Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coil design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Precise Fabrication of Electromagnetic-Levitation Coils

Winding copper tubing on jig ensures reproducible performance. Sequence of steps insures consistent fabrication of levitation-and-melting coils. New method enables technician to produce eight coils per day, 95 percent of them acceptable. Method employs precise step-by-step procedure on specially designed wrapping and winding jig.

Ethridge, E.↗

The IRAC Shutter Mechanism: Residual Magnetism and the Rotary Solenoid

The Infrared Array Camera (IRAC) Shutter mechanism was originally presented in the paper, 'A Low Power Cryogenic Shutter Mechanism for Use on Infrared Imagers' at the 34th Aerospace Mechanisms Symposium, May 2000. At that time, the shutter was believed to be performing flawlessly and there was every indication it would continue to do so. In early spring of 2001, the calibration shutter, a rotary solenoid designed to be fail-safe open, remained in a closed state with no power to the electromagnetic coils. The ensuing investigation, subsequent testing, proposed remedy, and lessons learned are the focus of this paper.

Schwinger, Scott↗

The Plasmoid Thruster Experiment (PTX)

A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic fields. If B(sup p)/B(sub t) is much greater than 1, it is an FRC; if B(sub p) approximately equals B(sub t), it is a Spheromak. A plasmoid thruster would operate by repetitively producing plasmoids that are accelerated to high velocity. The process is inductive, and the magnetic structure of the plasmoid suppresses thermal and mass losses, and improves detachment of the exhaust. This concept should be capable of producing an Isp in the range of 5,000 - 10,OOO seconds, with high thrust density. PTX is a device designed to study this concept. The plasmoid is formed inside of a single turn conical theta-pinch coil, driven by a 560 nF, 35 kV capacitor bank. Experiments conducted with a static-fill of propellant gas (6% H2 in He) demonstrated reliable ionization over a pressure range of 40 - 200 mTorr. A fast gas-puff valve to inject propellant has since been added, and a ringing pre-ionization circuit to independently control ionization has been tested. Hydrogen, deuterium, argon, and an N2/H2 mixture have been tried as propellants. Measurements of the plasmoid shape, mass, and velocity, using a variety of diagnostics will be presented,

Martin, Adam↗

The Plasmoid Thruster Experiment (PTX)

A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic fields. If B(sub p/B(sub t) much greater than 1 it is an FRC; if B(sub p) approximately equal to B(sub t), it is a Spheromak. A plasmoid thruster would operate by repetitively producing plasmoids that are accelerated to high velocity. The process is inductive, and the magnetic structure of the plasmoid suppresses thermal and mass losses, and improves detachment of the exhaust, This concept should be capable of producing an Isp in the range of 5,000 - l0,000 seconds, with high thrust density. PTX is a device designed to study this concept. The plasmoid is formed inside of a single turn conical theta-pinch coil, driven by a 560 nF, 35 kV capacitor bank. Experiments conducted with a static-fill of propellant gas (6% H2 in He) demonstrated liable ionization over a pressure range of 40 - 200 mTorr. A fast gas-puff valve to inject propellant has since been added, and a ringing preionization circuit to independently control ionization has been tested, hydrogen, deuterium, argon, and an N2 / H2 mixture have been tried as propellants. Measurements of the plasmoid shape, mass, and velocity, using a variety of diagnostics will be presented.

Martin, Adam↗

Electromagnetic Redesign of NASA’s High Efficiency Megawatt Motor

NASA’s High Efficiency Megawatt Motor (HEMM) is being developed to achieve the performance needed by single aisle class electrified aircraft. It is a 1.4 MW electric machine designed as a generator for NASA’s STARC-ABL concept vehicle. It has performance objectives of greater than 16 kW/kg electromagnetic specific power and efficiency of greater than 98%. A significant flaw in the preliminary electromagnetic design of HEMM was recently discovered. The stator teeth in the preliminary design cause the magnetic flux in the rotating components of HEMM to oscillate at a very high frequency (12,240 Hz). Two independent energy loss analyses are presented to show that the frequency is high enough to cause eddy current losses that significantly exceed the rotor’s loss limit (50 W), despite the very small magnitude of this flux oscillation (<0.01 T). To eliminate these rotor losses, while continuing to meet the target performance, it was determined that the stator teeth needed to be removed and the electromagnetic geometry of the motor needed to be revised. The revised, slotless HEMM motor design is summarized. Sensitivity of the new design to key unknown variables such as the temperature of and number of turns in the superconducting rotor coils and the stator winding’s average temperature.

Thomas T Tallerico↗

Design of a Microwave Assisted Discharge Inductive Plasma Accelerator

The design and construction of a thruster that employs electrodeless plasma preionization and pulsed inductive acceleration is described. Preionization is achieved through an electron cyclotron resonance discharge that produces a weakly-ionized plasma at the face of a conical theta pinch-shaped inductive coil. The presence of the preionized plasma allows for current sheet formation at lower discharge voltages than those employed in other pulsed inductive accelerators that do not employ preionization. The location of the electron cyclotron resonance discharge is controlled through the design of the applied magnetic field in the thruster. Finite element analysis shows that there is an arrangement of permanent magnets that yields a small volume of resonant magnetic field at the coil face. Preionization in the resonant zone leads to current sheet formation at the coil face, which minimizes the initial inductance of the pulse circuit and maximizes the potential electrical efficiency of the accelerator. A magnet assembly was constructed around an inductive coil to provide structural support to the selected arrangement of neodymium magnets. Measured values of the resulting magnetic field compare favorably with the finite element model.

Hallock, Ashley K.↗

Rotating-Coil Measurement System for Small-Bore-Diameter Magnet Characterization

Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.

42 ENGINEERING↗

Beam builder for space fabrication

Construction of a beam builder for producing triangular truss aluminum beams for use on large space structures is described. The machine will fabricate 0.04 cm thick 2024-T3 aluminum alloy into beams weighing 1.265 kg-m with side braces spot-welded to end caps to fabricate a triangular truss configuration up to 305 m long. The design characteristics, the electrical subsystems, the power requirements of the spot welding equipment, and the computer system for coordinating the motion of the Yoder rolling mills for forming caps from aluminum coils are described. Spot welding was compared with ultrasonic welding, stapling, wire stitching, riveting, grommets, stamp-lok, and pierce and fold joining methods with respect to ease of operation, safety, practicality, and ease of energy consumption. The beam builder will be evaluated to identify design requirements which can be utilized for the space flight version of its concept.

Ehl, J. H.↗

The PIT MkV pulsed inductive thruster

The pulsed inductive thruster (PIT) is an electrodeless, magnetic rocket engine that can operate with any gaseous propellant. A puff of gas injected against the face of a flat (spiral) coil is ionized and ejected by the magnetic field of a fast-rising current pulse from a capacitor bank discharge. Single shot operation on an impulse balance has provided efficiency and I(sub sp) data that characterize operation at any power level (pulse rate). The 1-m diameter MkV thruster concept offers low estimated engine mass at low powers, together with power capability up to more than 1 MW for the 1-m diameter design. A 20 kW design estimate indicates specific mass comparable to Ion Engine specific mass for 10,000 hour operation, while a 100,000 hour design would have a specific mass 1/3 that of the Ion Engine. Performance data are reported for ammonia and hydrazine. With ammonia, at 32 KV coil voltage, efficiency is a little more than 50 percent from 4000 to more than 8000 seconds I(sub sp). Comparison with data at 24 and 28 kV indicates that a wider I(sub sp) range could be achieved at higher coil voltages, if required for deep space missions.

Dailey, C. Lee↗

Printed Circuit Board Based Rotating Coils for Measuring Sextupole Magnets

Here, the use of Printed Circuit Boards (PCBs) for the inductive pick-up windings of rotating coil probes has made the construction of these precision magnetic measurement devices much more accessible. This paper discusses the design details for PCBs which on each layer of the board provide for simultaneous analog bucking (suppression) of dipole, quadrupole, and sextupole field components so as to more accurately measure the higher order harmonic fields in sextupole magnets. Techniques to generate designs are discussed, as well as trade-offs to optimize sensitivity. Examples of recent sextupole PCBs and their performance are given.

43 PARTICLE ACCELERATORS↗

Design Considerations for the Implementation of a High-Field-Side Transient CHI System on QUEST

Transient coaxial helicity injection (T-CHI), a method first developed on the small helicity injected torus (HIT-II) experiment and then validated on the much larger National Spherical Torus Experiment (NSTX) device, is a method to initiate an inductive-like tokamak plasma discharge without reliance on the central solenoid. A CHI discharge is initiated by driving current along magnetic flux that connects the inner and outer divertor plates on one end of the tokamak. To permit this, on both HIT-II and NSTX, toroidal ceramic insulators were used to electrically separate the inner and outer vessel components. The use of such large toroidal vacuum insulators may not be easy to implement in reactors. To address this issue, the Q-shu University experiments with steady-state spherical tokamak (ST) (QUEST) is developing a reactor-relevant CHI configuration in which one of the divertor plates is electrically insulated from the rest of the vessel. The first application of T-CHI on QUEST biased the CHI electrode to the outer vessel. While the CHI discharges could be easily generated, it was found that as the discharge filled the vessel, the separation distance between the injector magnetic flux footprints widened, a condition that is not favorable for the generation of closed flux surfaces. Biasing the electrode to the inner wall is a configuration similar to that used on NSTX and HIT-II, but initial testing in this configuration has proved to be challenging. The design described here overcomes the present limitation by locating the CHI electrode much closer to the CHI injector flux coil and using an NSTX-like gas injection manifold to enable high-field-side T-CHI startup on QUEST. Finally, the concepts described in this article should also benefit the future implementation of T-CHI systems in other tokamaks and spherical tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simplified cut-core inductor

Technical memorandum describes design of linear reactor fabricated from grain-oriented steel. It includes design charts and nomographs and illustrates design of grain-oriented inductor via seven-step example. Typical values of core inductance, operating frequency, and coil current (dc and ac) are given.

Mclyman, W. T.↗

Improved Coil for Hydrogen Dissociators

Flat coil has rigid printed circuit substrate. New coil structure minimizes RF electric field near glass walls of plasma vessel; therefore reduces direct electron bombardment of glass. Design lends itself well to high production and standardized dimensions.

Vessot, R.↗

Design of a prototype secondary mirror assembly for the Space Infrared Telescope Facility

The design of a liquid helium temperature prototype secondary mirror assembly (PSMA) under development for the NASA Space Infrared Telescope Facility (SIRTF) program is described. The SIRTF assembly must operate below 4 K and provide the functions of highly precise two-axis periodic tilting ('chopping') in addition to the conventional functions of focus and collimation adjustment. The PSMA design employs a fused quartz mirror kinematically attached at its center to an aluminum cruciform. The mirror/cruciform assembly is driven in tilt about its combined center of mass using an aluminum flexure pivot of unique design and a four-actuator control system with feedback provided by pairs of differential position sensors. The voice coil actuators are mounted on a second flexure-pivoted mass to enhance servosystem stability and isolate the telescope from vibration-induced disturbances. The mirror/cruciform and reaction mass are attached to opposite sides of an aluminum mounting plate whose position relative to the outer housing is controlled by a six-degree-of-freedom focus and centering mechanism using pivoted actuation levers driven by lead screw/harmonic drive/stepper motor assemblies.

Stier, Mark T.↗

High-Purity Aluminum Magnet Technology for Advanced Space Transportation Systems

Basic research on advanced plasma-based propulsion systems is routinely focused on plasmadynamics, performance, and efficiency aspects while relegating the development of critical enabling technologies, such as flight-weight magnets, to follow-on development work. Unfortunately, the low technology readiness levels (TRLs) associated with critical enabling technologies tend to be perceived as an indicator of high technical risk, and this, in turn, hampers the acceptance of advanced system architectures for flight development. Consequently, there is growing recognition that applied research on the critical enabling technologies needs to be conducted hand in hand with basic research activities. The development of flight-weight magnet technology, for example, is one area of applied research having broad crosscutting applications to a number of advanced propulsion system architectures. Therefore, NASA Marshall Space Flight Center, Louisiana State University (LSU), and the National High Magnetic Field Laboratory (NHMFL) have initiated an applied research project aimed at advancing the TRL of flight-weight magnets. This Technical Publication reports on the group's initial effort to demonstrate the feasibility of cryogenic high-purity aluminum magnet technology and describes the design, construction, and testing of a 6-in-diameter by 12-in-long aluminum solenoid magnet. The coil was constructed in the machine shop of the Department of Physics and Astronomy at LSU and testing was conducted in NHMFL facilities at Florida State University and at Los Alamos National Laboratory. The solenoid magnet was first wound, reinforced, potted in high thermal conductivity epoxy, and bench tested in the LSU laboratories. A cryogenic container for operation at 77 K was also constructed and mated to the solenoid. The coil was then taken to NHMFL facilities in Tallahassee, FL. where its magnetoresistance was measured in a 77 K environment under steady magnetic fields as high as 10 T. In addition, the temperature dependence of the coil's resistance was measured from 77 to 300 K. Following this series of tests, the coil was transported to NHMFL facilities in Los Alamos, NM, and pulsed to 2 T using an existing capacitor bank pulse generator. The coil was completely successful in producing the desired field without damage to the windings.

Goodrich, R. G.↗

US HL-LHC Accelerator Upgrade Project (MQXFA Final Design Report)

The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.

43 PARTICLE ACCELERATORS↗

Design and Construction of a Prototype B1pF Large Aperture Rutherford Cable Superconducting Magnet for the EIC Interaction Region

Brookhaven National Laboratory (BNL) was chosen to host the international Electron-Ion Collider (EIC), which will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV. The Interaction Region (IR) requires several large aperture, relatively high field superconducting dipole and quadrupole magnets, some of which are very closely spaced. B1pF is a large aperture (300 mm coil ID), medium field (4.2 T), 3 meter long superconducting dipole magnet. Its size is larger than the largest superconducting magnet in the RHIC accelerator (180 mm DX dipole, 4.2 T, 3.7 m long). As such, B1pF was chosen as the representative magnet to be prototyped to demonstrate the technological choice, design and construction details. Here, this paper describes the analyses and considerations which informed both the magnet and magnet tooling designs. This paper will summarize the construction results so far, in particular the plan for novel coil winding tooling and the test coil winding & curing program that was carried out prior to coil and magnet construction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure-based group A streptococcal vaccine design: Helical wheel homology predicts antibody cross-reactivity among streptococcal M protein–derived peptides

Group A streptococcus (Strep A) surface M protein, an α-helical coiled-coil dimer, is a vaccine target and a major determinant of streptococcal virulence. The sequence-variable N-terminal region of the M protein defines the M type and also contains epitopes that promote opsonophagocytic killing of streptococci. Recent reports have reported considerable cross-reactivity among different M types, suggesting the prospect of identifying cross-protective epitopes that would constitute a broadly protective multivalent vaccine against Strep A isolates. In this work, we have used a combination of immunological assays, structural biology, and cheminformatics to construct a recombinant M protein–based vaccine that included six Strep A M peptides that were predicted to elicit antisera that would cross-react with an additional 15 nonvaccine M types of Strep A. Rabbit antisera against this recombinant vaccine cross-reacted with 10 of the 15 nonvaccine M peptides. Two of the five nonvaccine M peptides that did not cross-react shared high sequence identity (≥50%) with the vaccine peptides, implying that high sequence identity alone was insufficient for cross-reactivity among the M peptides. Additional structural analyses revealed that the sequence identity at corresponding polar helical-wheel heptad sites between vaccine and nonvaccine peptides accurately distinguishes cross-reactive from non–cross-reactive peptides. On the basis of these observations, we developed a scoring algorithm based on the sequence identity at polar heptad sites. When applied to all epidemiologically important M types, this algorithm should enable the selection of a minimal number of M peptide–based vaccine candidates that elicit broadly protective immunity against Strep A.

60 APPLIED LIFE SCIENCES↗