerosol removal in the models, errors in simulated atmospheric transport towards the Arctic in most models also contribute to the underestimation of the Arctic aerosol concentrations.

54 ENVIRONMENTAL SCIENCES↗

A remote sensing algorithm for vertically resolved cloud condensation nuclei number concentrations from airborne and spaceborne lidar observations

Cloud condensation nuclei (CCN) are mediators of aerosol–cloud interactions (ACIs), contributing to the largest uncertainties in the understandings of global climate change. We present a novel remote-sensing-based algorithm that quantifies the vertically resolved CCN number concentrations (N CCN ) using aerosol optical properties measured by a multiwavelength lidar. The algorithm considers five distinct aerosol subtypes with bimodal size distributions. The inversion used the lookup tables developed in this study, based on the observations from the Aerosol Robotic Network, to efficiently retrieve optimal particle size distributions from lidar measurements. The method derives dry aerosol optical properties by implementing hygroscopic enhancement factors in lidar measurements. The retrieved optically equivalent particle size distributions and aerosol-type-dependent particle composition are utilized to calculate critical diameters using κ-Köhler theory and N CCN at six supersaturations ranging from 0.07 % to 1.0 %. Sensitivity analyses indicate that uncertainties in extinction coefficients and relative humidity greatly influence the retrieval error in N CCN . The potential of this algorithm is further evaluated by retrieving N CCN using airborne lidar from the NASA ObseRvations of Aerosols above CLouds and their intEractionS (ORACLES) campaign and is validated against simultaneous measurements from the CCN counter. The independent validation with robust correlation demonstrates promising results. Furthermore, the N CCN has been retrieved for the first time using a proposed algorithm from spaceborne lidar – Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) – measurements. The application of this new capability demonstrates the potential for constructing a 3D CCN climatology at a global scale, which helps to better quantify ACI effects and thus reduce the uncertainty in aerosol climate forcing.

54 ENVIRONMENTAL SCIENCES↗