Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “edge sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Results and Limits of Time-Division Multiplexing for the BICEP Array High-Frequency Receivers

Time-division multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high-frequency receivers, observing at 150 GHz and 220/270 GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard multichannel electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates time-division multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and cross talk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Finally, future experiments like CMB-S4 plan to use TES bolometers with time-division/SQUID-based readout for an even larger number of detectors.

47 OTHER INSTRUMENTATION↗

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

Development of a large-mass, low-threshold detector system with simultaneous measurements of athermal phonons and scintillation light

For this work, we have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to the difference in their scintillation light yield. While such systems with simultaneous phonon and light detection have been demonstrated earlier with smaller detectors, our system is designed to provide a large detector mass with high amplification for the limited scintillation light. Future work will focus on at least an order of magnitude improvement in the light collection efficiency by having a highly reflective detector housing and custom phonon mask design to maximize light collection by the silicon high-voltage detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flat optics for image differentiation

Image processing has become a critical technology in a variety of science and engineering disciplines. Although most image processing is performed digitally, optical analog processing has the advantages of being low-power and high-speed, but it requires a large volume. Here, we demonstrate flat optics for direct image differentiation, allowing us to significantly shrink the required optical system size. We first demonstrate how the differentiator can be combined with traditional imaging systems such as a commercial optical microscope and camera sensor for edge detection with a numerical aperture up to 0.32. We next demonstrate how the entire processing system can be realized as a monolithic compound flat optic by integrating the differentiator with a metalens. The compound nanophotonic system manifests the advantage of thin form factor as well as the ability to implement complex transfer functions, and could open new opportunities in applications such as biological imaging and computer vision.

36 MATERIALS SCIENCE↗

Gamma and Decay Energy Spectroscopy Measurements of Trinitite

We report gamma-ray spectroscopy measurements of trinitite samples and analogous samples obtained from detonation sites in Nevada and Semipalatinsk, as well as in situ measurements of topsoil at the Trinity site. We also report the first isotopic composition measurements of trinitite using the novel forensics technique of decay energy spectroscopy (DES) as a complement to traditional forensics techniques. Our gamma spectroscopy and DES measurements are compared to other published results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low Loss Superconducting Microstrip Development at Argonne National Lab

Low loss superconducting microstrip is an essential component in realizing 100 kilo-pixel multichroic cosmic microwave background detector arrays. In this paper, we have been developing a low loss microstrip by understanding and controlling the loss mechanisms. We present the fabrication of the superconducting microstrip, the loss measurements at a few GHz frequencies using half-wavelength resonators, and the loss measurements at 220 GHz frequencies with the superconducting microstrip coupled to slot antennas at one end and to TES detectors at the other end. Finally, the measured loss tangent of the microstrip made of sputtered Nb and SiOx is 1-2e-3.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Resolution Fission Fragment Spectroscopy with Superconducting Microcalorimeters

Sub-1 AMU mass determination is important for determining fission yields and neutron multiplicity, which are necessary inputs for fission models. Fission models can improve spent nuclear waste stream analysis and nuclear fuel burnup determination. Here, to achieve this goal, we have used superconducting microcalorimeter detectors to directly measure the energy of fission fragments from the spontaneous fission of 252 Cf. With a fiber coupled LED pulser setup we demonstrate that we can reach a relative energy resolution of 0.1% and better for photon pulses with energies above 60 MeV. This instrument, in conjunction with time-of-flight (TOF) measurement, would allow for sub-1 atomic mass unit (AMU) mass determination of fission fragments in a future beamline application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of Radio Frequency Interference and Potential Impacts on the CMB-S4 Cosmic Microwave Background Survey

CMB-S4 will map the cosmic microwave background to unprecedented precision, while simultaneously surveying the millimeter-wave time-domain sky, in order to advance our understanding of cosmology and the universe. CMB-S4 will observe from two sites, the South Pole and the Atacama Desert of Chile. A combination of small- and large-aperture telescopes with hundreds of thousands of polarization-sensitive detectors will observe in several frequency bands from 20-300 GHz, surveying more than 50% of the sky to arcminute resolution with unprecedented sensitivity. CMB-54 seeks to make a dramatic leap in sensitivity while observing across a broad range of largely unprotected spectrum which is increasingly being utilized for terrestrial and satellite transmissions. Fundamental aspects of CMB instrument technology leave them vulnerable to radio frequency interference (RFI) across a wide range of frequencies, including frequencies outside of their observing bands. Ground-based CMB instruments achieve their extraordinary sensitivities by deploying large focal planes of superconducting bolometers to extremely dry, high-altitude sites, with large fractional bandwidths, wide fields of view, and years of integration time. Suitable observing sites have historically offered significant protection from RFI, both naturally through their extremely remote locations as well as through restrictions on local emissions. Since the coupling mechanisms are complex, "safe" levels or frequencies of emission that would not interfere with CMB measurements cannot always be determined through straightforward calculations. We discuss models of interference for various types of RFI relevant to CMB-54, mitigation strategies, and the potential impacts on survey sensitivity.

Cosmic Microwave Background↗

Design and validation of a cold load for characterization of CMB-S4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three novel design features: (1) the ability to operate from the 1 K stage of a dilution refrigerator (DR), (2) a 3He gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150 GHz detector array previously deployed by the Spider experiment. Here, thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1 K stage. Additionally, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

47 OTHER INSTRUMENTATION↗

SMART Wind Turbine Rotor: Design and Field Test

The Wind Energy Technologies department at Sandia National Laboratories has developed and field tested a wind turbine rotor with integrated trailing-edge flaps designed for active control of rotor aerodynamics. The SMART Rotor project was funded by the Wind and Water Power Technologies Office of the U.S. Department of Energy (DOE) and was conducted to demonstrate active rotor control and evaluate simulation tools available for active control research. This report documents the design, fabrication, and testing of the SMART Rotor. This report begins with an overview of active control research at Sandia and the objectives of this project. The SMART blade, based on the DOE / SNL 9-meter CX-100 blade design, is then documented including all modifications necessary to integrate the trailing edge flaps, sensors incorporated into the system, and the fabrication processes that were utilized. Finally the test site and test campaign are described.

17 WIND ENERGY↗

Advanced Facility Design and AI/ML Enabled Safeguards to Establish Secure, Economical Recycling of Fast Reactor Fuels (Final Scientific/Technical Report)

The project, "Advanced Facility Design and AI/ML Enabled Safeguards to Establish Secure, Economical Recycling of Fast Reactor Fuels," represents a significant advancement in nuclear fuel recycling technology. It integrates cutting-edge multimodal sensor fusion, machine learning (ML), and digital twin (DT) technologies to address challenges in material safeguarding, process optimization, and regulatory compliance for pyroprocessing facilities. This research has significantly enhanced the understanding of pyrochemical fuel recycling processes by developing innovative tools and methodologies. The Multimodal Safeguards Monitoring Unit (MSMU) combines electroanalytical techniques, Raman spectroscopy, and differential thermal analysis (DTA) to enable high-fidelity, near-real-time material accountancy measurements. Machine learning techniques, such as Long Short-Term Memory (LSTM) autoencoders, are utilized to detect anomalies in material balances and sensor data, improving the reliability of safeguards monitoring. Additionally, digital twin technology has been established to provide real-time system-level monitoring and diagnostics, integrating physics-based models with sensor data to optimize process safety and efficiency.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗

Concept and analytical basis for revistas - A fast, flexible computer/graphic system for generating periodic satellite coverage patterns

The generation of satellite coverage patterns is facilitated by three basic strategies: use of a simplified physical model, permitting rapid closed-form calculation; separation of earth rotation and nodal precession from initial geometric analyses; and use of symmetries to construct traces of indefinite length by repetitive transposition of basic one-quadrant elements. The complete coverage patterns generated consist of a basic nadir trace plus a number of associated off-nadir traces, one for each sensor swath edge to be delineated. Each trace is generated by transposing one or two of the basic quadrant elements into a circle on a nonrotating earth model sphere, after which the circle is expanded into the actual 'helical' pattern by adding rotational displacements to the longitude coordinates. The procedure adapts to the important periodic coverage cases by direct insertion of the characteristic integers N and R (days and orbital revolutions, respectively, per coverage period).

King, J. C.↗

Simulation of landsat thematic mapper imagery using AVIRIS hyperspectral imagery

In this paper we present a methodology for simulating multispectral imagery (MSI) using hyperspectral imagery (HSI), and present a validation of the technique using one nearly coincident Landsat TM and AVIRIS data set. Generation of MSI from HSI supports several investigations including selection of multispectral sensor band edges, and engineering trade studies related to on-board or ground-based aggregation of HSI to simulate MSI. In addition, the utility of this technique as a potential procedure for monitoring calibration changes in spaceborne instrument is also addressed.

Kalman, Linda S.↗