Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Cooling performance of direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling

Providing fresh air to rooms can ensure indoor air quality. The direct expansion fresh air handling units are widely used, and most of them are single-stage treatment units, which are less energy-efficient under variable operating conditions. To overcome the shortcomings of existing systems, a direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling is proposed in this study. The fresh air is handled by coils stage by stage to achieve high efficiency, and the dampers of the idle coils are opened when some of the coils are working, which results in the performance improvement under partial load conditions. The simulation model is established, and operating conditions at load ratio of 95.70%, 45.38%, 31.76% and 0 are selected as typical operating conditions. The proposed system performances under different conditions are compared with traditional system. The results show that: (1) For four conditions, as the load rate decreases, the proposed system can save energy by 6.2%, 26.1%, 46.5%, and 25.0% compared to the traditional system respectively; (2) The proposed system can bypass the filter when the outdoor air is good, which can further save energy by 1.3%, 1.8%, 3.4%, and 25.9% under four conditions, respectively.

Zha, Fuhai↗

Performance study of charcoal-based radon reduction systems for ultraclean rare event detectors

The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. 222 Rn produces a particularly problematic background in the physics region of interest by the "naked" beta decay of its 214 Pb daughter nucleus. While charcoal-based adsorption traps are expected to be effective for radon reduction in auxiliary circulation loops that service the warm components of current ton-scale detectors at slow flow rates (0.5-2 SLPM), radon reduction in the entire circulation loop at high flow rates $\mathcal{O}$(100s SLPM) is necessary to reach high sensitivity in future generation experiments. In this article we explore radon dynamics with a charcoal-based radon reduction system in the main circulation loop of time projection chamber detectors. Here, we find that even for perfect radon traps, circulation speeds of 2,000 SLPM are needed to reduce radon concentration in a 10 ton detector by 90%. This is faster by a factor of four than the highest circulation speeds currently achieved in dark matter detectors. We further find that the effectiveness of vacuum swing adsorption systems, which have been employed very successfully at reducing atmospheric radon levels in clean-rooms, is limited by the intrinsic radon activity of the charcoal adsorbent in ultra-low radon environments. Adsorbents with significantly lower intrinsic radon activity than in currently available activated charcoals would be necessary to build effective vacuum swing adsorption systems operated at room temperature for rare event search experiments. If such VSA systems are cooled to about 190 K, this requirement relaxes drastically.

47 OTHER INSTRUMENTATION↗

Structural and thermodynamic characterization of CuZr metallic glass nanoparticles: Insights from atomistic simulations

Metallic crystalline nanoparticles (NPs) have been shown to display intriguing size-dependent properties. However, the properties of metallic glass (MG) NPs remain largely unexplored. Here, using molecular dynamics simulations, we produce Cu 64 Zr 36 MG NPs ranging in size from 1 to 20 nm by cooling molten systems at a relatively slow rate of 10 9 K/s. Results indicate that NPs are coated with a Cu-rich layer with a thickness that increases with NP size. We employ various simulated rates of heating, from 10 11 to 10 13 K/s, to determine the melting points of these NPs. The results show a significant decrease in the solidus temperature for NPs smaller than 10 nm. Furthermore, as NP size decreases, the fraction of Cu full icosahedra within the NPs increases, suggesting that smaller NPs are stronger and harder. These findings provide insights for designing heterogeneous metallic nanoglass materials that leverage the size-dependent properties of MG NPs.

36 MATERIALS SCIENCE↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Physically-based control-oriented modeling for turbocharged stoichiometric spark-ignited engine with cooled EGR and flexible VVT systems

Accurate estimation and prediction of engine gas exchange system and in-cylinder conditions are critical for spark-ignited engine control and diagnostic algorithm development. In this paper, a physically-based, control-oriented model for a 2.8 l turbocharged, variable valve timing (VVT) and low pressure (LP) exhaust gas recirculation (EGR)-utilizing SI engine was developed. The model includes the impact of modulation to any combination of 10 actuators, including the throttle valve, compressor bypass valve, fueling rate, waste-gate, LP EGR valve, number of deactivated cylinders, intake valve open (IVO) timing, intake valve close (IVC) timing, exhaust valve open (EVO) timing and exhaust valve close (EVC) timing. The accuracy of the model in capturing engine dynamics was demonstrated by validating it against high-fidelity engine GT-Power simulation results for various drive cycles, particularly emphasizing elevated loads. In comparison to the open literature, novel contributions of the effort described in this paper includes in-cylinder gas composition modeling and turbine-out pressure estimation.

Zhang, Xu↗

RELAP-7 Application and Enhancement for FLEX Strategies and ATF Behavior under Extended Loss of AC Power Conditions

This report summarizes the results of a three-year research project sponsored by the U.S. Department of Energy (DOE) Nuclear Energy University Program (NEUP) to enhance and apply the RELAP-7 code by adding and improving several important components (e.g., a mechanistic Reactor Core Isolation Cooling (RCIC) system model) for thermal hydraulic studies of LWRs under ELAP conditions and evaluating the time available for transition to portable FLEX equipment. The project team included University of Massachusetts–Lowell, The Ohio State University, Texas A&M University, Idaho National Laboratory and Oak Ridge National Laboratory. In the Fukushima accident, it was found that the RCIC system played a crucial role in delaying core meltdown by almost three days in Fukushima Daiichi Unit 2, because of self-regulated operation of the steam driven RCIC turbine-pump injection system. Steam flow in the convergent-divergent nozzles of the RCIC Terry turbine is two-phase non-equilibrium transonic flow with homogenous nucleation condensation. To more accurately predict the dynamic process and behavior of the transonic compressible steam flow, a one-dimensional transient two-phase analytical model is presented. A simplified four-fluid model was employed in the present work with the consideration of four separate fluid fields: vapor, liquid film, entrained droplets and condensed droplets. The mass, momentum and energy interactions between the fluids were considered and modeled. An extended seven-equation non-equilibrium critical flow model was developed to obtain the critical pressure and velocities of each phase at the nozzle throat. To predict the wetness in the divergent section, a mechanistic nucleation condensation model was integrated in the nozzle analysis model, considering the generation and consequent growth of droplets. The governing differential equations on a staggered grid were discretized using the second-order Lax-Wendroff scheme with a flux limiter, and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE) algorithm was employed to solve the discrete linear system. To demonstrate the predictability and reliability of the physical models and the numerical method proposed in the present work, three representative nozzles were modeled and simulated. The results show good agreement with the available experimental data, even for condensation shock. Then, the 1D nozzle model was employed to obtain nozzle flow tables of the Terry turbine nozzle for different working pressures which can cover the operation pressure range of the RCIC system. A mechanistic RCIC turbine-pump system model was developed and implemented in the system code TRACE to simulate dynamic responses of the RCIC system under Beyond Design Basis Accident (BDBA) conditions. The turbine-pump governing equations are based on the control volume approach of the angular momentum balance. The physics based mechanistic RCIC model was developed using the TRACE control system components (i.e., signal variables, control blocks, and tables), and incorporated into a TRACE boiling water reactor (BWR) model. The TRACE model in this report has a detailed nodalization of the reactor pressure vessel (RPV), and all of the major flow paths and system components, including the safety relief valves (SRVs) and the containment suppression pool and drywell. Based on the nozzle flow tables generated from the 1D nozzle model developed, the turbine drive torque can be calculated from table lookup. Since the detailed specifications of the RCIC pump are unavailable, the homologous curves for a Bingham pump were used in the current pump component. A station black-out (SBO) accident test problem was selected to demonstrate the TRACE RCIC model. The short-term SBO simulations were performed for two cladding materials: Zircaloy and FeCrAl, to demonstrate the effect of the accident tolerant fuel cladding on fuel heat-up under BDBA accident conditions. The wetwell plays a vital safety role in SBO and other BWR accident scenarios in that it can reduce containment pressure and supply additional core make-up water. The suppression pool temperature distribution has a very large impact on both RPV and containment pressure. Thus, another novel contribution of the project comes mainly from an improved, systems-level wetwell model which can capture buoyancy-induced thermal stratification effects due to steam injection and condensation. A two-zone stratified wetwell model has been implemented in RELAP-7 and some results from that model are presented. This wetwell model is capable of simulating thermal stratification due to a low steam mass injection rate. With a low mass flow rate, the model assumes that all the steam condenses within the pipe and the resulting plume can be approximated with a purely buoyant, heat-source driven model. The wetwell model developed with these assumptions is adequate to simulate slow transients such as extended SBO transients.

42 ENGINEERING↗

Performance Improvements for the Griffin Transport Solvers

Griffin is a Multiphysics Object-Oriented Simulation Environment based reactor multiphysics analysis application jointly developed by Idaho National Laboratory and Argonne National Laboratory. Griffin includes a variety of deterministic radiation transport solvers for fixed source, k-eigenvalue, adjoint, and subcritical multiplication, as well as transient solvers for point-kinetics, improved quasi-static, and spatial dynamics. A code assessment performed in FY-20 identified two significant issues with the transport solvers in Griffin: first, the primary heterogeneous SN (discrete ordinates) transport solver based on continuous finite element methods required significant mesh refinement and higher memory usage compared to solvers based on the method of characteristic for equivalent accuracy. Second, the homogeneous PN (spherical harmonics expansion) transport solver did not adequately support polynomial refinement, which is a feature usually required for problems with spatial homogenization and pronounced streaming, typical in fast or gas-cooled reactor systems. To address the first issue, the development effort focused on the more promising discontinuous finite element method (DFEM)-based SN transport solver in Griffin. The addition of an asynchronous parallel transport sweeper and coarse mesh finite difference (CMFD) acceleration have rendered a superior heterogeneous SN transport capability for multiphysics problems that requires far less computing resources in terms of both CPU time and memory usage. This is demonstrated with typical thermal- and fast-spectrum reactor benchmark problems, including 2D Transient Reactor Test, 3D Advanced Burner Test Reactor (ABTR), and 2D and 3D Empire microreactor. For the second issue, the development effort focused on a new transport solver based on the hybrid finite element PN method (HFEM-PN), equivalent to the variational nodal method, as well as a new diffusion solver based on HFEM-Diffusion. This solver is intended for homogenized domains with multiphysics coupling (i.e., supports mesh displacement, seamless temperature feedback, etc.). Initial calculations with the HFEM-Diffusion implementation show very good parallel efficiency for the residual evaluations with the 2D ABTR benchmark. A future development effort will be centered on further improvements to the CMFD, HFEM-PN, and DFEM diffusion solvers to ensure Griffin meets performance and software quality assurance requirements for advanced reactor design and analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Thermal Management of Wide-Bandgap Semiconductor Amplifiers Used for Plasma Heating and Control

Princeton Fusion Systems (PFS) has designed, built, and tested a Load Switch printed circuit board (PCB) to demonstrate the capabilities of 2 kV silicon carbide (SiC) cascodes in development by Qorvo towards plasma heating and control applications. Initial tests have been conducted at low power (~100 W) for validation with thermal finite element analysis (FEA) modeling performed by the National Renewable Energy Laboratory (NREL). Comparisons of experimental data with the thermal modeling results, along with considerations for operating in plasma systems, will be discussed.

CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SU↗

Rewarding Grid-Friendly Behavior: Estimating the Potential Bill Reduction and Load Shifting Benefits of Dynamic Prices

Shifting electric load from times of peak demand can be a key strategy to slow price growth as reducing peak demand avoids the cost of upgrading generation, transmission and distribution infrastructure. Utilities are releasing time-varying prices, such as time of use rates or dynamic prices, to incentivize grid-friendly load shifting. New dynamic price programs provide insight into the true cost of operating electricity grids and the potential economic benefits of load shifting. Program developers and device manufacturers need to understand the economic opportunities in terms of 1) the variation in prices across hours, days, and seasons; 2) the change in utility bills for customers who don’t shift load; and 3) the potential load shifted and economic value of different technologies if manufacturers or aggregators deploy price-responsive controls. This paper estimates possible impacts of dynamic price adoption and load shifting controls if customers paid the dynamic rate from one pilot program. Statistical analysis of historical prices identified annual and seasonal metrics as well as representative price curves for each circuit in the pilot. Simulations for residential technologies with price-responsive controls including unitary heat pump water heaters, central multifamily heat pump water heaters, heating & cooling + storage systems, and pool pumps estimated the potential impacts of highly dynamic prices both with and without load shifting controls. Results showed the potential to reduce electricity costs on representative days by 42-94% and reduce consumption during times of high electricity prices by 63-100% compared to baseline operation for those flex-friendly devices.

Grant, Peter↗

Non-destructive, in-situ evaluation of water presence using thermal contrast and cooled detector

Exemplary systems for detecting water include: a light source positioned to transmit thermal radiation through a sample; a lens assembly positioned to: receive the thermal radiation transmitted through the sample; and focus the transmitted thermal radiation onto a filter positioned between the lens assembly and a detector; and a cooling subsystem for cooling the filter and the detector to a temperature below that of the sample. The filter (1) selectively transmits first portions of the thermal radiation received from the lens assembly and characterized by a wavelength at least partially overlapping a predefined water absorption band and/or a predefined water absorption line; and (2) selectively blocks second portions of the thermal radiation received from the lens assembly and characterized by a wavelength outside the predefined water absorption band and/or the predefined water absorption line. Methods for detecting presence of water in a sample are also disclosed.

Bora, Mihail↗

Non-destructive, in-situ evaluation of water presence using thermal contrast and cooled detector

Exemplary systems for detecting water include: a light source positioned to transmit thermal radiation through a sample; a lens assembly positioned to: receive the thermal radiation transmitted through the sample; and focus the transmitted thermal radiation onto a filter positioned between the lens assembly and a detector; and a cooling subsystem for cooling the filter and the detector to a temperature below that of the sample. Methods for detecting presence of water in a sample are also disclosed.

47 OTHER INSTRUMENTATION↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Nuclear—thermal energy storage configurations for industrial combined heat and power supply—conceptual and thermodynamic study with high temperature gas-cooled reactor

Nuclear systems are promising candidates for delivering resilient heat and power for future energy security and independence. Traditionally, nuclear plants have been used for baseload electricity production and cogeneration of heat has seen relatively limited application utilizing typically only small portion of a reactor's thermal output. This paradigm may shift due to the increasing penetration of intermittent renewables and need for resource flexibility, various decarbonization efforts aimed at both electricity and heat demands, along with the perspective of small modular nuclear reactor applications, which can be sized based on local industrial needs. Here, this study provides a comprehensive guide for the nuclear and industrial sectors, emphasizing controllability in the combined heat and power configuration options for high temperature gas-cooled reactor and process steam supply. It investigates the integration of thermal energy storage to improve nuclear energy's responsiveness to varying industrial demands. The study emphasizes placing thermal energy storage between the nuclear primary loop and steam cycle to achieve greater efficiency and flexibility in power and heat output, surpassing traditional combined heat and power systems and avoiding efficiency losses seen in other thermal energy storage integration approaches.

combined heat and power (CHP)↗

Benchmark Simulation of the Natural Convection Shutdown Heat Removal Test Facility Using SAM

Natural convection systems are a promising method to passively remove heat from reactor cavities during loss of forced flow accident scenarios. In this work at Argonne National Laboratory (ANL), a highly instrumented Natural Convection Shutdown Heat Removal Test Facility (NSTF) was used to demonstrate the effectiveness of air-cooled natural convection systems. In previous work, RELAP5-3D simulations were performed on this facility with favorable comparisons to experiment for mass flow rate, pressure drop, air temperature increase, and air velocity. Both experimental and simulation efforts with this facility present a useful opportunity to perform a benchmark study with the System Analysis Module (SAM). SAM is an advanced thermal-hydraulic system code currently in development at ANL for advanced non-light water reactor safety analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multi-Physics System-level Simulations of a Generic Pebble Bed High-Temperature Gas Cooled Reactor with Coupled SAM/Griffin Model

A SAM model for a 200 MWth generic pebble bed high-temperature gas-cooled reactor (PBHTGR) is presented in this work. As an extension to the modeling effort from FY-22 (Ooi et al. (2022)), an improved core channel approach is used to model the pebble bed of the reactor. The improvement greatly simplifies the model and reduces the run time of the model. Furthermore, the SAM model is coupled to the Griffin reactor physics model from Stewart et al. (2021) using the MOOSE MultiApp system where neutronics calculations are performed by the Griffin model and thermal hydraulics calculations by the SAM model. Favorable predictions are produced by the SAM/Griffin coupled model for steady-state normal operating condition. A load-following transient is also simulated with the coupled model where the neutronics and thermal hydraulics responses of the core are predicted correctly by the model. A protected Pressurized Loss of Forced Cooling (PLOFC) accident is simulated with the SAM model, in which the reactor power is determined using the decay heat curve, and therefore the Griffin model is not needed and thus decoupled. A simplified RCCS (Reactor Cavity Cooling System) loop is added to the model to remove decay heat from the core during the transient. Qualitatively, the prediction by the SAM model matches the expected behavior of a PB-HTGR during a PLOFC accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗