Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost and performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Techno-economic Analysis of Novel PV Plant Designs for Extreme Cost Reductions

A techno-economic analysis is underway examining the cost and performance of future large-scale photovoltaic (PV) plant components, including bifacial modules, tandem modules, increased plant voltage architectures, and module-level power electronics. Integration of these components into PV plant designs is compared with current PV technologies based on levelized cost of electricity (LCOE). Baseline models are developed and validated against recorded PV plant performance data. Expected cost and performance data of future PV technologies are incorporated into the baseline models. An evolutionary algorithm is utilized to optimize PV plant configuration, technology combination, and LCOE. Furthermore, this paper focuses on the bifacial module analysis.

14 SOLAR ENERGY↗

Performance of an annual combustor designed for a low-cost turbojet engine

Performance tests were conducted on a combustor designed for use in a low-cost turbojet engine. Low-cost features included the use of very inexpensive simplex fuel nozzles and combustor liners of perforated sheet material. Combustion efficiencies at the altitude-cruise and sea-level design points were approximately 94 and 96 percent, respectively. The combustor isothermal total-pressure loss was 8.8 percent at the altitude-cruise-condition diffuser-inlet Mach number of 0.335. The combustor-exit temperature pattern factor was less than 0.3 at the altitude-cruise, sea-level-cruise, and sea-level-static design conditions. The combustor-exit average radial temperature profiles at all conditions were in very good agreement with the design profile. The intense mixing required because of the very high combustor heat-release rate had an adverse effect on ignition capability at altitude windmilling design conditions.

Fear, J. S.↗

Practical Techniques for Modeling Gas Turbine Engine Performance

The cost and risk associated with the design and operation of gas turbine engine systems has led to an increasing dependence on mathematical models. In this paper, the fundamentals of engine simulation will be reviewed, an example performance analysis will be performed, and relationships useful for engine control system development will be highlighted. The focus will be on thermodynamic modeling utilizing techniques common in industry, such as: the Brayton cycle, component performance maps, map scaling, and design point criteria generation. In general, these topics will be viewed from the standpoint of an example turbojet engine model; however, demonstrated concepts may be adapted to other gas turbine systems, such as gas generators, marine engines, or high bypass aircraft engines. The purpose of this paper is to provide an example of gas turbine model generation and system performance analysis for educational uses, such as curriculum creation or student reference.

aerothermodynamics↗

Practical Techniques for Modeling Gas Turbine Engine Performance

The cost and risk associated with the design and operation of gas turbine engine systems has led to an increasing dependence on mathematical models. In this paper, the fundamentals of engine simulation will be reviewed, an example performance analysis will be performed, and relationships useful for engine control system development will be highlighted. The focus will be on thermodynamic modeling utilizing techniques common in industry, such as: the Brayton cycle, component performance maps, map scaling, and design point criteria generation. In general, these topics will be viewed from the standpoint of an example turbojet engine model; however, demonstrated concepts may be adapted to other gas turbine systems, such as gas generators, marine engines, or high bypass aircraft engines. The purpose of this paper is to provide an example of gas turbine model generation and system performance analysis for educational uses, such as curriculum creation or student reference.

aerothermodynamics↗

Quality Guidelines for Energy System Studies: Capital Cost Scaling Methodology: Revision 4b Report

The National Energy Technology Laboratory (NETL) regularly updates legacy analysis with new studies and cases as the Department of Energy objectives change, technology performance improves, costs are reduced, regulations change, market drivers are established, fuel prices fluctuate, and any number of other relevant factors vary in the market. As legacy studies are updated by NETL, the underlying performance and cost of the cases presented changes, and as such, the methods for interpreting and scaling the cost estimates change. Therefore, it is important that NETL maintain public guidance documents associated with different sets of cost estimates that delineate how a specific set, based on report vintage and/or year published, should be scaled. This Quality Guidelines for Energy System Studies report, providing guidance on capital cost scaling, should generally be applied to NETL case costs included in the report “Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity Revision 4b,” (NETL, 2025) or any cases derived from the cases presented in the referenced report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technoeconomic Evaluation of Solid Oxide Fuel Cell Hydrogen-Electricity Co-Generation Concepts

This report evaluates the cost and performance of several types of Integrated Energy Systems (IES) based on solid oxide fuel cells (SOFCs) to generate power and solid oxide electrolysis cells (SOECs) to produce hydrogen. All cases feature carbon capture at rates exceeding 97 percent. The report also describes the development of optimized steady state process models for each system. These are used to calculate overall electricity and hydrogen production costs using a consistent methodology that facilitates comparisons of these cases to one another and to prior NETL cost and performance estimates. The SOFC and SOEC costs and performance are based on nth-of-a-kind systems and include research and development and learning associated with mass-scale commercial deployment of the technology over the next decade required for commercial utility-scale systems.

08 HYDROGEN↗

Cryogenic Performance of Trex SiC Mirror

Low cost, high performance lightweight Silicon Carbide (Sic) mirrors provide an alternative to Beryllium mirrors. A Trex Enterprises 0.25m diameter lightweight Sic mirror using its patented Chemical Vapor Composites (CVC) technology was evaluated for its optical performance. CVC Sic is chemically pure, thermally stable, and mechanically stiff. CVC technology yields higher growth rate than that of CVD Sic. NASA has funded lightweight optical materials technology development efforts involving Sic mirrors for future space based telescope programs. As part of these efforts, a Trex Sic was measured interferometrically from room temperature to 30 degrees Kelvin. This paper will discuss the test goals, the test instrumentation, test results, and lessons learned.

Foss, Colby↗

FLOW BATTERY COST AND COMMERCIALIZATION TOOL (FlowBaCC) v.1.0

The Flow Battery Cost and Commercialization Tool (FlowBaCC) is a python-based framework used to project the costs and commercialization timelines for redox flow batteries. FlowBaCC combines learning curves for component costs and performance with adoption curves for market diffusion to project future system costs. The tool uses the bottom-up, spreadsheet-based Battery Performance and Cost Model for Flow Batteries (BatPaC-Flow) as the engine to translate learning curve inputs into full system costs. FlowBaCC provides capital costs and levelized costs of energy storage. The tool enables scenario analysis, sensitivity analysis, and uncertainty quantification (via grid and Monte Carlo methods).

Fu, Xiaoxu [Argonne National Laboratory (ANL), Arg↗

Operational performance of a low cost, air mass 2 solar simulator

Modifications and improvements on a low cost air mass 2 solar simulator are discussed. The performance characteristics of total irradiance, uniformity of irradiance, spectral distribution, and beam subtense angle are presented. The simulator consists of an array of tungsten halogen lamps hexagonally spaced in a plane. A corresponding array of plastic Fresnel lenses shapes the output beam such that the simulator irradiates a 1.2 m by 1.2 m area with uniform collimated irradiance. Details are given concerning individual lamp output measurements and placement of the lamps. Originally, only the direct component of solar irradiance was simulated. Since the diffuse component may affect the performance of some collectors, the capability to simulate it is being added. An approach to this diffuse addition is discussed.

Yass, K.↗

An evaluation of differential Omega for general aviation area navigation

This paper reports on a study which compared the expected cost and performance of Differential Omega with that of Loran-C and VORTAC for general aviation area navigation. Analysis is directed toward a comparison of the systems with respect to specified performance parameters and the cost-effectiveness of each system in relation to the specifications. Loran-C offers the highest performance with respect to accuracy. Differential Omega requires the least expenditure. It was found cost ineffective to attempt to obtain complete coverage by expanding the existing VORTAC system.

Hollister, W. M.↗

Thermal Performance of a Low-Cost Loop Heat Pipe

This paper presents the thermal performance of a low-cost loop heat pipe (LHP) consisting of a single evaporator and a single condenser. The evaporator has an outer diameter of 14mm and a length of 50mm. An organic solvent was used as the working fluid. The low-cost LHP was made possible through a new manufacturing process. The LHP demonstrated excellent performance over heat loads ranging from 1W to 15OW and sink temperatures between 253K and 293K. Tests performed included start-up, power cycle, sink temperature cycle, high power and low power operations. No performance anomalies were seen.

Ku, Jentung↗

Operational performance of a low cost, air mass 2 solar simulator

The present work describes briefly the design, construction, and operation of a low cost air mass 2 solar simulator, and then presents the performance characteristics of a modified version in terms of total irradiance, uniformity of irradiance, spectral distribution, and beam subtense angle. The simulator consists of an array of 143 tungsten halogen lamps and a corresponding array of 143 Fresnel lenses parallel and in front of the lenses, so that a 1.2 m by 1.2 m area is irradiated with uniform collimated irradiance. The performance of this 143-lamp version is compared with that of the 12-lamp prototype. It was found that the larger design required a lower lamp voltage for an equivalent average total irradiance in the test plane. However, distribution of total irradiance was not as good for the large simulator.

Yass, K.↗

NETL's Carbon Capture Retrofit Databases

This PowerPoint presentation summarizes the recently published Carbon Capture Retrofit Databases and their supporting documents, such as user guides and studies used to inform cost and performance estimates. NETL publications used to develop slide contents include Cost of Capturing CO2 from Industrial Sources, 2022; Industrial CCRD, 2022; Eliminating the Derate of Carbon Capture Retrofits, 2023; PC CCRD, 2023; Cost and Performance of Retrofitting NGCC Units for Carbon Capture, 2023; and NGCC CCRD, 2023.

Hughes, Sydney↗

Cost analysis of water recovery systems

A methodology was developed to predict the relevant contributions of the more intangible cost elements encountered in the development of flight-qualified hardware based on an extrapolation of past hardware development experience. Major items of costs within water recovery systems were identified and related to physical and/or performance criteria. Cost and performance data from Gemini, Skylab, and other aerospace and biotechnology programs were analyzed to identify major cost elements required to establish cost estimating relationships for advanced water recovery systems. The results of the study are expected to assist NASA in long-range planning and allocation of resources in a cost effective manner in support of earth orbital programs. This report deals with the cost analysis of the five leading water reclamation systems, namely: (1) RITE waste management-water system, (2) reverse osmosis system, (3) multifiltration system, (4) vapor compression system, and (5) closed air evaporation system with electrolytic pretreatment.

Yakut, M. M.↗

Demonstration of Cost-Effective, High-Performance Computing at Performance and Reliability Levels Equivalent to a 1994 Vector Supercomputer

The Affordable High Performance Computing (AHPC) project demonstrated that high-performance computing based on a distributed network of computer workstations is a cost-effective alternative to vector supercomputers for running CPU and memory intensive design and analysis tools. The AHPC project created an integrated system called a Network Supercomputer. By connecting computer work-stations through a network and utilizing the workstations when they are idle, the resulting distributed-workstation environment has the same performance and reliability levels as the Cray C90 vector Supercomputer at less than 25 percent of the C90 cost. In fact, the cost comparison between a Cray C90 Supercomputer and Sun workstations showed that the number of distributed networked workstations equivalent to a C90 costs approximately 8 percent of the C90.

Babrauckas, Theresa↗

New component development for multi-100 kW low-cost solar array applications

Studies of the cost and performance of flexible arrays have shown that the most dramatic reductions in the $/Watt figure of merit are achieved by increasing performance. An examination of those properties that contribute to array performance indicated areas where radical changes in current design practice and philosophy would result in significant cost and performance impacts. To take advantage of the predicted cost reductions, modules were fabricated and tested that had ultra-thin superstrates as a load carrying member and large area dielectric wraparound (DWA), gridded back surface and copper contacted solar cells.

Pack, G. J.↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards a Multi-Variable Parametric Cost Model for Ground and Space Telescopes

Parametric cost models can be used by designers and project managers to perform relative cost comparisons between major architectural cost drivers and allow high-level design trades; enable cost-benefit analysis for technology development investment; and, provide a basis for estimating total project cost between related concepts. This paper hypothesizes a single model, based on published models and engineering intuition, for both ground and space telescopes: OTA Cost approximately (X) D(exp (1.75 +/- 0.05)) lambda(exp(-0.5 +/- 0.25) T(exp -0.25) e (exp (-0.04)Y). Specific findings include: space telescopes cost 50X to 100X more ground telescopes; diameter is the most important CER; cost is reduced by approximately 50% every 20 years (presumably because of technology advance and process improvements); and, for space telescopes, cost associated with wavelength performance is balanced by cost associated with operating temperature. Finally, duplication only reduces cost for the manufacture of identical systems (i.e. multiple aperture sparse arrays or interferometers). And, while duplication does reduce the cost of manufacturing the mirrors of segmented primary mirror, this cost savings does not appear to manifest itself in the final primary mirror assembly (presumably because the structure for a segmented mirror is more complicated than for a monolithic mirror).

Space Mirror Technology↗