Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

An automated system to define the optimal operating settings of cryogenic calorimeters

Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and stability. In this paper we present a set of automatic measurements and analysis procedures for the characterization and optimization of the working configuration of the NTD thermistors. The presented procedures were developed for CUORE, an array of 988 cryogenic macro-calorimeters instrumented with NTD thermistors that has been taking data since 2017. These procedures made it possible to characterize a large number of detectors in a reliable way. They are suitable enough to be used also in other large arrays of cryogenic detectors, such as CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on the CUORE Cryogenic System

We give here an update on the CUORE cryogenic system. It consists of a large cryogen-free cryostat cooled by five pulse tubes and one high-power specially designed dilution refrigerator built by Leiden Cryogenics. The cryostat design has been completed and it is presently under construction. The site at the Gran Sasso Underground Laboratory is ready for the installation of the cryostat which is expected to begin by the end of 2009. We discuss here the preliminary results obtained on the performance of the mechanical cryorefrigerators. We also present a measurement of the residual heat leak of the copper which has been selected for the cryostat fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic system for the MYRRHA superconducting linear accelerator

SCK⋅CEN, the Belgian Nuclear Research Centre, is designing MYRRHA, a flexible fast spectrum research reactor (80 MW{sub th}), conceived as an accelerator driven system (ADS), able to operate in sub-critical and critical modes. It contains a continuous-wave (CW) superconducting (SC) proton accelerator of 600 MeV, a spallation target and a multiplying core with MOX fuel, cooled by liquid lead-bismuth (Pb-Bi). From 17 MeV onward, the SC accelerator will consist of 48 β=0.36 spoke-loaded cavities (352 MHz), 34 β=0.47 elliptical cavities (704 MHz) and 60 β=0.65 elliptical cavities (704 MHz). We present an analysis of the thermal loads and of the optimal operating temperature of the cryogenic system. In particular, the low operating frequency of spoke cavities makes their operation in CW mode possible both at 4.2 K or at 2 K. Our analysis outlines the main factors that determine at what temperature the spoke cavities should be operated. We then present different cryogenic fluid distribution schemes, important characteristics (storage, transfer line, etc.) and the main challenges offered by MYRRHA in terms of cryogenics.

43 PARTICLE ACCELERATORS↗

Shock compression of liquid helium and helium-hydrogen mixtures : development of a cryogenic capability for shock compression of liquid helium on Z, final report for LDRD Project 141536.

This final report on SNL/NM LDRD Project 141536 summarizes progress made toward the development of a cryogenic capability to generate liquid helium (LHe) samples for high accuracy equation-of-state (EOS) measurements on the Z current drive. Accurate data on He properties at Mbar pressures are critical to understanding giant planetary interiors and for validating first principles density functional simulations, but it is difficult to condense LHe samples at very low temperatures (<3.5 K) for experimental studies on gas guns, magnetic and explosive compression devices, and lasers. We have developed a conceptual design for a cryogenic LHe sample system to generate quiescent superfluid LHe samples at 1.5-1.8 K. This cryogenic system adapts the basic elements of a continuously operating, self-regulating {sup 4}He evaporation refrigerator to the constraints of shock compression experiments on Z. To minimize heat load, the sample holder is surrounded by a double layer of thermal radiation shields cooled with LHe to 5 K. Delivery of LHe to the pumped-He evaporator bath is controlled by a flow impedance. The LHe sample holder assembly features modular components and simplified fabrication techniques to reduce cost and complexity to levels required of an expendable device. Prototypes have been fabricated, assembled, and instrumented for initial testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryogenic Fluid Management Technologies Enabling for the Artemis Program and Beyond

NASA is endeavoring on an ambitious return to the Moon and eventually on to Mars through the Artemis Program leveraging innovative technologies to establish sustainable exploration architectures collaborating with US commercial and international partners[1]. Future NASA architectures have baselined cryogenic propulsion systems to support lunar missions and ultimately future missions to Mars. NASA has been investing in maturing CFM active and passive storage, transfer, and gauging technologies over the last decade plus primarily focused on ground development with a few small-scale microgravity fluid experiments. Recently, NASA created a Cryogenic Fluid Management (CFM)Technology Roadmap identifying the critical gaps requiring further development to reach a technology readiness level (TRL) of 6 prior to infusion to flight applications. To address the technology gaps the Space Technology Mission Directorate(STMD)strategically plans to invest in a diversified CFM portfolio approach through ground and flight demonstrations ,collaborating with international partners, and leveraging Public Private Partnerships (PPPs) opportunities with US industry through the Tipping Point and Announcement of Collaborative Opportunities (ACO) solicitations. Once proven, these system capabilities will enable the high performing cryogenic propellant systems needed for the Artemis Program and beyond.

Cryogenic Fluid Management↗

Cryogenic Fluid Management for the Artemis Program and Beyond

NASA is endeavoring on an ambitious return to the Moon and eventually on to Mars through the Artemis Program leveraging innovative technologies to establish sustainable exploration architectures collaborating with US commercial and international partners [1]. Future NASA architectures have baselined cryogenic propulsion systems to support lunar missions and ultimately future missions to Mars. NASA has been investing in maturing CFM active and passive storage, transfer, and gauging technologies over the last decade plus primarily focused on ground development with a few small-scale microgravity fluid experiments. Recently, NASA created a Cryogenic Fluid Management (CFM) Technology Roadmap identifying the critical gaps requiring further development to reach a technology readiness level (TRL) of 6 prior to infusion to flight applications. To address the technology gaps the Space Technology Mission Directorate (STMD) strategically plans to invest in a diversified CFM portfolio approach through ground and flight demonstrations, collaborating with international partners, and leveraging Public Private Partnerships (PPPs) opportunities with US industry through the Tipping Point and Announcement of Collaborative Opportunities (ACO) solicitations. Once proven, these system capabilities will enable the high performing cryogenic propellant systems needed for the Artemis Program and beyond.

Cryogenic Fluid Management↗

Cryogenic sub-system for the 56 MHz SRF storage cavity for RHIC

A 56 MHz Superconducting RF Storage Cavity is being constructed for the RHIC collider. This cavity is a quarter wave resonator that will be operated in a liquid helium bath at 4.4 K. The cavity requires an extremely quiet environment to maintain its operating frequency. The cavity, besides being engineered for a mechanically quiet system, also requires a quiet cryogenic system. The helium is taken from RHIC's main helium supply header at 3.5 atm, 5.3K at a phase separator tank. The boil-off is sent back to the RHIC refrigeration system to recover the cooling. To acoustically separate the RHIC helium supply and return lines, a condenser/boiler heat exchanger condenses the helium vapor generated in the RF cavity bath. A system description and operating parameters are given about the cryogen delivery system. The 56 MHz superconducting storage RF cavity project is making progress. The cryogenic system design is in its final stage. The helium supply lines have been tapped into the RHIC helium distribution lines. The plate-and-fin heat exchanger design is near completion and specification will be sent out for bid soon. The cold helium vapor heating system design will start soon as well. A booster compressor specification is underway. The first phase separator and transfer line design work is near completion and will be sent out for bid soon.

43 PARTICLE ACCELERATORS↗

Structural dynamics and rejuvenation during cryogenic cycling in a Zr-based metallic glass

Subjecting metallic glasses repeatedly to liquid nitrogen temperature has become a popular method to homogeneously rejuvenate the material. Here in this paper we reveal the atomic-scale structural dynamics using in-situ x-ray photon correlation spectroscopy (XPCS) during and after cryogenic cycling of a Zr-based metallic glass in two structural states (plate and ribbon). Heterogeneous structural dynamics is observed at 300 K that changes to monotonic aging at 78 K. It is found that cryogenic cycling homogenizes the relaxation time distribution. This effect is much more pronounced in the ribbon, which is the only structural state that rejuvenates upon cycling. We furthermore reveal how fast atomic-scale dynamics is correlated with long-time structural relaxation times irrespective of the structural state, and that the ribbon exhibits unexpected additional fast atomic-scale relaxation in comparison to the plate material. A structural picture emerges that points towards heterogeneities in the fictive temperature as a requirement for cryogenic energy storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An optimization approach for cryogenic distillation-based protium removal systems in magnetic fusion energy fuel cycles

Tritium inventory reduction for fusion power plants is central to the successful adoption of fusion energy. The advent of direct internal recycling in deuterium-tritium fusion fuel cycle design has led to significant reduction in startup tritium inventory estimates for fusion power plants but requires an isotope rebalancing and protium removal (IRPR) system to ensure acceptable isotopic fuel composition. Cryogenic distillation is a potential solution for near-term deployment in an IRPR system due to its demonstrated performance in similar operating regimes. Using protium removal in the fuel cycle as the primary performance metric, this paper presents an optimization methodology for a single-column continuous cryogenic distillation-based IRPR system for a 500 MW fus magnetic fusion device. Distillation column optimization was performed using the CryOgenic Distillation For Isotopic Separation of Hydrogen (CODFISH) code developed at Savannah River National Laboratory. The distillation column design presented maximizes direct recycling of hydrogen isotopes from the fusion chamber exhaust to the fueling system while minimizing IRPR system steady-state tritium inventory. The optimized IRPR distillation column presented achieves direct recycling of 60 % of the hydrogen isotopes in the fusion chamber exhaust with an estimated steady-state system tritium inventory <30 g. In conclusion, the optimized IRPR distillation column operation was then used to estimate the design requirements for a detritation column to treat the IRPR system effluent stream.

CryOgenic distillation↗

Evolution of microstructures and mechanical properties during solution treatment of a Ti–V–Mo-containing high‑manganese cryogenic steel

Highlights: • High-Mn cryogenic steels are getting the spotlight in the cryogenic market. • The grain size grew slowly and the yield strength remained almost stabilized with an increase of solutionizing temperature. • The Hall–Petch strengthening coefficient for yield strength was small, estimated to be 153 MPa μm{sup 0.5}. • The weakening effect of solutionizing temperature on grain size was attributed to the nano-sized (Ti, V, Mo)C precipitate. - Abstract: The effect of solution treatment on the microstructure and mechanical properties of a high‑manganese (Mn) twin-induced plastic (TWIP) cryogenic steel that was alloyed from elemental titanium (Ti), vanadium (V) and molybdenum (Mo) was investigated by a variety of techniques such as microstructural characterization, room tensile testing and − 196 °C impact testing. The austenite grain size grew slowly with an increase of the solutionizing temperature (ST). The relatively weak effect of the ST on the austenite grain size is attributed to the superior thermal stability and coarsening resistance of the (Ti, V, Mo)C precipitate, which hindered austenite grain growth. An increase in ST improved the low-temperature toughness (LTT) significantly and decreased the strain hardening rate (SHR), but had no significant effect on the yield strength. The Hall–Petch strengthening coefficient for yield strength was small, and was estimated to be 153 MPa μm{sup 0.5}. Undissolved large-sized chromium (Cr) carbide can deteriorate the LTT significantly. Because of its excellent mechanical properties, high-Mn steel that was alloyed by elemental Ti, V and Mo can be used to manufacture storage tanks for liquefied natural gas.

36 MATERIALS SCIENCE↗

Performance of the first 150 mm diameter Cryogenic silicon ionization detectors with contact-free electrodes

Cryogenic semiconductor detectors operated at temperatures below 100 mK are commonly used in particle physics experiments searching for dark matter. The largest such germanium and silicon detectors, with diameters of 100 mm and thickness of 33 mm, are planned for use by the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at SNOLAB, Canada. Still larger individual detectors are being investigated to scale up the sensitive mass of future experiments. We present here the first results of testing two prototype 150 mm diameter silicon ionization detectors. The detectors are 25 mm and 33 mm thick with masses 1.7 and 2.2 times larger than those currently planned for SuperCDMS. These devices were operated with contact-free bias electrodes to minimize leakage currents which currently limit operation at high bias voltages. The results show promise for the use of such technologies in solid state cryogenic detectors.

150 mm↗

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE↗

Laboratory-Based Cryogenic Soft X-ray Tomography with Correlative Cryo-Light and Electron Microscopy

Here we present a novel laboratory-based cryogenic soft X-ray microscope for whole cell tomography of frozen hydrated samples. We demonstrate the capabilities of this compact cryogenic microscope by visualizing internal sub-cellular structures of Saccharomyces cerevisiae cells. The microscope is shown to achieve better than 50 nm spatial resolution with a Siemens star test sample. For whole biological cells, the microscope can image specimens up to 5 micrometers thick. Structures as small as 90 nm can be detected in tomographic reconstructions at roughly 70 nm spatial resolution following a low cumulative radiation dose of only 7.2 MGy. Furthermore, the design of the specimen chamber utilizes a standard sample support that permits multimodal correlative imaging of the exact same unstained yeast cell via cryo-fluorescence light microscopy, cryo-soft x-ray microscopy and cryo-transmission electron microscopy. This completely laboratory-based cryogenic soft x-ray microscope will therefore enable greater access to three-dimensional ultrastructure determination of biological whole cells without chemical fixation or physical sectioning.

Compact light source↗

Nanoscale Structural Evolution and Anomalous Mechanical Response of Nanoglasses by Cryogenic Thermal Cycling

One of the central themes in the amorphous materials research is to understand the nanoscale structural responses to mechanical and thermal agitations, the decoding of which is expected to provide new insights into the complex amorphous structural-property relationship. For common metallic glasses, their inherent atomic structural inhomogeneities can be rejuvenated and amplified by cryogenic thermal cycling, thus can be decoded from their responses to mechanical and thermal agitations. In this paper, we reported an anomalous mechanical response of a new kind of metallic glass (nanoglass) with nanoscale interface structures to cryogenic thermal cycling. As compared to those metallic glasses by liquid quenching, the Sc 75 Fe 25 (at. %) nanoglass exhibits a decrease in the Young’s modulus but a significant increase in the yield strength after cryogenic cycling treatments. The abnormal mechanical property change can be attributed to the complex atomic rearrangements at the short- and medium- range orders due to the intrinsic nonuniformity of the nanoglass architecture. The present work gives a new route for designing high-performance metallic glassy materials by manipulating their atomic structures and helps for understanding the complex atomic structure–property relationship in amorphous materials.

36 MATERIALS SCIENCE↗

Experiments on Cryogenic Complex Plasma

Experiments on a cryogenic complex plasma have been performed. Preliminary experiments include production of a plasma in a liquid helium or in a cryogenic helium gas by a pulsed discharge. The extended production of a plasma has been realized in a vapor of liquid helium or in a cryogenic helium gas by rf discharge. The charge of dust particles injected in such a plasma has been studied in detail.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superconducting THz Camera with GaAs‐JFET Cryogenic Readout Electronics

We describe the development of large format array of superconducting tunnel junction detectors that is readout by SONY GaAs‐JFET cryogenic integrated circuits. High quality SIS photon detectors have high dynamic impedance that can be readout by low gate leakage GaAs‐JFET circuits. Our imaging array design, with niobium SIS photon detectors and GaAs‐JFET cryogenics electronics, uses integrating amplifiers, multiplexers and shift‐registers to readout large number of pixels that is similar to CMOS digital cameras. We have designed and fabricated GaAs‐JFET cryogenic integrated circuits, such as AC‐coupled capacitive trans‐impedance amplifier, multiplexers with sample‐and‐holds and shift‐registers, for 32‐channel readout module. The Advanced Technology Center of National Astronomical Observatory of Japan have started extensive development program for large format array of SIS photon detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAFETY ASPECTS OF BIG CRYOGENIC SYSTEMS DESIGN

Superconductivity and helium cryogenics are key technologies in the construction of large scientific instruments, like accelerators, fusion reactors or free electron lasers. Such cryogenic systems may contain more than hundred tons of helium, mostly in cold and high-density phases. In spite of the high reliability of the systems, accidental loss of the insulation vacuum, pipe rupture or rapid energy dissipation in the cold helium can not be overlooked. To avoid the danger of over-design pressure rise in the cryostats, they need to be equipped with a helium relief system. Such a system is comprised of safety valves, bursting disks and optionally cold or warm quench lines, collectors and storage tanks. Proper design of the helium safety relief system requires a good understanding of worst case scenarios. Such scenarios will be discussed, taking into account different possible failures of the cryogenic system. In any case it is necessary to estimate heat transfer through degraded vacuum superinsulation and mass flow through the valves and safety disks. Even if the design of the helium relief system does not foresee direct helium venting into the environment, an occasional emergency helium spill may happen. Helium propagation in the atmosphere and the origins of oxygen-deficiency hazards will be discussed.

42 ENGINEERING↗

Measuring symmetry of implosions in cryogenic Hohlraums at the NIF using gated x-ray detectors (invited)

Ignition of imploding inertial confinement capsules requires, among other things, controlling the symmetry with high accuracy and fidelity. We have used gated x-ray imaging, with 10 {mu}m and 70 ps resolution, to detect the x-ray emission from the imploded core of symmetry capsules at the National Ignition Facility. The measurements are used to characterize the time dependent symmetry and the x-ray bang time of the implosion from two orthogonal directions. These measurements were one of the primary diagnostics used to tune the parameters of the laser and Hohlraum to vary the symmetry and x-ray bang time of the implosion of cryogenically cooled ignition scale deuterium/helium filled plastic capsules. Here, we will report on the successful measurements performed with up to 1.2 MJ of laser energy in a fully integrated cryogenics gas-filled ignition-scale Hohlraum and capsule illuminated with 192 smoothed laser beams. We will describe the technique, the accuracy of the technique, and the results of the variation in symmetry with tuning parameters, and explain how that set was used to predictably tune the implosion symmetry as the laser energy, the laser cone wavelength separation, and the Hohlraum size were increased to ignition scales. We will also describe how to apply that technique to cryogenically layered tritium-hydrogen-deuterium capsules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗