Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “entry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Chemical changes in thirdhand smoke associated with remediation using an ozone generator

Ozonation is a common remediation approach to eliminate odors from mold, tobacco and fire damage in buildings. Little information exists to: 1) assess its effectiveness; 2) provide guidance on operation conditions; and 3) identify potential risks associated with the presence of indoor ozone and ozonation byproducts. The goal of this study is to evaluate chemical changes in thirdhand smoke (THS) aerosols induced by high levels of ozone, in comparison with THS aerosols aged under similar conditions in the absence of ozone. Samples representing different stages of smoke aging in the absence of ozone, including freshly emitted secondhand smoke (SHS) and THS, were collected inside an 18-m 3 room-sized chamber over a period of 42 h after six cigarettes were consumed. The experiments involved collection and analysis of gas phase species including volatile organic compounds (VOCs), volatile carbonyls, semivolatile organic compounds (SVOCs), and particulate matter. VOC analysis was carried out by gas chromatography/mass spectrometry with a thermal desorption inlet (TD-GC/MS), and volatile carbonyls were analyzed by on-line derivatization with dinitrophenylhydrazine (DNPH), followed by liquid chromatography with UV/VIS detection. SVOCs were extracted from XAD-coated denuders and Teflon-coated fiberglass filters in the absence of ozone. In those extracts, tobacco-specific nitrosamines (TSNAs) and other SVOCs were analyzed by gas chromatography with positive chemical ionization-triple quadrupole mass spectrometric detection (GC/PCI-QQQ-MS), and polycyclic aromatic hydrocarbons (PAHs) were quantified by gas chromatography with ion trap mass spectrometric detection (GC/IT-MS) in selected ion monitoring mode. Particulate matter concentration was determined gravimetrically. In a second experiment, a 300 mg h -1 commercial ozone generator was operated during 1 h, one day after smoke was generated, to evaluate the remediation of THS by ozonation. VOCs and volatile carbonyls were analyzed before and after ozonation. Extracts from fabrics that were exposed in the chamber before and after ozonation as surrogates for indoor furnishings were analyzed by GC/IT-MS, and aerosol size distribution was studied with a scanning mobility particle sizer. Ozone concentration was measured with a photometric detector. An estimated 175 mg ozone reacted with THS after 1 h of treatment, corresponding to 58% of the total O 3 released during that period. Fabric-bound nicotine was depleted after ozonation, and the surface concentration of PAHs adsorbed to fabric specimens decreased by an order of magnitude due to reaction with ozone, reaching pre-smoking levels. These results suggest that ozonation has the potential to remove harmful THS chemicals from indoor surfaces. However, gas phase concentrations of volatile carbonyls, including formaldehyde, acetaldehyde and acetone were higher immediately after ozonation. Ultrafine particles (UFP, in most cases with size <60 nm) were a major ozonation byproduct. UFP number concentrations peaked shortly after ozonation ended, and remained at higher-than background levels for several hours. Based on these results, minimum re-entry times after ozone treatment were predicted for different indoor scenarios. Clearly defining re-entry times can serve as a practical measure to prevent acute exposures to ozone and harmful ozonation byproducts after treatment. This study evaluated potential benefits and risks associated with THS remediation using ozone, providing insights into this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Oblique inlet pressure loss for swirling flow entering a catalyst substrate

This experimental study investigates the oblique inlet pressure loss for the entry of an annular swirling flow into an automotive catalyst substrate. The results are applicable to a wide range of compact heat exchangers. For zero swirl, the total pressure loss agrees with established expressions for pressure loss in developing laminar flow in parallel channels with finite wall thickness. For positive swirl, the additional pressure loss due to oblique flow entry is correlated to the tangential velocity upstream of the catalyst, measured using laser-Doppler anemometry. The obtained oblique inlet pressure loss correlation can improve the accuracy of numerical calculations of the flow distribution in catalysts. (author)

33 ADVANCED PROPULSION SYSTEMS↗

The effect of different inlet conditions of air in a rectangular channel on convection heat transfer: Turbulence flow

Theoretical and empirical correlations for duct flow are given for hydrodynamically and thermally developed flow in most of previous studies. However, this is commonly not a realistic inlet configuration for heat exchanger, in which coolant flow generally turns through a serpentine shaped passage before entering heat sinks. Accordingly, an experimental investigation was carried out to determine average heat transfer coefficients in uniformly heated rectangular channel with 45 and 90 turned flow, and with wall mounted a baffle. The channel was heated through bottom side with the baffle. In present work, a detailed study was conducted for three different height of entry channel (named as the ratio of the height of entry channel to the height of test section (anti H{sub c}=h{sub c}/H)) by varying Reynolds number (Re{sub Dh}). Another variable parameter was the ratio of the baffle height to the channel height (anti H{sub b}=h{sub b}/H). Only one baffle was attached on the bottom (heating) surface. The experimental procedure was validated by comparing the data for the straight channel with no baffle. Reynolds number (Re{sub Dh}) was varied from 2800 to 30,000, so the flow was considered as only turbulent regime. All experiments were conduced with air accordingly; Prandtl number (Pr) was approximately fixed at 0.71. The results showed that average Nusselt number for {theta}=45 and {theta}=90 were 9% and 30% higher, respectively, than that of the straight channel without baffle. Likewise, the pressure drop increased up to 4.4 to 5.3 times compare to the straight channel. (author)

42 ENGINEERING↗

On the provenance of GEMS, a quarter century post discovery

The provenance of GEMS (glass with embedded metal and sulfides) in cometary type interplanetary dust particles is investigated using analytical scanning transmission electron microscopy and secondary ion mass spectrometry. We review the current state of knowledge and closely examine the densities, elemental compositions and distributions, iron oxidation states, and isotopic compositions of a subset of GEMS in chondritic porous interplanetary dust. We find that GEMS are underdense with estimated densities that are 35–65% of compositionally equivalent crystalline aggregates. GEMS low densities result in a lower contribution to the bulk compositions of IDPs than has been assumed based on their volume fraction. We also find that element/Si ratios, assumed to be primary (indigenous), are instead perturbed by contamination and secondary alteration, including pulse heating during atmospheric entry. Fe in pyrrhotite inclusions was oxidized and Mg, S, Ca, and Fe were depleted relative to lithophile Al and Si, resulting in reduction in element/Si ratios. Because they trap outgassing elements, Fe-rich oxide rims that formed on the surface of GEMS are serendipitous “witness plates” to the changes in composition that accompany atmospheric entry. As a result of alteration, GEMS elemental compositions cannot reliably inform about their provenance. Except for highly anomalous oxygen isotope ratios measured in some large GEMS grains that indicate a contribution from circumstellar dust, oxygen isotope compositions are generally poor indicators of provenance. Prior work indicates that most GEMS fall close to the terrestrial oxygen isotope composition, which, however, does not exclude a presolar interstellar origin. Nitrogen isotopic compositions are more diagnostic. Elevated 15 N/ 14 N ratios indicate that GEMS accreted in conjunction with formation of organic matter by ion–molecule reactions in a cold (<50 K) presolar environment like the extreme outer nebula or interstellar medium. Considering all observations, we conclude that GEMS are most likely processed interstellar silicates.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility of Economic Analysis of Radiation Therapy Oncology Group (RTOG) 91-11 Using Medicare Data

Purpose: The specific aim of this analysis was to evaluate the feasibility of performing a cost-effectiveness analysis using Medicare data from patients treated on a randomized Phase III clinical trial. Methods and Materials: Cost data included Medicare Part A and Part B costs from all providers-inpatient, outpatient, skilled nursing facility, home health, hospice, and physicians-and were obtained from the Centers for Medicare and Medicaid Services for patients eligible for Medicare, treated on Radiation Therapy Oncology Group (RTOG) 9111 between 1992 and 1996. The 47-month expected discounted (annual discount rate of 3%) cost for each arm of the trial was calculated in 1996 dollars, with Kaplan-Meier sampling average estimates of survival probabilities for each month and mean monthly costs. Overall and disease-free survival was also discounted 3%/year. The analysis was performed from a payer's perspective. Incremental cost-effectiveness ratios were calculated comparing the chemotherapy arms to the radiation alone arm. Results: Of the 547 patients entered, Medicare cost data and clinical outcomes were available for 66 patients. Reasons for exclusion included no RTOG follow-up, Medicare HMO enrollment, no Medicare claims since trial entry, and trial entry after 1996. Differences existed between groups in tumor characteristics, toxicity, and survival, all which could affect resource utilization. Conclusions: Although we were able to test the methodology of economic analysis alongside a clinical trial using Medicare data, the results may be difficult to translate to the entire trial population because of non-random missing data. Methods to improve Medicare data capture and matching to clinical trial samples are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Failure Mode and Effects Analysis to Intraoperative Radiation Therapy Using Mobile Electron Linear Accelerators

Purpose: Failure mode and effects analysis (FMEA) represents a prospective approach for risk assessment. A multidisciplinary working group of the Italian Association for Medical Physics applied FMEA to electron beam intraoperative radiation therapy (IORT) delivered using mobile linear accelerators, aiming at preventing accidental exposures to the patient. Methods and Materials: FMEA was applied to the IORT process, for the stages of the treatment delivery and verification, and consisted of three steps: 1) identification of the involved subprocesses; 2) identification and ranking of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system, based on the product of three parameters (severity, frequency of occurrence and detectability, each ranging from 1 to 10); 3) identification of additional safety measures to be proposed for process quality and safety improvement. RPN upper threshold for little concern of risk was set at 125. Results: Twenty-four subprocesses were identified. Ten potential failure modes were found and scored, in terms of RPN, in the range of 42-216. The most critical failure modes consisted of internal shield misalignment, wrong Monitor Unit calculation and incorrect data entry at treatment console. Potential causes of failure included shield displacement, human errors, such as underestimation of CTV extension, mainly because of lack of adequate training and time pressures, failure in the communication between operators, and machine malfunctioning. The main effects of failure were represented by CTV underdose, wrong dose distribution and/or delivery, unintended normal tissue irradiation. As additional safety measures, the utilization of a dedicated staff for IORT, double-checking of MU calculation and data entry and finally implementation of in vivo dosimetry were suggested. Conclusions: FMEA appeared as a useful tool for prospective evaluation of patient safety in radiotherapy. The application of this method to IORT lead to identify three safety measures for risk mitigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Live-Cell Imaging Visualizes Frequent Mitotic Skipping During Senescence-Like Growth Arrest in Mammary Carcinoma Cells Exposed to Ionizing Radiation

Purpose: Senescence-like growth arrest in human solid carcinomas is now recognized as the major outcome of radiotherapy. This study was designed to analyze cell cycle during the process of senescence-like growth arrest in mammary carcinoma cells exposed to X-rays. Methods and Materials: Fluorescent ubiquitination-based cell cycle indicators were introduced into the human mammary carcinoma cell line MCF-7. Cell cycle was sequentially monitored by live-cell imaging for up to 5 days after exposure to 10 Gy of X-rays. Results: Live-cell imaging revealed that cell cycle transition from G2 to G1 phase without mitosis, so-called mitotic skipping, was observed in 17.1% and 69.8% of G1- and G2-irradiated cells, respectively. Entry to G1 phase was confirmed by the nuclear accumulation of mKO{sub 2}-hCdt1 as well as cyclin E, which was inversely correlated to the accumulation of G2-specific markers such as mAG-hGeminin and CENP-F. More than 90% of cells skipping mitosis were persistently arrested in G1 phase and showed positive staining for the senescent biochemical marker, which is senescence-associated ss-galactosidase, indicating induction of senescence-like growth arrest accompanied by mitotic skipping. While G2 irradiation with higher doses of X-rays induced mitotic skipping in approximately 80% of cells, transduction of short hairpin RNA (shRNA) for p53 significantly suppressed mitotic skipping, suggesting that ionizing radiation-induced mitotic skipping is associated with p53 function. Conclusions: The present study found the pathway of senescence-like growth arrest in G1 phase without mitotic entry following G2-irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Targeted Radiosensitization by the Chk1 Inhibitor SAR-020106

Purpose: To explore the activity of a potent Chk1 inhibitor (SAR-020106) in combination with radiation. Methods and Materials: Colony and mechanistic in vitro assays and a xenograft in vivo model. Results: SAR-020106 suppressed-radiation-induced G{sub 2}/M arrest and reduced clonogenic survival only in p53-deficient tumor cells. SAR-020106 promoted mitotic entry following irradiation in all cell lines, but p53-deficient cells were likely to undergo apoptosis or become aneuploid, while p53 wild-type cells underwent a postmitotic G{sub 1} arrest followed by subsequent normal cell cycle re-entry. Following combined treatment with SAR-020106 and radiation, homologous-recombination-mediated DNA damage repair was inhibited in all cell lines. A significant increase in the number of pan-γH2AX-staining apoptotic cells was observed only in p53-deficient cell lines. Efficacy was confirmed in vivo in a clinically relevant human head-and-neck cell carcinoma xenograft model. Conclusion: The Chk1 inhibitor SAR-020106 is a potent radiosensitizer in tumor cell lines defective in p53 signaling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RTOG 0417: Efficacy of Bevacizumab in Combination With Definitive Radiation Therapy and Cisplatin Chemotherapy in Untreated Patients With Locally Advanced Cervical Carcinoma

Purpose: Radiation Therapy Oncology Group 0417 was a phase II study that explored the safety and efficacy of the addition of bevacizumab to chemoradiation therapy. The safety results have been previously reported. Herein we report the secondary efficacy endpoints of overall survival (OS), locoregional failure (LRF), para-aortic nodal failure (PAF), distant failure (DF), and disease-free survival (DFS). Methods and Materials: Eligible patients with bulky Stage IB-IIIB disease were treated with once-weekly cisplatin (40 mg/m{sup 2}) chemotherapy and standard pelvic radiation therapy and brachytherapy. Bevacizumab was administered at 10 mg/kg intravenously every 2 weeks for 3 cycles during chemoradiation. For OS, failure was defined as death of any cause and was measured from study entry to date of death. LRF was defined as any failure in the pelvis. PAF was defined as any para-aortic nodal failure. DF was analyzed both including and excluding PAF. DFS was measured from study entry to date of first LRF. DF was measured with or without PAF or death. OS and DFS were estimated by the Kaplan-Meier method, and LRF and DF rates were estimated by the cumulative incidence method. Results: 49 eligible patients from 28 institutions were enrolled between 2006 and 2009. The median follow-up time was 3.8 years (range, 0.8-6.0 years). The surviving patients had a median follow-up time of 3.9 years (range, 2.1-6.0 years). Most patients had tumors of International Federation of Gynecology and Obstetrics Stage IIB (63%), and 80% were squamous. The 3-year OS, DFS, and LRF were 81.3% (95% confidence interval [CI], 67.2%-89.8%), 68.7% (95% CI, 53.5%-79.8%), and 23.2% (95% CI, 11%-35.4%), respectively. The PAF, DF without PAF, and DF with PAF at 3 years were 8.4% (95% CI, 0.4%-16.3%), 14.7% (95% CI, 4.5%-24.9%), and 23.1% (95% CI 11.0%-35.2%), respectively. Conclusion: In this study, bevacizumab in combination with standard pelvic chemoradiation therapy for locally advanced cervical cancer showed efficacy results that are promising and may warrant further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Technique for Hepatic Fiducial Marker Placement for Stereotactic Body Radiation Therapy

Purpose: To report experience with fiducial marker insertion and describe an advantageous, novel technique for fiducial placement in the liver for stereotactic body radiation therapy with respiratory tracking. Methods and Materials: We implanted 1444 fiducials (single: 834; linked: 610) in 328 patients with 424 hepatic lesions. Two methods of implantation were compared: the standard method (631 single fiducials) performed on 153 patients from May 2007 to May 2010, and the cube method (813 fiducials: 610 linked/203 single) applied to 175 patients from April 2010 to March 2013. The standard method involved implanting a single marker at a time. The novel technique entailed implanting 2 pairs of linked markers when possible in a way to occupy the perpendicular edges of a cube containing the tumor inside. Results: Mean duration of the cube method was shorter than the standard method (46 vs 61 minutes; P<.0001). Median numbers of skin and subcapsular entries were significantly smaller with the cube method (2 vs 4, P<.0001, and 2 vs 4, P<.0001, respectively). The rate of overall complications (total, major, and minor) was significantly lower in the cube method group compared with the standard method group (5.7% vs 13.7%; P=.013). Major complications occurred while using single markers only. The success rate was 98.9% for the cube method and 99.3% for the standard method. Conclusions: We propose a new technique of hepatic fiducial implantation that makes use of linked fiducials and involves fewer skin entries and shorter time of implantation. The technique is less complication-prone and is migration-resistant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A fast algorithm for sparse matrix computations related to inversion

We have developed a fast algorithm for computing certain entries of the inverse of a sparse matrix. Such computations are critical to many applications, such as the calculation of non-equilibrium Green’s functions G{sup r} and G{sup <} for nano-devices. The FIND (Fast Inverse using Nested Dissection) algorithm is optimal in the big-O sense. However, in practice, FIND suffers from two problems due to the width-2 separators used by its partitioning scheme. One problem is the presence of a large constant factor in the computational cost of FIND. The other problem is that the partitioning scheme used by FIND is incompatible with most existing partitioning methods and libraries for nested dissection, which all use width-1 separators. Our new algorithm resolves these problems by thoroughly decomposing the computation process such that width-1 separators can be used, resulting in a significant speedup over FIND for realistic devices — up to twelve-fold in simulation. The new algorithm also has the added advantage that desired off-diagonal entries can be computed for free. Consequently, our algorithm is faster than the current state-of-the-art recursive methods for meshes of any size. Furthermore, the framework used in the analysis of our algorithm is the first attempt to explicitly apply the widely-used relationship between mesh nodes and matrix computations to the problem of multiple eliminations with reuse of intermediate results. This framework makes our algorithm easier to generalize, and also easier to compare against other methods related to elimination trees. Finally, our accuracy analysis shows that the algorithms that require back-substitution are subject to significant extra round-off errors, which become extremely large even for some well-conditioned matrices or matrices with only moderately large condition numbers. When compared to these back-substitution algorithms, our algorithm is generally a few orders of magnitude more accurate, and our produced round-off errors stay at a reasonable level.

97 MATHEMATICS AND COMPUTING↗

International challenge to predict the impact of radioxenon releases from medical isotope production on a comprehensive nuclear test ban treaty sampling station

Abstract The International Monitoring System (IMS) is part of the verification regime for the Comprehensive Nuclear-Test-Ban-Treaty Organization (CTBTO). At entry-into-force, half of the 80 radionuclide stations will be able to measure concentrations of several radioactive xenon isotopes produced in nuclear explosions, and then the full network may be populated with xenon monitoring afterward (Bowyer et al., 2013). Fission-based production of 99Mo for medical purposes also releases radioxenon isotopes to the atmosphere (Saey, 2009). One of the ways to mitigate the effect of emissions from medical isotope production is the use of stack monitoring data, if it were available, so that the effect of radioactive xenon emissions could be subtracted from the effect from a presumed nuclear explosion, when detected at an IMS station location. To date, no studies have addressed the impacts the time resolution or data accuracy of stack monitoring data have on predicted concentrations at an IMS station location. Recently, participants from seven nations used atmospheric transport modeling to predict the time-history of 133Xe concentration measurements at an IMS station in Germany using stack monitoring data from a medical isotope production facility in Belgium. Participants received only stack monitoring data and used the atmospheric transport model and meteorological data of their choice. Some of the models predicted the highest measured concentrations quite well (a high composite statistical model comparison rank or a small mean square error with the measured values). The results suggest release data on a 15 min time spacing is best. The model comparison rank and ensemble analysis suggests that combining multiple models may provide more accurate predicted concentrations than any single model. Further research is needed to identify optimal methods for selecting ensemble members and those methods may depend on the specific transport problem. None of the submissions based only on the stack monitoring data predicted the small measured concentrations very well. The one submission that best predicted small concentrations also included releases from nuclear power plants. Modeling of sources by other nuclear facilities with smaller releases than medical isotope production facilities may be important in discriminating those releases from releases from a nuclear explosion.

133Xe↗

Enabling BWR fuel rod analysis in the BISON fuel performance code

Nuclear fuel vendors around the world are pursuing approaches to sustain the existing nuclear reactor fleet consisting primarily of pressurized-water reactors (PWRs) and boiling-water reactors (BWRs). To support the industry's efforts, advanced modeling and simulation tools need to be capable of analyzing both legacy reactor concepts. BWR fuel rods are significantly different than those used in PWRs, which can affect fuel performance analysis. BWR fuel rods include: (1) an extensive use of gadolinia dopant as a burnable absorber, (2) an axial variation in fuel enrichment and gadolinia content, (3) the inclusion of a liner on the inner cladding surface to mitigate the impact of pellet-clad mechanical interaction (which impacts hydrogen and hydride distribution), (4) a lower initial fill gas pressure, (5) bottom-entry control rods, and (6) a lower coolant pressure that results in the two-phase flow boiling phenomenon. Although the primary focus of BISON has been in the area of PWR and advanced reactor fuel analyses, this paper presents the developments in BISON to support BWR fuel performance analysis. An overview of the models that account for the effects of gadolinia is highlighted. Internal mesh generation capabilities to include a liner is presented. Normal operating and transient (reactivity insertion accident) demonstration problems are presented to illustrate the impact of gadolinia, the hydrogen and hydride evolution due to the presence of the liner, and BISON's ability to simulate axially varying enrichments and dopant concentration. Bottom-entry control effects are captured by the axial power peaking factors present in the demonstration cases. Comparisons to integral experiments from the Halden IFA-681 experiments are discussed as initial validation. Reasonable comparisons are obtained for fuel centerline temperature and rod internal pressure as a function of time. In conclusion, simulations of additional experiments containing Gd 2 O 3 -bearing fuel are necessary to completely validate the code for BWR applications.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation of dilatancy-controlled gas migration processes in saturated bentonite using a coupled multiphase flow and elastoplastic H 2 M model

Dilatancy-controlled gas flow in preferential pathways plays a key role in the safety analysis of radioactive waste repositories. This is particularly the case for bentonite, an often-preferred barrier material. Gas flow in preferential pathways is characterized by localization and spontaneous behavior, which is challenging to simulate in numerical models due to strong hydro-mechanical coupling. To analyze a laboratory experiment in the framework of the DECOVALEX-2023 project, this study introduced a new approach of combining continuous modelling methods with spatial material properties derived from material heterogeneities and experimental observations. The proposed model utilized hydro-mechanical spatial distributions, namely Young's modulus and gas entry pressure, and elastoplasticity combined with a linear swelling model. A conceptual strain-dependent permeability approach simulated dilatancy-controlled gas flow based on hydro-mechanical coupling. To test the effectiveness of the presented approach, a gas injection test in a compacted, saturated bentonite sample was simulated using the open-source code OpenGeoSys 5.8 and compared with experimental observations. The presented methodology is capable of simulating localized gas flow in preferential pathways. The spatial distributions of Young's modulus and gas entry pressure affect the swelling pressure, relative permeability and, in combination with the strain-dependent permeability model, also the intrinsic permeability.

42 ENGINEERING↗

Circumferential or sectored beam arrangements for stereotactic body radiation therapy (SBRT) of primary lung tumors: Effect on target and normal-structure dose-volume metrics

To compare 2 beam arrangements, sectored (beam entry over ipsilateral hemithorax) vs circumferential (beam entry over both ipsilateral and contralateral lungs), for static-gantry intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 60 consecutive patients treated using stereotactic body radiation therapy (SBRT) for primary non–small-cell lung cancer (NSCLC) formed the basis of this study. Four treatment plans were generated per data set: IMRT/VMAT plans using sectored (-s) and circumferential (-c) configurations. The prescribed dose (PD) was 60 Gy in 5 fractions to 95% of the planning target volume (PTV) (maximum PTV dose ∼ 150% PD) for a 6-MV photon beam. Plan conformality, R{sub 50} (ratio of volume circumscribed by the 50% isodose line and the PTV), and D{sub 2} {sub cm} (D{sub max} at a distance ≥2 cm beyond the PTV) were evaluated. For lungs, mean doses (mean lung dose [MLD]) and percent V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} Gy were assessed. Spinal cord and esophagus D{sub max} and D{sub 5}/D{sub 50} were computed. Chest wall (CW) D{sub max} and absolute V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} {sub Gy} were reported. Sectored SBRT planning resulted in significant decrease in contralateral MLD and V{sub 10}/V{sub 5} {sub Gy}, as well as contralateral CW D{sub max} and V{sub 10}/V{sub 5} {sub Gy} (all p < 0.001). Nominal reductions of D{sub max} and D{sub 5}/D{sub 50} for the spinal cord with sectored planning did not reach statistical significance for static-gantry IMRT, although VMAT metrics did show a statistically significant decrease (all p < 0.001). The respective measures for esophageal doses were significantly lower with sectored planning (p < 0.001). Despite comparable dose conformality, irrespective of planning configuration, R{sub 50} significantly improved with IMRT-s/VMAT-c (p < 0.001/p = 0.008), whereas D{sub 2} {sub cm} significantly improved with VMAT-c (p < 0.001). Plan delivery efficiency improved with sectored technique (p < 0.001); mean monitor unit (MU)/cGy of PD decreased from 5.8 ± 1.9 vs 5.3 ± 1.7 (IMRT) and 2.7 ± 0.4 vs 2.4 ± 0.3 (VMAT). The sectored configuration achieves unambiguous dosimetric advantages over circumferential arrangement in terms of esophageal, contralateral CW, and contralateral lung sparing, in addition to being more efficient at delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Majorana Parts Tracking Database

The MAJORANA DEMONSTRATOR is an ultra-low background physics experiment searching for the neutrinoless double beta decay of 76Ge. The MAJORANA Parts Tracking Database is used to record the history of components used in the construction of the DEMONSTRATOR. Transportation, storage, and processes undergone by parts such as machining or cleaning are linked to part records. Tracking parts provides a great logistics benefit and an important quality assurance reference during construction. In addition, the location history of parts provides an estimate of their exposure to cosmic radiation. A web application for data entry and a radiation exposure calculator have been developed as tools for achieving the extreme radiopurity required for this rare decay search.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Controls on reservoir properties in organic-matter-rich shales: Insights from MICP analysis

Mercury injection capillary pressure (MICP) analysis was used to study organic-matter-rich Devonian shales varying in maturity from marginally mature to postmature to discuss controls on drainage and imbibition in shale reservoirs. Six samples come from the New Albany Shale; their total organic carbon (TOC) ranged from 3.3–8.4 % and vitrinite reflectance (R o ) from 0.54–1.42 %. One Marcellus Shale sample with R o 2.50 % was used to extend the maturity range to the advanced dry gas window. Three coal samples of varying rank were also included for comparison. Porosity of the shales ranges from 1.5–5.0 %, and MICP-derived permeability ranges from 0.17–9.9 mD. Injection capillary pressure curves have a range of entry pressures from 0.055 to0.421 MPa, and no relationship of entry pressure with maturity was revealed. Maturity, however, has an influence on pore size distribution, with the higher-maturity samples having significantly lower volumes of pores with throats less than 10 nm in diameter. Withdrawal capillary pressure curves document a wide range of withdrawal efficiencies from 55 % to almost 100 %, and pores having throats between 3–50 nm in diameter play a major role in the ability of mercury to be released from the pore system. The obtained data provide valuable information about shale properties and their behavior not only in the air-mercury system but also under reservoir conditions.

02 PETROLEUM↗

An exposure-response database for detailed toxicity data

Risk assessment for human health effects often depends on evaluation of toxicological literature from a variety of sources. Risk assessors have limited resources for obtaining raw data, performing follow-on analyses or initiating new studies. These constraints must be balanced against a need to improve scientific credibility through improved statistical and analytical methods that optimize the use of available information. Computerized databases are used in toxicological risk assessment both for storing data and performing predictive analyses. Many systems provide primarily either bibliographic information or summary factual data from toxicological studies; few provide adequate information to allow application of dose-response models. The Exposure-Response database (ERDB) described here fills this gap by allowing entry of sufficiently detailed information on experimental design and results for each study, while limiting data entry to the most relevant. ERDB was designed to contain information from the open literature to support dose-response assessment and allow a high level of automation in performance of various types of dose-response analyses. Specifically, ERDB supports emerging analytical approaches for dose-response assessment, while accommodating the diverse nature of published literature. Exposure and response data are accessible in a relational multi-table design, with closely controlled standard fields for recording values and free-text fields to describe unique aspects of the study. Additional comparative analyses are made possible through summary tables and graphic representations of the data contained within ERDB.

60 APPLIED LIFE SCIENCES↗