Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Paralleling of LLC Resonant Converters

The LLC resonant converter is a popular, variable switching frequency DC-DC converter that may be controlled using two methods: charge and frequency control. In this paper, the application of LLC resonant converters to input-parallel, output-parallel system is studied. In this respect, the models of output-port I-V characteristics and small-signal output impedance of the charge controlled LLC converter are proposed. In addition, a mathematical framework is developed for droop-based paralleled DC-DC systems. Here, it distinctly identifies the output DC voltage and circulating current modes of stability, even in systems comprising of non-identical converters.

42 ENGINEERING↗

The AMACStar ASIC for the HL-LHC ATLAS ITk Strip detector: design, verification, testing, and quality assurance

For the high-luminosity upgrade to the LHC (HL-LHC), the ATLAS detector at CERN requires an all-new inner detector, the Inner Tracker (ITk). The ITk Strip subdetector is made up of silicon modules, which include three types of radiation-hard ASICs. One of these is the Autonomous Monitor and Control (AMAC). The AMAC is manufactured by Global Foundries using 130 nm CMOS8RF DM technology and is approximately 3 by 5 mm in size. This ASIC autonomously monitors the temperatures, voltages, and currents in the module components while controlling critical values in order to prevent these quantities from reaching dangerous levels. The final design, AMACStar, was verified, tested, and ensured to perform all necessary functions. A quality control procedure using an in-house probe station set-up was developed in order to ensure that every individual chip on each wafer of AMACStars required by the ITk Strip project met performance requirements. The average per wafer yield of usable AMACStars is 92.33%, exceeding the design-specific 90% yield estimated for project costing. This estimate was based on actual yields for similar designs in this process.

Analogue electronic circuits↗

Real-time observation of toroidal current redistributions induced by three-dimensional MHD phenomena triggering vertical displacement events in tokamak plasmas

Three-dimensional MHD instabilities, including edge-localized modes (ELMs) and internal reconnection events (IREs), have been observed to precipitate loss of vertical stability in tokamak plasmas, resulting in vertical displacement events (VDEs). This vertical destabilization can occur due to toroidal current redistributions and/or shape changes resulting from these phenomena. Using a recently introduced method for rapidly reconstructing the two-dimensional toroidal plasma current density profile in real-time, results are presented that demonstrate the specific current distribution changes that occur during ELMs (on KSTAR) and IREs (on MAST-U) that lead to loss of vertical control. The method most efficiently reconstructs the toroidal current density profile by doing so on a basis of principal components of historical profiles. These principal components isolate dominant current profile dynamics, improving interpretability, increasing speed, and reducing dimensionality of the profile computation. On KSTAR, this computation is executed in the real-time plasma control system at a rate of 10 kHz (limited by available CPU cycle times), allowing the current profile evolution to be assessed at several times over the course of each ELM event. Further, by incorporating the reconstructions into a novel vertical stability metric, the contribution of specific current profile dynamics to the loss of vertical stability can be assessed in real-time for VDE avoidance and improved understanding of the causal relationship between three-dimensional MHD phenomena and VDEs. The success of this method in approximating toroidal current density profiles from kinetic equilibrium reconstructions is also presented ($R^2=0.990$), along with its capability to produce other equilibrium quantities of interest in real-time at high time resolution.

edge-localized modes↗

A Novel Decentralized PWM Interleaving Technique for Ripple Minimization in Series-Stacked DC-DC Converters

Cascaded dc-dc converters are commonly used in applications where distributed energy sources or loads are connected to elevated voltage levels for power transfer. In such systems, it is advantageous to minimize the ripple on the bus current and voltage by proper phase shifting of the pulse-width modulation (PWM) pulses among the converters via a method known as interleaving. Existing approaches use either a centralized controller or separate communication lines among the stacked converters to control their relative PWM switch transitions. The key drawbacks are that these methods entail significant wiring, the central controller acts as a single point of failure, and implementation on very large numbers of units is impractical. In this paper, we introduce a decentralized interleaving control (DIC) strategy that acts on local current measurements at every converter and achieves communication-free PWM interleaving among the series-stacked converters. The proposed controller is simple in structure and is shown to converge asymptotically to the interleaved state irrespective of clock drifts among the digital signal processors. Experimental results are provided for a system of five series-connected converters showing a 10× reduction in the current ripple compared to normal operation.

cascaded converter↗

Defect Kinetics and Control for Module Reliability

Potential induced degradation is currently one of the most important module degradation mechanisms. It has been suggested that stacking faults decorated with sodium from the module glass are responsible for this effect and authors have also shown the reversibility of this effect upon reverse biasing of the module. The importance of sodium in the failure mechanism is clear, however, little is known regarding the factors that control its diffusion into the wafer, making it nearly impossible to predict the performance of a given module and engineer it to be better. Sodium migration from module glass into silicon cells and the resulting module degradation is a clear example of how defect kinetics can determine overall module performance and long-term reliability. To the detriment of the industry and its bankability, no quantitative models yet exist to predict defect-assisted module degradation, limiting the progress in improving reliability. In particular, the understanding of defect behavior under high electric fields, under stresses imparted by encapsulation or temperature, and under real operating conditions over long periods of time is a crucial gap in the current state-of-the-art. In this work we developed a Defect-Device-Degradation model to predict defect behavior and its impact on device performance over the module operational lifetime using experimentally-determined defect parameterizations. The validated model will provide a platform for manufacturing process optimization across input materials and architectures to avoid deleterious defects upstream and enable enhanced module robustness.

36 MATERIALS SCIENCE↗

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗

A Novel Decentralized PWM Interleaving Technique for Ripple Minimization in Series-Stacked DC-DC Converters: Preprint

Cascaded dc-dc converters are commonly used in applications where distributed energy sources or loads are connected to elevated voltage levels for power transfer. In such systems, it is advantageous to minimize the ripple on the bus current and voltage by proper phase shifting of the pulse-width modulation (PWM) pulses among the converters via a method known as interleaving. Existing approaches use either a centralized controller or separate communication lines among the stacked converters to control their relative PWM switch transitions. The key drawbacks are that these methods entail significant wiring, the central controller acts as a single point of failure, and implementation on very large numbers of units is impractical. In this paper, we introduce a decentralized interleaving control (DIC) strategy that acts on local current measurements at every converter and achieves communication-free PWM interleaving among the series-stacked converters. The proposed controller is simple in structure and is shown to converge asymptotically to the interleaved state irrespective of clock drifts among the digital signal processors. Experimental results are provided for a system of five series-connected converters showing a 10 times reduction in the current ripple compared to normal operation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Multi-harmonic Rutherford island theory

Rutherford island theory, which governs the nonlinear evolution of tearing modes in tokamak plasmas, is generalized to take into account situations in which the conventional one-harmonic approximation is not valid. The analysis incorporates non-inductive currents driven by radio frequency (RF) electromagnetic waves injected into the plasma. A multi-harmonic tearing mode dispersion relation is derived that takes the form of a nonlinear inhomogeneous matrix eigenvalue problem. The dispersion relation is solved in the so-called two-harmonic approximation, in which only the principal Fourier harmonic of the perturbed magnetic flux and its first overtone are included in the calculation. In the absence of RF current drive, the nonlinear behavior of a tearing mode predicted in the two-harmonic approximation does not differ substantially from that predicted in the one-harmonic approximation. On the other hand, RF current drive that is sufficiently localized in the vicinity of the O-points of the mode's magnetic island chain is capable of triggering bifurcations of the O-points (which is impossible in the one-harmonic approximation). However, the current drive is incapable of triggering bifurcations of the island X-points. This finding is significant because Bardóczi and Evans recently observed bifurcations of magnetic island chain O-points in the presence of RF current drive in the DIII-D tokamak but did not observe bifurcations of the X-points. Finally, the changes in the topology of the magnetic island flux-surfaces induced by RF current drive are found to facilitate the stabilization of the tearing mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toroidal modeling of 3D perturbations generated by current filaments in scrape-off layer in tokamak with biased divertor targets

The divertor biasing technique offers a promising alternative to control the edge localized mode (ELM) as well as the divertor heat load in tokamaks, as compared to the resonant magnetic perturbation (RMP) generated by magnetic coils. The linear resistive MHD code MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) is employed to study the plasma response to the n = 2 (n is the toroidal mode number) field perturbation in HL-2A, produced by the divertor biasing current filaments flowing in the scrape-off layer region. The response field due to biasing currents is compared with the RMP field utilized for ELM control in HL-2A. The strength of the radial resonant field perturbation, produced by the biasing currents of 100 A level, is found to be comparable with RMP generated by several kA of ELM control coil currents for the reference plasma. The plasma normal displacement near the X-point and the associated neoclassical toroidal viscosity torque are also computed to be similar between these two techniques. The modeling results thus strongly suggest that the biasing technique can be applied to control ELMs. Moreover, the biasing currents produce field perturbations, including the plasma response, that are localized more near the plasma edge (compared to the RMP counterpart), thus reducing the chance of mode locking associated with core perturbations. Particle orbit tracing also reveals that the biasing current produced magnetic perturbation tends to widen the heat deposition region and induce the strike point splitting of the ion saturation flow on the outer divertor surface, consistent with experimental observations in HL-2A. These toroidal modeling results confirm the possibility of ELM control and plasma exhaust solution by the divertor biasing technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Powering the Blue Economy: A Survey of Station-Keeping Methods for Mooringless Platforms

The term “ocean platform” is used to reference everything from stationary, typically moored, buoys to mobile water vehicles, whether they operate on the ocean’s surface or underwater. For certain applications for which relatively stationary station-keeping conditions are desired, the use of mooring systems is not always a viable alternative either for economic, environmental, regulatory, or otherwise practical reasons, or a combination thereof, (e.g., short deployments, sensitive ecosystems, very deep project sites). Maintaining a platform at a single waypoint or reference location without being moored would require additional control systems and a power source to counteract the drift forces that would naturally displace it. Mobile platforms, which are usually untethered except for remotely operated vehicles, typically require energy input to power their station-keeping capabilities so that they hold or control their location in the ocean. Currently, most of these platforms use combustion engines or batteries for this purpose, which, depending on the specific systems, may be costly, pollute the environment, or create limitations on the length of the deployment. However, powering this kind of platforms with surrounding renewable resources (waves, currents, winds, or sun) has been identified as a promising solution to expand their application. The intent of this report is to investigate station-keeping methods for various ocean platforms that are not moored or otherwise anchored to the ocean floor, or another platform or vessel, paying particular interest to technologies that use marine renewable resources to power their operation, because that is of particular interest to the U.S. Department of Energy’s Powering the Blue Economy (PBE) initiative. As a first step, 72 articles and technical reports related to mooringless station-keeping methods were collected for review. The preliminary literature review provided a broad overview of common themes across the literature from which a descriptive methodology for analyzing various platforms was developed. That is, station-keeping methods were categorized based on their predominant energy source and consumption (renewable, nonrenewable, or hybrid if the platform uses renewable and nonrenewable resources equally), and their localization strategy (drift reduction, “path-planning or “waypoint-holding”). In addition, platform types were segregated into the following groups: buoys, surface drifters, and unoccupied surface vehicles (USVs); offshore renewable energy systems; and unoccupied underwater vehicles (UUVs). The main types of station-keeping methods encountered in this report achieve their intended localization strategy by means of drift mitigation, steering, and/or propulsion. Drift mitigation is commonly accomplished via drogues and sea anchors. Stand-along steering subsystems use control surfaces (e.g., ship rudder, wing sail, etc.) that react to ocean currents, waves, or winds to provide varying-degrees of course adjustments. Combined steering and propulsion subsystems include differential thrusters, directional thrusters separate from a primary thruster that cause the platform to pitch up/down or yaw clockwise/counterclockwise, or vectored thrusters that direct the propulsion in a range of directions relative to the platform’s local coordinate system. Propulsion is often achieved by running a motor and applying active control strategies but can also involve buoyancy shifts and using sails to generate lifting forces that propel a platform in a desired direction. Future research is primarily expected to take place in the form of a technoeconomic analysis that would aim to determine the technological viability, cost, and added value of mooringless station-keeping use cases identified through this research, including docking for UUV recharging or for georeferencing drifter buoys, deep-sea floating wind farms, U.S. Navy sonar arrays, and a Pacific Ocean wave buoy network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NREL Infrastructure Perception and Control Workshop

A lack of highly reliable, full state-space awareness of roadway situations is the current bottleneck for the incremental introduction of smart infrastructure control. NREL's Infrastructure Perception and Control (IPC) lab applies advanced sensing and computation controls to the coordinated movement of vehicles on the road as well as people in large facilities and has produced field test results from a Colorado Springs intersection. In this presentation, NREL discusses the state of smart infrastructure control and opportunities for partnership.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Voltage-controlled magnetic anisotropy enabled by resistive switching

The discovery of new mechanisms of controlling magnetic properties by electric fields or currents furthers the fundamental understanding of magnetism and has important implications for practical use. Here, we present an approach of utilizing resistive switching to control magnetic anisotropy. We study a ferromagnetic oxide that exhibits an electrically triggered metal-to-insulator phase transition producing a volatile resistive switching. The switching occurs in a characteristic spatial pattern, the formation of an insulating barrier perpendicular to the current flow, which results in an unusual ferromagnetic/paramagnetic/ferromagnetic configuration. Further, the formation of this voltage-driven paramagnetic insulating barrier is accompanied by the emergence of a strong uniaxial magnetic anisotropy that overpowers the intrinsic material anisotropy. Our results demonstrate that resistive switching is an effective tool for manipulating magnetic properties. Because resistive switching can be induced in a broad range of materials, our findings could enable a new class of voltage-controlled magnetism systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Analysis of Grid Operator Survey Responses: Inexperience, Workload and Fatigue in the Control Room

Although a wide array of tools and technologies have been developed over the last decade to support power grid operators, deployment of these tools has been less successful. One reason for unsuccessful deployment may be an inadequate understanding of the factors that contribute to operator error in the control room. An analysis of operators’ current vulnerabilities may provide the baseline understanding needed to inform new technology integration. In an attempt to learn more about these vulnerabilities and their perceived impact on human error we collected and analyzed survey data from 20 electric grid control room operators. We asked survey respondents to consider the various operator, technology and interaction vulnerabilities that may arise during work in the control room and record their attitudes and experiences toward each. Results suggest operator inexperience, high mental workload and fatigue are the most common vulnerabilities experienced during a shift. Survey results were analyzed to explore these vulnerabilities in greater depth.

Inexperience, Workload, Fatigue↗

The Influence of Carbon Fiber Composite Specimen Design Parameters on Artificial Lightning Strike Current Dissipation and Material Thermal Damage

Previous artificial lightning strike direct effect research has examined a broad range of specimen design parameters. No works have studied how such specimen design parameters and electrical boundary conditions impact the dissipation of electric current flow through individual plies. This article assesses the influence of carbon fiber composite specimen design parameters (design parameters = specimen size, shape, and stacking sequence) and electrical boundary conditions on the dissipation of current and the spread of damage resulting from Joule heating. Thermal-electric finite element (FE) modelling is used and laboratory scale (<1 m long) and aircraft scale (>1 m long) models are generated in which laminated ply current dissipation is predicted, considering a fixed artificial lightning current waveform. The simulation results establish a positive correlation between the current exiting the specimen from a given ply and the amount of thermal damage in that ply. The results also establish that the distance to ground, from the strike location to the zero potential boundary conditions (ground), is the controlling factor which dictates the electric current dissipation in each ply. Significantly, this distance to ground is dependent on each of the specimen shape, dimensions, stacking sequence, and location of ground boundary conditions. Therefore, it is not possible to decouple current dissipation and damage from specimen design and boundary condition setup. However, it is possible to define a specimen size for a given specimen shape, stacking sequence, and waveform which limit the influence of specimen dimensions on the resulting current distribution and damage. For a rectangular specimen design which appears in literature multiple times, as 100 × 150 mm and with a stacking sequence of [45/0/-45/90] 4s , a specimen design of greater than 300 × 200 mm is required to limit the influence of specimen dimensions on current distribution and damage.

36 MATERIALS SCIENCE↗

Causal Trends for Occurrences at Sandia National Laboratories

A variety of issues and occurrences are reported at Sandia National Laboratories every year. The challenge is to filter through these occurrences and determine whether there are any notable trends related to work planning and control processes and whether some of the common problems can be mitigated or prevented. The hope is that some of the more common issues can be improved through training, communication, and/or documentation. These causal trends may also help to improve current training and work planning and control processes by revealing some opportunities for improvement.

42 ENGINEERING↗

Bridging the Void: Halogen Bonding and Aromatic Interactions to Program Luminescence and Electronic Properties of π -Conjugated Materials in the Solid State

π-Conjugated materials are promising candidates for emerging organic optoelectronic devices empowered by molecular design. The unsolved challenges of predicting and controlling their packing as solids, central to their properties and performance, currently limits their practical application. As noncovalent interactions drive packing, control over such interactions are critical to bridging from chemical structure to functional properties. In molecular crystals, halogen bonding and interactions of aromatic rings have emerged as versatile tools for noncovalent control with tailored luminescence and electronic properties. Here, we describe how the interplay of these directional and tunable interactions can engineer properties, including stimuli-responsive behavior. Specifically, halogen bonding can provide robust designs for directing 2D molecular assembly, whereas the intentional interactions of aromatic rings can yield metastable, switchable packing modes, as well as programmed stacking between layers of chromophores. Examples, herein, demonstrate clear relationships between assembly by design and resulting solid-state properties, and strategies presented offer guidance for future designs of π-conjugated molecular materials using specific aromatic interactions and halogen bonding.

36 MATERIALS SCIENCE↗

Ultra-fast transverse beam orbit control in LCLS copper linac. Part I

We report current and future experiments at LCLS require x-ray pulse trains of variable time separation on the nanosecond scale. For instance, the cavity-based XFEL (CBXFEL) will use up to 4 pulses separated by 218.5 ns, the X-ray Laser Oscillator (XLO) will use 15 to 25 ns spaced pulses, and the Matter under Extreme Conditions (MEC) experiments use pulse trains separated by 5 nanoseconds or less. In this paper, we demonstrate an ultra-fast e-beam trajectory control method based on transverse electro-magnetic (TEM) striplines and state-of-the-art power sources, to enhance LCLS operations in these regimes.

47 OTHER INSTRUMENTATION↗