Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “enclosure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet)

Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent "package" of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community

Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent 'package' of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pseudo-Glassification Material for G-Demption

G-Demption, LLC has requested that PPNL provide design input for a “pseudo-glassification” process associated with their proposed technology for generating gamma irradiation stations from used nuclear fuel. The irradiation design currently consists of an aluminum enclosure designed to allow for proper encapsulation of and heat flow from a used fuel rod while minimally impacting the streaming of gamma rays from the fuel. In order to make their design more robust, G-Demption is investigating the benefits of backfilling this aluminum enclosure with a setting material once the used fuel rod is properly placed. This process has been initially referred to as “pseudo-glassification”, and strives not to impact heat transport or gamma streaming from the used fuel rod while providing increased fuel rod protection and fission gas retention. PNNL has compiled an internal material evaluation and discussion for the “pseudo-glassification” process in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Assessment of Envelope Measures in Mild Climate Deep Energy Retrofits

Energy end-uses and interior comfort conditions have been monitored in 11 Deep Energy Retrofits (DERs) in a mild marine climate. Two broad categories of DER envelope were identified: first, bringing homes up to current code levels of insulation and airtightness, and second, enhanced retrofits that go beyond these code requirements. The efficacy of envelope measures in DERs was difficult to determine, due to the intermingled effects of enclosure improvements, HVAC system upgrades and changes in interior comfort conditions. While energy reductions in these project homes could not be assigned to specific improvements, the combined effects of changes in enclosure, HVAC system and comfort led to average heating energy reductions of 76percent (12,937 kWh) in the five DERs with pre-retrofit data, or 80percent (5.9 kWh/ft2) when normalized by floor area. Overall, net-site energy reductions averaged 58percent (15,966 kWh; n=5), and DERs with code-style envelopes achieved average net-site energy reductions of 65percent (18,923 kWh; n=4). In some homes, the heating energy reductions were actually larger than the whole house reductions that were achieved, which suggests that substantial additional energy uses were added to the home during the retrofit that offset some heating savings. Heating system operation and energy use was shown to vary inconsistently with outdoor conditions, suggesting that most DERs were not thermostatically controlled and that occupants were engaged in managing the indoor environmental conditions. Indoor temperatures maintained in these DERs were highly variable, and no project home consistently provided conditions within the ASHRAE Standard 55-2010 heating season comfort zone. Thermal comfort and heating system operation had a large impact on performance and were found to depend upon the occupant activities, so DERs should be designed with the occupants needs and patterns of consumption in mind. Beyond-code building envelopes were not found to be strictly necessary for the achievement of deep energy savings in existing uninsulated homes in mild marine climates, provided that other energy end-uses were comprehensively reduced. We recommend that mild climate DERs pursue envelopes in compliance with the 2012 International Energy Conservation Code (IECC) and pair these with high efficiency, off-the-shelf HVAC equipment. Enhanced building envelopes should be considered in cases where very low heating energy use (<1,000 kWh/year or <0.5 kWh/ft2-year) and enhanced thermal comfort (ASHRAE 55-2010) are required, as well as in those situations where substantial energy uses are added to the home, such as decorative lighting, cooling or smart home A/V and communication equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Energy Retrofits - Eleven California Case Studies

This research documents and demonstrates viable approaches using existing materials, tools and technologies in owner-conducted deep energy retrofits (DERs). These retrofits are meant to reduce energy use by 70% or more, and include extensive upgrades to the building enclosure, heating, cooling and hot water equipment, and often incorporate appliance and lighting upgrades as well as the addition of renewable energy. In this report, 11 Northern California (IECC climate zone 3) DER case studies are described and analyzed in detail, including building diagnostic tests and end-use energy monitoring results. All projects recognized the need to improve the home and its systems approximately to current building code-levels, and then pursued deeper energy reductions through either enhanced technology/ building enclosure measures, or through occupant conservation efforts, both of which achieved impressive energy performance and reductions. The beyond-code incremental DER costs averaged $25,910 for the six homes where cost data were available. DERs were affordable when these incremental costs were financed as part of a remodel, averaging a $30 per month increase in the net-cost of home ownership.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Module-Integrated Power Converters Based on Universal Dock

Solar power installations using alternating current photovoltaic (ACPV) modules have significant cost and performance advantages over systems using conventional solar modules and string inverters. ACPV modules have improved energy harvest due to module-level power point tracking and redundancy. More importantly, ACPV modules are easier and cheaper to install, lowering the total installed cost, indirect costs, and barriers to market entry. Furthermore, ACPV modules have communications and data logging capability, yielding module-level telemetry data that is useful in site diagnostics and other data applications. The products of these efforts were threefold. First, an advanced microinverter power topology was developed, modeled, simulated, and tested. Second, new microinverter enclosure concepts were developed and tested. Third, a new ACPV module prototype was constructed, combining the power topology and the enclosure concepts. SolarBridge filed for patents in each of these areas and is transitioning the project from a concept phase to full development.

14 SOLAR ENERGY↗

Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program

This research project evaluates post-retrofit performance measurements, energy use data and construction costs for 13 projects that participated in the National Grid Deep Energy Retrofit Pilot program. The projects implemented a package of measures defined by performance targets for building enclosure components and building enclosure air tightness. Nearly all of the homes reached a post-retrofit air tightness result of 1.5 ACH 50. Homes that used the chainsaw retrofit technique along with roof insulation, and wall insulation applied to the exterior had the best air tightness results and the lowest heating and cooling source energy use. Analysis of measure costs and project objectives yielded a categorization of costs relative to energy performance objectives. On average about ½ of the energy-related measure costs correspond primarily to energy-related objectives, and 20% of energy-related measure costs relate primarily to non-energy objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community

Between December, 2009 and December, 2012, 42 deep energy retrofit (DER) projects were completed through a pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. Thirty-seven of these projects were comprehensive retrofits while five were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. Building Science Corporation developed a consistent "package" of measures in terms of the performance targeted for major building components. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sampling and analysis plan for assessment of beryllium in soils surrounding TA-40 building 15

Technical Area (TA) 40 Building 15 (40-15) is an active firing site at Los Alamos National Laboratory. The weapons facility operations (WFO) group plans to build an enclosure over the site in 2017, so that test shots may be conducted year-round. The enclosure project is described in PRID 16P-0209. 40-15 is listed on LANL OSH-ISH’s beryllium inventory, which reflects the potential for beryllium in/on soils and building surfaces at 40-15. Some areas in and around 40-15 have previously been sampled for beryllium, but past sampling efforts did not achieve complete spatial coverage of the area. This Sampling and Analysis Plan (SAP) investigates the area surrounding 40-15 via 9 deep (≥1-ft.) soil samples and 11 shallow (6-in.) soil samples. These samples will fill the spatial data gaps for beryllium at 40-15, and will be used to support OSH-ISH’s final determination of 40-15’s beryllium registry status. This SAP has been prepared by the Environmental Health Physics program in consultation with the Industrial Hygiene program. Industrial Hygiene is the owner of LANL’s beryllium program, and will make a final determination with regard to the regulatory status of beryllium at 40-15.

54 ENVIRONMENTAL SCIENCES↗

Determining the Coalescence of Hotspots into Uniform Detonation Fronts in High Explosives

Microwave Interferometry (MI) offers the advantage of a continuous time measurement of detonation front velocity from detonation initiation to disassembly, which is an important step to assure the quality of stockpile high explosives. However, the method is currently characterized by areas of poor signal strength, which lead to low confidence measurements. Experiments in inert materials were conducted to determine if reflective hot spots, pockets of plasma that form during detonation, are responsible due to varying hot spot concentrations. Instead, it was found that the copper tube used in a range of standard HE test configurations is the cause of the poor signal reception. Hot spots were represented by microwave reflective aluminum particles. The aluminum was mixed with Titanium Dioxide, a material electrically similar to the insensitive high explosive, triaminotrinitrobenzene (TATB), in volume percent fractions (VPFs) between 0 and 100% aluminum, in increments of 10%. Reflectivity was measured based on input and reflection received from a test apparatus with a layer representing undetonated explosive and another representing an approaching shockwave. The results showed no correlation between VPF and measured reflectivity test cases while enclosed in the standard copper tube. Upon further testing, each sample’s measured reflectivity independent of the copper enclosure did correlate with VPF. This revealed that the test enclosure currently used for MI measurements is causing poor MI signal reception, and new methods must be developed to account for this aberration in MI measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extraction of Uranium from Seawater: Design and Testing of a Symbiotic System (Final Report)

The U.S. Department of Energy in October 2014 awarded the Massachusetts Institute of Technology (MIT) a Nuclear Energy University Program grant (DE-NE0008268) to investigate the design and testing of a symbiotic system to harvest uranium from seawater. As defined in the proposal, the goals for the project are: 1. Address the design of machines for seawater uranium mining. 2. Develop design rules for a uranium harvesting system that would be integrated into an offshore wind power tower. 3. Fabricate a 1/50th size scale prototype for bench and pool-testing to verify initial analysis and theory. 4. Design, build, and test a second 1/10th size scale prototype in the ocean for more comprehensive testing and validation. This report describes work done as part of DE-NE0008268 from 10/01/2014 to 11/30/2017 entitled, “Extraction of Uranium from Seawater: Design and Testing of a Symbiotic System.” This effort is part of the Seawater Uranium Recovery Program. This report details the publications and presentations to date on the project, an introduction to the project’s goals and background research into previous work done to achieve these goals thus far. From there, the report describes an algorithm developed during the project used to optimize the adsorption of uranium by changing mechanical parameters such as immersion time and adsorbent reuses is described. Next, a design tool developed as part of the project to determine the global feasibility of symbiotic uranium harvesting systems. Additionally, the report details work done on shell enclosures for uranium adsorption. Moving on, the results from the design, building, and testing of a 1/50th physical scale prototype of a highly feasible symbiotic uranium harvester is described. Then, the report describes the results from flume experiment used to determine the affect of enclosure shells on the uptake of uranium by the adsorbent they enclose. From there the report details the design of a Symbiotic Machine for Ocean uRanium Extraction (SMORE). Next, the results of the 1/10th scale physical scale prototype of a highly feasible symbiotic uranium harvester are presented. The report then details the design and results of an experiment to examine the hydrodynamic effects of a uranium harvester on the offshore wind turbine it is attached to using a 1/150th Froude scale tow tank test. Finally, the report details the results of an initial cost-analysis for the production of uranium from seawater from such a symbiotic device.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extraction of Uranium from Seawater: Design and Testing of a Symbiotic System

The U.S. Department of Energy in October 2014 awarded the Massachusetts Institute of Technology (MIT) a Nuclear Energy University Program grant (DE-NE0008268) to investigate the design and testing of a symbiotic system to harvest uranium from seawater. As defined in the proposal, the goals for the project are: 1. Address the design of machines for seawater uranium mining. 2. Develop design rules for a uranium harvesting system that would be integrated into an offshore wind power tower. 3. Fabricate a 1/50th size scale prototype for bench and pool-testing to verify initial analysis and theory. 4. Design, build, and test a second 1/10th size scale prototype in the ocean for more comprehensive testing and validation. This report describes work done as part of DE-NE0008268 from 10/01/2014 to 11/30/2017 entitled, “Extraction of Uranium from Seawater: Design and Testing of a Symbiotic System.” This effort is part of the Seawater Uranium Recovery Program. This report details the publications and presentations to date on the project, an introduction to the project’s goals and background research into previous work done to achieve these goals thus far. From there, the report describes an algorithm developed during the project used to optimize the adsorption of uranium by changing mechanical parameters such as immersion time and adsorbent reuses is described. Next, a design tool developed as part of the project to determine the global feasibility of symbiotic uranium harvesting systems. Additionally, the report details work done on shell enclosures for uranium adsorption. Moving on, the results from the design, building, and testing of a 1/50th physical scale prototype of a highly feasible symbiotic uranium harvester is described. Then, the report describes the results from flume experiment used to determine the affect of enclosure shells on the uptake of uranium by the adsorbent they enclose. From there the report details the design of a Symbiotic Machine for Ocean uRanium Extraction (SMORE). Next, the results of the 1/10th scale physical scale prototype of a highly feasible symbiotic uranium harvester are presented. The report then details the design and results of an experiment to examine the hydrodynamic effects of a uranium harvester on the offshore wind turbine it is attached to using a 1/150th Froude scale tow tank test. Finally, the report details the results of an initial cost-analysis for the production of uranium from seawater from such a symbiotic device.

42 ENGINEERING↗

Additive Manufacturing of Parts and Tooling in Robotic Systems

ORNL worked with Transcend Robotics, LLC to explore additive manufacturing of the two-piece compression body for their ARTI mobile robot platform. Extrusion compression molding was identified as an effective means of manufacturing these parts. ORNL consulted on modifications to the housing design to accommodate the selected manufacturing process. Parts were printed using ORNL's FDM machines for testing and evaluation of the design as a precursor to molding the parts. The assembly and evaluation of the parts proved favorable and minor design changes to improve assembly and performance were identified.The goal is to develop a light weight and rugged two-part robotic enclosure for an unmanned ground vehicle UGV) that will be used in search and rescue applications. The FDM parts fabricated by ORNL allowed Transcend Robotics to assemble a prototype robot and verify that the new parts will meet the performance requirements. ORNL fabricated enclosure parts out of ABS and Nylon 12 materials such that the design could be tested prior to fabricating tooling for compression molding of Nylon 6 with carbon fiber fill. The robot was performance tested and compared with the previous manufacturing techniques and found to have superior performance.

42 ENGINEERING↗

Moisture Performance of High-R Wall Systems

High-performance homes offer improved comfort, lower utility bills, and assured durability. The next generation of building enclosures is a key step toward achieving high-performance goals through decreasing energy load demand and enabling advanced space-conditioning systems. Yet the adoption of high-R enclosures and particularly high-R walls has been a slow-growing trend because mainstream builders are hesitant to make the transition. In a survey of builders on this topic, one of the challenges identified is an industry-wide concern about the long-term moisture performance of energy-efficient walls. This study takes a step toward addressing this concern through direct monitoring of the moisture performance of high-R walls in occupied homes in several climate zones. In addition, the robustness of the design and modeling tools for selecting high-R wall solutions is evaluated using the monitored data from the field. The information and knowledge gained through this research will provide an objective basis for decision-making so that builders can implement advanced designs with confidence.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Performance of High-R Wall Systems

High-performance homes offer improved comfort, lower utility bills, and assured durability. The next generation of building enclosures is a key step toward achieving high-performance goals through decreasing energy load demand and enabling advanced space-conditioning systems. Yet the adoption of high-R enclosures and particularly high-R walls has been a slow-growing trend because mainstream builders are hesitant to make the transition. In a survey of builders on this topic, one of the challenges identifi ed is an industry-wide concern about the long-term moisture performance of energy-effi cient walls. This study takes a step toward addressing this concern through direct monitoring of the moisture performance of high-R walls in occupied homes in several climate zones. In addition, the robustness of the design and modeling tools for selecting high-R wall solutions is evaluated using the monitored data from the field. The information and knowledge gained through this research will provide an objective basis for decision-making so that builders can implement advanced designs with confidence.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local Radiation Shielding Design Methodology

The NSLS-II accelerators are housed within a radiation enclosure of normal concrete (and in some places high density concrete) that has been designed to reduce the radiation generated from an assumed operational beam loss or bulk shielding current (BCS) from each accelerator. The beam loss model used to estimate the thickness of this bulk shielding, assumed a beam energy at the expected operating energy and a current loss based on reasonable assumptions for the fraction of the expected operating current. The thickness of the shield was determined to be the amount required to reduce the radiation outside the shield to a maximum dose rate of <0.5mrem/hr. for occupied areas for these normal operational losses. These assumed beam losses and the bulk shielding thicknesses required are given in reference [1]. Abnormal operating conditions generating higher than normal beam losses must also be considered, and additional engineering controls will be required depending on the magnitude of the radiation levels generated during the abnormal condition. Additional local shielding subject to configuration control may be utilized to reduce radiation levels associated with these abnormal loss conditions. Interlocked area radiation monitors are another means to prevent continued operation with higher than an acceptable level. The NSLS-II Shielding Policy requires that an engineered system be utilized to mitigate an abnormal condition producing radiation levels greater than 100 mR/h, and that two systems are required if the projected radiation levels during a fault condition are > 2000 mR/h. It is intended that shielding limits the dose rate to < 0.5 mR/h in occupied areas for normal operational losses, and the combination of administrative and engineered controls for abnormal losses will maintain radiation exposure to trained personnel working at the NSLS-II facility to as low as reasonably achievable. It is anticipated that all individual exposures will be well within the planned administrative control level of 100mrem/year. This technical note presents the method used to identify these potential high beam loss locations, evaluate the potential radiation risk these losses create outside the enclosure shield and the design process that specifies the required local radiation shielding needed to reduce this risk below the maximum dose rate of the bulk shield design, listed above. If shielding can’t be adequately provided or if other fault initiated losses could occur, then the necessary engineering controls will be indicated that will limit the energy, current or duration of the beam transport that constitute this high beam loss risk.

36 MATERIALS SCIENCE↗

AFCI Glovebox Radiological Release - Evaluation, Corrective Actions and Testing

Scope of Report Releases of airborne radioactivity occurred in the Advanced Fuel Cycle Initiative (AFCI) glovebox enclosure (room) located in the Fuel Manufacturing Facility (FMF) at the Idaho National Laboratory (INL) in late August and early September, 2014. The subsequent investigation activities identified two primary issues: 1) The AFCI glovebox confinement was compromised providing a pathway for airborne radiological contamination releases, particularly when arc melting activities with transuranics were performed. 2) The Continuous Air Monitors (CAMs) located in the AFCI enclosure did not correctly identify americium (Am)-241 (predominant isotope in release) and provided nonconservative responses. This report documents the results of the investigations into both issues and the corrective actions taken. Finally, lessons learned are provided.

99 GENERAL AND MISCELLANEOUS↗

An Online Beam Loss Monitor for NSLS-II Storage Ring

Reliable beam loss monitors are important tools for the safe operation of the accelerators. Beam loss monitors provide valuable information on the magnitude and location of the particle beam loss inside the accelerator enclosures. In the synchrotron radiation facilities, the electron accelerator enclosures experience a mixed radiation environment, consisting of low energy x-ray background along with bremsstrahlung and photoneutrons.

36 MATERIALS SCIENCE↗