Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

The effect of blood viscosity on shear‐induced hemolysis using a magnetically levitated shearing device

Abstract Introduction Blood contacting medical devices, including rotary blood pumps, can cause shear‐induced blood damage that may lead to adverse effects in patients. Due in part to an inadequate understanding of how cell‐scale fluid mechanics impact red blood cell membrane deformation and damage, there is currently not a uniformly accepted engineering model for predicting blood damage caused by complex flow fields within ventricular assist devices (VADs). Methods We empirically investigated hemolysis in a magnetically levitated axial Couette flow device typical of a rotary VAD. The device is able to accurately control the shear rate and exposure time experienced by blood and to minimize the effects of other uncharacterized stresses. Using this device, we explored the effects of both hematocrit and plasma viscosity on shear‐induced hemolysis to characterize blood damage based on the viscosity‐independent shear rate, rather than on shear stress. Results Over a shear rate range of 20 000 – 80 000 1/s, the Index of Hemolysis (IH) was found to be dependent upon and well‐predicted by the shear rate alone. IH was independent of hematocrit, bulk viscosity, or the suspension media viscosity and less correlated to shear stress (MSE = 0.46–0.75) than to shear rate (MSE = 0.06–0.09). Conclusion This study recommends that future investigations of shear‐induced blood damage report findings with respect to the viscosity‐neutral term of shear rate, in addition to the bulk whole blood viscosity measured at an appropriate shear rate relevant to the flow conditions of the device.

Krisher, James A.↗

Comparative operando XPS studies of quasi-Fermi level splitting and open-circuit voltage in CZTSe/CdS and CIGS/CdS junctions and device structures

This contribution describes operando x-ray photoelectron spectroscopy (opXPS) studies of Cu(In,Ga)Se 2 (CIGS) and Cu 2 ZnSnSe 4 (CZTSe) absorber layers and device structures. X-ray-excited valence-band and core-level spectra were acquired on bare absorber surfaces and after CdS and ZnO:Al depositions in standard absorber/CdS/ZnO/ZnO:Al device stacks. OpXPS data sets were acquired at various x-ray fluxes, with and without white-light illumination. From these measurements, quasi-Fermi level splitting (ΔE F ) values in the absorber/CdS junctions were measured directly as a function of excitation conditions. For both CIGS and CZTSe, results show that ..delta..EF proportional to the full open-circuit voltage (V OC ) of the completed devices is present after the deposition of the CdS layer - i.e., E F = qV OC - demonstrating that the so-called V OC deficit in CZTSe solar cells is also present at this stage of processing. The authors find that photoexcitation due to x-rays or stray visible light during XPS or similar measurements can produce measurable photovoltages in materials, absorber/CdS junctions, and finished devices. In situ current density versus voltage measurements on a typical CIGS device reveal that x-ray-induced photoexcitation associated with typical XPS measurement conditions is equivalent to ~3 x 10 -3 suns, which in this study produced V OC = 440 mV. These findings demonstrate that accounting for photoexcitation conditions during XPS or similar measurements can improve band-offset determinations and produce more reliable values for the junction built-in voltage. The implications of the study findings on the CZTSe V OC deficit and device performance are discussed.

36 MATERIALS SCIENCE↗

Structural breakdown in high power GaN-on-GaN p-n diode devices stressed to failure

The morphology of GaN-on-GaN vertical p-i-n diode devices after reverse-bias electrical stressing to breakdown has been investigated. All failed devices had irreversible structural damage, showing large surface craters that were ∼15–35 μm deep with lengthy surface cracks. Cross-sectional electron micrographs of failed devices showed substantial concentrations of threading dislocations around the cracks and near the crater surfaces. Progressive ion-milling across damaged devices revealed high densities of threading dislocations and the presence of voids beneath the surface cracks; these features were not observed in any unstressed devices. These results should serve as a useful reference for future reliability studies of vertical high-power GaN devices.

Peri, Prudhvi (ORCID:000000022338441X)↗

Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176

The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, e.g., accounting for temperature and pressure, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices is often overlooked. These devices also increase skin dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased skin dose compared to the “tennis racket” style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations the authors make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of surface dose and attenuation and how to report these values. For the vendors, an appeal is made to work together to provide accurate couch top models in planning systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-16: A Comparison of Expected Dwell Times and Dose Variations for NAMD Patients Treated with An Episcleral Brachytherapy Device

Purpose: To evaluate the variations in dwell times and doses expected when using an episcleral brachytherapy device for treatment of neovascular agerelated macular degeneration (n-AMD) based on accurate imaging modalities Methods: Data from 40 eyes from 40 subjects with known n- AMD acquired through the Distance of Choroid Study (DOCS) conducted at Moorfields Eye Hospital was used to determine the target depth; the distance from the outer scleral surface of the eye, through the choroid, to the apex of the choroidal neovascularization (CNV). Each subject underwent, in triplicate, enhanced-depth Spectral Domain Optical Coherence Tomography (SD-OCT), Swept Source Optical Coherence Tomography, (SS-OCT) and Ocular Ultrasound (O-US). These data are the most comprehensive and accurate measurements of the dimensions of the CNV and adjacent layers of the eye for this cohort of patients. During treatment of n-AMD, patients receive a dose of 24Gy to the apex at the target depth. Using the percentage depth dose for a Sr-90 episcleral brachytherapy device, dwell times and doses to the apex were computed to determine the expected variations. Results: The mean target depth and the 95% confidence interval (CI) determined by combining O-US with SD-OCT were 1326 (956,1696)µm and with SS-OCT were 1332 (970,1693)µm. The calculated corresponding mean dwell times and 95% (CI) were 334 (223,445)s and 335 (226,445)s for SD-OCT and SS-OCT determined depths, respectively. The corresponding mean apex dose and 95% (CI) were 24 (35.9,18.0)Gy (SD-OCT) and 24 (35.6,18.1)Gy (SS-OCT). Conclusion: For episcleral brachytherapy treatment of n-AMD, using a patient population average target depth for treatment planning is inadequate, resulting in dose variations of a factor of approximately two over the 95% CI and larger variations for a nontrivial segment of the population. Each patient should have individualized imaging studies to determine the target depth for use in the dwell time calculation. Study was sponsored by Salutaris Medical Devices, Ltd., a subsidiary of Salutaris Medical Devices, Inc. Hamilton and Marsteller are founders of Salutaris Medical Devices, Inc. Drew, McGovern and Vitali are minor equity holders in Salutaris Medical Devices, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-T-526: A Comparative Study On Gating Efficiency of Varian RPM Device and Calypso System

Purpose: In general, the linear accelerator is gated using respiratory signal obtained by way of external sensors to account for the breathing motion during radiotherapy. One of the commonly used gating devices is the Varian RPM device. Calypso system that uses electromagnetic tracking of implanted or surface transponders could also be used for gating. The aim of this study is to compare the gating efficiency of RPM device and the calypso system by phantom studies. Methods: An ArcCheck insert was used as the phantom with a Gafchromic film placed in its holder. The ArcCheck insert was placed on a Motion Sim platform and moved in the longitudinal direction simulating a respiratory motion with a period of 5 seconds and amplitude of ±6mm. The Gafchromic film was exposed to a 2 × 2cm{sup 2} field, i) with the phantom static, ii) phantom moving but ungated iii) gated with gating window of 2mm and 3mm. This was repeated with Calypso system using surface transponders with the same gating window. The Gafchromic films were read with an EPSON 11000 flatbed scanner and analysed with ‘Medphysto’ software. Results: The full width at half maximum (FWHM) as measured with film at the level of the film holder was 1.65cm when the phantom was static. FWHM measured with phantom moving and without gating was 1.16 cm and penumbra was 7 mm (80–20%) on both sides. When the beam was gated with 2 mm gating window the FWHM was 1.8 cm with RPM device and 1.9 cm with Calypso. Similarly, when the beam was gated with 3 mm window, the FWHM was 1.9cm with RPM device and 2cm with Calypso. Conclusion: This work suggests that the gating efficiency of RPM device is better than that of the Calypso with surface transponder, with reference to the latency in gating.

60 APPLIED LIFE SCIENCES↗

MO-A-BRC-00: TG167: Clinical Recommendations for Innovative Brachytherapy Devices and Applicators

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.

60 APPLIED LIFE SCIENCES↗

MODAL TRACKING of A Structural Device: A Subspace Identification Approach

Mechanical devices operating in an environment contaminated by noise, uncertainties, and extraneous disturbances lead to low signal-to-noise-ratios creating an extremely challenging processing problem. To detect/classify a device subsystem from noisy data, it is necessary to identify unique signatures or particular features. An obvious feature would be resonant (modal) frequencies emitted during its normal operation. In this report, we discuss a model-based approach to incorporate these physical features into a dynamic structure that can be used for such an identification. The approach we take after pre-processing the raw vibration data and removing any extraneous disturbances is to obtain a representation of the structurally unknown device along with its subsystems that capture these salient features. One approach is to recognize that unique modal frequencies (sinusoidal lines) appear in the estimated power spectrum that are solely characteristic of the device under investigation. Therefore, the objective of this effort is based on constructing a black box model of the device that captures these physical features that can be exploited to “diagnose” whether or not the particular device subsystem (track/detect/classify) is operating normally from noisy vibrational data. Here we discuss the application of a modern system identification approach based on stochastic subspace realization techniques capable of both (1) identifying the underlying black-box structure thereby enabling the extraction of structural modes that can be used for analysis and modal tracking as well as (2) indicators of condition and possible changes from normal operation.

42 ENGINEERING↗

The Determination of Radiation Hardness of Semiconductor Materials and Devices with Ion Beams

lon accelerator based techniques provide unique tools to gain insight into the phenomena underlying the formation of defects induced by energetic particles in semiconductor materials and their effects on the electronic features of the device. In recognition of the potential of these techniques, with the aim of enhancing the understanding of the mechanisms underlying the degradation of the performances of semiconductor devices induced by ionizing radiation, the IAEA established a Research Project, coordinated by the Physics Section (CRP F11016) entitled "Utilization of ion accelerators for studying and modelling of radiation induced defects in semiconductors and insulators" at the end of 2011. The objective of this IAEA Coordinated Research Project (CRP) was to enhance the capabilities of the interested Member States by facilitating their collective efforts to use accelerator-based ion irradiation of electronic materials in conjunction with available advanced characterization techniques to gain a deeper understanding of how different types of radiation influences the electronic properties of materials and devices, leading to an improved radiation hardness. A dynamic and productive research was stimulated by this CRP among collaborating partners, resulting in publications in scientific journals [CRP2016], educational and scientific software packages [W8, Forneris2014], and a number of collaborations among the participating research groups. Two of the most significant outcomes of this project are i) the experimental protocol, which rationalizes the use of the many existing characterization techniques adopted to investigate radiation effects in semiconductor devices and ii) the relevant theoretical approach to interpret the experimental data [Vittone2016 and references therein]. This publication integrates output of research articles published by the partners of the CRP and is aimed to provide an exhaustive description of the experimental protocol, the theoretical model with the relevant limits of application, the data analysis procedure, and the physical observables which can be effectively measured and which can be used for assessment of the radiation hardness of semiconductor devices. The intended audience of this report includes all those professionals and technologists working in ion beam functional analysis of semiconductor materials, solid-state physicists and engineers involved in the design of electronic devices working in radiation harsh environments.

36 MATERIALS SCIENCE↗

Categorizing An Explosive Device by its Nuclear Signature (Rev. 1)

This report documents a study to eliminate ambiguity in identifying a very low-yield nuclear detonation in the early stages of the response to such an event. The ambiguity arises from the very similar explosive and radiation effects produced by three categories of explosive devices: An explosively driven radiological dispersal device (RDD) or an accidental explosion in which radiologic material is scattered by chemical explosives. A failed nuclear device in which nuclear material, such as uranium or plutonium, has been scattered by conventional explosives. A nuclear device that, in addition to scattering nuclear material, produced a very low-yield from nuclear fission. The study found that the properties of fission products provide a ready solution to the problem. The radiation dose rate from fission products that were produced in a nearly instantaneous “fission event” decreases extremely rapidly over the first eight hours after that event, whereas nuclear materials and common radiological materials produce an essentially constant dose rate. This contrast provides an unequivocal fission product signature. The measurements required to utilize this signature can be made by first responders with radiation detectors already in the field, on time scales of an hour, although later confirmation using more capable detectors, including spectroscopic capability, is advised. The process of categorizing an explosives-related incident, both pre- and post-detonation, can be represented as a Decision Tree. The Decision Tree illustrates the use of already-fielded radiation detectors to categorize incidents as likely to involve only conventional explosives, an explosively driven RDD, or a nuclear device. The identification of an explosion as a fission event is extremely important to evacuation planners. It has been shown that delayed evacuation after sheltering in place for up to 24 hours after a fission event has the potential to reduce radiation exposure to the affected public and responders by a factor of ten. Traditional evidence collection after a nuclear detonation is likely to be similarly delayed, as the value and urgency of collection efforts must be weighed against radiation and other hazardous exposure of the collectors. The evidence that survives the immediate effects of a nuclear detonation will, in many cases, still be available for collection once radiation levels have diminished to acceptable levels. Certain classes of evidence, notably information stored on digital media, may significantly degrade from exposure to post-detonation radiation fields. Technical nuclear forensics collections will be performed in all events with nuclear yield. Modification of the high-yield collection strategy may be necessary for a very low-yield device.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Countering Weapons of Mass Destruction Office (CWMD) Data Categorization Study: Chemical, Biological, Radiological, and Nuclear (CBRN) Detection Device Data

Pacific Northwest National Laboratory (PNNL) seeks to address critical questions related to chemical, biological, radiological, and nuclear (CBRN) detection devices. This research aims to enhance the security and understanding of these devices by investigating various aspects of their identification, communication, and functionality. The primary focus is on network security, malware detection, device identification, and intelligence gathering. CBRN data can be categorized in various ways depending on the purpose of CBRN detection devices and the specific context of the applications for analysis. Criteria that can be used to assist in this effort include but are not limited to data type, data protocol, source/destination, application, time, security, and content. This study will inform additional paths for data classification, data profiling, data mapping, and data modeling. This will help the Countering Weapons of Mass Destruction Office (CWMD) better understand their data and make informed decisions based on the insights gained from this study and their application. The CBRN Data Categorization study will include the identification of 5–10 different CBRN detection devices with unique characteristics for assessing and analyzing the data that is being produced by and transmitted from these devices.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Heavy-Duty Hydrogen Station Equipment Performance Device (HD HyStEP) Specifications and Design Considerations

The original Hydrogen Station Equipment Performance (HyStEP) device was commissioned in 2015 and was critical for the rapid validation of light-duty (LD) hydrogen fueling stations. As applications for hydrogen as a heavy-duty (HD) transportation fuel continue to grow, new heavy-duty stations are being developed to fuel these vehicles that require larger onboard storage tank systems to meet HD transportation demands and drive cycles. The differences in size and geometry from LD vehicles have driven the creation of new hydrogen fueling protocols that will enable safe and economical fueling of HD vehicles. With the new requirements that are set out in HD fueling protocols like SAE J601-5, a new HyStEP-like device is needed to evaluate the capabilities of high-flow hydrogen stations to fuel HD vehicles to the new protocol standard. To create a heavy-duty HyStEP (HD HyStEP) device, an effort has been undertaken to evaluate the requirements that would form the basis for the design of a successful HD HyStEP device. The primary design goal of this HD HyStEP device is its capability of following a test methodology similar to what is outlined in CSA HGV 4.3, which guides the validation of LD fueling dispensers but with adjustments to verify adherence to the HD fueling protocols (SAE J2601-5) for 70 MPa and 35 MPa pressure class vehicles rather than the LD fueling protocols (SAE J2601). The design presented here aims to provide information that enables the creation of an HD HyStEP device that achieves the primary design goal while being informed by the years of experience from the current HyStEP operators.

08 HYDROGEN↗

Competing Easy-Axis Anisotropies Impacting Magnetic Tunnel Junction-Based Molecular Spintronics Devices (MTJMSDs)

Molecular spintronics devices (MSDs) attempt to harness molecules’ quantum state, size, and configurable attributes for application in computer devices—a quest that began more than 70 years ago. In the vast number of theoretical studies and limited experimental attempts, MSDs have been found to be suitable for application in memory devices and futuristic quantum computers. MSDs have recently also exhibited intriguing spin photovoltaic-like phenomena, signaling their potential application in cost-effective and novel solar cell technologies. The molecular spintronics field’s major challenge is the lack of mass-fabrication methods producing robust magnetic molecule connections with magnetic electrodes of different anisotropies. Another main challenge is the limitations of conventional theoretical methods for understanding experimental results and designing new devices. Magnetic tunnel junction-based molecular spintronics devices (MTJMSDs) are designed by covalently connecting paramagnetic molecules across an insulating tunneling barrier. The insulating tunneling barrier serves as a mechanical spacer between two ferromagnetic (FM) electrodes of tailorable magnetic anisotropies to allow molecules to undergo many intriguing phenomena. Our experimental studies showed that the paramagnetic molecules could produce strong antiferromagnetic coupling between two FM electrodes, leading to a dramatic large-scale impact on the magnetic electrode itself. Recently, we showed that the Monte Carlo Simulation (MCS) was effective in providing plausible insights into the observation of unusual magnetic domains based on the role of single easy-axis magnetic anisotropy. Here, we experimentally show that the response of a paramagnetic molecule is dramatically different when connected to FM electrodes of different easy-axis anisotropies. Motivated by our experimental studies, here, we report on an MCS study investigating the impact of the simultaneous presence of two easy-axis anisotropies on MTJMSD equilibrium properties. In-plane easy-axis anisotropy produced multiple magnetic phases of opposite spins. The multiple magnetic phases vanished at higher thermal energy, but the MTJMSD still maintained a higher magnetic moment because of anisotropy. The out-of-plane easy-axis anisotropy caused a dominant magnetic phase in the FM electrode rather than multiple magnetic phases. The simultaneous application of equal-magnitude in-plane and out-of-plane easy-axis anisotropies on the same electrode negated the anisotropy effect. Our experimental and MCS study provides insights for designing and understanding new spintronics-based devices.

42 ENGINEERING↗

Use of a 360-Degree Underwater Camera to Characterize Artificial Reef and Fish Aggregating Effects around Marine Energy Devices

Marine energy devices must be attached to the seafloor by their foundations, pilings, or anchors, and will have other parts in the water column like the devices themselves, mooring lines, and power export cables running along the seafloor. The installation and presence of these artificial structures will create physical changes that can disrupt or create new habitats, and potentially alter the behavior of mobile organisms such as fish around a device by attracting them to these new artificial reefs and fish aggregating devices. In this study, we tested a new approach for monitoring fish activity around a marine energy device anchor: a 360-degree underwater camera to keep the target (a wave energy converter’s anchor) in the field of view of the camera. The camera was deployed in three configurations (hand-held, tripod, video lander) at sites with different hydrodynamics and underwater visibilities. The video lander was the best configuration: very stable, versatile, and easy to handle. The 360-degree field of view enabled observing and counting fishes, which were more abundant at dusk than dawn or noon, around the anchor. Despite remaining challenges, 360-degree cameras are useful tools for monitoring animal interactions with marine energy devices.

360-degree camera↗

Dependence of alpha-particle-driven Alfven eigenmode linear stability on device magnetic field strength and consequences for next-generation tokamaks

Recently-proposed tokamak concepts use magnetic fields up to 12 T, far higher than in conven- tional devices, to reduce size and cost. Theoretical and computational study of trends in plasma behavior with increasing field strength is critical to such proposed devices. This paper considers trends in Alfven eigenmode (AE) stability. Energetic particles, including alphas from D-T fusion, can destabilize AEs, possibly causing loss of alpha heat and damage to the device. AEs are sensitive to device magnetic field via the field dependence of resonances, alpha particle beta, and alpha orbit width. We describe the origin and effect of these dependences analytically and by using recently- developed numerical techniques (Rodrigues et al. 2015 Nucl. Fusion 55 083003). The work suggests high-field machines where fusion-born alphas are sub-Alfvenic or nearly sub-Alfvenic may partially cut off AE resonances, reducing growth rates of AEs and the energy of alphas interacting with them. High-field burning plasma regimes have non-negligible alpha particle beta and AE drive, but faster slowing down time, provided by high electron density, and higher field strength reduces this drive relative to low-field machines with similar power densities. The toroidal mode number of the most unstable modes will tend to be higher in high magnetic field devices. The work suggests that high magnetic field devices have unique, and potentially advantageous, AE instability properties at both low and high densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical properties of multi p-n junction devices

The electrical properties of multi p-n junction devices are analyzed. It is found that this type of device possesses bistable characteristics similar to that of a Shockley diode and thus provides an alternative realization of devices for switching applications. The inherently greater current gains involved in the operations of such a device yield in principle higher breakover voltages and higher holding currents. Furthermore, the incorporation of heterostructures in this device introduces a new degree of freedom in tailoring their switching characteristics. Multi p-n heterojunction devices operating as SCR lasers were fabricated, and the experimental results are presented.

Katz, J.↗

Crystal growth of device quality GaAs in space

GaAs device technology has recently reached a new phase of rapid advancement, made possible by the improvement of the quality of GaAs bulk crystals. At the same time, the transition to the next generation of GaAs integrated circuits and optoelectronic systems for commercial and government applications hinges on new quantum steps in three interrelated areas: crystal growth, device processing and device-related properties and phenomena. Special emphasis is placed on the establishment of quantitative relationships among crystal growth parameters-material properties-electronic properties and device applications. The overall program combines studies of crystal growth on novel approaches to engineering of semiconductor material (i.e., GaAs and related compounds); investigation and correlation of materials properties and electronic characteristics on a macro- and microscale; and investigation of electronic properties and phenomena controlling device applications and device performance.

Gatos, H. C.↗