Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Gas tube-switched high voltage DC power converter

A direct current (DC)-DC converter includes a transformer and a gas tube-switched inverter circuit. The transformer includes a primary winding and a secondary winding. The gas tube-switched inverter circuit includes first and second inverter load terminals and first and second inverter input terminals. The first and second inverter load terminals are coupled to the primary winding. The first and second inverter input terminals are couplable to a DC node. The gas tube-switched inverter circuit further includes a plurality of gas tube switches respectively coupled between the first and second inverter load terminals and the first and second inverter input terminals. The plurality of gas tube switches is configured to operate to generate an alternating current (AC) voltage at the primary winding.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

DC bulk conductive ceramic with low RF and microwave loss

A DC conductive, low RF/microwave loss titanium oxide ceramic provides, at room temperature, a bulk DC resistivity of less than 1×10 11 ohm-meters and an RF loss tangent of less than 2×10 −4 at 7.5 GHz and less than 2×10 −5 at 650 MHz. The resistivity is reduced by oxygen vacancies and associated Ti 3+ and/or Ti 4+ centers created by sintering in an atmosphere containing only between 0.01% and 0.1% oxygen. The reduced resistivity prevents DC charge buildup, while the low loss tangent provides good RF/microwave transparency and low losses. The ceramic is suitable for forming RF windows, electron gun cathode insulators, dielectrics, and other components. An exemplary Mg 2 TiO 4 —MgTiO 3 embodiment includes mixing, grinding, pre-sintering in air, and pressing 99.95% pure MgO and TiO 2 powders, re-sintering in air at 1400° C.-1500° C. to reduce porosity, and sintering at 1350° C.-1450° C. for 4 hours in an 0.05% oxygen and 99.05% nitrogen atmosphere.

Kanareykin, Alexei↗

DC Arc Flash on Photovoltaic Equipment

Protection from arc flash on ac systems is relatively well understood. Calculation approaches have been applied across many equipment types and voltages in many industries. These approaches are backed by a wide range of industry tests. Arc flash on dc systems such as photovoltaic systems is relatively unknown. Several calculation approaches have been proposed, but these have not been backed by any industry tests on equipment. Here, this report provides an overview of arc-flash hazard in terms of incident energy and arc-flash energy on photovoltaic equipment. The experiment site is a utility-owned ground-mount photovoltaic plant with a 1-MWdc nameplate capacity located at Sturbridge, MA. Three equipment arrangements were tested: a 20 × 20 × 20-in. (51 × 51 × 51-cm) box, a combiner box, and a mocked-up inverter cabinet. The results from the box testing helped to establish the characteristics of the dc source and to allow comparison to industry-standard ac testing. The results from the combiner box and inverter cabinet provided real-world results. The results were also compared with industry models of dc arc flash, and a new model was developed based on the test results.

14 SOLAR ENERGY↗

Low noise, low heat dissipation, high gain AC-DC front end amplification for scanning probe microscopy.

We report here on the design, construction and testing of a vacuum compatible AC-DC amplification system for low signal measurements with scanning probes. The most important feature of this new amplification system is incorporated within the head of a scanning tunneling microscope (STM). This is achieved with a very low thermal dissipation radio frequency amplifier at the STM head. The amplifier gain is higher than 40 dB and has a 50 dB maximum. Further, the AC noise figure is 0.7 dB between 100 and 1000 MHz. The noise induced in the DC amplifier is less than 2 pA RMS (root mean square), which enables the microscope to scan over soft insulating molecular layers. Thermal drift at the STM tip-sample interface is below 0.1 nm min{sup -1} both in air and in vacuum operation. Atomic resolution on highly oriented pyrolytic graphite surfaces is reliably achieved. Spin noise measurements are provided as an example of an application.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Compact lumped circuit model of discharges in DC accelerator using partial element equivalent circuit

DC Accelerators undergoes different types of discharges during its operation. A model depicting the discharges has been simulated to study the different transient conditions. The paper presents a Physics based approach of developing a compact circuit model of the DC Accelerator using Partial Element Equivalent Circuit (PEEC) technique. The equivalent RLC model aids in analyzing the transient behavior of the system and predicting anomalies in the system. The electrical discharges and its properties prevailing in the accelerator can be evaluated by this equivalent model. A parallel coupled voltage multiplier structure is simulated in small scale using few stages of corona guards and the theoretical and practical results are compared. The PEEC technique leads to a simple model for studying the fault conditions in accelerator systems. Compared to the Finite Element Techniques, this technique gives the circuital representation. The lumped components of the PEEC are used to obtain the input impedance and the result is also compared to that of the FEM technique for a frequency range of (0-200) MHz. (author)

43 PARTICLE ACCELERATORS↗

A High-Efficiency Isolated PFC AC-DC Topology with Reduced Number of Semiconductor Devices

A new three-level isolated ac-dc power factor correction (PFC) topology with a minimum number of semiconductor devices is the focus of this paper. This topology provides a high input power factor (PF), soft-switching, and higher efficiency than existing isolated ac-dc converters. Furthermore, the proposed circuit has lower voltage rating requirements for the secondary side devices, which leads to a lower total cost and minimizes total converter losses. This article presents a theoretical analysis describing the complete characterization of this new topology, and experimental results on a 1-kW prototype showing high PF and efficiency throughout the operating range.

42 ENGINEERING↗

DC Ionization Conductivity of Amorphous Semiconductors for Radiation Detection Applications

DC ionization conductivity measurements were used to characterize the electrical response of amorphous semi-conductors to ionizing radiation. Two different glass systems were examined: a chalcopyrite glass (CdGexAs2; for x = 0.45-1.0) with a tetrahedrally coordinated structure and a chalcogenide glass (As40Se(60-x)Tex; where x = 0-12), with a layered or three dimensionally networked structure, depending on Te content. Changes in DC ionization current were measured as a function of the type of radiation (α or γ), dose rate, applied bias voltage, specimen thickness and temperature. These results demonstrate the potential of these materials for radiation detection applications.

36 MATERIALS SCIENCE↗

DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques

This paper presents a review of control strategies, stability analysis, and stabilization techniques for dc microgrids (MGs). Overall control is systematically classified into local and coordinated control levels according to respective functionalities in each level. As opposed to local control, which relies only on local measurements, some line of communication between units needs to be made available in order to achieve the coordinated control. Depending on the communication method, three basic coordinated control strategies can be distinguished, i.e., decentralized, centralized, and distributed control. Decentralized control can be regarded as an extension of the local control since it is also based exclusively on local measurements. In contrast, centralized and distributed control strategies rely on digital communication technologies. A number of approaches using these three coordinated control strategies to achieve various control objectives are reviewed in this paper. Moreover, properties of dc MG dynamics and stability are discussed. This paper illustrates that tightly regulated point-of-load converters tend to reduce the stability margins of the system since they introduce negative impedances, which can potentially oscillate with lightly damped power supply input filters. It is also demonstrated that how the stability of the whole system is defined by the relationship of the source and load impedances, referred to as the minor loop gain. Several prominent specifications for the minor loop gain are reviewed. Finally, a number of active stabilization techniques are presented.

30 DIRECT ENERGY CONVERSION↗

An Improved Distributed Secondary Control Method for DC Microgrids With Enhanced Dynamic Current Sharing Performance

This paper proposes an improved distributed secondary control scheme for dc microgrids (MGs), aiming at overcoming the drawbacks of conventional droop control method. The proposed secondary control scheme can remove the dc voltage deviation and improve the current sharing accuracy by using voltage-shifting and slope-adjusting approaches simultaneously. Meanwhile, the average value of droop coefficients is calculated, and then it is controlled by an additional controller included in the distributed secondary control layer to ensure that each droop coefficient converges at a reasonable value. Hence, by adjusting the droop coefficient, each participating converter has equal output impedance, and the accurate proportional load current sharing can be achieved with different line resistances. Furthermore, the current sharing performance in steady and transient states can be enhanced by using the proposed method. The effectiveness of the proposed method is verified by detailed experimental tests based on a 3 × 1 kW prototype with three interface converters.

30 DIRECT ENERGY CONVERSION↗

A PCB-Embedded 1.2 kV SiC MOSFET Half-Bridge Package for a 22 kW AC–DC Converter

This article presents the design and analysis of a double-side-cooled printed circuit board (PCB) embedded silicon carbide (SiC) MOSFET half-bridge package with low loop inductances and an integrated gate driver. The 1.2 kV SiC MOSFET dies used in the half-bridge package are embedded in the PCB using AT&S's patented technique. The dies are cooled and electrically connected to traces in the PCB through copper-filled microvias. The design methodology accounts for both electrical and thermal performance, limiting the power-loop inductance to 2.3 nH and the maximum package temperature to less than the 175 °C limit. The integration of the gate drive circuitry allows for a high power density and 2.2 nH gate-loop inductances. At 0.12 K/W, the measured junction-to-case thermal resistance with double-sided cooling is 57% lower than that of a TO-247 package. Under similar operating conditions, the PCB-embedded half-bridge package also achieves a 5.6 times lower voltage overshoot and a 0.5% higher peak efficiency than a TO-247-based half-bridge. This article reports the first demonstration of PCB-embedded 1.2 kV SiC MOSFET packages in buck, boost, and ac–dc converters. Furthermore, the prototype three-phase ac–dc converter for an electric vehicle on-board charger is composed of six PCB-embedded half-bridge packages and achieves an efficiency of 98.2% and a power density of 182 W/in 3 .

42 ENGINEERING↗

DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution

DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DC-Link Capacitor Design for a Neutral-Point-Less Three-Level Dual-Phase Inverter for Traction Application

Conventional multilevel inverters, such as neutral￾point-clamped and T-type inverters, have gained popularity in electric vehicle applications due to their advantages, including high voltage range, high power capability, low switching losses, low total harmonic distortion, and low electromagnetic interference. However, these traditional multilevel inverters require a neutral point connection to generate a zero-voltage vector. The neutral point current oscillates at three times the fundamental frequency, leading to voltage imbalance and overvoltage stress on the power modules. Additionally, the use of two stacked DC-link capacitors increases the volume required for the same overall capacitance and complicates packaging due to ripple current and heat dissipation from separate components. This is a significant concern for traction drive units, where space is limited. In this paper, a neutral-point-less multilevel dual three￾phase inverter topology is investigated for traction inverter applications. Simulation results demonstrate that the proposed topology effectively retains the benefits of multilevel operation while utilizing a single DC-link capacitor. The inverter model was simulated in conjunction with an industry-standard battery model to evaluate the potential for capacitor size reduction compared to a conventional three-level inverter.

33 ADVANCED PROPULSION SYSTEMS↗

DC-8 MTP calibration for SOLVE-2

The Jet Propulsion Laboratory (JPL) Microwave Temperature Profiler (MTP) was the only instrument making temperature measurements at and below flight level on the DC-8 during the SOLVE-2 campaign. Many years of careful comparison of MTP measurements with radiosondes near the DC-8 flight track have shown that the flight level temperature can be determined to an accuracy of 0.2K relative to radiosondes.

SOLVE-2↗

New Approaches for Direct Current (DC) Balanced SpaceWire

Direct Current (DC) line balanced SpaceWire is attractive for a number of reasons. Firstly, a DC line balanced interface provides the ability to isolate the physical layer with either a transformer or capacitor to achieve higher common mode voltage rejection and or the complete galvanic isolation in the case of a transformer. And secondly, it provides the possibility to reduce the number of conductors and transceivers in the classical SpaceWire interface by half by eliminating the Strobe line. Depending on the modulator scheme the clock data recovery frequency requirements may be only twice that of the transmit clock, or even match the transmit clock: depending on the Field Programmable Gate Array (FPGA) decoder design. In this paper, several different implementation scenarios will be discussed. Two of these scenarios are backward compatible with the existing SpaceWire hardware standards except for changes at the character level. Three other scenarios, while decreasing by half the standard SpaceWire hardware components, will require changes at both the character and signal levels and work with fixed rates. Other scenarios with variable data rates will require an additional SpaceWire interface handshake initialization sequence.

Line encoding↗

New Approaches for DC Balanced SpaceWire

Direct Current (DC) line balanced SpaceWire is attractive for a number of reasons. Firstly, a DC line balanced interface provides the ability to isolate the physical layer with either a transformer or capacitor to achieve higher common mode voltage rejection and/or the complete galvanic isolation in the case of a transformer. Secondly, it provides the possibility to reduce the number of conductors and transceivers in the classical SpaceWire interface by half by eliminating the Strobe line. Depending on the modulator scheme - the clock data recovery frequency requirements may be only twice that of the transmit clock, or even match the transmit clock: depending on the Field Programmable Gate Array (FPGA) decoder design. In this paper, several different implementation scenarios will be discussed. Two of these scenarios are backward compatible with the existing SpaceWire hardware standards except for changes at the character level. Three other scenarios, while decreasing by half the standard SpaceWire hardware components, will require changes at both the character and signal levels and work with fixed rates. Other scenarios with variable data rates will require an additional SpaceWire interface handshake initialization sequence.

SpaceWire↗

Development of Hierarchical Control for a Lunar Habitat DC Microgrid Model Using Power Hardware-in-the-Loop

As interest in space exploration grows, developing a lunar habitat has become a key component of extending missions into deep space. To guarantee reliable power management of a habitat’s DC microgrid, control schemes are needed that can manage the different assets (batteries, photovoltaics, loads) effectively. Proposed hierarchical control schemes are further developed into hardware solutions using Opal-RT’s real-time simulation software and Power Hardware-in-the-Loop platform. Experimental results of a simulated DC microgrid and physical DC/DC components can allow better realization and performance of applications such as battery discharge control.

PHIL↗