Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of the neutrino-spin correlation parameter B neutron decay using ultracold neutrons

We present a new approach to measuring the neutrino-spin correlation parameter B in neutron decay. The approach combines the technology of large-area ion-implanted silicon detectors being developed for the abBA experiment, with an ultracold neutron source to provide more precise neutron polarimetry. The technique detects both proton and electron from the neutron decay in coincidence. B is determined from an electron-energy-dependent measurement of the proton spin asymmetry. This approach will provide a statistical precision of 1 x 10-4 . The systematic precision is still being evaluated, but is expected to be below 1 x 10-3 , and could approach 1 x 10-4 . A measurement of B with this precision would place constraints on supersymmetric extensions to the Standard Model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using GPU Programming for Inverse Spectroscopy

The Idaho National Laboratory (INL) has developed a detector that relies heavily on computationally expensive inverse spectroscopy algorithms to determine probabilistic three dimensional mappings of the source and its intensity. This inverse spectroscopy algorithm applies to material accountability due to the potential to determine where nuclear sources are present as a function of time and space. And yet because the novel algorithm can become prohibitively expensive on a standard desktop PC, the INL has incorporated new hardware from the commercial graphics community. General programming for graphics processing units (GPUs) is not a new concept. However, the application of GPUs to evidence theory-based inverse spectroscopy is both novel and particularly apropos. Improvements while using a (slightly upgraded) standard PC are approximately three orders of magnitude, making a ten hour computation in less than four seconds. This significantly changes the concept of prohibitively expensive calculations and makes application to materials accountability possible in near real time. Indeed, the sensor collection time is now expected to dominate the time required to determine the source and its intensity, instead of the inverse spectroscopy method.

97 MATHEMATICS AND COMPUTING↗

EMCCD-Based Detector for Time-Resolved X-Ray Diffraction and Scattering Studies of Biological Specimens

Third generation synchrotron sources such as the Advanced Photon Source (APS), Argonne, IL, are outstanding tools for X-ray diffraction and scattering studies of non-crystalline biological materials. However, these studies are hindered by the lack of detectors that provide multiple frames of detailed structural information on the millisecond time scale at the required high spatial resolution, and large active areas. Here we report the development of a cost effective detector for time-resolved small angle X-ray scattering (SAXS) using a cooled, fiberoptically coupled electron multiplying CCD (EMCCD), whose internal gain is selectable in real-time. The performance of the detector was evaluated using a Gd{sub 2}O{sub 2}S:Tb scintillator and was compared to a current state-of-the-art SAXS detector developed at Brandeis University. We also report our first results on the fabrication of a novel, microcolumnar, ZnSe(Te) scintillator that has a promise to provide very high emission efficiency of over 100,000 photons/MeV, high spatial resolution in excess of 10 lp/mm, and a fast decay time with virtually absent afterglow. Development of this scintillator will complement the EMCCD design, permitting the advances of a high spatial and temporal resolution, large area detector for time resolved applications.

43 PARTICLE ACCELERATORS↗

Development of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments

This paper presents development of an X-ray pixel detector with a multi-port charge-coupled device (MPCCD) for X-ray Free-Electron laser experiments. The fabrication process of the CCD was selected based on the X-ray radiation hardness against the estimated annual dose of 1.6 × 10{sup 14} photon/mm{sup 2}. The sensor device was optimized by maximizing the full well capacity as high as 5 Me- within 50 μm square pixels while keeping the single photon detection capability for X-ray photons higher than 6 keV and a readout speed of 60 frames/s. The system development also included a detector system for the MPCCD sensor. This paper summarizes the performance, calibration methods, and operation status.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Superconducting Tunnel Junction Far-Infrared Photon Detector for Cosmic Background Neutrino Decay Search - COBAND experiment

We present the status of development of the Superconducting Tunnel Junction (STJ) detector for the COsmic BAckground Neutrino Decay search (COBAND) experiment. The signal of the cosmic background neutrino decay is identified as a sharp cutoff at high energy end in a far-infrared region ranging from 15meV to 30meV in the energy spectrum of the photons from the space. The COBAND experiment will be done as rocket and satellite experiments in order to detect the far-infrared photons from the space. For the photon detector of the COBAND experiment, we are developing the STJ detectors. We will use a combination of the diffraction grating and the array of Nb/Al-STJ pixels with cryogenic amplifier for the rocket experiment, and use Hf-STJ without a grating for the future satellite experiment. The present status of the detector R&D and the experimental design for the COBAND experiment is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of X-Ray diffractometer by the experimental comparison method

A software for calibrating an X-ray diffractometer with area detector has been developed. It is proposed to search for detector and goniometer calibration models whose parameters are reproduced in a series of measurements on a reference crystal. Reference (standard) crystals are prepared during the investigation; they should provide the agreement of structural models in repeated analyses. The technique developed has been used to calibrate Xcalibur Sapphire and Eos, Gemini Ruby (Agilent) and Apex x8 and Apex Duo (Bruker) diffractometers. The main conclusions are as follows: the calibration maps are stable for several years and can be used to improve structural results, verified CCD detectors exhibit significant inhomogeneity of the efficiency (response) function, and a Bruker goniometer introduces smaller distortions than an Agilent goniometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation & Development of Algorithms & Techniques for Streaming Detector Readout

The advancement in microelectronics capabilities, computing, and data science in the last decade has been remarkable. With the start of the 12 GeV Science Program at Jefferson Lab (JLab) and the conceptual detector design for the upcoming Ion Collider (EIC) in mind, we have evaluated and developed the possibility of evolving and improving the existing nuclear science research workflow based on these advances. Specifically, we have prototyped components of streaming readout.

43 PARTICLE ACCELERATORS↗

Unattended Sensor System With CLYC Detectors

We have developed a next-generation unattended sensor for detecting anomalous radiation sources. The system combines several technologies to reduce size and weight, increase battery lifetime, and improve decision-making capabilities. Sixteen Cs2LiYCl6:Ce (CLYC) scintillators allow for gamma-ray spectroscopy and neutron detection in the same volume. Low-power electronics for readout, high voltage bias, and digital processing reduce the total operating power to 1.3 W. Computationally efficient analysis algorithms perform spectral anomaly detection and isotope identification. When an alarm occurs, the system transmits alarm information over a cellular modem. In this paper, we describe the overall design of the unattended sensor, present characterization results, and compare the performance to stock NaI:Tl and 3He detectors.

CLYC↗

RadSim: Math, Utility & RTK

This package includes three parts, (1) gov.llnl.math, (2)gov.llnl.utility and (3)gov.llnl.rtk, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The techniques and implementation will be entirely transparent, which will allow for improvements and boutique modifications by future researchers beyond the lifespan of this specific project. The first tool of the package, gov.llnl.math, includes classes and functions to define and perform basic math operations. Some of the example features available in the package include defining statistical distributions and performing algebra and matrix operations, all of which are already accessible on publicly available software packages such as MATLAB and ROOT. The second package gov.llnl.utility includes tools commonly used to enable optimization and readability of various data structures such as Java lists and external xml files. Lastly, the gov.llnl.rtk package includes classes and functions to implement methods commonly used in radiation physics, such as data structures to represent and characterize photon spectra and tools to apply well-defined and published methods to calibrate a given spectra.

Cheung, Hoi Sing↗

RadSim: ENSDF, Xray and N42

This package includes three parts, (1) gov.bnl.nndc.ensdf, (2) gov.nist.xray and (3) gov.nist.physics.n42, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The first tool of the package, gov.bnl.nndc.ensdf, includes functionality to parse and split publicly available decay records in ENSDF format, and pull the relevant information from ENSDF libraries. The second tool, gov.nist.xray, provides Xray information using the public NIST database. Lastly, gov.nist.physics.n42, is a tool used to convert an N42 xml file into a Java object that can be interfaced within a Java program.

Hangal, DnaushA↗

Avalanche photodiode based detector for beam emission spectroscopy

An avalanche photodiode based (APD) detector for the visible wavelength range was developed for low light level, high frequency beam emission spectroscopy (BES) experiments in fusion plasmas. This solid state detector has higher quantum efficiency than photomultiplier tubes, and unlike normal photodiodes, it has internal gain. This paper describes the developed detector as well as the noise model of the electronic circuit. By understanding the noise sources and the amplification process, the optimal amplifier and APD reverse voltage setting can be determined, where the signal-to-noise ratio is the highest for a given photon flux. The calculations are compared to the absolute calibration results of the implemented circuit. It was found that for a certain photon flux range, relevant for BES measurements ({approx_equal}10{sup 8}-10{sup 10} photons/s), the new detector is superior to both photomultipliers and photodiodes, although it does not require cryogenic cooling of any component. The position of this photon flux window sensitively depends on the parameters of the actual experimental implementation (desired bandwidth, detector size, etc.) Several detector units based on these developments have been built and installed in various tokamaks. Some illustrative results are presented from the 8-channel trial BES system installed at Mega-Ampere Spherical Tokamak (MAST) and the 16-channel BES system installed at the Torus Experiment for Technology Oriented Research (TEXTOR).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced readout methods for superheated emulsion detectors

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 μm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NuTools: Exploring Practical Roles for Neutrinos in Nuclear Energy and Security

For decades, physicists have used neutrinos from nuclear reactors to advance basic science. These pursuits have inspired many ideas for application of neutrino detectors in nuclear energy and security. While developments in neutrino detectors are now making some of these ideas technically feasible, their value in the context of real needs and constraints has been unclear. This report seeks to help focus the picture of where neutrino technology may find practical roles in nuclear energy and security. This report is the final product of the Nu Tools study, commissioned in 2019 by the DOE National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R\&D). The study was conducted over two years by a group of neutrino physicists and nuclear engineers. A central theme of the study and this report is that useful application of neutrinos will depend not only on advancing physics and technology but also on understanding the needs and constraints of potential end-users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nu Tools: Exploring Practical Roles for Neutrinos in Nuclear Energy and Security

For decades, physicists have used neutrinos from nuclear reactors to advance basic science. These pursuits have inspired many ideas for application of neutrino detectors in nuclear energy and security. While developments in neutrino detectors are now making some of these ideas technically feasible, their value in the context of real needs and constraints has been unclear. This report seeks to help focus the picture of where neutrino technology may find practical roles in nuclear energy and security. This report is the final product of the Nu Tools study, commissioned in 2019 by the DOE National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D). The study was conducted over two years by a group of neutrino physicists and nuclear engineers. A central theme of the study and this report is that useful application of neutrinos will depend not only on advancing physics and technology but also on understanding the needs and constraints of potential end-users. The Study Approach emphasized broad end-user engagement. The major effort, undertaken from May to December 2020, was a series of engagements with the wider nuclear energy and security communities. Interviews with 41 experts revealed points of common understanding, which this report captures in three Cross-Cutting Findings, a Framework for Evaluating Utility, and seven Use Case Findings. The report concludes with two Recommendations. The findings and recommendations are summarized below. The respective ordering within each category does not represent a prioritization or implied value judgement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗