Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Energy and momentum preserving Coulomb collision model for kinetic Monte Carlo simulations of plasma steady states in toroidal fusion devices

A kinetic Monte Carlo model suited for self-consistent transport studies is proposed and tested. The Monte Carlo collision operator is based on a widely used model of Coulomb scattering by a drifting Maxwellian and a new algorithm enforcing the momentum and energy conservation laws. The difference to other approaches consists in a specific procedure of calculating the background Maxwellian parameters, which does not require ensemble averaging and, therefore, allows for the use of single-particle algorithms. This possibility is useful in transport balance (steady state) problems with a phenomenological diffusive ansatz for the turbulent transport, because it allows a direct use of variance reduction methods well suited for single particle algorithms. In addition, a method for the self-consistent calculation of the electric field is discussed. Results of testing of the new collision operator using a set of 1D examples, and preliminary results of 2D modelling in realistic tokamak geometry, are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical Modelling of Glass Fibre Reinforced Laminates Subjected to a Low Velocity Impact

This paper presents a series of numerical predictions of the perforation behaviour of glass fibre laminates subjected to quasi-static and low-velocity impact loading. Both shear and tensile failure criteria were used in the finite element models to simulate the post-failure processes via an automatic element removal procedure. The appropriate material properties, obtained through a series of uniaxial tension and bending tests on the composites, were used in the numerical models. Four, eight and sixteen ply glass fibre laminates panels were perforated at quasi-static rates and under low-velocity impact loading. Reasonably good correlation was obtained between the numerical simulations and the experimental results, both in terms of the failure modes and the load-deflection relationships before and during the penetration phase. The predicted impact energies of the GFRP panels were compared with the experimental data and reasonable agreement was observed.

36 MATERIALS SCIENCE↗

Fractionated stereotactic radiotherapy: A method to evaluate geometric and dosimetric uncertainties using radiochromic films

In the authors' hospital, stereotactic radiotherapy treatments are performed with a Varian Clinac 600C equipped with a BrainLAB m3 micro-multileaf-collimator generally using the dynamic conformal arc technique. Patient immobilization during the treatment is achieved with a fixation mask supplied by BrainLAB, made with two reinforced thermoplastic sheets fitting the patient's head. With this work the authors propose a method to evaluate treatment geometric accuracy and, consequently, to determine the amount of the margin to keep in the CTV-PTV expansion during the treatment planning. The reproducibility of the isocenter position was tested by simulating a complete treatment on the anthropomorphic phantom Alderson Rando, inserting in between two phantom slices a high sensitivity Gafchromic EBT film, properly prepared and calibrated, and repeating several treatment sessions, each time removing the fixing mask and replacing the film inside the phantom. The comparison between the dose distributions measured on films and computed by TPS, after a precise image registration procedure performed by a commercial piece of software (FILMQA, 3cognition LLC (Division of ISP), Wayne, NJ), allowed the authors to measure the repositioning errors, obtaining about 0.5 mm in case of central spherical PTV and about 1.5 mm in case of peripheral irregular PTV. Moreover, an evaluation of the errors in the registration procedure was performed, giving negligible values with respect to the quantities to be measured. The above intrinsic two-dimensional estimate of treatment accuracy has to be increased for the error in the third dimension, but the 2 mm margin the authors generally use for the CTV-PTV expansion seems adequate anyway. Using the same EBT films, a dosimetric verification of the treatment planning system was done. Measured dose values are larger or smaller than the nominal ones depending on geometric irradiation conditions, but, in the authors' experimental conditions, always within 4%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors for converting dose measured in polystyrene phantoms to dose reported in water phantoms for incident proton beams

Purpose: Previous dosimetry protocols allowed calibrations of proton beamline dose monitors to be performed in plastic phantoms. Nevertheless, dose determinations were referenced to absorbed dose-to-muscle or absorbed dose-to-water. The IAEA Code of Practice TRS 398 recommended that dose calibrations be performed with ionization chambers only in water phantoms because plastic-to-water dose conversion factors were not available with sufficient accuracy at the time of its writing. These factors are necessary, however, to evaluate the difference in doses delivered to patients if switching from calibration in plastic to a protocol that only allows calibration in water. Methods: This work measured polystyrene-to-water dose conversion factors for this purpose. Uncertainties in the results due to temperature, geometry, and chamber effects were minimized by using special experimental set-up procedures. The measurements were validated by Monte Carlo simulations. Results: At the peak of non-range-modulated beams, measured polystyrene-to-water factors ranged from 1.015 to 1.024 for beams with ranges from 36 to 315 mm. For beams with the same ranges and medium sized modulations, the factors ranged from 1.005 to 1.019. The measured results were used to generate tables of polystyrene-to-water dose conversion factors. Conclusions: The dose conversion factors can be used at clinical proton facilities to support beamline and patient specific dose per monitor unit calibrations performed in polystyrene phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Connecting CO intensity mapping to molecular gas and star formation in the epoch of galaxy assembly

Intensity mapping, which images a single spectral line from unresolved galaxies across cosmological volumes, is a promising technique for probing the early universe. Here we present predictions for the intensity map and power spectrum of the CO(1–0) line from galaxies at z∼2.4–2.8, based on a parameterized model for the galaxy–halo connection, and demonstrate the extent to which properties of high-redshift galaxies can be directly inferred from such observations. We find that our fiducial prediction should be detectable by a realistic experiment. Motivated by significant modeling uncertainties, we demonstrate the effect on the power spectrum of varying each parameter in our model. Using simulated observations, we infer constraints on our model parameter space with an MCMC procedure, and show corresponding constraints on the L{sub IR}–L{sub CO} relation and the CO luminosity function. These constraints would be complementary to current high-redshift galaxy observations, which can detect the brightest galaxies but not complete samples from the faint end of the luminosity function. By probing these populations in aggregate, CO intensity mapping could be a valuable tool for probing molecular gas and its relation to star formation in high-redshift galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Percutaneous Biopsy and Radiofrequency Ablation of Osteoid Osteoma with Excess Reactive New Bone Formation and Cortical Thickening Using a Battery-Powered Drill for Access: A Technical Note

PurposeTo report our experience with the use of a battery-powered drill in biopsy and radiofrequency ablation of osteoid osteoma with excess reactive new bone formation. The battery-powered drill enables obtaining the sample while drilling.Materials and MethodsDuring the last 18 months, 14 patients suffering from painful osteoid osteoma with excess reactive new bone formation underwent CT-guided biopsy and radiofrequency ablation. In order to assess and sample the nidus of the osteoid osteoma, a battery-powered drill was used. Biopsy was performed in all cases. Then, coaxially, a radiofrequency electrode was inserted and ablation was performed with osteoid osteoma protocol. Procedure time (i.e., drilling including local anesthesia), amount of scans, technical and clinical success, and the results of biopsy are reported.ResultsAccess to the nidus through the excess reactive new bone formation was feasible in all cases. Median procedure time was 50.5 min. Histologic verification of osteoid osteoma was performed in all cases. Radiofrequency electrode was coaxially inserted within the nidus and ablation was successfully performed in all lesions. Median amount CT scans, performed to control correct positioning of the drill and precise electrode placement within the nidus was 11. There were no complications or material failure reported in our study.ConclusionsThe use of battery-powered drill facilitates access to the osteoid osteoma nidus in cases where excess reactive new bone formation is present. Biopsy needle can be used for channel creation during the access offering at the same time the possibility to extract bone samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transition core modeling for extended enrichment, accident tolerant fuel using PARCS/Polaris

Current plans and efforts from reactor operators and vendors to include extended enrichment (EE) and accident-tolerant fuel (ATF) in current reactor fleets motivate the study of these changes in reactor physics analysis. This work uses the US Nuclear Regulatory Commission core simulator PARCS to do the core calculation and SCALE Polaris lattice physics code to generate the required homogenized, few-group constants. The lattice model used is based on the GE-14 10x10 assemblies with UO{sub 2} fuels. Both nominal core and transition core are studied in this work, and both cores use GE-14 10x10 assemblies with UO{sub 2} fuel. The nominal core uses regular UO{sub 2} fuel with a maximum enrichment of 5 wt % and ZIRC-2 cladding. The ATF transition core uses FeCrAl cladding and regular UO{sub 2} fuel, while the EE-ATF transition core uses FeCrAl cladding with UO{sub 2} fuel with 8 max wt % enrichment. The accuracy presented in the colorset models verified the capability of the PARCS/Polaris procedures for the transition core analysis. For the whole core calculation, the ATF and EE-ATF transition core models were made in addition to the nominal core model. The core parameters to study are the core power distribution and power peaking factor, doppler temperature coefficients, and control rod worth at cold zero power and hot full power. Comparing the core parameters of the transition cores with the nominal core in PARCS, the results suggest that there is no unexpected outcome for the implementation of ATF and EE fuels. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gas-kinetic unified algorithm for hypersonic flows covering various flow regimes solving Boltzmann model equation in nonequilibrium effect

Based on the Gas-Kinetic Unified Algorithm (GKUA) directly solving the Boltzmann model equation, the effect of rotational non-equilibrium is investigated recurring to the kinetic Rykov model with relaxation property of rotational degrees of freedom. The spin movement of diatomic molecule is described by moment of inertia, and the conservation of total angle momentum is taken as a new Boltzmann collision invariant. The molecular velocity distribution function is integrated by the weight factor on the internal energy, and the closed system of two kinetic controlling equations is obtained with inelastic and elastic collisions. The optimization selection technique of discrete velocity ordinate points and numerical quadrature rules for macroscopic flow variables with dynamic updating evolvement are developed to simulate hypersonic flows, and the gas-kinetic numerical scheme is constructed to capture the time evolution of the discretized velocity distribution functions. The gas-kinetic boundary conditions in thermodynamic non-equilibrium and numerical procedures are studied and implemented by directly acting on the velocity distribution function, and then the unified algorithm of Boltzmann model equation involving non-equilibrium effect is presented for the whole range of flow regimes. The hypersonic flows involving non-equilibrium effect are numerically simulated including the inner flows of shock wave structures in nitrogen with different Mach numbers of 1.5-Ma-25, the planar ramp flow with the whole range of Knudsen numbers of 0.0009-Kn-10 and the three-dimensional re-entering flows around tine double-cone body.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Infrared behavior and Gribov ambiguity in SU(2) lattice gauge theory

For SU(2) lattice gauge theory, we study numerically the infrared behavior of the Landau-gauge ghost and gluon propagators with a special accent on the Gribov copy dependence. Applying a very efficient gauge-fixing procedure and generating up to 80 gauge copies, we find that the Gribov copy effect for both propagators is essential in the infrared. In particular, our best copy dressing function of the ghost propagator approaches a plateau in the infrared, while for the random first copy it continues to grow. Our best copy zero-momentum gluon propagator shows a tendency to decrease with growing lattice size, which excludes singular solutions. Our results seem compatible with the so-called decoupling solution with a nonsingular gluon propagator. However, we do not yet consider the Gribov copy problem to be resolved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Radiometry for In-Pipe Robotic Inspection of Holdup Deposits in Gaseous Diffusion Piping - 19503

This paper details the first complete, DOE approved, deployed and operational radiometry for robotic nondestructive assay (NDA) of holdup deposits in gaseous diffusion piping. Some features, like peak-finding, Compton correction, detector efficiency, and material properties are characteristic of typical manual methods. Most features are specific to in-pipe robotic deployment. These include in-motion radiometry, self-determined location, geometric modeling of thick deposits, bounding of self-attenuation thickness and auto-checking of replicate measurements. Significant are the means for determining all the properties, equations, and constants for automatically computing and displaying all the quantities, uncertainties and information needed for NDA reporting, analysis, and review. Earlier work by this team demonstrated rudimentary but convincing robotic in-pipe NDA of holdup deposits in pipes. Cold testing with high-enrichment mat sources and hot tests with low U-235 loadings together succeeded to exhibit convincing proof-of-principle. This research-grade radiometry implementation lacked accurate odometry, efficiency calibration, high-fidelity detector modeling, attenuation modeling, forward geometric modeling, auto-segmenting, uncertainty modeling, replicate checking, deconvolution and much more. This work explains the technical basis behind robotic in-pipe NDA. It includes discussion of a new method for modeling of self-attenuation using in-pipe deposit geometry information, detail of the method's total measurement uncertainty, and explanation of calibration methods and results. Beyond development of automation-specific radiometric elements, the paper highlights analyses, testing, and technical bases specific to and supportive of the methodology. Examples include collimation characterization, detector efficiency determination, auto-calibration methodology, and odometric replicate-checking. Results of this methodology are formalized in a DOE EM Technical Basis Document, implemented in software, formally verified in review and acceptance testing and proceduralized as a means for D and D NDA at the Portsmouth enrichment facility. Measurement of U-235 quantity is a well-known cost and schedule driver in D and D of every defunct gaseous diffusion enrichment facility in the world. The radiometry methodologies and results detailed in this paper were the high hurdles. Having established the technical basis for this automated NDA, the opportunity is to apply this to many sizes and robot forms for addressing holdup deposit NDA throughout the D and D community. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Screw Placement and Osteoplasty Under Computed Tomographic-Fluoroscopic Guidance in a Case of Advanced Metastatic Destruction of the Iliosacral Joint

We present a case of combined surgical screw placement and osteoplasty guided by computed tomography-fluoroscopy (CTF) in a 68-year-old man with unilateral osteolytic destruction and a pathological fracture of the iliosacral joint due to a metastasis from renal cell carcinoma. The patient experienced intractable lower back pain that was refractory to analgesia. After transarterial particle and coil embolization of the tumor-feeding vessels in the angiography unit, the procedure was performed under general anesthesia by an interdisciplinary team of interventional radiologists and trauma surgeons. Under intermittent single-shot CTF, two K wires were inserted into the left iliosacral joint from a lateral transiliac approach at the S1 level followed by two self-tapping surgical screws. Continuous CTF was used for monitoring of the subsequent polymethylmethacrylate injection through two vertebroplasty cannulas for further stabilization of the screw threads within the osteolytic sacral ala. Both the screw placement and cement injection were successful, with no complications occurring during or after the procedure. With additional nonsteroidal anti-inflammatory and opioid medication, the patient reported a marked decrease in his lower back pain and was able to move independently again at the 3-month follow-up assessment. In our patient with intolerable back pain due to tumor destruction and consequent pathological fracture of the iliosacral joint, CTF-guided iliosacral screw placement combined with osteoplasty was successful with respect to joint stabilization and a reduction in the need for analgesic therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Foam Sclerotherapy Using Polidocanol (Aethoxysklerol) for Preoperative Portal Vein Embolization in 16 Patients

Purpose: To evaluate the clinical safety and effectiveness of foam sclerotherapy using polidocanol for preoperative portal vein embolization (PVE) before hemihepatectomy of the liver. Materials and Methods: From March 2006 to October 2008, foam sclerotherapy using polidocanol was performed in 16 patients (male-to-female ratio of 12:4, age range 48-75 years [mean 62]) for PVE. Patients were diagnosed with Klatskin tumor (n = 13), gallbladder (GB) cancer (n = 2), or hepatocellular carcinoma (HCC) (n = 1). The foam was composed of a 1:2:1 ratio of 3% polidocanol (Aethoxysklerol; Kreussler Pharma, Wiesbaden, Germany), room air, and contrast media (Xenetix 350; Guerbet, Aulnay-Sous-Bois, France). The total amount of polidocanol used (2 to 8 mL [mean 4.6]) varied according to the volume of the target portal vein. We calculated the volume of future liver remnant (FLR) before and after PVE and evaluated complications associated with the use of polidocanol foam sclerotherapy for PVE. Results: Technical success was achieved in all patients. All patients were comfortable throughout the procedure and did not experience pain during sclerotherapy. No periprocedural morbidity or mortality occurred. Patients underwent a liver dynamic computed tomography (CT) scan 2-4 weeks after PVE. FLR increased significantly after PVE using polidocanol foam from 19.3% (range 16-35%) before PVE to 27.8% (range 23-42%) after PVE (p = 0.001). All patients were operable for hemihepatectomy of the liver and achieved effective resection. Conclusion: Foam sclerotherapy using polidocanol is clinically safe and effective for preoperative PVE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pediatric Percutaneous Osteoid Osteoma Ablation: Cone-Beam CT with Fluoroscopic Overlay Versus Conventional CT Guidance

PurposeTo compare technical success, clinical success, complications, radiation dose, and total room utilization time for osteoid osteoma thermal (radiofrequency or microwave) ablation using cone-beam computed tomography (CBCT) with two-axis fluoroscopic navigational overlay versus conventional computed tomography (CT) guidance.Materials and MethodsA retrospective review was performed to identify all osteoid osteoma ablations performed over a 5.5-year period at a single tertiary care pediatric hospital. Twenty-five ablations (15 radiofrequency and 10 microwave) in 23 patients undergoing fluoroscopic CBCT-guided osteoid osteoma ablation were compared to 35 ablations (35 radiofrequency) in 32 patients undergoing ablation via conventional CT guidance. Dose area product and dose length product were recorded for CBCT and conventional CT, respectively, and converted to effective doses. Technical success, clinical success (cessation of pain and medication use 1 month after ablation), complications, radiation dose, and total room utilization time were compared.ResultsAll procedures were technically successful. Twenty-two of 25 (88.0%) CBCT and 31 of 35 (88.6%) conventional CT-guided ablations achieved immediate clinical success. There were two minor complications in each group and no major complications. Mean effective radiation dose was significantly lower for CBCT compared to CT guidance (0.12 vs. 0.39 mSv, p = 0.02). Mean total room utilization time for CBCT was longer (133.5 vs. 97.5 min, p = 0.0001).ConclusionsFluoroscopic CBCT guidance for percutaneous osteoid osteoma ablation yields similar technical and clinical success, reduced radiation dose, and increased total room utilization time compared to conventional CT guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Serious Neurological Complication Resulting from Inadvertent Intradiscal Injection During Fluoroscopically Guided Interlaminar Epidural Steroid Injection

We describe the case of a 30-year-old patient who was referred for lumbar epidural corticosteroid injection due to right L5 radiculopathy. Two months earlier, MRI demonstrated a right large paracentral L4–L5 disk extrusion causing disabling L5 radiculopathy. The L4–L5 level was selected for interlaminar injection, using fluoroscopic guidance. During injection, the patient developed severe pain in both lower extremities. Thus, the procedure was immediately terminated. Paraplegia occurred within several minutes. Urgent lumbar spine CT and MRI demonstrated contrast material in a massive extruded disk fragment and substantial increase in size of the disk extrusion compared to pre-injection MRI. Emergency surgery was performed for lumbar decompression and discectomy. Although rare, serious neurological complication can result from inadvertent intradiscal injection of contrast material during lumbar epidural injection. This case illustrates the importance of recognizing the possibility of dynamic change in the size of an extruded disk fragment when the MRI precedes injection by a substantial time interval. Level of Evidence: IV, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

REAL-TIME ANALYSIS AND SELECTION BIASES IN THE SUPERNOVA LEGACY SURVEY

The Supernova Legacy Survey (SNLS) has produced a high-quality, homogeneous sample of Type Ia supernovae (SNe Ia) out to redshifts greater than z = 1. In its first four years of full operation (to 2007 June), the SNLS discovered more than 3000 transient candidates, 373 of which have been spectroscopically confirmed as SNe Ia. Use of these SNe Ia in precision cosmology critically depends on an analysis of the observational biases incurred in the SNLS survey due to the incomplete sampling of the underlying SN Ia population. This paper describes our real-time supernova detection and analysis procedures, and uses detailed Monte Carlo simulations to examine the effects of Malmquist bias and spectroscopic sampling. Such sampling effects are found to become apparent at z {approx} 0.6, with a significant shift in the average magnitude of the spectroscopically confirmed SN Ia sample toward brighter values for z {approx}> 0.75. We describe our approach to correct for these selection biases in our three-year SNLS cosmological analysis (SNLS3) and present a breakdown of the systematic uncertainties involved.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo-based simulation of dynamic jaws tomotherapy

Purpose: Original TomoTherapy systems may involve a trade-off between conformity and treatment speed, the user being limited to three slice widths (1.0, 2.5, and 5.0 cm). This could be overcome by allowing the jaws to define arbitrary fields, including very small slice widths (<1 cm), which are challenging for a beam model. The aim of this work was to incorporate the dynamic jaws feature into a Monte Carlo (MC) model called TomoPen, based on the MC code PENELOPE, previously validated for the original TomoTherapy system. Methods: To keep the general structure of TomoPen and its efficiency, the simulation strategy introduces several techniques: (1) weight modifiers to account for any jaw settings using only the 5 cm phase-space file; (2) a simplified MC based model called FastStatic to compute the modifiers faster than pure MC; (3) actual simulation of dynamic jaws. Weight modifiers computed with both FastStatic and pure MC were compared. Dynamic jaws simulations were compared with the convolution/superposition (C/S) of TomoTherapy in the ''cheese'' phantom for a plan with two targets longitudinally separated by a gap of 3 cm. Optimization was performed in two modes: asymmetric jaws-constant couch speed (''running start stop,'' RSS) and symmetric jaws-variable couch speed (''symmetric running start stop,'' SRSS). Measurements with EDR2 films were also performed for RSS for the formal validation of TomoPen with dynamic jaws. Results: Weight modifiers computed with FastStatic were equivalent to pure MC within statistical uncertainties (0.5% for three standard deviations). Excellent agreement was achieved between TomoPen and C/S for both asymmetric jaw opening/constant couch speed and symmetric jaw opening/variable couch speed, with deviations well within 2%/2 mm. For RSS procedure, agreement between C/S and measurements was within 2%/2 mm for 95% of the points and 3%/3 mm for 98% of the points, where dose is greater than 30% of the prescription dose (gamma analysis). Dose profiles acquired in transverse and longitudinal directions through the center of the phantom were also compared with excellent agreement (2%/2 mm) between all modalities. Conclusions: The combination of weights modifiers and interpolation allowed implementing efficiently dynamic jaws and dynamic couch features into TomoPen at a minimal cost in terms of efficiency (simulation around 8 h on a single CPU).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New measurement of the {sup 68}Zn(4{sub 1}{sup +}) g factor combined with a reanalysis of previous data

We have remeasured and have redetermined the g factor for the 4{sub 1}{sup +} state in {sup 68}Zn following inconsistencies between earlier measurements and a recent result. We have reanalyzed several former measurements by applying an alternative analysis procedure, which allows for determining the precession effect separately for each gamma detector implying less uncertainties in the background subtraction for the relevant spectra. In addition, all measured g-factor and B(E2) data for the first 2{sup +} and 4{sup +} states in all stable even-A Zn isotopes and the radioactive {sup 62}Zn, are compared with new large-scale shell model calculations based on the most advanced effective interaction in the fpg-shell model space.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Measurement of Scatter to Primary Ratio by Localized Primary Modulation in Industrial Computed Radiography

The scatter-to-primary ratio (SPR), can serve as an important parameter for performing the scatter correction procedures or build up factor determination in radiography projections. In this work an experimental technique is presented based on localized primary modulation for direct SPR measurement. As illustrative examples, the SPR is measured for steel and aluminum step wedges to demonstrate the applicability of the presented technique in computed radiography. As a required parameter, the effective transmission factor of the modulator is measured using primary beam stopping concept over a calibration block. This technique has significant advantages such as a straight forward theory, simplified applicability in industrial site conditions, beam hardening consideration as well as automation possibility. The technique works by a single image acquisition, without image data loss in the interested area.

42 ENGINEERING↗