Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryocoolers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

The rise of neutron cryo-crystallography

The use of boiled-off liquid nitrogen to maintain protein crystals at 100 K during X-ray data collection has become almost universal. Applying this to neutron protein crystallography offers the opportunity to significantly broaden the scope of biochemical problems that can be addressed, although care must be taken in assuming that direct extrapolation to room temperature is always valid. Here, the history to date of neutron protein cryo-crystallography and the particular problems and solutions associated with the mounting and cryocooling of the larger crystals needed for neutron crystallography are reviewed. Finally, the outlook for further cryogenic neutron studies using existing and future neutron instrumentation is discussed.

59 BASIC BIOLOGICAL SCIENCES↗

GeMini: The Next-Generation Mechanically-Cooled Germanium Spectrometer

The next-generation mechanically-cooled germanium spectrometer has been developed. GeMini (MINIature GErmanium spectrometer) has been designed to bring high-resolution gamma-ray spectroscopy to a range of demanding field environments. Intended applications include short-notice inspections, border patrol, port monitoring and emergency response, where positive nuclide identification of radioactive materials is required but power and liquid cryogen are not easily available. GeMini weighs 2.75 kg for the basic instrument and 4.5 kg for the full instrument including user interface and ruggedized hermetic packaging. It is very low power allowing it to operate for 10 hours on a single set of rechargeable batteries. This instrument employs technology adapted from the gamma-ray spectrometer currently flying on NASA's Mercury MESSENGER spacecraft. Specifically, infrared shielding techniques allow for a vast reduction of thermal load. This in turn allows for a smaller, lighter-weight design, well-suited for a hand-held instrument. Three working prototypes have been built and tested in the lab. The measured energy resolution is 3 keV fwhm at 662 keV gamma-rays. This paper will focus on the design and performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HTS Dipole Prototype Magnet for NSLS X13A Endstation

This article reports the design, three-dimensional magnetostatic simulation results, coil fabrication, assembly, and low-temperature test results of a C-frame, iron-dominated high-temperature superconductor dipole magnet for ultra high vacuum magnetic-sensitive spectroscopy techniques at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory. The magnet is required to provide fields up to ~1 T along two spatial directions. With an added capability to rotate about its vertical axis of symmetry, the magnet system is capable of delivering field along all three principal axes. The combination of this magnet and fast-switched, elliptically polarized soft X-rays produced by the NSLS elliptically polarized wiggler forms the basis for an excellent tool for polarization-sensitive studies of magnetic materials. The prototype magnet consists of a set of pancake coils fabricated from BSCCO tape reinforced with stainless steel. Those pancake coils are clamped in a low-carbon AISI 1006 grade steel pole and yoke assembly. For testing purposes, a cold He gas environment provided cooling the superconducting magnet to subtransition temperatures; for operation in an ultra high vacuum endstation environment, cooling can be provided by an external cryocooler. The low-temperature tests establish the safe-operating parameters needed to achieve the target magnetic field values. The measured magnetic field values are in close agreement with the magnetic simulation results, thereby confirming that the magnet design fulfills the performance requirements. Here, the final section of this article lists some suggestions to improve the magnet performance.

36 MATERIALS SCIENCE↗

Cryogenic Considerations for Superconducting Magnet System Design for the Material Plasma Exposure eXperiment (MPEX)

The Material Plasma Exposure eXperiment (MPEX) has been proposed as a facility to address plasma material interaction knowledge gaps to qualify and develop materials and technologies that surround plasma environments for future fusion reactors. Utilizing different radio-frequency (rf) heating technologies, MPEX is a linear plasma device that will generate fusion reactor–like plasmas with energies and particle fluxes at the target materials with electron temperatures of 1 to 15 eV, electron densities of 10 20 to 10 21 m -3 , and ion fluxes greater than 10 24 m -2 s -1 . Starting with the MPEX requirements with respect to magnetic fields between 0.1 and 2.5 T and warm bores of either 0.65 m or 1.56 m, conceptual designs for a superconducting magnet system have been developed that utilize multiple NbTi windings distributed across seven cryostats to accommodate rf heating, water cooling, and vacuum systems needed for MPEX. While the cryogenic and magnet technologies relative to the field and space requirements are mature, the integration of these technologies across multiple cryostats presents several technical and logistical challenges. An analysis of the preferred refrigeration approach, modular recondensing liquid helium cryocoolers, was performed. Utilizing a design margin of a factor of two, this approach is feasible within the current design requirements for MPEX with some considerations related to its implementation within the thermal shields and the magnet subsystem geometries.

Duckworth, Robert↗

A Preliminary Thermal Model of the LHe-based SCAPE Cryostat

The SCAPE (SuperConducting Arbitrarily Polarizing Emitter) undulator is under development at the Advanced Photon Source (APS). This new undulator requires a cryostat that will be designed based on expected heat loads. For instance, the expected heating of the beam chamber by electron beam is estimated to be at a level of 182 W – much higher than in planar SCUs. This and other challenges require careful thermal analysis of the LHe-based SCAPE cryostat. A detailed thermal model of the LHe-based SCAPE cryostat has been created in ANSYS. This paper presents calculated cooling capacity and temperatures of the SCAPE cryostat for the static and dynamic heat loads. Index Terms—SCAPE (SuperConducting Arbitrarily Polarizing Emitter), cryocooler, LHe, thermal isolation, thermal conductance.

Shiroyanagi, Y.↗

A PRELIMINARY CRYOGENIC PERFORMANCE TEST OF THE 4.8-M-LONG CRYOSTAT FOR SUPERCONDUCTING UNDULATORS

A 4.8-m-long cryostat has been developed to cool a pair of 1.9-m-long planar superconducting undulator magnets (SCUs). The final design and the thermal model of this cryocooler-cooled LHe-based cryostat have been completed. The cryostat is fabricated, and a preliminary cooldown test has been performed. This paper presents a comparison between measured and calculated thermal performance of the 4.8-m-long cryostat for the SCU.

Shiroyanagi, Y.↗

Cryogenic System Preliminary Design for a 0.5m-Long, Conduction-Cooled Nb3Sn Undulator Magnet Prototype

There are several NbTi superconducting undulator (SCU) magnets currently in operation at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The development on Nb3Sn-based superconducting undulator magnets at APS is underway due to the potential to further enhance the performance of the SCUs. Superconducting undulator magnets need to keep temperature gradients minimized in order to retain thermal and operating current margin. We have designed the thermal links for efficient heat conduction using 3D finite element analysis (FEA) simulation in COMSOL Multiphysics software, which was later used for the calculation of the temperature distribution across a 0.5 m long, conduction-cooled, Nb3Sn undulator magnet prototype that includes both conductive heat transfer and radiative heating components. We have modelled the evolution of the thermal properties of the magnet winding as well as other cold parts during cool-down from ambient temperature with the operation of a SHI RDK-415D cryocooler to examine the estimated time that is needed for the cooldown as well as the baseline temperature we could achieve. A key result was that a maximum coil delta T = 0.11 K along the designed thermal links and a temperature range of 3.42 K-3.53 K for the winding were predicted at steady state. A pair of G10 support rods for carrying the magnet as well as a pair of current leads made of metals were also designed and optimized for the testing system, targeting for an operation temperature of 4 K and a coil current of 950 A DC.

Zhang, Danlu↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

Thermal Performance of a Conduction-Cooled CCT Dipole ReBCO Magnet: Several Cycles of Cool-Down and Thermal Gradient Measurements

Here, this paper presents experimental results from conduction-cooled thermal testing of a ReBCO canted cosine theta (CCT) magnet (C2), originally designed and fabricated at LBNL using CORC cables. While the performance of the coil under liquid helium and nitrogen environments has been previously established, this study explores its behavior under conduction cooling using a large test cryostat at The Ohio State University. The magnet, measuring 613 mm in length and weighing ∼75 kg, consists of four helical layers wound with ReBCO-based CORC wire and was thermally anchored to a copper cold ring supported by a G-10 strongback. Cooling was provided by two Sumitomo RDK-415D cryocoolers, offering a combined 3 W at 4.2 K and 150 W at 77 K. Multiple thermal cycles were performed, with cooldown durations of up to 45 hours. Final base temperatures of approximately 10.8 K (at the coil edge) and 12.0 K (at the coil center) were achieved, with an axial temperature difference of approximately 1.2 K. The warm-up period extended over approximately 24.6 hours. Voltage measurements from all four layers were recorded during cooldown and warmup. The system demonstrated stable cooldown performance, repeatable gradients, and good thermal anchoring. These results support the feasibility of conduction cooling in large-scale HTS magnets, aligning with broader goals for “green” cryogen-free accelerator technologies and paving the way for more sustainable, scalable, and energy-efficient high-field magnet systems in next-generation particle accelerators.

Canted cosine theta magnets↗

A Superconducting Tunnel Junction X-ray Spectrometer without Liquid Cryogens

Superconducting tunnel junctions (STJs) are being developed as X-ray detectors because they combine the high energy resolution of cryogenic detector technologies with the high count rate capabilities of athermal devices. We have built STJ spectrometers for chemical analysis of dilute samples by high-resolution soft X-ray spectroscopy at the synchrotron. The instruments use 36 pixels of 200 {micro}m x 200 {micro}m Nb-Al-AlOx-Al-Nb STJs with 165 nm thick Nb absorber films. They have achieved an energy resolution of {approx}10-20 eV FWHM for X-ray energies below 1 keV, and can be operated at a total count rate of {approx}10{sup 6} counts/s. For increased user-friendliness, we have built a liquid-cryogen-free refrigerator based on a two-stage pulse tube cryocooler in combination with a two-stage adiabatic demagnetization stage. It holds the STJ detector at the end of a 40-cm-long cold finger, and attains the required operating temperature of {approx}0.3 K at the push of a button. We describe the instrument performance and present speciation measurements on Eu dopant activators in the novel scintillator material SrI{sub 2} to illustrate the potential for STJ spectrometers at the synchrotron.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a Continuous Pellet Fueling System for Wendelstein 7-X

A continuous pellet fueling system (CPFS) is currently being designed at the Oak Ridge National Laboratory (ORNL) for the long pulse operation of the Wendelstein 7-X (W7-X) stellarator. The purpose of the CPFS is to provide deep continuous fueling for feedback-controlled high-density operation and mitigation of predicted hollow density profiles. As described here, the system will provide the capability to inject cylindrical pellets of solid hydrogen or deuterium into the plasma core, with flexibility to vary the pellet size, velocity, and injection frequency. Pellets are nominally of 3 mm in diameter and have a length between 1 and 4 mm. The heart of the CPFS is a vertically oriented, twin-screw extruder, cooled by three Gifford-McMahon cryocoolers in parallel, designed to form a continuous filament of hydrogen or deuterium. The filament width, which determines the pellet length, can be adjusted by means of a variable nozzle driven by a linear actuator at the base of the extruder. Coupled to the nozzle is a solenoid-operated gas gun and cutter assembly. A pneumatic propellant valve pulses a burst of ~60 bar helium to accelerate the cut pellet into W7-X. Three gaps in the guide tubes provide pumping locations to remove the helium propellant before it reaches the plasma. The maximum velocity of the pellet is limited by its ability to survive navigating the guide tube trajectory intact. A microwave cavity located within the guide tube provides the capability to measure the pellet size and velocity. The mechanical and thermal designs of the W7-X extruder, adjustable nozzle, and gun and cutter assembly design are described. A guide tube design and experimental pellet survivability test results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

What more can be done with XPS? Highly informative but underused approaches to XPS data collection and analysis

Because of the importance of surfaces and interfaces in many scientific and technological areas, the use of x-ray photoelectron spectroscopy (XPS) has been growing exponentially. Although XPS is being used to obtain useful information about the surface composition of samples, much more information about materials and their properties can be extracted from XPS data than commonly obtained. This paper describes some of the areas where alternative analysis methods or experimental design can obtain information about the near-surface region of a sample, often information not available in other ways. Experienced XPS analysts are familiar with many of these methods, but they may not be known to new or casual XPS users, and sometimes, they have not been used because of an inappropriately assumed complexity. The information available includes optical, electronic, and electrical properties; nanostructure; expanded chemical information; and enhanced analysis of biological materials and solid/liquid interfaces. Many of these analyses can be conducted on standard laboratory XPS systems, with either no or relatively minor system alterations. Topics discussed include (1) considerations beyond the “traditional” uniform surface layer composition calculation, (2) using the Auger parameter to determine a sample property, (3) use of the D parameter to identify sp 2 and sp 3 carbon information, (4) information from the XPS valence band, (5) using cryocooling to expand range of samples that can be analyzed and minimize damage, and (6) using electrical potential effects on XPS signals to extract chemically resolved electrical measurements including band alignment and electrical property information.

Baer, Donald R. [Pacific Northwest National Labora↗

Combining molecular beam epitaxy and low-energy electron microscopy with in situ magnetic susceptibility measurements within an integrated ultrahigh vacuum system

Quantum two-dimensional materials, including ultrathin superconducting films, are of great current research interest. These films are typically fabricated under ultra-high vacuum (UHV) conditions and are sensitive to the environment—prone to oxidation and contamination when exposed to the atmosphere. This hampers the study of their intrinsic properties by standard ex situ techniques. Here, we present a variable-temperature mutual inductance probe system integrated under UHV with molecular beam epitaxy (MBE) synthesis and low-energy electron microscopy, enabling nondestructive in situ characterization of superconducting thin films. The system employs a reflection-type configuration and reaches a low temperature (∼4 K) using a high-cooling-power, vibration-isolated cryocooler. In conclusion, we demonstrate the system performance by measuring the superconducting critical temperature in a copper-oxide thin film.

2D materials↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

Design study of a laser-cooled infrared sensor

The performance of a solid-state optical refrigerator is the result of a complex interplay of numerous optical and thermal parameters. We present a first preliminary study of an optical cryocooler using ray-tracing techniques. A numerical optimization identified a non-resonant cavity with astigmatism. This geometry offered more efficient pump absorption by the YLF:10%Yb laser-cooling crystal compared to non-resonant cavities without astigmatism that have been pursued experimentally so far. Ray tracing simulations indicate that ~80% of the incident pump light can absorbed for temperatures down to ~100 K. Calculations of heat loads, cooling power, and net payload heat lift are presented. They show that it is possible to cool a payload to a range of 90–100 K while producing a net payload heat lift of 80 mW and 300 mW when pumping a YLF:10%Yb crystal with 20 W and 50 W at 1020 nm, respectively. This performance is suited to cool HgCdTe infrared detectors that are used for sensing in the 8–12 μm atmospheric window. While the detector noise would be ~6× greater at 100 K than at 77 K, the laser refrigerator would introduce no vibrations and thus eliminate sources of microphonic noise that are limiting the performance of current systems.

47 OTHER INSTRUMENTATION↗

Crystal-field effects in fluoride crystals for optical refrigeration

The field of optical refrigeration of rare-earth-doped solids has recently seen an important breakthrough. The cooling of a YLiF{sub 4} (YLF) crystal doped with 5 mol% Yb3+ to 155 K by Seletskiy et al [NPhot] has surpassed the lowest temperatures ({approx}170 K for {approx}100 mW cooling capacity) that are practical with commercial multi-stage thermoelectric coolers (TEC) [Glaister]. This record performance has advanced laser cooling into an application relevant regime and has put first practical optical cryocoolers within reach. The result is also relevant from a material perspective since for the first time, an Yb3+-doped crystal has outperformed an Yb3+-doped glass. The record temperature of 208 K was held by the Yb3+-doped fluorozirconate glass ZBLAN. Advanced purification and glass fabrication methods currently under development are expected to also advance ZBLAN:Yb3+ to sub-TEC temperatures. However, recent achievements with YLF:Yb3+ illustrate that crystalline materials may have two potentially game-changing advantajes over glassy materials. First, the crystalline environment reduces the inhomogeneous broadening of the Yb3+ electronic transitions as compared to a glassy matrix. The respective sharpening of the crystal-field transitions increases the peak absorption cross section at the laser excitation wavelength and allows for more efficient pumping of the Yb3+ ions, particularly at low temperatures. Second, many detrimental impurities present in the starting materials tend to be excluded from the crystal during its slow growth process, in contrast to a glass where all impurities present in the starting materials are included in the glass when it is formed by temperature quenching a melt. The ultra high purity required for laser cooling materials [PRB] therefore may be easier to realize in crystals than in glasses. Laser cooling occurs by laser excitation of a rare-earth ion followed by anti-Stokes luminescence. Each such laser-cooling cycle extracts thermal energy from the solid and carries it away as high-entropy light, thereby cooling the material. In the ideal case, the respective laser-cooling power is given by the pump wavelength ({lambda}{sub p}), the mean fluorescence wavelength ({bar {lambda}}{sub L}), and the absorption coefficient (a{sub r}) of the pumped transition. These quantities are solely determined by crystal field interactions. On one hand, a large crystal-field splitting offers a favorably large difference of {lambda}{sub p} - {bar {lambda}}{sub L} and thus a high cooling efficiency {eta}{sub cool} = ({lambda}{sub p} - {bar {lambda}}{sub L})/{bar {lambda}}{sub L}. On the other hand, a small crystal-field splitting offers a high thermal population (n{sub i}) of the initial state of the pumped transition, giving a high pump absorption coefficient and thus high laser cooling power, particularly at low temperatures. A quantitative description of crystal-field interactions is therefore critical to the understanding and optimization of optical refrigeration. In the case of Yb3+ as the laser cooling ion, however, development of a crystal-field model is met with substantial difficulties. First, Yb3+ has only two 4/multiplets, {sup 2}F{sub 7/2} and {sup 2}F{sub 5/2}, which lead to at most 7 crystal-field levels. This makes it difficult, and in some cases impossible, to evaluate the crystal-field Hamiltonian, which has at least 4 parameters for any Yb3+ point symmety lower than cubic. Second, {sup 2}F{sub 7/2}{leftrightarrow}{sup 2}F{sub 5/2} transitions exhibit an exceptionally strong electron-phonon coupling compared to 4f transitions of other rare earths. This makes it difficult to distinguish electronic from vibronic transitions in the absorption and luminescence spectra and to reliably identify the crystal-field levels. Yb3+ crystal-field splittings reported in the literature should thus generally be viewed with caution. This paper explores the effects of crystal-field interactions on the laser cooling performance of Yb3+-doped fluoride crystals. It is shown that the total crystal-field splitting of the {sup 2}F{sub 7/2} and {sup 2}F{sub 5/2} multiplets of Yb3+ can be estimated from crystal-field splittings of other rare-earth-doped fluoride crystals. This approach takes advantage of an extensive body of experimental work from which Yb3+ doped fluoride crystals with favorable laser cooling properties might be identified. Section 2 reviews the crystal-field splitting of the 4f electronic states and introduces the crystal-field strength as a means to predict the total crystal-field splitting of the {sup 2}F{sub 7/2} and {sup 2}F{sub 5/2} multiplets. Section 3 illustrates the effect of the total {sup 2}F{sub 7/2} crystal field splitting on the laser cooling power. Finally, Section 4 compiles literature data on crystal-field splittings in fluoride crystals from which the {sup 2}F{sub 7/2} splitting is predicted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗