Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Enhancement of the contrast ratio associated with surface waves in a metal pillar-slit structure

A simple optical structure, termed a pillar-slit structure, is proposed to enhance the contrast ratio of the weak optical signal. The structure consists of a metal slit surrounded by two metal pillars and can be directly incorporated onto optical sensors. The waves excited on the incident surface are modulated by the pillars and then scattered by the slit entrance so as to generate the in-slit surface plasmon polaritons passing through the slit. The transmission power is modified by the surface wave intensity. This structure is capable of suppressing background and enhancing signal light simultaneously. A calculated illustration by the numerical simulation method shows that an increase of the contrast ratio can be exceeded 900 times.

36 MATERIALS SCIENCE↗

Simulating contrast inversion in atomic force microscopy imaging with real-space pseudopotentials

Atomic force microscopy (AFM) measurements have reported contrast inversions for systems such as Cu 2 N and graphene that can hamper image interpretation and characterization. In this work, we apply a simulation method based on ab initio real-space pseudopotentials to gain an understanding of the tip-sample interactions that influence the inversion. We find that chemically reactive tips induce an attractive binding force that results in the contrast inversion. We find that the inversion is tip height dependent and not observed when using less reactive CO-functionalized tips.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Greater than Five-Order-of-Magnitude Postcompression Temporal Contrast Improvement with an Ionization Plasma Grating

High-intensity lasers require suppression of prepulses and other nonideal temporal structure to avoid target disruption before the arrival of the main pulse. Here, to address this, we demonstrate that ionization gratings act as a controllable optical switch for high-power light with a temporal contrast improvement of at least 3 ×10 5 and a switching time less than 500 fs. We also show that a grating system can run for hours at 10 Hz without degradation. The contrast improvement from an ionization grating compares favorably to that achievable with plasma mirrors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge state dynamics and optically detected electron spin resonance contrast of shallow nitrogen-vacancy centers in diamond

Nitrogen-vacancy (NV) centers in diamond can be used for nanoscale sensing with atomic resolution and sensitivity; however, it has been observed that their properties degrade as they approach the diamond surface. Here we report that in addition to degraded spin coherence, NV centers within nanometers of the surface can also exhibit decreased fluorescence contrast for optically detected electron spin resonance (OD-ESR). We demonstrate that this decreased OD-ESR contrast arises from charge state dynamics of the NV center, and that it is strongly surface-dependent, indicating that surface engineering will be critical for nanoscale sensing applications based on color centers in diamond.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Contrasting decays of 3-quasiparticle isomers in 173 W: A discerning test of 𝐾 conservation and 𝐾 mixing

Two isomers with K π = 19/2 + at 1876 keV with a half-life of 21(1) ns, and K π = 23/2− at 2159 keV with a half-life of 93(6) ns have been identified in 173 W, the lightest tungsten isotope to exhibit this phenomenon. An unusually high number of 13 branches have been established in the decay of the K π = 23/2 − isomer. This decay is associated with transitions involving significantly higher degrees of K forbiddenness and is in sharp contrast with the usual preferential deexcitation through branches, which are less forbidden, as is evident for the K π = 19/2 + state in 173 W. The inclusion of K-mixing effects, arising from band crossings in the sequences to which decays with larger degrees of K forbiddenness are observed, can qualitatively account for this contrasting behavior. These results provide a striking illustration of the competition between K conservation and K mixing in the decay of such isomers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analyzer-based X-ray phase contrast imaging using the forward-diffracted o-beam in a few-millimetre-thick Bragg-case asymmetrically cut crystal

An analyzer-based X-ray phase contrast imaging experiment employing the forward-diffracted o-beam in a few-millimetre-thick Bragg-case asymmetrically cut analyzer crystal has been implemented and tested in a geometry similar to that used in conventional radiography. The high angular stability requirements were overcome using specially designed crystals and a closed-loop feedback intensity system, monitoring the intensity of the diffracted h-beam. Analyzer-based images (ABis) taken at different angular positions on the forward-diffracted o-beam rocking curve show different contrasts, as expected. However, the ABis did not show sharp borders. This was closely investigated by X-ray topography and Δ d / d mapping and was attributed to the stresses caused by the analyzer crystal's own weight in the bulk. Further investigation of the crystal design using finite element analysis coupled with dynamical theory of X-ray diffraction is envisaged.

Honnicke, Marcelo Goncalves (ORCID:000000033276432↗

Accurate contrast determination for X-ray speckle visibility spectroscopy

X-ray speckle visibility spectroscopy using X-ray free-electron lasers has long been proposed as a probe of fast dynamics in noncrystalline materials. In this paper, numerical modeling is presented to show how the data interpretation of visibility spectroscopy can be impacted by the nonidealities of real-life X-ray detectors. Using simulated detector data, this work provides a detailed analysis of the systematic errors of several contrast extraction algorithms in the context of low-count-rate X-ray speckle visibility spectroscopy and their origins are discussed. Here, it was found that the finite detector charge cloud and pixel size lead to an unavoidable `degeneracy' in photon position determination, and that the contrasts extracted using different algorithms can all be corrected by a simple linear model. The results suggest that experimental calibration of the correction coefficient at the count rate of interest is possible and essential. This allows computationally lightweight algorithms to be implemented for on-the-fly analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Contrasting patterns of sequence variation in steelhead populations reflect distinct evolutionary processes

Abstract Multiple evolutionary processes influence genome‐wide allele frequencies and quantifying effects of genetic drift, and multiple forms of selection remain challenging in natural populations. Here, we investigate variation at major effect loci in contrast to patterns of neutral drift across a wide collection of steelhead ( Oncorhynchus mykiss ) populations that have declined in abundance due to anthropogenic impacts. Whole‐genome resequencing of 74 populations of steelhead revealed genome‐wide patterns (~8 million SNPs) consistent with expected neutral population structure. However, allelic variation at major effect loci associated with adult migration timing (chromosome 28: GREB1L / ROCK1 ) and age at maturity (chromosome 25: SIX6 ) reflected how selection has acted on phenotypic variation in contrast with neutral structure. Variation at major effect loci was influenced by evolutionary processes with differing signals between the strongly divergent Coastal and Inland lineages, while allele frequencies within and among populations within the Inland lineage have been driven by local natural selection as well as recent anthropogenic influences. Recent anthropogenic effects appeared to have influenced the frequency of major effect alleles including artificial selection for specific traits in hatchery stocks with subsequent gene flow into natural populations. Selection from environmental factors at various scales has also likely influenced variation for major effect alleles. These results reveal evolutionary mechanisms that influence allele frequencies at major effect loci that are critical for conservation of phenotypic traits and life history variation of this protected species.

Willis, Stuart↗

X-ray computed tomography to predict soil N 2 O production via bacterial denitrification and N 2 O emission in contrasting bioenergy cropping systems

While renewable biofuels can reduce negative effects of fossil fuel energy consumption, the magnitude of their benefits depends on the magnitude of N 2 O emissions. High variability of N 2 O emissions overpowers efforts to curb uncertainties in estimating N 2 O fluxes from biofuel systems. In this study, we explored (a) N 2 O production via bacterial denitrification and (b) N 2 O emissions from soils under several contrasting bioenergy cropping systems, with specific focus on explaining N 2 O variations by accounting for soil pore characteristics. Intact soil samples were collected after 9 years of implementing five biofuel systems: continuous corn with and without winter cover crop, monoculture switchgrass, poplars, and early–successional vegetation. After incubation, N 2 O emissions were measured and bacterial denitrification was determined based on the site–preference method. Soil pore characteristics were quantified using X–ray computed microtomography. Three bioenergy systems with low plant diversity, that is, corn and switchgrass systems, had low porosities, low organic carbon contents, and large volumes of poorly aerated soil. In these systems, greater volumes of poorly aerated soil were associated with greater bacterial denitrification, which in turn was associated with greater N 2 O emissions ( R 2 = 0.52, p < 0.05). However, the two systems with high plant diversity, that is, poplars and early–successional vegetation, over the 9 years of implementation had developed higher porosities and organic carbon contents. In these systems, volumes of poorly aerated soil were positively associated with N 2 O emissions without a concomitant increase in bacterial denitrification. Our results suggest that changes in soil pore architecture generated by long–term implementation of contrasting bioenergy systems may affect the pathways of N 2 O production, thus, change associations between N 2 O emissions and other soil properties. In conclusion, plant diversity appears as one of the factors determining which microscale soil characteristics will influence the amounts of N 2 O emitted into the atmosphere and, thus, which can be used as effective empirical predictors.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of Data Acquisition Algorithms on X-ray Phase Contrast Imaging Computed Tomography

X-ray phase contrast imaging (XPCI) is a non-destructive evaluation technique that enables high-contrast detection of low-attenuation materials that are largely transparent in traditional radiography. Extending a grating based Talbot-Lau XPCI system to three- dimensional imaging with computed tomography (CT) imposes two motion requirements: the analyzer grating must translate transverse to the optical axis to capture image sets for XPCI reconstruction, and the sample must rotate to capture angular data for CT reconstruction. The acquisition algorithm choice determines the order of movement and positioning of the two stages. The choice of image acquisition algorithm for XPCI CT is instrumental to collecting high fidelity data for reconstruction. We investigate how data acquisition influences XPCI CT by comparing two simple data acquisition algorithms and determine that capturing a full phase-stepping image set for a CT projection before rotating the sample results in higher quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral gratings-based phase-contrast imaging for materials characterization

Spectral X-ray detectors provide a direct observation of the energy spectrum of a transmitted X-ray beam, both for typical and phase-contrast gratings-based systems. The sensitivity of a gratings-based X-ray system to small-angle deflections from a given particle size is dependent on X-ray energy. Therefore, spectral (energy-sensitive) detectors could be sensitive to particle size, even with a broad spectrum from a commercial X-ray generator. Furthermore, these detectors allow direct observation of how the X-ray spectrum is changing as the beam is passing through an object and gratings, and how this affects grating visibilities used to determine the presence of small-angle deflections. This is a particular issue for higher-energy systems where artifacts from beam hardening are common. We present results exploring the particle-size dependent signatures that are available from a spectral gratings-based phase-contrast X-ray imaging system, and the feasibility of observing them with lab-based, broad-spectrum X-ray generators.

Gilbert, Andrew J.↗

Noise in x-ray grating-based phase-contrast imaging

Purpose: Grating-based x-ray phase-contrast imaging is a fast developing new modality not only for medical imaging, but as well for other fields such as material sciences. While these many possible applications arise, the knowledge of the noise behavior is essential. Methods: In this work, the authors used a least squares fitting algorithm to calculate the noise behavior of the three quantities absorption, differential phase, and dark-field image. Further, the calculated error formula of the differential phase image was verified by measurements. Therefore, a Talbot interferometer was setup, using a microfocus x-ray tube as source and a Timepix detector for photon counting. Additionally, simulations regarding this topic were performed. Results: It turned out that the variance of the reconstructed phase is only dependent of the total number of photons used to generate the phase image and the visibility of the experimental setup. These results could be evaluated in measurements as well as in simulations. Furthermore, the correlation between absorption and dark-field image was calculated. Conclusions: These results provide the understanding of the noise characteristics of grating-based phase-contrast imaging and will help to improve image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods

Purpose: Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. Methods: A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and/or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Results: Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of user interaction and resulted in statistically not significantly different segmentation error indices (ANOVA test, significance level of 0.05). Conclusions: All three experts were able to produce liver segmentations with low error rates. User interaction time savings of up to 71% compared to a 2D refinement approach demonstrate the utility and potential of our approach. The system offers a range of different tools to manipulate segmentation results, and some users might benefit from a longer learning phase to develop efficient segmentation refinement strategies. The presented approach represents a generally applicable segmentation approach that can be applied to many medical image segmentation problems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials

Purpose: Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representative of breast tissues. Methods: Elemental compositions of breast tissues including adipose, fibroglandular, and skin were used to determine the refractive index, n= 1 -{delta}+i {beta}. The real part of the refractive index, specifically the refractive index decrement ({delta}), over the energy range of 5-50 keV were determined using XOP software (version 2.3, European Synchrotron Radiation Facility, France). Calcium oxalate and calcium hydroxyapatite were considered to represent the material compositions of microcalcifications in vivo. Nineteen tissue substitutes were considered as possible candidates to represent adipose tissue, fibroglandular tissue and skin, and four phantom materials were considered as possible candidates to represent microcalcifications. For each material, either the molecular formula, if available, or the elemental composition based on weight fraction, was used to determine {delta}. At each x-ray photon energy, the absolute percent difference in {delta} between the breast tissue and the substitute material was determined, from which three candidates were selected. From these candidate tissue substitutes, the material that minimized the absolute percent difference in linear attenuation coefficient {mu}, and hence {beta}, was considered to be best representative of that breast tissue. Results: Over the energy range of 5-50 keV, while the {delta} of CB3 and fibroglandular tissue-equivalent material were within 1% of that of fibroglandular tissue, the {mu} of fibroglandular tissue-equivalent material better approximated the fibroglandular tissue. While the {delta} of BR10 and adipose tissue-equivalent material were within 1% of that of adipose tissue, the tissue-equivalent material better approximated the adipose tissue in terms of {mu}. Polymethyl methacrylate, a commonly used tissue substitute, exhibited {delta} greater than fibroglandular tissue by {approx}12%. The A-150 plastic closely approximated the skin. Several materials exhibited {delta} between that of adipose and fibroglandular tissue. However, there was an energy-dependent mismatch in terms of equivalent fibroglandular weight fraction between {delta} and {mu} for these materials. For microcalcifications, aluminum and calcium carbonate were observed to straddle the {delta} and {mu} of calcium oxalate and calcium hydroxyapatite. Aluminum oxide, commonly used to represent microcalcifications in the American College of Radiology recommended phantoms for accreditation exhibited {delta} greater than calcium hydroxyapatite by {approx}23%. Conclusions: A breast phantom comprising A-150 plastic to represent the skin, commercially available adipose and fibroglandular tissue-equivalent formulations to represent adipose and fibroglandular tissue, respectively, was found to be best suited for x-ray phase-sensitive imaging of the breast. Calcium carbonate or aluminum can be used to represent microcalcifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High spatiotemporal resolution measurement of regional lung air volumes from 2D phase contrast x-ray images

Purpose: Described herein is a new technique for measuring regional lung air volumes from two-dimensional propagation-based phase contrast x-ray (PBI) images at very high spatial and temporal resolution. Phase contrast dramatically increases lung visibility and the outlined volumetric reconstruction technique quantifies dynamic changes in respiratory function. These methods can be used for assessing pulmonary disease and injury and for optimizing mechanical ventilation techniques for preterm infants using animal models. Methods: The volumetric reconstruction combines the algorithms of temporal subtraction and single image phase retrieval (SIPR) to isolate the image of the lungs from the thoracic cage in order to measure regional lung air volumes. The SIPR algorithm was used to recover the change in projected thickness of the lungs on a pixel-by-pixel basis (pixel dimensions {approx}16.2 {mu}m). The technique has been validated using numerical simulation and compared results of measuring regional lung air volumes with and without the use of temporal subtraction for removing the thoracic cage. To test this approach, a series of PBI images of newborn rabbit pups mechanically ventilated at different frequencies was employed. Results: Regional lung air volumes measured from PBI images of newborn rabbit pups showed on average an improvement of at least 20% in 16% of pixels within the lungs in comparison to that measured without the use of temporal subtraction. The majority of pixels that showed an improvement was found to be in regions occupied by bone. Applying the volumetric technique to sequences of PBI images of newborn rabbit pups, it is shown that lung aeration at birth can be highly heterogeneous. Conclusions: This paper presents an image segmentation technique based on temporal subtraction that has successfully been used to isolate the lungs from PBI chest images, allowing the change in lung air volume to be measured over regions as small as the pixel size. Using this technique, it is possible to measure changes in regional lung volume at high spatial and temporal resolution during breathing at much lower x-ray dose than would be required using computed tomography.

60 APPLIED LIFE SCIENCES↗

Feasibility of kilovoltage x-ray energy modulation by gaseous media and its application in contrast-enhanced radiotherapy

Purpose: To present a method to modulate the energy contents of a kilovoltage x-ray beam that makes use of a gas as the modulating medium. The method is capable of producing arbitrary x-ray spectra by varying the pressure of the modulating gas and the peak kilovoltage (kVp) of the x-ray beams whose energy is being modulated.Methods: An aluminum chamber was machined with a 0.5 cm wall thickness, designed to withstand pressures of more than 80 atm. A pressure sensor and electrovalves were used to monitor and regulate the gas pressure. Argon was used as the modulating gas. A CdTe spectrometer was used to measure x-ray spectra for different combinations of kVp and gas pressure, thus obtaining a set of basis x-ray functions. An arbitrary x-ray spectrum can then be formed by the linear combination of such basis functions. In order to show one possible application of the modulation method, a contrast-enhanced radiotherapy prostate treatment was optimized with respect to the x-ray beam energy, without restrictions on the possible shape of the resultant x-ray spectra.Results: The x-ray spectra basis functions obtained display a smooth and gradual variation of their average energy as a function of the gas pressure for a given kVp, sometimes in the order of 1 or 2 keV. This gradual variation would be difficult to obtain with a conventional aluminum or copper filters, as the change in thickness necessary to reproduce the data presented would be in the order of micrometers, making necessary the use of a large number of such filters. Using the modulation method presented here, the authors were able to reconstruct the optimized x-ray spectra from the measured basis functions, for different optimization objectives.Conclusions: A method has been developed that allows for the controlled modulation of the energy contents of kilovoltage x-ray spectra. The method has been shown to be able to reproduce spectra of arbitrary shape, such as those obtained from the optimization of contrast-enhanced radiotherapy. The method may have other applications as well, such as in the precise matching of diagnostic x-ray catalog spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-182: A Feasibility Study Evaluating Automatic Identification of Gross Tumor Volume for Breast Cancer Radiotherapy Using Dynamic Contrast-Enhanced MR Imaging

Purpose: To develop a computerized pharmacokinetic model-free Gross Tumor Volume (GTV) segmentation method based on dynamic contrastenhanced MRI (DCE-MRI) data that can improve physician GTV contouring efficiency. Methods: 12 patients with biopsy-proven early stage breast cancer with post-contrast enhanced DCE-MRI images were analyzed in this study. A fuzzy c-means (FCM) clustering-based method was applied to segment 3D GTV from pre-operative DCE-MRI data. A region of interest (ROI) is selected by a clinician/physicist, and the normalized signal evolution curves were calculated by dividing the signal intensity enhancement value at each voxel by the pre-contrast signal intensity value at the corresponding voxel. Three semi-quantitative metrics were analyzed based on normalized signal evolution curves: initial Area Under signal evolution Curve (iAUC), Immediate Enhancement Ratio (IER), and Variance of Enhancement Slope (VES). The FCM algorithm wass applied to partition ROI voxels into GTV voxels and non-GTV voxels by using three analyzed metrics. The partition map for the smaller cluster is then generated and binarized with an automatically calculated threshold. To reduce spurious structures resulting from background, a labeling operation was performed to keep the largest three-dimensional connected component as the identified target. Basic morphological operations including hole-filling and spur removal were useutilized to improve the target smoothness. Each segmented GTV was compared to that drawn by experienced radiation oncologists. An agreement index was proposed to quantify the overlap between the GTVs identified using two approaches and a thershold value of 0.4 is regarded as acceptable. Results: The GTVs identified by the proposed method were overlapped with the ones drawn by radiation oncologists in all cases, and in 10 out of 12 cases, the agreement indices were above the threshold of 0.4. Conclusion: The proposed automatic segmentation method was shown to be promising and might be used to improve physician contouring efficiency. J Horton receives grant from NIH and Varian Medical Systems; F-F Yin receives grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗