Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Effect of endwall cooling on secondary flows in turbine stator vanes

The effect of endwall cooling on the secondary flow behavior and the aerodynamic performance of a core turbine stator vane was determined. The investigation was conducted in a cold-air, full-annular cascade, where three-dimensional effects were obtained. Two endwall cooling configurations were tested. In the first configuration, the cooling holes were oriented so that the coolant was injected in line with the inviscid streamline direction. In the second configuration, the coolant was injected at an angle of 15 deg to the inviscid streamline direction and oriented towards the vane pressure stator. In both cases the stator vanes were solid and uncooled so that the effect of endwall cooling was obtained directly. Total-pressure surveys were taken downstream of the stator vanes over a range of cooling flows at the design, mean-radius, critical velocity ratio of 0.778. Changes in the total-pressure contours downstream of the vanes were used to obtain the effect of endwall cooling on the secondary flows in the stator.

Goldman, L. J.↗

Measured performance of a 3-ton LiBr absorption water chiller and its effect on cooling system operation

A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Site dependent factors affecting the economic feasibility of solar powered absorption cooling

A procedure was developed to evaluate the cost effectiveness of combining an absorption cycle chiller with a solar energy system. A basic assumption of the procedure is that a solar energy system exists for meeting the heating load of the building, and that the building must be cooled. The decision to be made is to either cool the building with a conventional vapor compression cycle chiller or to use the existing solar energy system to provide a heat input to the absorption chiller. Two methods of meeting the cooling load not supplied by solar energy were considered. In the first method, heat is supplied to the absorption chiller by a boiler using fossil fuel. In the second method, the load not met by solar energy is net by a conventional vapor compression chiller. In addition, the procedure can consider waste heat as another form of auxiliary energy. Commercial applications of solar cooling with an absorption chiller were found to be more cost effective than the residential applications. In general, it was found that the larger the chiller, the more economically feasible it would be. Also, it was found that a conventional vapor compression chiller is a viable alternative for the auxiliary cooling source, especially for the larger chillers. The results of the analysis gives a relative rating of the sites considered as to their economic feasibility of solar cooling.

Bartlett, J. C.↗

Cooling rates of group IVA iron meteorites

Cooling rates of six group IVA iron meteorites were estimated by a taenite central Ni concentration-taenite half-width method. Calculated cooling rates range from 13 to 25 C/Myr, with an average of 20 C/Myr. No correlation between cooling rate and bulk Ni content is observed, and the data appear to be consistent with a uniform cooling rate as expected from an igneous core origin. This result differs from previous studies reporting a wide range in cooling rates that were strongly correlated with bulk Ni content. The differences result mainly from differences in the phase diagram and the selected diffusion coefficients. Cooling rates inferred from taenite Ni concentrations at the interface with kamacite are consistent with those based on taenite central Ni content.

Willis, J.↗

Experimental modeling of the cooling history of Apollo 12 olivine basalts

An analog of the Apollo 12 olivine vitrophyres has been crystallized in a 1-atm gas-mixing furnace at cooling rates ranging between 1250 and 0.7 C/hr and isothermally at degrees of supercooling ranging from 10 C to 325 C. Mineral chemistry, crystal shapes, grain sizes and textures are systematically related to cooling rate and degree of supercooling. At linear cooling rates not exceeding 40 C/hr the texture is porphyritic - large olivine crystals are set in a groundmass of finer-grained pyroxene, plagioclase, and ilmenite; a later generation of olivine never crystallizes. There are three shapes of olivine crystals in the Apollo 12 olivine vitrophyres: glomerocrysts of subhedral crystals, large subequant skeletons, and highly elongate skeletons. These result from three generations of nucleation and a two-stage cooling history - a slow preeruption stage and a rapid continuously increasing posteruption stage. It seems likely that the Apollo 12 olivine basalt magmas were erupted with olivine crystals in suspension. The nucleation temperature of olivine in cooling-rate experiments is dependent on the experimental technique, and hence results of cooling experiments should be applied with caution.

Donaldson, C. H.↗

Effect of shocks on film cooling of a full scale turbojet exhaust nozzle having an external expansion surface

Cooling is one of the critical technologies for efficient design of exhaust nozzles, especially for the developing technology of nonaxisymmetric (2D) nozzles for future aircraft applications. Several promising 2D nozzle designs have external expansion surfaces which need to be cooled. Engine data are scarce, however, on nozzle cooling effectiveness in the supersonic flow environment (with shocks) that exists along external expansion surfaces. This paper will present experimental film cooling data obtained during exploratory testing with an axisymmetric plug nozzle having external expansion and installed on an afterburning turbojet engine in an altitude test facility. The data obtained shows that the shocks and local hot gas stream conditions have a marked effect on film cooling effectiveness. An existing film cooling correlation is adequate at some operating conditions but inadequate at other conditions such as in separated flow regions resulting from shock-boundary-layer interactions.

Straight, D. M.↗

Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling

The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.

Greenleaf, J. E.↗

Solidification zoning and metallographic cooling rates of chondrites

The cooling rates of chondrites have been determined according to the cooling rate method of Wood (1967) which involves the measurement of the concentration of nickel in the interiors of taenite grains of various sizes. The present paper presents an investigation of the effect of zoning produced during solidification on the use of the Wood method. Cooling rate curves were obtained in a computer simulation based on a model of kamacite formation on the outer edge of a taenite sphere of uniform initial composition, followed by the inward radial progression of the kamacite-taenite interface. When a concentration gradient produced by solidification is present in the initial conditions, deviations from the cooling rate curves for uniform 10% Ni are obtained only at cooling rates greater than 1000 K/million years, which would result in an overestimation of the cooling rates based on observed Ni gradients in grains of radius greater than 20 microns.

Willis, J.↗

Flight test method for the determination of reciprocating engine cooling requirements

It is pointed out that the effective cooling of aircraft reciprocating engines is still a problem area for the general aviation industry. Miley et al. (1981) have reported the results of an investigation of problems associated with cooling and installation aerodynamics. A description is given of a flight test procedure which was developed in connection with the considered investigation. It is shown that the test procedure provides valid cooling requirements data for a particular installation. The data are in terms of easily measurable parameters. The employment of the test procedure, which is based on the NACA cooling correlation method, can lead to more effective cooling installations and the solution of existing cooling problems.

Miley, S. J.↗

Investigation of a para-ortho hydrogen reactor for application to spacecraft sensor cooling

The utilization of solid hydrogen in space for sensor and instrument cooling is a very efficient technique for long term cooling or for cooling at high heat rates. The solid hydrogen can provide temperatures as low as 7 to 8 K to instruments. Vapor cooling is utilized to reduce parasitic heat inputs to the 7 to 8 K stage and is effective in providing intermediate cooling for instrument components operating at higher temperatures. The use of solid hydrogen in place of helium may lead to weight reductions as large as a factor of ten and an attendent reduction in system volume. The results of an investigation of a catalytic reactor for use with a solid hydrogen cooling system is presented. Trade studies were performed on several configurations of reactor to meet the requirements of high reactor efficiency with low pressure drop. Results for the selected reactor design are presented for both liquid hydrogen systems operating at near atmospheric pressure and the solid hydrogen cooler operating as low as 1 torr.

Nast, T. C.↗

Review and status of heat-transfer technology for internal passages of air-cooled turbine blades

Selected literature on heat-transfer and pressure losses for airflow through passages for several cooling methods generally applicable to gas turbine blades is reviewed. Some useful correlating equations are highlighted. The status of turbine-blade internal air-cooling technology for both nonrotating and rotating blades is discussed and the areas where further research is needed are indicated. The cooling methods considered include convection cooling in passages, impingement cooling at the leading edge and at the midchord, and convection cooling in passages, augmented by pin fins and the use of roughened internal walls.

Yeh, F. C.↗

Cooling flows in clusters of galaxies

Cooling gas in the center of many clusters of galaxies is compressed and pushed inward by the thermal pressure of the hot, uncooled outer gas. Gravity acts as a focusing agent until the gas has cooled to galactic temperatures. The cooling process is thermally unstable, giving rise to optical filamentation. Once the gas cools below 10.000 K it presumably forms stars which add to the mass of a central galaxy. Accretion rates of up to 400 solar masses/yr are inferred from X-ray measurements so that the mass of such central galaxies may be due to cooling flows. Their optical and UV appearance emphasize that the gas predominantly turns into low-mass stars with an initial mass function unlike that of the solar neighborhood. Optical and X-ray observations of cooling flows can be used to investigate the continuing formation of the largest known galaxies.

Fabian, A. C.↗

Highly ionized atoms in cooling gas

The ionization of low density gas cooling from a high temperature was calculated. The evolution during the cooling is assumed to be isochoric, isobaric, or a combination of these cases. The calculations are used to predict the column densities and ultraviolet line luminosities of highly ionized atoms in cooling gas. In a model for cooling of a hot galactic corona, it is shown that the observed value of N(N V) can be produced in the cooling gas, while the predicted value of N(Si IV) falls short of the observed value by a factor of about 5. The same model predicts fluxes of ultraviolet emission lines that are a factor of 10 lower than the claimed detections of Feldman, Brune, and Henry. Predictions are made for ultraviolet lines in cooling flows in early-type galaxies and clusters of galaxies. It is shown that the column densities of interest vary over a fairly narrow range, while the emission line luminosities are simply proportional to the mass inflow rate.

Edgar, R. J.↗

Free boundary shape of a convectively cooled solidified region

The two-dimensional steady-state shape of a solidified region, such as a frost layer, was determined analytically for formation on a plate that is convectively cooled. The nonuniform shape of the layer is produced by exposure to a spatially nonuniform distribution of radiant energy. For high convective cooling the cooled wall approaches a uniform temperature, and an exact solution is obtained for the free boundary shape. For a lesser amount of convective cooling, the variation in temperature along the cooled boundary is treated by a boundary perturbation method. Some illustrative examples are given that show the effects of nonuniform heating and the magnitude of convective heat transfer at the cooled wall. Only one boundary condition is approximated by the perturbation solution; all of the other boundary conditions are satisfied exactly. The calculated results given here were found to satisfy the approximate boundary condition within a very small error.

Siegel, R.↗

Highly ionized atoms in cooling gas

The ionization of low density gas cooling from a high temperature was calculated. The evolution during the cooling is assumed to be isochoric, isobaric, or a combination of these cases. The calculations are used to predict the column densities and ultraviolet line luminosities of highly ionized atoms in cooling gas. In a model for cooling of a hot galactic corona, it is shown that the observed value of N(N V) can be produced in the cooling gas, while the predicted value of N(Si IV) falls short of the observed value by a factor of about 5. The same model predicts fluxes of ultraviolet emission lines that are a factor of 10 lower than the claimed detections of Feldman, Bruna, and Henry. Predictions are made for ultraviolet lines in cooling flows in early-type galaxies and clusters of galaxies. It is shown that the column densities of interest vary over a fairly narrow range, while the emission line luminosities are simply proportional to the mass inflow rate.

Edgar, Richard J.↗

Transient radiative cooling of a layer filled with solidifying drops

An analysis is carried out for radiative cooling of a plane layer initially filled with liquid drops that solidify and then continue to cool by loss of sensible heat. This is in connection with a proposed lightweight radiator system for heat dissipation in space. Hot liquid drops would be ejected and then cooled by direct exposure in space; they would then pass into a collector for reuse. The cooling analysis contains three transient zones. In the first, the drops cool by losing latent heat until the outermost drops become solid. Then the cooling continues by loss of both latent and sensible heat. A similarity behavior is eventually achieved in which the transient emittance of the layer depends only on the optical thickness.

Siegel, R.↗

Transpiration And Regenerative Cooling Of Rocket Engine

Transpiration cooling extends limits of performance. Addition of transpiration cooling to regeneratively-cooled rocket-engine combustion chamber proposed. Modification improves performance of engine by allowing use of higher chamber pressure. Throat section of combustion-chamber wall cooled by transpiration, while chamber and nozzle sections cooled by fluid flowing in closed channels. Concept applicable to advanced, high-performance terrestrial engines or some kinds of industrial combustion chambers. With proper design, cooling scheme makes possible to achieve higher chamber pressure and higher overall performance in smaller engine.

Obrien, Charles J.↗

Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

Lagen, Nicholas T.↗