Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronics analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Collecting efficiency of a cylindrical mirror electron energy analyzer with pre-retarding lens

The electron collecting efficiency of a cylindrical mirror energy analyzer incorporating retardation of the electrons prior to analysis has been determined over the range 0 to 30 eV by two methods. The first method requires the use of a vacuum ultraviolet monochromator to produce monoenergetic electrons of different energies; the second method involves measuring the energy-brightness relationship of the retarding optics and should be applicable to any deflection analyzer with pre-retarding optics. The results of the two methods are compared and the limitations of the latter method are discussed.

Gardner, J. L.↗

Final Results of Shuttle MMOD Impact Database

The Shuttle Hypervelocity Impact Database documents damage features on each Orbiter thought to be from micrometeoroids (MM) or orbital debris (OD). Data is divided into tables for crew module windows, payload bay door radiators and thermal protection systems along with other miscellaneous regions. The combined number of records in the database is nearly 3000. Each database record provides impact feature dimensions, location on the vehicle and relevant mission information. Additional detail on the type and size of particle that produced the damage site is provided when sampling data and definitive spectroscopic analysis results are available. Guidelines are described which were used in determining whether impact damage is from micrometeoroid or orbital debris impact based on the findings from scanning electron microscopy chemical analysis. Relationships assumed when converting from observed feature sizes in different shuttle materials to particle sizes will be presented. A small number of significant impacts on the windows, radiators and wing leading edge will be highlighted and discussed in detail, including the hypervelocity impact testing performed to estimate particle sizes that produced the damage.

Hyde, J. L.↗

Double-probe potential measurements near the Spacelab 2 electron beam

As part of the Spacelab 2 mission the plasma diagnostics package (PDP) was released from the shuttle as a free-flying satellite. The PDP carried a quasi-static electric field instrument which made differential voltage measurements between two floating probes. At various times during the free flight, an electron beam was ejected from the shuttle. Large differential voltages between the double probes were recorded in association with the electron beam. However, analysis indicates that these large signals are probably not caused by ambient electric fields. Instead, they can be explained by considering three effects: shadowing of the probes from streaming electrons by the PDP chassis, crossing of the PDP wake by the probes, and spatial gradients in the fluxes of energetic electrons reaching the probes. Plasma measurements on the PDP show that energetic electrons exist in a region 20 m wide and up to at least 170 m downstream from the electron beam. At 80 or more meters downstream from the beam, the double probe measurements show that the energetic electron flux is opposite to the injection direction, as would be expected for a secondary returning electron beam produced by scattering of the primary electron beam.

Steinberg, J. T.↗

Lunar deep drill apparatus

Proposed as a baseline configuration, this rotary drill apparatus is designed to produce 100-mm diameter holes in the lunar surface at depths up to 50 meters. The drill is intended to acquire samples for scientific analysis, mineral resource location, calibration of electronic exploration devices, and foundation analysis at construction sites. It is also intended to prepare holes for emplacement of scientific instruments, the setting of structural anchors, and explosive methods in excavation and mining activities. Defined as a deep drill because of the modular drill string, it incorporates an automatic rod changer. The apparatus is teleoperated from a remote location, such as earth, utilizing supervisory control techniques. It is thus suitable for unmanned and man-tended operation. Proven terrestrial drilling technology is used to the extent it is compatible with the lunar environment. Augers and drive tubes form holes in the regolith and may be used to acquire loose samples. An inertial cutting removal system operates intermittently while rock core drilling is in progress. The apparatus is carried to the work site by a three-legged mobile platform which also provides a 2-meter feed along the hole centerline, an off-hole movement of approximately .5 meters, an angular alignment of up to 20 deg. from gravity vertical, and other dexterity required in handling rods and samples. The technology can also be applied using other carriers which incorporate similar motion capabilities. The apparatus also includes storage racks for augers, rods, and ancillary devices such as the foot-plate that holds the down-hole tooling during rod changing operations.

Source record↗

On the dependence of solar flare X-ray spectral line intensity ratios of highly ionized sulfur, calcium, and iron on electron temperature, differential emission measure, and atomic physics

This paper focuses on what can be learned about the emission measure distribution and certain atomic physics parameters from spectral lines of highly ionized ions of sulfur, calcium, and iron that appear in solar flare spectra. The particular lines chosen for analysis allow the electron temperature to be determined independently of the assumption of ionization equilibrium. An attempt is made to find emission measure models based on selected functional dependences of emission measure on temperature that reproduce the observed temperatures deduced from spectral line ratios as well as the relative intensities of resonance lines of different elements.

Doschek, G. A.↗

Laboratory Studies in UV and EUV Solar Physics

The Ion Beam Experiment at the Center for Astrophysics is dedicated to the study of ion-electron collision processes of importance in solar physics. The analysis of measurements of Electron Impact Excitation (EIE) from the 3s3p(exp 3)P(exp o) metastable state to the 3s3p(exp 1)P state of Si(2+) was completed during the past year and a paper describing the results is available as a preprint. Our current program is directed at measuring absolute cross sections for dielectronic recombination (DR) and EIE in Si(3+), one of the primary ions used for probing the solar transition region. Our study of DR is particularly concerned with the effects of electric and magnetic fields on the recombination rates. Measurements of silicon ions with charge greater than n=2 have necessitated upgrading the experiment with a new ion source. The new source is also suitable for producing C(2+) beams to be used for measurements of EIE and DR for that system. The source is expected to be capable of producing beams of more highly charged systems as well.

Parkinson, W. H.↗

Electron-cyclotron maser radiation from a relativistic loss-cone distribution

A relativistic analysis of the electron-cyclotron maser instability in a loss-cone distribution is presented, extending the treatment of Lau and Chu (1983) to include the effects of finite k-perpendicular (as encountered in laboratory tandem-mirror devices with mean energies in excess of 50 keV). The results are presented in graphs, and it is found that the k-perpendicular effects are significant, so that emission perpendicular to the magnetic field is associated with most rapid growth of the instability. The persistence of the instability when the ratio of the plasma frequency to the electron-cyclotron frequency is less than 0.1 is demonstrated, and the factors which need to be accounted for in applying the results to actual mirror devices are indicated.

Pritchett, P. L.↗

EMIC-Wave Driven Electron Precipitation Observed by CALET on the International Space Station

We present an analysis of the relativistic electron precipitation (REP) event measured by the CALorimetric Electron Telescope (CALET) experiment on board the International Space Station during a relatively weak geomagnetic storm on 31 December 2016. CALET observations were compared with the measurements of the Van Allen Probes in the near-equatorial plane to investigate the global radiation belt dynamics and the REP drivers. The magnetically conjugate observations from these two missions demonstrate that the significant MeV precipitation directly detected by CALET in low-Earth orbit during a period of radiation belt depletion following the passage of a high-speed stream, was associated with dusk-side electromagnetic ion cyclotron (EMIC) waves. In addition, the combined wave, REP and trapped electron data suggest that the reported radiation belt depletion can be likely ascribed to the concomitant loss effects of EMIC wave scattering driving the atmospheric precipitation, as well as outward radial diffusion associated with magnetopause shadowing.

Radiation belts↗

Determination of minority-carrier lifetime and surface recombination velocity with high spacial resolution

Quantitative analysis of the electron beam induced current in conjunction with high-resolution scanning makes it possible to evaluate the minority-carrier lifetime three dimensionally in the bulk and the surface recombination velocity two dimensionally, with a high spacial resolution. The analysis is based on the concept of the effective excitation strength of the carriers which takes into consideration all possible recombination sources. Two-dimensional mapping of the surface recombination velocity of phosphorus-diffused silicon diodes is presented as well as a three-dimensional mapping of the changes in the minority-carrier lifetime in ion-implanted silicon.

Watanabe, M.↗

Thermal control of power supplies with electronic packaging techniques

The analysis, design, and development work to reduce the weight and size of a standard modular power supply with a 350 watt output was summarized. By integrating low cost commercial heat pipes in the redesign of this power supply, weight was reduced by 30% from that of the previous design. The temperature was also appreciably reduced, increasing the environmental capability of the unit. A demonstration unit with a 100 watt output and a 15 volt regulator module, plus simulated output modules, was built and tested to evaluate the thermal performance of the redesigned power supply.

Source record↗

Study of intermittent field hardware failure data in digital electronics

The collection and analysis of data concerning intermittent dailures in digital devices was performed using data from a computer design for shipboard usage. The failure data consisted of actual field failures classified by failure mechanisms and their likelihood of having been intermittent, potentially intermittent, or hard. Each class was studies with respect to computer operation in the ranges of 0 to 2,000 hours, 0 to 5, hours, and 0 to 10,000 hours. The study was done at the computer level as well as the microcircuit level. Results indicate that as age increases, the quasi-intermittent failure rate increases and the mean time to failure descreases.

Oneill, E. J.↗

Preparation and analysis of particulate metal deposits

Small particles and clusters of palladium were grown by deposition from the vapor phase under ultrahigh vacuum conditions. Amorphous and crystalline support films of Al2O3 and ultrathin amorphous carbon films were used as substrate materials. The growth of the metal deposit was monitored in situ by scanning transmission diffraction of energy-filtered 100 kV electrons and high resolution transmission electron microscopy (TEM) analysis was performed in a separate instrument. It was established by in situ TEM, however, that the transfer of specimens in this case did not unduly affect the size and distribution of deposit particles. It was found that the cleanness, stoichiometry, crystallinity and structural perfection of the support surface play an essential role in determining the crystalline perfection and structure of the particles. The smallest palladium clusters reproducibly prepared contained not more than six atoms but size determinations below 1 nm average particle diameter are very problematic with conventional TEM. Palladium particles grown on carbon supports feature an impurity-stabilized mosaic structure.

Poppa, H.↗

Thermal analysis of the ultraviolet imager camera and electronics

The Ultraviolet Imaging experiment has undergone design changes that necessiate updating the reduced thermal models (RTM's) for both the Camera and Electronics. In addition, there are several mission scenarios that need to be evaluated in terms of thermal response of the instruments. The impact of these design changes and mission scenarios on the thermal performance of the Camera and Electronics assemblies is discussed.

Dirks, Gregory J.↗

Frequency monitoring a LIDAR transmitter for pulse-by-pulse analysis and control

An electronic technique is described whereby the heterodyne mixing frequency of a pulsed LIDAR transmitter is displayed on a color-coded linear bar graph. The technique is of great utility for manually fine tuning the laser output frequency when the use of conventional frequency counters and spectrum analyzers is impractical in a rapidly firing system.

Esproles, Carlos↗

An Assessment of Molten Metal Detachment Hazards for Electron Beam Welding in the Space Environment: Analysis and Test Results

Conditions under which molten metal detachments might occur in a space welding environment are analyzed. A weld pool detachment parameter specifying conditions for pool detachment by impact is derived and corroborated by experimental evidence. Impact detachment for the pool is unlikely. Impact detachment for a drop of metal on the end of the weld wire may be possible under extreme conditions. Other potential causes of molten metal detachment considered, vaporization pressure forces and wire flickout from the pool, did not appear to present significant detachment threats.

Nunes, A. C., Jr.↗

Frequency-Domain Analysis of Diffusion-Cooled Hot-Electron Bolometer Mixers

A new theoretical model is introduced to describe heterodyne mixer conversion efficiency and noise (from thermal fluctuation effects) in diffusion-cooled superconducting hot-electron bolometers. The model takes into account the non-uniform internal electron temperature distribution generated by Wiedemann-Franz heat conduction, and accepts for input an arbitrary (analytical or experimental) superconducting resistance-versus- temperature curve. A non-linear large-signal solution is solved iteratively to calculate the temperature distribution, and a linear frequency-domain small-signal formulation is used to calculate conversion efficiency and noise. In the small-signal solution the device is discretized into segments, and matrix algebra is used to relate the heating modulation in the segments to temperature and resistance modulations. Matrix expressions are derived that allow single-sideband mixer conversion efficiency and coupled noise power to be directly calculated. The model accounts for self-heating and electrothermal feedback from the surrounding bias circuit.

Skalare, A.↗