Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “design validations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

GeMini: A High-Resolution, Low-Resource, Gamma-Ray Spectrometer for Planetary Science Applications

GeMini is a high-resolution gamma-ray spectrometer designed for planetary-science exploration. GeMini serves as the basis for instruments being flown on three upcoming deep-space missions: NASA’s mission to the M-class asteroid (16) Psyche, the Japan Aerospace Exploration Agency sample-return mission to the moons of Mars, and NASA’s Dragonfly mission that will land on Saturn’s largest moon, Titan. These science missions require high-resolution spectroscopy in a low-power, low-mass, rugged design that can survive in a variety of environments. GeMini addresses these needs by providing a cryogenically cooled crystal of high-purity germanium that can operate with as little as 10 to 20 watts, depending on the implementation and mission, and has a mass of less than 2 kg. GeMini helps determine the elemental composition of planetary bodies by measuring gamma rays emitted from the surface. This paper describes the mechanical, thermal, and electrical design of GeMini as well as its performance. Further, it describes testing that was performed to validate the design with respect to launch loads and radiation damage. Although the basic design of GeMini is common to all three missions, each planetary body has unique environmental conditions and mission specifications. This paper concludes by describing these upcoming missions and how GeMini is customized for each.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and experimental evaluation of compact radial-inflow turbines

The application of a multistage 3D Euler solver to the aerodynamic design of two compact radial-inflow turbines is presented, along with experimental results evaluating and validating the designs. The objectives of the program were to design, fabricate, and rig test compact radial-inflow turbines with equal or better efficiency relative to conventional designs, while having 40 percent less rotor length than current traditionally-sized radial turbines. The approach to achieving these objectives was to apply a calibrated 3D multistage Euler code to accurately predict and control the high rotor flow passage velocities and high aerodynamic loadings resulting from the reduction in rotor length. A comparison of the advanced compact designs to current state-of-the-art configurations is presented.

Fredmonski, A. J.↗

Material Plasma Exposure eXperiment High Heat Flux Microwave Absorber Design, Manufacture, and Articles Test

The Material Plasma Exposure eXperiment (MPEX) at Oak Ridge National Laboratory is in the final design phase. MPEX will be capable of exposing neutron-irradiated materials to plasmas for the study of plasma-material interaction. This facility will provide information about the complex effects of plasmas on materials and contribute to examining new materials that can withstand high heat fluxes and high ion fluences for future fusion devices. MPEX plasma is heated by 70-GHz or 105-GHz electron Bernstein wave/electron cyclotron heating (ECH), and the high-frequency microwaves are prone to scattering microwave power, which can have detrimental effects, especially on diagnostic components. A large portion of the injected ECH power is expected to be absorbed by plasma, but the remainder requires that microwave absorbers be placed immediately upstream and downstream of the ECH launcher to minimize stray microwaves leaving the ECH region. These microwaves can inadvertently heat components that cannot be shielded or otherwise protected. The microwave absorber design is based on an array of pyramid-shaped ceramic tiles brazed to a water-cooled explosion-bonded heat sink and a stainless steel plate to produce one tile module. Computational fluid dynamics and structural analyses were performed to optimize and validate the design. Multiple test coupons were produced to validate the process for brazing the two different tile materials to the Glidcop AL-15 baseplate. The articles were tested to evaluate the reliability and thermal performance through exposure to an electron beam with a heat flux of up to 1.5 MW/m2. Nondestructive testing was performed before and after testing to identify voids or separations that may have been introduced by the high heat flux. This paper discusses the details of high heat flux microwave absorber design, manufacturing details and associated challenges, and test results, demonstrating the effectiveness of the proposed design.

Hussain, Aftab↗

In-Flight Thermal Performance of the Lidar In-Space Technology Experiment

The Lidar In-Space Technology Experiment (LITE) was developed at NASA s Langley Research Center to explore the applications of lidar operated from an orbital platform. As a technology demonstration experiment, LITE was developed to gain experience designing and building future operational orbiting lidar systems. Since LITE was the first lidar system to be flown in space, an important objective was to validate instrument design principles in such areas as thermal control, laser performance, instrument alignment and control, and autonomous operations. Thermal and structural analysis models of the instrument were developed during the design process to predict the behavior of the instrument during its mission. In order to validate those mathematical models, extensive engineering data was recorded during all phases of LITE's mission. This inflight engineering data was compared with preflight predictions and, when required, adjustments to the thermal and structural models were made to more accurately match the instrument s actual behavior. The results of this process for the thermal analysis and design of LITE are presented in this paper.

Roettker, William↗

A virtual trial framework for quantifying the detectability of masses in breast tomosynthesis projection data

Purpose: Digital breast tomosynthesis (DBT) is a promising breast cancer screening tool that has already begun making inroads into clinical practice. However, there is ongoing debate over how to quantitatively evaluate and optimize these systems, because different definitions of image quality can lead to different optimal design strategies. Powerful and accurate tools are desired to extend our understanding of DBT system optimization and validate published design principles. Methods: The authors developed a virtual trial framework for task-specific DBT assessment that uses digital phantoms, open-source x-ray transport codes, and a projection-space, spatial-domain observer model for quantitative system evaluation. The authors considered evaluation of reconstruction algorithms as a separate problem and focused on the information content in the raw, unfiltered projection images. Specifically, the authors investigated the effects of scan angle and number of angular projections on detectability of a small (3 mm diameter) signal embedded in randomly-varying anatomical backgrounds. Detectability was measured by the area under the receiver-operating characteristic curve (AUC). Experiments were repeated for three test cases where the detectability-limiting factor was anatomical variability, quantum noise, or electronic noise. The authors also juxtaposed the virtual trial framework with other published studies to illustrate its advantages and disadvantages. Results: The large number of variables in a virtual DBT study make it difficult to directly compare different authors' results, so each result must be interpreted within the context of the specific virtual trial framework. The following results apply to 25% density phantoms with 5.15 cm compressed thickness and 500 {mu}m{sup 3} voxels (larger 500 {mu}m{sup 2} detector pixels were used to avoid voxel-edge artifacts): 1. For raw, unfiltered projection images in the anatomical-variability-limited regime, AUC appeared to remain constant or increase slightly with scan angle. 2. In the same regime, when the authors fixed the scan angle, AUC increased asymptotically with the number of projections. The threshold number of projections for asymptotic AUC performance depended on the scan angle. In the quantum- and electronic-noise dominant regimes, AUC behaviors as a function of scan angle and number of projections sometimes differed from the anatomy-limited regime. For example, with a fixed scan angle, AUC generally decreased with the number of projections in the electronic-noise dominant regime. These results are intended to demonstrate the capabilities of the virtual trial framework, not to be used as optimization rules for DBT. Conclusions: The authors have demonstrated a novel simulation framework and tools for evaluating DBT systems in an objective, task-specific manner. This framework facilitates further investigation of image quality tradeoffs in DBT.

60 APPLIED LIFE SCIENCES↗

A status of the Turbine Technology Team activities

The recent activities of the Turbine Technology Team of the Consortium for Computational Fluid Dynamics (CFD) Application in Propulsion Technology is presented. The team consists of members from the government, industry, and universities. The goal of this team is to demonstrate the benefits to the turbine design process attainable through the application of CFD. This goal is to be achieved by enhancing and validating turbine design tools for improved loading and flowfield definition and loss prediction, and transferring the advanced technology to the turbine design process. In order to demonstrate the advantages of using CFD early in the design phase, the Space Transportation Main Engine (STME) turbines for the National Launch System (NLS) were chosen on which to focus the team's efforts. The Turbine Team activities run parallel to the STME design work.

Griffin, Lisa W.↗

Development of CFD code evaluation criteria and a procedure for assessing predictive capability and performance

Careful validation of computational fluid dynamic (CFD) codes is essential if they are to be used as engineering design tools. Validation must be carried out in a systematic manner to ensure that all code aspects as they apply to the application of interest are understood and, to the greatest extent possible, quantified. A study is being conducted in which a general code validation procedure is defined and demonstrated. A four phase validation procedure is defined in which a series of validation test cases are computed and compared with available analytical solutions and test data. The procedure is demonstrated using the REACT CFD code to compute validation cases for each of the four phases. For phase four, the application of interest, the Space Shuttle Main Engine high pressure fuel turbopump impeller flow field, is computed.

Lin, S. J.↗

Use of multiple gauges and microwave attenuation of precipitation for satellite verification

In this paper both a microwave attenuation measurement along a horizontal line and multiple point gauge measurements are analyzed as possible ground-truth designs to validate satellite precipitation retrieval algorithms at the field of view spatial level (typically about 20 km). The design consists of comparing a sequence of pairs of contemporaneous measurements taken from the ground and from space. The authors examine theoretically the variance of expected differences between the two systems. The line average measurement leads to a smaller mean-square error compared to the case of a single point gauge, since some of the small-scale variability of the rain field is smoothed away by the line integration. The multiple point gauge measurements also give smaller mean-square error than that of a single point gauge. The centroid of the line and point gauge configurations are considered to be located randomly inside the field of view for different overpasses. A space-time spectral formalism is used with a noise-forced diffusive rain field to find the mean-square error. By considering instantaneous ground and satellite measurement pairs over about 50 visits when raining, we can reduce the expected error to approximately 10% of the standard deviation of climatological variability. This is considered to be a useful level of tolerance for identifying biases in the retrieval algorithms. It is found that the multiple point gauges (especially two gauges) are the economical ground-truth design compared to the microwave attenuation based on the mean-square error comparison. The major finding of this study is that a significant improvement over the point gauge is obtained by adding a single additional piece of information; adding more gauges or extending the line of attenuation is not an important improvement.

Ha, Eunho↗

Spacecraft Habitable Volume: Results of an Interdisciplinary Workshop

NASA's Human Exploration Framework Team posed the question: "Is 80 cubic meters per person of habitable volume acceptable for a proposed Deep Space Habitat?" The goal of the workshop was to address the "net habitable volume" necessary for long-duration human spaceflight missions and identify design and psychological issues and mitigations. The objectives were: (1) Identify psychological factors -- i.e., "stressors" -- that impact volume and layout specifications for long duration missions (2) Identify mitigation strategies for stressors, especially those that can be written as volume design specifications (3) Identify a forward research roadmap -- i.e., what future work is needed to define and validate objective design metrics? (4) Provide advisories on the human factors consequences of poor net habitable volume allocation and layout design.

Fitts, David J.↗

Developmental and Cryogenic Thermal Vacuum (TVAC) Testing Lessons Learned

Developmental thermal vacuum (TVAC) testing is a critical step in maturing hardware designs and validating performance prior to flight qualification. Unlike qualification or acceptance testing, developmental testing provides flexibility to explore design margins, uncover integration challenges, and refine test approaches before formal verification activities begin. This presentation highlights the value of developmental testing while sharing common pitfalls encountered during developmental TVAC campaigns. Lessons learned from hands-on testing experience, including extensive developmental testing at cryogenic temperatures, will be shared in this presentation. Topics include test planning and preparation, instrumentation strategies, contamination control considerations, troubleshooting unexpected anomalies, and approaches for staying on schedule while meeting test objectives. The audience will gain practical insights and best practices that can improve test efficiency, reduce risk, and enhance the overall success of future developmental TVAC efforts.

Mackenzie Byrnes↗

Serum Gamma-Glutamyl-Transferase Independently Predicts Outcome After Transarterial Chemoembolization of Hepatocellular Carcinoma: External Validation

Purpose: An Asian study showed that gamma glutamyl transpeptidase (GGT) can predict survival after transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). This study was designed to validate in a European population this biomarker as an independent predictor of outcome after TACE of HCC and to determine a threshold value for clinical use. Methods: In 88 consecutive patients treated by TACE for HCC, the optimal threshold for GGT serum level was determined by a ROC analysis. Endpoints were time-to-treatment failure (TTTF) and overall survival (OS). All multivariate models were internally validated using bootstrapping (90 replications). Results: Median follow-up lasted 373 days, and median overall survival was 748 days. The optimal threshold for GGT was 165 U/L (sensitivity: 89.3%; specificity: 56.7%; area under the ROC curve: 0.7515). Median TTTF was shorter when GGT was {>=}165 U/L (281 days vs. 850 days; P < 0.001). GGT {>=}165 U/L (hazard ratio (HR) = 2.06; P = 0.02), WHO PS of 2 (HR = 5.4; P = 0.002), and tumor size (HR = 1.12; P = 0.014) were independently associated with shorter TTTF. Median OS was shorter when GGT was {>=}165 U/L (508 days vs. not reached; P < 0.001). GGT {>=} 165 U/L (HR = 3.05; P = 0.029), WHO PS of 2 (HR = 12.95; P < 0.001), alfa-fetoprotein (HR = 2.9; P = 0.01), and tumor size (HR = 1.096; P = 0.013) were independently associated with shorter OS. The results were confirmed by bootstrapping. Conclusions: Our results provide in a European population the external validation of GGT as an independent predictor of outcome after TACE of HCC. A serum level of GGT {>=} 165 U/L is independently associated with both shorter TTTF and OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

50 MW Segmented Ultralight Morphing Rotors for Wind Energy

A multi-institutional team designed a 50 Megawatt (MW) rated wind turbine featuring downwind aeroelastic morphing to reduce blade loads and allow an ultralight segmented rotor (mass reduction of about 25% compared to a conventional upwind rotor). The team used a control co-design approach with state-of-the art simulations including for the rotor and tower design using non-linear fluid-structure interactions and control algorithms, and the team also designed, built, and field-tested an aeroelastically-scaled downwind rotor to demonstrate this novel technology and validate the design tool fidelity. In a follow-on phase, these results were used along with an updated Levelized Cost Of Energy (LCOE) methodology to co-design a more detailed set of 25 MW rated turbine designs (including individual pitch control) based on minimum LCOE with highly flexible blades for an Atlantic Ocean offshore fixed-bottom design targeted towards market technology evaluation. A set of upwind and downwind designs at 25 MW rated scales were found to provide the best LCOE, with strong improvements over all previous offshore reference turbines (NREL 5MW, DTU 10 MW and IEA 15 MW). The optimized design would represent the world’s largest offshore turbine design, which combines several state-of-the-art structural, aerodynamic, and control technologies into a new and optimized system concept.

17 WIND ENERGY↗

STOVL Control Integration Program

An integrated flight/propulsion control for an advanced vector thrust supersonic STOVL aircraft, was developed by Pratt & Whitney and McDonnell Douglas Aerospace East. The IFPC design was based upon the partitioning of the global requirements into flight control and propulsion control requirements. To validate the design, aircraft and engine models were also developed for use on a NASA Ames piloted simulator. Different flight control implementations, evaluated for their handling qualities, are documented in the report along with the propulsion control, engine model, and aircraft model.

Weiss, C.↗

Overview of the Optical Communications Demonstrator

The Optical Communications Demonstrator is a laboratory-based lasercom demonstration instrument designed to validate effective beacon acquisition, high bandwidth tracking, precision beam pointing, and point ahead compensation functions. The instrument is designed using an array detector for both spatial acquisition and high bandwidth tracking, and a fiber coupled laser transmitter. The array detector tracking concept provides wide field of view acquisition as well as high update rate using a single output channel device. At the same time, it permits effective platform jitter compensation and point ahead control using only one steering mirror. The use of fiber coupled transmitter further modularizes transmitter design and de-couples the thermal management problem. The reduction in design complexity can lead to a reduced system cost and an improved system reliability. Furthermore, it can permit the implementation of a new generation of lasercom instruments capable of realizing the inherent advantages of optical frequency communication systems.

laser↗

Next Generation Wind Turbine

The goal of this collaborative effort between Western New England University's College of Engineering and FloDesign Wind Turbine (FDWT) Corporation to wok on a novel areodynamic concept that could potentially lead to the next generation of wind turbines. Analytical studies and early scale model tests of FDWT's Mixer/Ejector Wind Turbine (MEWT) concept, which exploits jet-age advanced fluid dynamics, indicate that the concept has the potential to significantly reduce the cost of electricity over conventional Horizontal Axis Wind Turbines while reducing land usage. This project involved the design, fabrication, and wind tunnel testing of components of MEWT to provide the research and engineering data necessary to validate the design iterations and optimize system performance. Based on these tests, a scale model prototype called Briza was designed, fabricated, installed and tested on a portable tower to investigate and improve the design system in real world conditions. The results of these scale prototype efforts were very promising and have contributed significantly to FDWT's ongoing development of a product scale wind turbine for deployment in multiple locations around the U.S. This research was mutually beneficial to Western New England University, FDWT, and the DOE by utilizing over 30 student interns and a number of faculty in all efforts. It brought real-world wind turbine experience into the classroom to further enhance the Green Engineering Program at WNEU. It also provided on-the-job training to many students, improving their future employment opportunities, while also providing valuable information to further advance FDWT's mixer-ejector wind turbine technology, creating opportunities for future project innovation and job creation.

17 WIND ENERGY↗

An Experimental Study of the Ground Transportation System (GTS) Model in the NASA Ames 7- by 10-Ft Wind Tunnel

The 1/8-scale Ground Transportation System (GTS) model was studied experimentally in the NASA Ames 7- by 10-Ft Wind Tunnel. Designed for validation of computational fluid dynamics (CFD), the GTS model has a simplified geometry with a cab-over-engine design and no tractor-trailer gap. As a further simplification, all measurements of the GTS model were made without wheels. Aerodynamic boattail plates were also tested on the rear of the trailer to provide a simple geometry modification for computation. The experimental measurements include body-axis drag, surface pressures, surface hot-film anemometry, oil-film interferometry, and 3-D particle image velocimetry (PIV). The wind-averaged drag coefficient with and without boattail plates was 0.225 and 0.277, respectively. PIV measurements behind the model reveal a significant reduction in the wake size due to the flow turning provided by the boattail plates. Hot-film measurements on the side of the cab indicate laminar separation with turbulent reattachment within 0.08 trailer width for zero and +/- 10 degrees yaw. Oil film interferometry provided quantitative measurements of skin friction and qualitative oil flow images. A complete set of the experimental data and the surface definition of the model are included on a CD-ROM for further analysis and comparison.

Storms, Bruce L.↗

Bioavailability and Pharmacodynamics of Promethazine in Human Subjects

The acute effects of exposure to microgravity include the development of space motion sickness, which usually requires therapeutic intervention. The current drug of choice, promethazine (PMZ), is available to astronauts in three different dosage forms during space flight; its side effects include nausea, dizziness, sedation and impaired psychomotor performance. This ground-based study is designed to validate flight-suitable methods for pharmacodynamic evaluation of PMZ and to estimate bioavailability and pharmacodynamics of PMZ. Experimental design consists of intramuscular administration of three doses of PMZ (12.5,25 and 50 mg) and placebo in a randomized double blind fashion to human subjects and collecting blood, urine and saliva samples for 72 h. Subjects also complete cognitive performance test batteries, WinSCAT (Windows based Space Cognitive Assessment Test) and ARES (ANAM Readiness Evaluation System). Preliminary results indicate a significant relationship (p=9.88e-05) between circulating PMZ levels and cognitive performance parameters. Time to accurately complete memory tasks increases significantly with concentrations; higher concentrations also increase response time and decrease accuracy of substitution and matching tasks. AUC and half-life estimates for PMZ ranged between 0.12 and 1.7 mg.h/L and 15 and 50 h, respectively. These preliminary results indicate that PMZ may exhibit dose-dependent pharmacokinetics in humans; also, WinSCAT and ARES are sensitive for pharmacodynamic assessment of PMZ, and may be applicable for assessing the pharmacodynamics of other neurocognitive drugs.

Boyd, J. L.↗