Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diameter distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Design study of electron cyclotron resonance-ion plasma accelerator for heavy ion cancer therapy

Electron Cyclotron Resonance-Ion Plasma Accelerator (ECR-IPAC) device, which theoretically can accelerate multiple charged ions to several hundred MeV with short acceleration length, has been proposed. The acceleration mechanism is based on the combination of two physical principles, plasma electron ion adiabatic ejection (PLEIADE) and Gyromagnetic Autoresonance (GYRAC). In this study, we have designed the proof of principle machine ECR-IPAC device and simulated the electromagnetic field distribution generating in the resonance cavity. ECR-IPAC device consisted of three parts, ECR ion source section, GYRAC section, and PLEIADE section. ECR ion source section and PLEIADE section were designed using several multi-turn solenoid coils and sextupole magnets, and GYRAC section was designed using 10 turns coil. The structure of ECR-IPAC device was the cylindrical shape, and the total length was 1024 mm and the maximum diameter was 580 mm. The magnetic field distribution, which maintains the stable acceleration of plasma, was generated on the acceleration center axis throughout three sections. In addition, the electric field for efficient acceleration of electrons was generated in the resonance cavity by supplying microwave of 2.45 GHz.

43 PARTICLE ACCELERATORS↗

Selective-area growth of GaN nanowires on SiO{sub 2}-masked Si (111) substrates by molecular beam epitaxy

We analyze a method to selectively grow straight, vertical gallium nitride nanowires by plasma-assisted molecular beam epitaxy (MBE) at sites specified by a silicon oxide mask, which is thermally grown on silicon (111) substrates and patterned by electron-beam lithography and reactive-ion etching. The investigated method requires only one single molecular beam epitaxy MBE growth process, i.e., the SiO{sub 2} mask is formed on silicon instead of on a previously grown GaN or AlN buffer layer. We present a systematic and analytical study involving various mask patterns, characterization by scanning electron microscopy, transmission electron microscopy, and photoluminescence spectroscopy, as well as numerical simulations, to evaluate how the dimensions (window diameter and spacing) of the mask affect the distribution of the nanowires, their morphology, and alignment, as well as their photonic properties. Capabilities and limitations for this method of selective-area growth of nanowires have been identified. A window diameter less than 50 nm and a window spacing larger than 500 nm can provide single nanowire nucleation in nearly all mask windows. The results are consistent with a Ga diffusion length on the silicon dioxide surface in the order of approximately 1 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experiments and modeling of dilution jet flow fields

Experimental and analytical results of the mixing of single, double, and opposed rows of jets with an isothermal or variable-temperature main stream in a straight duct are presented. This study was performed to investigate flow and geometric variations typical of the complex, three-dimensional flow field in the dilution zone of gas-turbine-engine combustion chambers. The principal results, shown experimentally and analytically, were the following: (1) variations in orifice size and spacing can have a significant effect on the temperature profiles; (2) similar distributions can be obtained, independent of orifice diameter, if momentum-flux ratio and orifice spacing are coupled; (3) a first-order approximation of the mixing of jets with a variable-temperature main stream can be obtained by superimposing the main-stream and jets-in-an-isothermal-crossflow profiles; (4) the penetration of jets issuing mixing is slower and is asymmetric with respect to the jet centerplanes, which shift laterally with increasing downstream distance; (5) double rows of jets give temperature distributions similar to those from a single row of equally spaced, equal-area circular holes; (6) for opposed rows of jets, with the orifice centerlines in line, the optimum ratio of orifice spacing to duct height is one-half the optimum value for single-side injection at the same momentum-flux ratiol and (7) for opposed rows of jets, with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is twice the optimum value for single-side injection at the same momentum-flux ratio.

Holdeman, James D.↗

Soot particle sizing during high-pressure Diesel spray combustion via time-resolved laser-induced incandescence

Single-pulse time-resolved laser-induced incandescence (TiRe-LII) signal transients from soot particulates were acquired during unsteady high pressure Diesel combustion in a constant volume cell for typical top dead center conditions during a Diesel engine cycle. Measurements were performed for initial gas pressures between 1 and 3 MPa, injection pressures between 50 and 130 MPa and laser probe timings between 5 and 16 ms after start of fuel injection. In separate experiments and for the same cell operating conditions gas temperatures were deduced from spectrally resolved soot pyrometry measurements. Implementing the LII model of Kock et al. [Combust. Flame 147 (20006) 79-92] ensemble mean soot particle diameters were evaluated from least-squares fitting of theoretical cooling curves to experimental TiRe-LII signal transients. Since in the experiments the environmental gas temperature and the width of an assumed particle size distribution were not known, the effects of the initial choice of these parameters on retrieved particle diameters were investigated. It is shown that evaluated mean particle diameters are only slightly biased by the choice of typical size distribution widths and gas temperatures. For a fixed combustion phase mean particle diameters are not much affected by gas pressure, however they become smaller at high fuel injection pressure. At a mean chamber pressure of 1.39 MPa evaluated mean particle diameters increased by a factor of two for probe delays between 5 and 16 ms after start of injection irrespective of the choices of first-guess fitting variables, indicating a certain robustness of data analysis procedure. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-D-304-02: Magnetically Focused Proton Irradiation of Small Field Targets

Purpose: To investigate the use of magnetic focusing for small field proton irradiations. It is hypothesized that magnetic focusing will provide significant dose distribution benefits over standard collimated beams for fields less than 10 mm diameter. Methods: Magnets consisting of 24 segments of radiation hard samarium-cobalt adhered into hollow cylinders were designed and manufactured. Two focusing magnets were placed on a positioning track on our Gantry 1 treatment table. Proton beams with energies of 127 and 157 MeV, 15 and 30 mm modulation, and 8 mm initial diameters were delivered to a water tank using single-stage scattering. Depth dose distributions were measured using a PTW PR60020 diode detector and transverse profiles were measured with Gafchromic EBT3 film. Monte Carlo simulations were also performed - both for comparison with experimental data and to further explore the potential of magnetic focusing in silica. For example, beam spot areas (based on the 90% dose contour) were matched at Bragg depth between simulated 100 MeV collimated beams and simulated beams focused by two 400 T/m gradient magnets. Results: Preliminary experimental results show 23% higher peak to entrance dose ratios and flatter spread out Bragg peak plateaus for 8 mm focused beams compared with uncollimated beams. Monte Carlo simulations showed 21% larger peak to entrance ratios and a ∼9 fold more efficient dose to target delivery compared to spot-sized matched collimated beams. Our latest results will be presented. Conclusion: Our results suggest that rare earth focusing magnet assemblies could reduce skin dose and beam number while delivering dose to nominally spherical radiosurgery targets over a much shorter time compared to unfocused beams. Immediate clinical applications include those associated with proton radiosurgery and functional radiosurgery of the brain and spine, however expanded treatment sites can be also envisaged.

60 APPLIED LIFE SCIENCES↗

Measurements and Analysis of Oxygen Bubble Distributions in LiCl-KCl Molten Salt

Transparent system experimental studies have been performed to provide measurement and analysis of oxygen bubble distributions and mass transfer coefficients at different sparging rates ranging from 0.05 to 0.20 L/min in LiCl-KCl molten salt at 500 degrees C using a high-speed digital camera and an oxygen sensor. The results reveal that bubble sizes and rise velocities increased with an increase in oxygen sparging rate. The bubbles observed were ellipsoidal in shape, and an equivalent diameter based on the ellipsoid volume was calculated. The average equivalent bubble diameters at 500 degrees C and these oxygen sparging rates range from 2.63 to 4.07 mm. Results show that the bubble equivalent diameters at each respective sparging rate are normally distributed. A Fanning friction factor correlation was produced to predict a bubble’s rise velocity based on its equivalent diameter. The oxygen mass transfer coefficients for four sparging rates were calculated using the oxygenation model. These calculated values were within the order of magnitude of 10-2 cm/sec and followed a decreasing trend corresponding to an increasing bubble size and sparging rate. The diffusivities were calculated based on two different types of mechanisms, one based on physics of the bubbles and the other on systematic properties. The results reveal that diffusivity values calculated from bubble physics are 1.65 to 8.40 x 10-5 cm2/sec, which are within the range suggested by literature for gases in liquids of a similar viscosity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of assumptions made by Hygroscopic Tandem Differential Mobility Analyzer inversion routines

The Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA) measures the hygroscopicity of atmospheric particles, and many atmospheric processes that change this hygroscopicity also change the atmospheric size distribution. Two assumptions made during H-TDMA inversion create spurious hygroscopic trends as a function of the changing inlet size distribution. These two assumptions—that the particles exiting the first Differential Mobility Analyzer (DMA1) are singly charged and that the inlet size distribution has a slope of zero (flat)— generate Multi-Charge Dispersion (MCD) bias and Slope bias, respectively. First, we use a model, named TAO, to show that the inlet size distribution could theoretically change the measured ammonium sulfate hygroscopicity by 10%–20% as a function of diameter or experimental time with no change in relative humidity. Secondly, we show experimentally that aerosol emitted from the flaming combustion of grass creates MCD bias. Here, in this experiment, we measure the CPC response of the first three charges and invert these responses using a new routine named Junior. Junior's inversion of each charge shows that one growth factor distribution describes all measured diameters (no growth dependence on diameter). As in the modeling study above, previous publications of this aerosol system, using traditional inversion assumptions, report a decrease in hygroscopicity as DMA1 diameter increases. Unlike traditional inversions, Junior's inversion does not assume the particles are singly charged nor does it make the flat inlet size distribution assumption. Instead, both the inlet size distribution and each charge's CPC response are measured quantities. Thus, the discrepancy between our inversion results and previous publications is likely due to the traditional inversion routine assumptions. This underscores the importance for accounting for Slope and MCD bias during inversions. Experimental results should be carefully analyzed when reporting hygroscopic trends with respect to diameter or experimental time when using the traditional inversion assumptions.

42 ENGINEERING↗

Space station ventilation study

A ventilation system design and selection method which is applicable to any manned vehicle were developed. The method was used to generate design options for the NASA 33-foot diameter space station, all of which meet the ventilation system design requirements. System characteristics such as weight, volume, and power were normalized to dollar costs for each option. Total system costs for the various options ranged from a worst case $8 million to a group of four which were all approximately $2 million. A system design was then chosen from the $2 million group and is presented in detail. A ventilation system layout was designed for the MSFC space station mockup which provided comfortable, efficient ventilation of the mockup. A conditioned air distribution system design for the 14-foot diameter modular space station, using the same techniques, is also presented. The tradeoff study resulted in the selection of a system which costs $1.9 million, as compared to the alternate configuration which would have cost $2.6 million.

Colombo, G. V.↗

Computational Icing Risk Analysis of the D8 "Double Bubble" Aircraft

A computational icing risk analysis utilizing LEWICE3D was performed for the D8 Double Bubble aircraft. A variety of discrete drop sizes spanning the Appendix C and O regimes were simulated. For computational efficiency a 50-bin global discretization was produced and projected onto the distributions of interest, eliminating redundant simulations. The trajectory and impingement characteristics for discrete drop diameters were analyzed to help understand the behavior of the water drops in the presence of a complex flow field. The collection efficiency results for the discrete drop diameters were then weighted by their contributions to the total water content of six different continuous distributions and subsequently superposed to approximate these curves. Results indicate that significant variation in impingement exists as a function of drop diameter for complex wing body geometries, and that current discretization practices may be insufficient to accurately predict water collection on certain regions of the aircraft. Results also indicate that the Appendix O distributions, specifically those with considerable water content at large drops, generates water collection patterns that are markedly different from distributions representative of Appendix C.

icing↗

Computational Icing Risk Analysis of the D8 "Double Bubble" Aircraft

A computational icing risk analysis utilizing LEWICE3D was performed for the D8 Double Bubble aircraft. A variety of discrete drop sizes spanning the Appendix C and O regimes were simulated. For computational efficiency a 50-bin global discretization was produced and projected onto the distributions of interest, eliminating redundant simulations. The trajectory and impingement characteristics for discrete drop diameters were analyzed to help understand the behavior of the water drops in the presence of a complex flow field. The collection efficiency results for the discrete drop diameters were then weighted by their contributions to the total water content of six different continuous distributions and subsequently superposed to approximate these curves. Results indicate that significant variation in impingement exists as a function of drop diameter for complex wing body geometries, and that current discretization practices may be insufficient to accurately predict water collection on certain regions of the aircraft. Results also indicate that the Appendix O distributions, specifically those with considerable water content at large drops, generates water collection patterns that are markedly different from distributions representative of Appendix C.

Porter, Christopher E.↗

Raindrop Size Distribution Measurements in Tropical Cyclones

Characteristics of the raindrop size distribution in seven tropical cyclones have been studied through impact-type disdrometer measurements at three different sites during the 2004-06 Atlantic hurricane seasons. One of the cyclones has been observed at two different sites. High concentrations of small and/or midsize drops were observed in the presence or absence of large drops. Even in the presence of large drops, the maximum drop diameter rarely exceeded 4 mm. These characteristics of raindrop size distribution were observed in all stages of tropical cyclones, unless the storm was in the extratropical stage where the tropical cyclone and a midlatitude frontal system had merged. The presence of relatively high concentrations of large drops in extratropical cyclones resembled the size distribution in continental thunderstorms. The integral rain parameters of drop concentration, liquid water content, and rain rate at fixed reflectivity were therefore lower in extratropical cyclones than in tropical cyclones. In tropical cyclones, at a disdrometercalculated reflectivity of 40 dBZ, the number concentration was 700 plus or minus 100 drops m(sup -3), while the liquid water content and rain rate were 0.90 plus or minus 0.05 g m(sup -3) and 18.5 plus or minus 0.5 mm h(sup -1), respectively. The mean mass diameter, on the other hand, was 1.67 plus or minus 0.3 mm. The comparison of raindrop size distributions between Atlantic tropical cyclones and storms that occurred in the central tropical Pacific island of Roi-Namur revealed that the number density is slightly shifted toward smaller drops, resulting in higher-integral rain parameters and lower mean mass and maximum drop diameters at the latter site. Considering parameterization of the raindrop size distribution in tropical cyclones, characteristics of the normalized gamma distribution parameters were examined with respect to reflectivity. The mean mass diameter increased rapidly with reflectivity, while the normalized intercept parameter had an increasing trend with reflectivity. The shape parameter, on the other hand, decreased in a reflectivity range from 10 to 20 dBZ and remained steady at higher reflectivities. Considering the repeatability of the characteristics of the raindrop size distribution, a second impact disdrometer that was located 5.3 km away from the primary site in Wallops Island, Virginia, had similar size spectra in selected tropical cyclones.

Tokay, Ali↗

Investigation Into the Optimum Beam Shape and Fluence for Selective Ablation of Dental Calculus at lambda = 400 nm

A frequency-doubled Ti:sapphire laser is shown to selectively ablate dental calculus. The optimal transverse shape of the laser beam, including its variability under water-cooling, is determined for selective ablation of dental calculus. Intensity profiles under various water-cooling conditions were optically observed. The 400-nm laser was coupled into a multimode optical fiber using an f = 2.5-cm lens and light-shaping diffuser. Water-cooling was supplied coaxially around the fiber. Five human tooth samples (four with calculus and one pristine) were irradiated perpendicular to the tooth surface while the tooth was moved back and forth at 0.3 mm/second, varying between 20 and 180 iterations. The teeth were imaged before and after irradiation using light microscopy with a flashing blue light-emitting diode (LED). An environmental scanning electron microscope imaged each tooth after irradiation. High-order super-Gaussian intensity profiles are observed at the output of a fiber coiled around a 4-in. diameter drum. Super-Gaussian beams have a morehomogenous fluence distribution than Gaussian beams and have a higher energy efficiency for selective ablation. Coaxial water-cooling does not noticeably distort the intensity distribution within 1 mm from the optical fiber. In contrast, lasers focused to a Gaussian cross section (<=50-mm diameter) without fiber propagation and cooled by a water spray are heavily distorted and may lead to variable ablation. Calculus is preferentially ablated at high fluences (>= 2 J/cm^2); below this fluence, stalling occurs because of photo-bleaching of the calculus. Healthy dental hard tissue is not removed at fluences <=3 J/cm^2. Supplying laser light to a tooth using an optical fiber with coaxial water-cooling is determined to be the most appropriate method when selectively removing calculus with a frequency-doubled Ti:sapphire laser. Fluences over 2 J/cm^2 are required to remove calculus efficiently since photo-bleaching stalls calculus removal below that value.

calculus removal↗

Magnetic flux in modeled magnetic clouds at 1 AU and some specific comparisons to associated photospheric flux

In order to better understand the solar origins of magnetic clouds, statistical distributions of the estimated axial magnetic flux of 30 magnetic clouds at 1 AU, separated according to their occurrence during the solar cycle, were obtained and a comparison was made of the magnetic flux of a magnetic cloud to the aggregate flux of apparently associated photospheric magnetic flux tubes, for some specific cases. The 30 magnetic clouds comprise 12 cases from WIND, and the remainder from IMP-8, earlier IMPs, the International Sun-Earth Explorer (ISEE) 3 and HELIOS. The total magnetic flux along the cloud axis was estimated using a constant alpha, cylindrical, force-free flux rope model to determine cloud diameter and axial magentic field strength. The distribution of magentic fluxes for the 30 clouds is shown to be in the form of a skewed Gaussian.

Lepping, R. P.↗

aafsmps (b1)

The scanning mobility particle sizer (SMPS) is a particle size spectrometer that measures the aerosol number size distribution by sizing particles based on their electrical mobility diameter using a differential mobility analyzer (DMA) and by counting particles using a condensation particle counter (CPC). It measures aerosol concentration and aerosol particle size distribution in the Aitken mode range.

54 ENVIRONMENTAL SCIENCES↗

Microcrater investigations on Surveyor 3 material

Screws 9 and 23 from Surveyor 3 were examined with a scanning electron microscope for micrometeorite impact features. Six craters on one of the screws appear to be low velocity impact craters, and a flux for about 0.12 sq cm was calculated to be 0.005/sq m/sec for particle diameter or = 1 micron. Two interpretations are considered: (1) The impacts were produced by interplanetary particles and the flux indicates that deviation from the normal distribution exists only for particles below 1 micron in diameter. (2) Most of the craters were produced by secondary lunar debris, and the flux represents the upper limit for interplanetary particles.

Schneider, E. J.↗

Measuring Multicomponent Adsorption of Tracer Gases on Natural Zeolites

A natural clinoptilolite sample near the Nevada National Security Site was obtained to study adsorption and retardation on gas transport. Of interest is understanding the competition for adsorption sites that may reduce tracer gas adsorption relative to single-component measurements, which may be affected by the multi-scale pore structure of clinoptilolite. Clinoptilolite has three distinct domains of pore size distributions ranging from nanometers to micrometers: micropores with 0.4–0.7 nm diameters, measured on powders by CO2 adsorption at 273 K, representing the zeolite cages; mesopores with 4–200 nm diameters, observed using liquid nitrogen adsorption at 77 K; and macropores with 300–1000 nm diameters, measured by mercury injection on rock chips (~ 100 mesh), likely representing the microfractures. These pore size distributions are consistent with X-ray computed tomography (CT) and focused ion beam scanning electron microscope (FIB-SEM) images, which are used to construct the three-dimensional (3D) pore network to be used in future gas transport modeling. To quantify tracer gas adsorption in this multi-scale pore structure and multicomponent gas species environment, natural zeolite samples initially in equilibrium in air were exposed to a mixture of tracer gases. As the tracer gases diffuse and adsorb in the sample, the remaining tracer gases outside the sample fractionate. Using a quadrupole mass spectrometer to quantify this fractionation, the degree of adsorption of tracer gases in the multicomponent gas environment and multi-scale pore structure is assessed. The major finding is that Kr reaches equilibrium much faster than Xe in the presence of ambient air, which leads to more Kr uptake than Xe over limited exposure periods. When the clinoptilolite chips were exposed to humid air, the adsorption capability decreases significantly for both Xe and Kr with relative humidity (RH) as low as 3%. Both Xe and Kr reaches equilibrium faster at higher RH. The different, unexpected, adsorption behavior for Xe and Kr is due to their kinetic diameters similar to the micropores in clinoptilolite which makes it harder for Xe to access compared to Kr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Remote Sensing of Wind Fields and Aerosol Distribution with Airborne Scanning Doppler Lidar

The coherent Doppler laser radar (lidar), when operated from an airborne platform, is a unique tool for the study of atmospheric and surface processes and features. This is especially true for scientific objectives requiring measurements in optically-clear air, where other remote sensing technologies such as Doppler radar are typically at a disadvantage. The atmospheric lidar remote sensing groups of several US institutions, led by Marshall Space Flight Center, have developed an airborne coherent Doppler lidar capable of mapping the wind field and aerosol structure in three dimensions. The instrument consists of an eye-safe approx. 1 Joule/pulse lidar transceiver, telescope, scanner, inertial measurement unit, and flight computer system to orchestrate all subsystem functions and tasks. The scanner is capable of directing the expanded lidar beam in a variety of ways, in order to extract vertically-resolved wind fields. Horizontal resolution is approx. 1 km; vertical resolution is even finer. Winds are obtained by measuring backscattered, Doppler-shifted laser radiation from naturally-occurring aerosol particles (of order 1 micron diameter). Measurement coverage depends on aerosol spatial distribution and composition. Velocity accuracy has been verified to be approx. 1 meter per second. A variety of applications have been demonstrated during the three flight campaigns conducted during 1995-1998. Examples will be shown during the presentation. In 1995, boundary layer winds over the ocean were mapped with unprecedented resolution. In 1996, unique measurements were made of. flow over the complex terrain of the Aleutian Islands; interaction of the marine boundary layer jet with the California coastal mountain range; a weak dry line in Texas - New Mexico; the angular dependence of sea surface scattering; and in-flight radiometric calibration using the surface of White Sands National Monument. In 1998, the first measurements of eyewall and boundary layer winds within a hurricane were made with the airborne Doppler lidar. Potential applications and plans for improvement will also be described.

Rothermel, Jeffry↗