Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Quantum computation of phase transition in the massive Schwinger model

Abstract As pointed out by Coleman, physical quantities in the Schwinger model depend on a parameter θ that determines the background electric field. There is a phase transition for θ = π only. We develop a momentum space formalism on a lattice and use it to perform a quantum computation of the critical point of this phase transition on the NISQ device IMB Q Lima. After error mitigation, our results give strong indication of the existence of a critical point at m / e ≃ 0.32, where m is the bare fermion mass and e is the coupling strength, in good agreement with the classical numerical result m / e ≃ 0.3335.

Physics↗

Active Learning Surrogates for Integrating Electron Microscopy and Computational Insights from Simulations in Autonomous Experiments

Artificial Intelligence (AI) combined with simulations and experiments has great potential to accelerate scientific discovery across technology and pharmaceuticals. However, the gap between simulations and experiments is challenging due to disparities in time and scale, making it difficult to estimate properties like energy and electronic states from experiments, and to provide feedback based on theoretical insights.Our research addresses the challenge by developing unique deep kernel based surrogate models that learns from microscopic images, mapping structural features to energy differences from defect formation. We start with full-training using simulated images to determine optimal settings, establishing a baseline for active learning. Using these settings from the baseline, active learning is trained, and predicts structures along simulation trajectories based on uncertainty and energetic stability, thus reducing data requirements, simulation time and computational costs. The results demonstrate that the model achieves a low average error margin of approximately 0.03 meV, indicating good performance. To enhance feature extraction and reconstruction capabilities, we developed an autoencoder-decoder as additional surrogate to create latent space to capture essential features, enabling precise comparisons between simulations and experiments. The results from this model achieved a reconstruction loss of around 0.2 and accurately reconstructed molecular structures.Overall, this work advances the steering of experiments through computational simulations by employing a surrogate models that actively predicts the trajectories of structural evolution, achieving time-to-solution comparable to experimental measurements.

Saranathan, Gayathri [Hewlett-Packard]↗

Hybrid Improved Empirical Mode Decomposition and Artificial Neural Network Model for the Prediction of Critical Heat Flux (CHF)

Three Hybrid artificial neural network (ANN) models namely radial basis function (RBF), generalized regression neural networks (GRNN), and multi-layer perceptron (MLP) combined with empirical mode decomposition (EMD) are developed for CHF predictive modelling using CHF experimental databases.First, the original experimental inputs data series are decomposed into several intrinsic mode functions (IMFs) and one residual by EMD, whose components are divided into high, medium and low components. The performance parameters of the hybrid models indicates that the root mean square error (RMSE) are 0.8831, 0.6522, and 0.4149; the mean absolute error (MAE) are 0.6697, 0.4636, and 0.1935. The values of the R-square of the developed prediction approach utilizing EMD-RBF, EMD-GRNN, and EMD-MLP models are 0.8553, 0.9302, and 0.9818, and the index of agreement are 0.9464, 0.9700, and 0.9894., The value of the R-square and the index of agreement of the proposed models are much higher than those of the simple models .The Pearson's test results show that the association strength between the measured and the predicted values of the proposed model EMD-MLP is the strongest. These results show the following: (a) compared with other related, recent studies, the prediction accuracy of the hybrid model EMD- MLP proposed in this research is the best hybrid model; (b) the proposed hybrid model (EMD-MLP) attains superior performance compared with simple models.

Djeddou, Messaoud↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ALMA Band-to-band Phase Referencing: Imaging Capabilities on Long Baselines and High Frequencies

High-frequency long-baseline experiments with the Atacama Large Millimeter/submillimeter Array were organized to test the high angular resolution imaging capabilities in the submillimeter wave regime using baselines up to 16 km. Four experiments were conducted, two Band 7 (289 GHz) and two Band 8 (405 GHz) observations. Phase correction using band-to-band (B2B) phase referencing was used with a phase calibrator only [[Formula]] away observed in Band 3 (96 GHz) and Band 4 (135 GHz), respectively. In Band 8, we achieved the highest resolution of 14 × 11 mas. We compared the synthesis images of the target quasar using 20 and 60 s switching cycle times in the phase referencing. In Band 7, the atmosphere had good stability in phase rms (<0.5 rad over 2 minutes), and there was little difference in image coherence between the 20 and 60 s switching cycle times. One Band 8 experiment was conducted under a worse phase rms condition (>1 rad over 2 minutes), which led to a significantly reduced coherence when using the 60 s switching cycle time. One of our four experiments indicates that the residual phase rms error after phase referencing can be reduced to 0.16 rad at 289 GHz in using the 20 s switching cycle time. Such conditions would meet the phase correction requirement of image coherence of >70% in Band 10, assuming a similar phase calibrator separation angle, emphasizing the need for such B2B phase referencing observing at high frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Input-output, expandable-parity network

Large-scale integrated circuit generates and checks parity of four eight-bit registers. In addition, circuit will indicate by output signal whether parity error exists. Circuit can also generate or check parity of words up to 32 bits. This is done by making appropriate internal wiring connections on the large-scale integrated chip.

Mckevitt, J. F., III↗

Jupiter's atmosphere - Problems and potential of radio occultation

The atmospheric temperature-pressure profiles derived from the Pioneer 10-Pioneer 11 radio occultation experiment are mutually consistent but differ markedly from the results of other investigations. Current studies indicate that the occultation interpretation contains errors that were made very large by an inherent magnification effect, and that these errors have both geometrical and equipment sources. The apparent consistency between the Pioneer 10 and Pioneer 11 results must be considered fortuitous. Despite these difficulties, the occultation technique, when optimally instrumented and carefully interpreted, retains its potential for atmospheric profile measurements of high accuracy and resolution.

Eshleman, V. R.↗

Quantitative analysis of aircraft multispectral-scanner data and mapping of water-quality parameters in the James River in Virginia

Statistical analysis techniques were applied to develop quantitative relationships between in situ river measurements and the remotely sensed data that were obtained over the James River in Virginia on 28 May 1974. The remotely sensed data were collected with a multispectral scanner and with photographs taken from an aircraft platform. Concentration differences among water quality parameters such as suspended sediment, chlorophyll a, and nutrients indicated significant spectral variations. Calibrated equations from the multiple regression analysis were used to develop maps that indicated the quantitative distributions of water quality parameters and the dispersion characteristics of a pollutant plume entering the turbid river system. Results from further analyses that use only three preselected multispectral scanner bands of data indicated that regression coefficients and standard errors of estimate were not appreciably degraded compared with results from the 10-band analysis.

Johnson, R. W.↗

Evaluation of an infrared horizon scanner bias determination algorithm for earth-oriented spacecraft

An algorithm for estimating infrared horizon scanner biases for earth-oriented spacecraft is presented. A mathematical description of the proposed algorithm is given, and the algorithm is evaluated for use by two earth-oriented spacecraft: the Applications Explorer Missions-A/Heat Capacity Mapping Mission (AEM-A/HCMM) and Seasat-A. The results of this study indicate that scanner alignment and calibration errors appear as nearly constant biases in the scanner pitch and roll data and that these constant biases can be estimated to within 0.05 degree for AEM-A and 0.03 degree for Seasat-A.

Hotovy, S. G.↗

Rotational excitation of hydrogen molecules by collisions with hydrogen atoms

Rate constants for rotational excitation of hydrogen molecules by collisions with hydrogen atoms have been obtained from quantum-mechanical calculations for kinetic temperatures between 100 and 5000 K. These calculations involve the rigid-rotator approximation, but other possible sources of error should be small. The calculations indicate that the early values of Nishimura are larger than accurate rigid-rotator values by about a factor of 20 or more.

Green, S.↗

Decoupled longitudinal controls for shear penetration in the terminal area environment

The use of decoupled longitudinal controls is simulated for the approach and landing of a twin engine jet transport in the presence of wind shear. Decoupled or independent control of pitch angle, flight-path angle and forward velocity using constant prefilter and feedback gains was compared to conventional control of a B-737 aircraft simulator. It is found that the mean flight-path angle, the mean glideslope error and the mean deviation in indicated airspeed generally improved when decoupled controls were used in the approach. An improvement in touchdown parameters was also observed, especially in strong shear, when 44% of conventionally-controlled flights impacted short of the runway. Simulator pilots reported improved approach performance and a reduced workload when decoupled controls were used.

Miller, G. K., Jr.↗

Modified MEE Industries static thermal gradient diffusion cloud chamber

The experiments performed at the Workshop were undertaken to confirm the calculated sample volume, determine the usable range of supersaturation, and minimum detectable size. Comparison of absolute CCN concentrations with other state-of-the-art continuous flow diffusion chambers at supersaturations near 1 percent indicated that the volume used produced CCN concentrations well within the range of CCN concentrations determined at the workshop. This agreement is interpreted to mean the sample volume was correct. Direct measurements of the beam geometry done in the laboratory indicated a factor of 4-5 error. This error is apparently due to the larger apparent visible beam diameter versus the actual usable beam diameter given the droplet illumination, chamber optical geometry, microscope optics and film characteristics.

Borys, R. D.↗

SAR calibration technology review

Synthetic Aperture Radar (SAR) calibration technology including a general description of the primary calibration techniques and some of the factors which affect the performance of calibrated SAR systems are reviewed. The use of reference reflectors for measurement of the total system transfer function along with an on-board calibration signal generator for monitoring the temporal variations of the receiver to processor output is a practical approach for SAR calibration. However, preliminary error analysis and previous experimental measurements indicate that reflectivity measurement accuracies of better than 3 dB will be difficult to achieve. This is not adequate for many applications and, therefore, improved end-to-end SAR calibration techniques are required.

Walker, J. L.↗

Low-level water vapor fields from the VISSR atmospheric sounder (VAS) split window channels at 11 and 12 microns

A series of high-resolution water vapor fields were derived from the 11 and 12 micron channels of the VISSR Atmospheric Sounder (VAS) on GOES-5. The low-level tropospheric moisture content was separated from the surface and atmospheric radiances by using the differential adsorption across the 'split window' along with the average air temperature from imbedded radiosondes. Fields of precipitable water are presented in a time sequence of five false color images taken over the United States at 3-hour intervals. Vivid subsynoptic and mesoscale patterns evolve at 15 km horizontal resolution over the 12-hour observing period. Convective cloud formations develop from several areas of enhanced low-level water vapor, especially where the vertical water vapor gradient relatively strong. Independent verification at radiosonde sites indicates fairly good absolute accuracy, and the spatial and temporal continuity of the water vapor features indicates very good relative accuracy. Residual errors are dominated by radiometer noise and unresolved clouds.

Chesters, D.↗

Evaluation of the CEAS model for barley yields in North Dakota and Minnesota

The CEAS yield model is based upon multiple regression analysis at the CRD and state levels. For the historical time series, yield is regressed on a set of variables derived from monthly mean temperature and monthly precipitation. Technological trend is represented by piecewise linear and/or quadriatic functions of year. Indicators of yield reliability obtained from a ten-year bootstrap test (1970-79) demonstrated that biases are small and performance as indicated by the root mean square errors are acceptable for intended application, however, model response for individual years particularly unusual years, is not very reliable and shows some large errors. The model is objective, adequate, timely, simple and not costly. It considers scientific knowledge on a broad scale but not in detail, and does not provide a good current measure of modeled yield reliability.

Barnett, T. L.↗

A Covariance Analysis for the Determination of Baseline Observing GPS Satellites

Results of covariance analyses are presented for the determination of baseline vectors of length from 150 m to 4000 km. The data are doubly differenced ranges derived from the signals transmitted by the satellites of the Global Positioning System. The modeling of various error sources is described. The results indicate the low cost baseline determination system is capable of subdecimeter accuracy for baselines up to 1000 km in length.

Wu, S. C.↗

The use of LANDSAT-4 MSS digital data in temporal data sets and the evaluation of scene-to-scene registration accuracy

The MSS sensor on LANDSAT 4 is, in certain performance aspects, different from those on LANDSATS 1 through 3. These differences created some concern in the NASA research community as to whether individual data sets can be registered accurately enough to produce acceptable data sets for multitemporal data analysis. The use of LANDSAT 4 MSS digital data in temporal data sets is examined and a method is presented for estimating temporal registration accuracy based on the use of an X-Y digitizer and grey tone electrostatic plots. Results indicate that the RMS temporal registration errors are not significantly different from the temporal data sets generated using LANDSAT 4 and LANDSAT 2 data (33.35 meters) and the temporal data set constructed from two LANDSAT 2 data sets (33.61 meters). A derivation of the model used to evaluate the temporal registration is included.

Anderson, J. E.↗