Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Energy Demands and Efficiency Strategies in Data Center Buildings

Information technology (IT) is becoming increasingly pervasive throughout society as more data is digitally processed, stored, and transferred. The infrastructure that supports IT activity is growing accordingly, and data center energy demands haveincreased by nearly a factor of four over the past decade. Data centers house IT equipment and require significantly more energy to operate per unit floor area thanconventional buildings. The economic and environmental ramifications of continued data center growth motivate the need to explore energy-efficient methods to operate these buildings. A substantial portion of data center energy use is dedicated to removing the heat that is generated by the IT equipment. Using economizers to introduce large airflow rates of outside air during favorable weather could substantially reduce the energy consumption of data center cooling. Cooling buildings with economizers is an established energy saving measure, but in data centers this strategy is not widely used, partly owing to concerns that the large airflow rates would lead to increased indoor levels of airborne particles, which could damage IT equipment. The environmental conditions typical of data centers and the associated potential for equipment failure, however, are not well characterized. This barrier to economizer implementation illustrates the general relationship between energy use and indoor air quality in building design and operation. This dissertation investigates how building design and operation influence energy use and indoor air quality in data centers and provides strategies to improve both design goals simultaneously.As an initial step toward understanding data center air quality, measurements of particle concentrations were made at multiple operating northern California data centers. Ratios of measured particle concentrations in conventional data centers to the corresponding outside concentrations were significantly lower than those reported in the literature for office or residential buildings. Estimates using a material-balance model match well with empirical results, indicating that the dominant particle sources and losses -- ventilation and filtration -- have been characterized. Measurements taken at a data center using economizers show nearly an order of magnitude increase in particle concentration during economizer activity. However, even with the increase, themeasured particle concentrations are still below concentration limits recommended in most industry standards. The research proceeds by exploring the feasibility of using economizers in data centers while simultaneously controlling particle concentrations with high-quality air filtration. Physical and chemical properties of indoor and outdoor particles were analyzed at a data center using economizers and varying levels of air filtration efficiency. Results show that when improved filtration is used in combination with an economizer, the indoor/outdoor concentration ratios for most measured particle types were similar to the measurements when using conventional filtration without economizers. An energy analysis of the data center reveals that, even during the summer months, chiller savings from economizer use greatly outweigh the increase in fan power associated with improved filtration. These findings indicate that economizer use combined with improved filtration couldsignificantly reduce data center energy demand while providing a level of protection from particles of outdoor origin similar to that observed with conventional design. The emphasis of the dissertation then shifts to evaluate the energy benefits of economizer use in data centers under different design strategies. Economizer use with high ventilation rates is compared against an alternative, water-side economizer design that does not affect indoor particle concentrations. Building energy models are employed to estimate energy savings of both economizer designs for data centers in

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Black carbon emissions from biomass and coal in rural China

Residential solid fuel combustion makes a major contribution to black carbon (BC) emissions in China. A new estimation of BC emissions from rural solid biomass and coal consumption has been derived from field survey data. The following new contributions are made: (1) emission factors are collected and reviewed; (2) household energy data are collected from field survey data and from the literature; (3) a new extrapolation method is developed to extend the field survey data to other locations; (4) the ownership and usage of two stove types are estimated and considered in the emission calculations; and (5) uncertainties associated with the estimation results are quantified. It is shown that rural households with higher income will consume less biomass but more coal. Agricultural acreage and temperature also significantly influence the amount of solid fuel consumed in rural areas. It is estimated that 640±245 Gg BC/y were emitted to the atmosphere due to residential solid fuel consumption in rural China in 2014. Emissions of BC from straw, wood, and coal contributed 42±13%, 36±15%, and 22±10% of the total, respectively. As a result, we show that effective BC mitigation (a reduction of 47%) could be obtained through widespread introduction of improved stoves in rural households

01 COAL, LIGNITE, AND PEAT↗

Application of automated measurement and verification to utility energy efficiency program data

Trustworthy savings calculations are critical to convincing regulators of both the cost-effectiveness of energy efficiency program investments and their ability to defer supply-side capital investments. Today’s methods for measurement and verification (M&V) of energy savings constitute a significant portion of the total costs of energy efficiency programs. They also require time-consuming data acquisition. A spectrum of savings calculation approaches is used, with some relying more heavily on measured data and others relying more heavily on estimated, modeled, or stipulated data. The increasing availability of “smart” meters and devices that report near-real time data, combined with new analytical approaches to quantify savings, offers the potential to conduct M&V more quickly and at lower cost, with comparable or improved accuracy. Commercial energy management and information systems (EMIS) technologies are beginning to offer these ‘M&V 2.0’ capabilities, and program administrators want to understand how they might assist programs in quickly and accurately measuring energy savings. This paper presents the results of recent testing of the ability to use automation to streamline the M&V process. In this paper, we apply an automated whole-building M&V tool to historic data sets from energy efficiency programs to begin to explore the accuracy, cost, and time trade-offs between more traditional M&V, and these emerging streamlined methods that use high-resolution energy data and automated computational intelligence. For the data sets studied we evaluate the fraction of buildings that are well suited to automated baseline characterization, the uncertainty in gross savings that is due to M&V 2.0 tools’ model error, and indications of labor time savings, and how the automated savings results compare to prior, traditionally determined savings results. The results show that 70% of the buildings were well suited to the automated approach. In a majority of the cases (80%) savings and uncertainties for each individual building were quantified to levels above the criteria in ASHRAE Guideline 14. In addition the findings suggest that M&V 2.0 methods may also offer time-savings relative to traditional approaches. Lastly, we discuss the implications of these findings relative to the potential evolution of M&V, and pilots currently being launched to test how M&V automation can be integrated into ratepayer-funded programs and professional implementation and evaluation practice.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hard X-Ray Detection of the High Redshift Quasar 4C 71.07

BATSE/OSSE observations of the high redshift quasar 4C 71.07 indicate that this is the brightest and furthest AGN so far detected 20 keV. BATSE Earth occultation data have been used to search for emission from 4C 71.07 from nearly 3 years of observation. The mean source flux over the- whole period in the BATSE energy range 20-100 keV is (13.2 +/- 1.06) x 10(exp -11) erg/square cm/s corresponding to a luminosity of 2 x 10(exp 48 erg/s. The BATSE light curve over the 3 years of observations shows several flare-like events, one of which (in January 1996) is associated with an optical flare (R=16.1) but with a delay of 55 days. The OSSE/BATSE spectral analysis indicates that the source is characterized by a flat power spectrum (Gamma is approximately 1.1- 1.3) when in a low state: this spectral form is consistent within errors with the ASCA and ROSAT spectra. This means that the power law observed from 0.1 to 10 keV extends up to at least 1 MeV but steepens soon after to meet EGRET high energy data. BATSE data taken around the January 1996 flare suggests that the spectrum could be steeper when the source is in a bright state. The upsilon-F-upsilon representation of the source is typical of a low frequency peaked/ gamma- ray dominated blazar, with the synchrotron peak in the mm-FIR band and the Compton peak in the MeV band. The BATSE and OSSE spectral data seem to favour a model in which the high energy - flux is due to the sum of the synchrotron self-Compton and the external Compton contributions: this is also supported by the- variability behaviour of the source.

Malizia, A.↗

Exclusive rho^0 electroproduction on the proton at CLAS

The $e p\to e^\prime p \rho^0$ reaction has been measured, using the 5.754 GeV electron beam of Jefferson Lab and the CLAS detector. This represents the largest ever set of data for this reaction in the valence region. Integrated and differential cross sections are presented. The $W$, $Q^2$ and $t$ dependences of the cross section are compared to theoretical calculations based on $t$-channel meson-exchange Regge theory on the one hand and on quark handbag diagrams related to Generalized Parton Distributions (GPDs) on the other hand. The Regge approach can describe at the $\approx$ 30% level most of the features of the present data while the two GPD calculations that are presented in this article which succesfully reproduce the high energy data strongly underestimate the present data. The question is then raised whether this discrepancy originates from an incomplete or inexact way of modelling the GPDs or the associated hard scattering amplitude or whether the GPD formalism is simply in

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Squarks and Gluinos with the D0 detector

We report on D0 searches for scalar quarks ({tilde q}) and gluinos ({tilde g}), the superpartners of quark and gluons, in topologies involving jets and missing transverse energies. Data samples obtained with D0 detector from p{bar p} collisions at a center-of-mass energy of 1.96 TeV corresponding to an integrated luminosities of 1-4 fb{sup -1} were analyzed. No evidence for the production of such particles were observed and lower limits on squarks and gluino masses were set.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Projected Operational Energy Life Cycle Data Development: 2025 Update

This report documents the data sources and methods used to develop the energy life cycle data for use by the National Institute of Standards and Technology (NIST) Engineering Laboratory (EL) to be used for the development of measurement science and incorporation into decision-support tools for evaluating building and facility capital investments. The data are posted separately under DOI 10.18141/2575194.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dark Energy Survey Year 1 Results: Photometric Data Set for Cosmology

Here, we describe the creation, content, and validation of the Dark Energy Survey (DES) internal year-one cosmology data set, Y1A1 GOLD, in support of upcoming cosmological analyses. The Y1A1 GOLD data set is assembled from multiple epochs of DES imaging and consists of calibrated photometric zeropoints, object catalogs, and ancillary data products -e.g., maps of survey depth and observing conditions, star-galaxy classification, and photometric redshift estimates|that are necessary for accurate cosmological analyses. The Y1A1 GOLD wide-area object catalog consists of 137 million objects detected in coadded images covering 1800 deg 2 in the DES grizY filters. The 10 limiting magnitude for galaxies is g = 23.4, r = 23.2, i = 22.5, z = 21.8, and Y = 20.1. We also performed photometric calibration of Y1A1 GOLD by combining nightly zeropoint solutions with stellar-locus regression, and the absolute calibration accuracy is better than 2% over the survey area. DES Y1A1 GOLD is the largest photometric data set at the achieved depth to date, enabling precise measurements of cosmic acceleration at z ≲1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recovery Act: Energy Efficiency of Data Networks through Rate Adaptation (EEDNRA) - Final Technical Report

This Concept Definition Study focused on developing a scientific understanding of methods to reduce energy consumption in data networks using rate adaptation. Rate adaptation is a collection of techniques that reduce energy consumption when traffic is light, and only require full energy when traffic is at full provisioned capacity. Rate adaptation is a very promising technique for saving energy: modern data networks are typically operated at average rates well below capacity, but network equipment has not yet been designed to incorporate rate adaptation. The Study concerns packet-switching equipment, routers and switches; such equipment forms the backbone of the modern Internet. The focus of the study is on algorithms and protocols that can be implemented in software or firmware to exploit hardware power-control mechanisms. Hardware power-control mechanisms are widely used in the computer industry, and are beginning to be available for networking equipment as well. Network equipment has different performance requirements than computer equipment because of the very fast rate of packet arrival; hence novel power-control algorithms are required for networking. This study resulted in five published papers, one internal report, and two patent applications, documented below. The specific technical accomplishments are the following: • A model for the power consumption of switching equipment used in service-provider telecommunication networks as a function of operating state, and measured power-consumption values for typical current equipment. • An algorithm for use in a router that adapts packet processing rate and hence power consumption to traffic load while maintaining performance guarantees on delay and throughput. • An algorithm that performs network-wide traffic routing with the objective of minimizing energy consumption, assuming that routers have less-than-ideal rate adaptivity. • An estimate of the potential energy savings in service-provider networks using feasibly-implementable rate adaptivity. • A buffer-management algorithm that is designed to reduce the size of router buffers, and hence energy consumed. • A packet-scheduling algorithm designed to minimize packet-processing energy requirements. Additional research is recommended in at least two areas: further exploration of rate-adaptation in network switching equipment, including incorporation of rate-adaptation in actual hardware, allowing experimentation in operational networks; and development of control protocols that allow parts of networks to be shut down while minimizing disruption to traffic flow in the network. The research is an integral part of a large effort within Bell Laboratories, Alcatel-Lucent, aimed at dramatic improvements in the energy efficiency of telecommunication networks. This Study did not explicitly consider any commercialization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electric Vehicle Grid Interaction Exploration: Cooperative Research and Development Final Report, CRADA Number CRD-11-431

Under this agreement NREL plans to collect, analyze, and share with Xcel Energy data regarding the driving and charging performance of plug-in electric vehicles. NREL will research activities critical to energy storage, electric propulsion, and the emerging issues surrounding the integration of vehicles into the current and future grid. It will provide NREL with access to one of the firstall-electric vehicles available in the market as part of NREL's Advanced Technology Vehicle Fleet (ATVF).

25 ENERGY STORAGE↗

Occupant Behavior for Energy Conservation in Commercial Buildings: Lessons Learned from Competition at the Oak Ridge National Laboratory

Accompanying efforts worldwide to deploy sustainable building technologies shows a pressing need for expanded research on occupant behavior. Discourse is lacking concerning drivers of occupant behavior for energy conservation, especially in the case of commercial buildings. This paper explores potential determinants of occupant behavior for energy conservation in commercial buildings. This is investigated in a case study of a two-month energy conservation competition involving eight office buildings at the Oak Ridge National Laboratory. Four buildings achieved energy savings based on the previous year’s baseline. Potential challenges and success factors of occupant behavior for energy conservation during the competition were explored based on an explanatory research design incorporating energy data, participant interviews, and surveys. The findings suggest that both social and technological aspects may be important drivers of energy conservation. The determinants of occupant behavior for energy conservation in commercial buildings suggested for further research include bottom-up involvement, stakeholder relationship management, targeted information, real-time energy visualization, and mobile social platforms. This paper presents initial implications, with a need for further research on these propositions and on their impacts on occupant behavior. This paper aims to contribute to both academia and practitioners in the arena of commercial building sustainability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A study of geothermal prospects in the western United States

The commercial development potential of 13 underdeveloped geothermal prospects in the Western United States was examined, and the prospects were ranked in order of relative potential for development on the basis of investment considerations. The following were considered in the ranking: geotechnical and engineering data, energy market accessibility, administrative constraints, and environmental and socio-economic factors. The primary ranking criterion is the unit cost of energy production expected from each prospect. Secondary criteria are administrative constraints, environmental factors and the quality of the geotechnical data.

Source record↗

Energy Remote Sensing Applications Projects at the NASA Ames Research Center

The NASA Ames Research Center is active in energy projects primarily in the role of providing assistance to users in the solution of a number of problems related to energy. Data bases were produced which can be used, in combination with other sources of information, to solve spatially related energy problems. Six project activities at Ames are described which relate to energy and remote sensing. Two projects involve power demand forecasting and estimations using remote sensing and geographic information systems; two others involve transmission line routing and corridor analysis; one involves a synfuel user needs assessment through remote sensing; and the sixth involves the siting of energy facilities.

Norman, S. D.↗

A comprehensive solar energy system analysis data base in Huntsville, Alabama

The history of a comprehensive solar energy system analysis data base developed by NASA/Marshall Space Flight Center and the University of Alabama is presented, along with its current status. The Marshall Information Retrieval and Data Storage (MIRADS) system was chosen for the data base, and feedback systems were arranged to cope with changes in the needs of the program management for the type of data gathered. The final structure of the data base consists of 22 files divided into 6 topical sections: summaries, climatological, utility rates, architectural, equipment, and economics. The data base offers help to the solar industry in two ways: it provides information and it serves as a model for users trying to establish the climatic and socioeconomic variables they should take into account when they examine a potential market for solar energy equipment.

Goddard, J. P.↗

Evaluating the Methodologies of Assessing Long-Term Variability of Wind Speed

Wind resources vary from year to year, and hence the long-term variability of wind speed is a key component of the overall uncertainty in the wind resource assessment process. Because wind-turbine power generation is highly sensitive to wind speed, the variability of wind resources has important implications for renewable power production. As many approaches of calculating the spread of distribution exist, we aim to identify the methods most appropriate for all types of wind-speed distributions. We review and compare various methods, such as the Coefficient of Variation (CoV) and the Robust Coefficient of Variation (RCoV). Because the length of data available also affects the resultant spread, we determine the minimum length of wind-speed records to quantify variability accurately. We use the net monthly energy production of 607 wind farms in the United States from the Energy Information Administration and the wind speeds of the MERRA-2 reanalysis dataset from NASA. After filtering the energy data via linear regression, we assess the accuracy of the variability calculations by comparing the correlations between the wind-speed variability estimates and the variabilities of wind-farm power productions. Results from statistically robust and resistant methods yield higher correlations between wind-speed and energy-production variabilities, as robust methods do not assume Gaussian wind-speed distributions and resistant methods are insensitive to wind speed extremes. We recommend RCoV to systematically estimate long-term variability, with 10 years of monthly mean data to achieve 90% statistical confidence. We will also provide generalized guidance on how to estimate long-term variability including case studies where we identify regions with high wind speeds and low wind-speed RCoVs, such as the Great Plains and the Upper Midwest in central United States.

17 WIND ENERGY↗

EDX ClaiMM

EDX ClaiMM is a centralized data & analytical platform designed to revolutionize U.S. critical minerals and materials (CMM) activities. By providing a robust digital infrastructure, ClaiMM will accelerate the combination, leveraging, and rapid utilization of vital data, advanced tools, and cutting-edge research advancements in CMM. This adaptive digital research hub connects the CMM community to essential knowledge products and offers access to interoperable datasets, databases, models, software, and tools from the National Energy Technology’s (NETL’s) Energy Data eXchange (EDX) and other authoritative sources, serving both public and private sectors. EDX ClaiMM delivers AI-informed solutions to address fundamental knowledge gaps and fosters the innovation of new techniques for enhanced characterization and recovery of CMMs within the U.S. By leveraging cloud-hosted, scalable digital infrastructure, ClaiMM meets public–private applied energy needs. It equips the CMM community with priority digital resources that harness on-site and cloud compute capabilities, enabling big data storage, advanced processing, analytics, and visualization.

Critical Materials; Critical Minerals; Rare Earth ↗

Helium interaction with solutes and impurities in neutron-irradiated nanostructured ferritic alloys: A first principles study

Density functional theory calculations are performed to explore the binding between He and alloying solutes, impurities, and transmutation products expected in neutron irradiated nanostructured ferritic alloys (NFAs), here 14YWT is taken as an example. Elements that exhibit significant binding (attraction) with an interstitial He are Y (binding energy = 0.46 eV), Mg (0.32), O (0.33), Ti (0.16), and C (0.15). Those that provide significant binding to a substitutional He are O (1.44), Y (1.24), N (0.73), H (0.56), Mg (0.52), Ti (0.34), Si (0.34), C (0.33), Al (0.32), Ni (0.26), Ta (0.23), and Mn (0.16). The presence of these elements in Fe matrix could reduce the transport of He towards oxide particles, dislocations, and internal boundaries, and could promote He bubble nucleation in the matrix. For convenience, we compile existing binding energy data of He with He n and He n V (He-vacancy) clusters. Dissociation pathway analysis reveals that, in general, the most likely dissociation of a He n V cluster is by a sequential emission of individual He atoms. Furthermore, larger bubbles are more prone to dissociation than smaller ones. In addition, we estimate the binding energy (segregation energy) of He in bulk Y 2 Ti 2 O 7 (YTO) single crystal, YTO/Fe interface, and YTO particle embedded in Fe, with respect to interstitial He in Fe, from existing formation energies of He in these structures. We also compile available data of He binding with Fe self-interstitial atom (SIA), SIA clusters, and edge and screw dislocations. Note that given the absence of DFT data, the binding with SIA clusters and dislocations are gathered from simulations with empirical potentials. Finally, the data presented in this paper is important to inform multiscale simulations of He bubble accumulation.

36 MATERIALS SCIENCE↗