Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “carbon dioxide concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Methods for separating components

Method for concentrating components through a distillation column are disclosed. A process stream is provided containing hydrocarbons, carbon dioxide, and water. The process stream is passed into the distillation column at a bottom portion of the distillation column. The process stream is fractionally distilled in the distillation column, forming an overhead vapor stream, a middle fluid stream, and a bottoms liquid stream. The middle fluid stream is removed from a middle location of the distillation column. The bottoms liquid stream is removed from the distillation column. The overhead vapor stream is removed from the distillation column. The middle fluid stream consists of a first portion of the carbon dioxide and a first portion of the hydrocarbons. The bottoms liquid stream consists of a second portion of the hydrocarbons as a first phase and substantially all the water as a second phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of atmospheric oxygen on leaf structure and starch deposition in Arabidopsis thaliana

Plant culture in oxygen concentrations below ambient is known to stimulate vegetative growth, but apart from reports on increased leaf number and weight, little is known about development at subambient oxygen concentrations. Arabidopsis thaliana (L.) Heynh. (cv. Columbia) plants were grown full term in pre-mixed atmospheres with oxygen partial pressures of 2.5, 5.1, 10.1, 16.2, and 21.3 kPa O2, 0.035 kPa CO2 and the balance nitrogen under continuous light. Fully expanded leaves were harvested and processed for light and transmission electron microscopy or for starch quantification. Growth in subambient oxygen concentrations caused changes in leaf anatomy (increased thickness, stomatal density and starch content) that have also been described for plants grown under carbon dioxide enrichment. However, at the lowest oxygen treatment (2.5 kPa), developmental changes occurred that could not be explained by changes in carbon budget caused by suppressed photorespiration, resulting in very thick leaves and a dwarf morphology. This study establishes the leaf parameters that change during growth under low O2, and identifies the lower concentration at which O2 limitation on transport and biosynthetic pathways detrimentally affects leaf development. Grant numbers: NAG5-3756, NAG2-1020, NAG2-1375.

Non-NASA Center↗

Progress on High-Energy 2-micron Solid State Laser for NASA Space-Based Wind and Carbon Dioxide Measurements

Sustained research efforts at NASA Langley Research Center during last fifteen years have resulted in significant advancement of a 2-micron diode-pumped, solid-state laser transmitter for wind and carbon dioxide measurements from ground, air and space-borne platforms. Solid-state 2-micron laser is a key subsystem for a coherent Doppler lidar that measures the horizontal and vertical wind velocities with high precision and resolution. The same laser, after a few modifications, can also be used in a Differential Absorption Lidar system for measuring atmospheric CO2 concentration profiles. Researchers at NASA Langley Research Center have developed a compact, flight capable, high energy, injection seeded, 2-micron laser transmitter for ground and airborne wind and carbon dioxide measurements. It is capable of producing 250 mJ at 10 Hz by an oscillator and one amplifier. This compact laser transmitter was integrated into a mobile trailer based coherent Doppler wind and CO2 DIAL system and was deployed during field measurement campaigns. This paper will give an overview of 2-micron solid-state laser technology development and discuss results from recent ground-based field measurements.

Singh, Upendra N.↗

Advances in High Energy Solid-State 2-micron Laser Transmitter Development for Ground and Airborne Wind and CO2 Measurements

Sustained research efforts at NASA Langley Research Center (LaRC) during last fifteen years have resulted in a significant advancement in 2-micron diode-pumped, solid-state laser transmitter for wind and carbon dioxide measurement from ground, air and space-borne platform. Solid-state 2-micron laser is a key subsystem for a coherent Doppler lidar that measures the horizontal and vertical wind velocities with high precision and resolution. The same laser, after a few modifications, can also be used in a Differential Absorption Lidar (DIAL) system for measuring atmospheric CO2 concentration profiles. Researchers at NASA Langley Research Center have developed a compact, flight capable, high energy, injection seeded, 2-micron laser transmitter for ground and airborne wind and carbon dioxide measurements. It is capable of producing 250 mJ at 10 Hz by an oscillator and one amplifier. This compact laser transmitter was integrated into a mobile trailer based coherent Doppler wind and CO2 DIAL system and was deployed during field measurement campaigns. This paper will give an overview of 2-micron solid-state laser technology development and discuss results from recent ground-based field measurements.

Singh, Upendra N.↗

Enhanced Carbon Dioxide Uptake in Drilled Hollow Core Fibers for Raman Spectroscopy

Fiber-based Raman spectroscopy enhances the Raman signal by maximizing the overlap of the optical field and the gas species. However, filling the hollow-core fiber (HCF) with gas requires time that is dependent on the fiber core diameter, fiber length, and pressure of the gas. At ambient pressure, the fiber gas uptake is driven by diffusion into the fiber ends, severely limiting the response time of the system. By laser drilling access holes to the core along the length of the fiber, the uptake time of the gas is reduced, improving the system response time. In this work, we study the carbon dioxide (CO 2 ) sensor dynamics based on Raman signal intensity generated in HCFs. The signal intensity versus gas concentration is characterized by controlling the CO 2 concentration in the surrounding environment of the fiber. Next, we characterize the gas uptake time in HCFs as a function of fiber length. Finally, we optimize the access hole configuration along the fiber, demonstrating reduced sensor uptake time by a factor of three.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Downstream Separation of Formic Acid with Anion-Exchange Resin from Electrocatalytic Carbon Dioxide (CO 2 ) Conversion: Adsorption, Kinetics, and Equilibrium Modeling

The electrocatalytic carbon dioxide reduction reaction (CO 2 RR) that produces liquid formic acid (FA) is one potential route to minimize the CO 2 concentration in the atmosphere by utilizing CO 2 as a feedstock. However, one of the main disadvantages of this route is the high energy demand required for purification through conventional distillation. This method of purification has been shown to result in a large carbon footprint in life-cycle analysis (LCA). Therefore, finding an alternative purification technique that can integrate with an electrochemical CO 2 RR process with the potential to lower the carbon footprint would be of great interest. Under the experimental conditions of the CO 2 RR, FA remains in its basic form as the formate anion in the catholyte. Anion exchange resins with their basic properties can separate the formate anion from the catholyte mixture as an alternative to energy intensive distillation. In this work, three anion exchange resins with increasing basicity order: Amberlite IRA-96 < Amberlite IRA-910 < Ambersep 900 are tested to separate FA in the presence of aqueous solution of potassium bicarbonate catholyte with varying levels of resin and FA. Kinetics and equilibrium studies data for the FA adsorption are interpreted using several kinetics and isotherm models. The kinetics data fit well with a pseudo-first-order model at high initial FA concentrations and a pseudo-second-order model at low initial FA concentrations. The experimental data can be best explained with the Freundlich isotherm model. The fitted results show that strongly basic Ambersep 900 is more effective at separating FA, with a maximum adsorption capacity of 336.7 mg/g compared to Amberlite IRA-96 (275.2 mg/g) and Amberlite IRA-910 (209.2 mg/g) in neutral water. However, weakly basic Amberlite IRA-96 (110.8 mg/g) can separate FA more efficiently from potassium bicarbonate catholyte than Amberlite IRA-910 (99.9 mg/g) and Ambersep 900 (40.0 mg/g). As a result, competitive adsorption occurs in the presence of potassium bicarbonate catholyte, but the formic acid adsorption capacity is still sufficient for adequate separation.

20 FOSSIL-FUELED POWER PLANTS↗

Reaching 1.5 and 2.0 °C global surface temperature targets using stratospheric aerosol geoengineering

A new set of stratospheric aerosol geoengineering (SAG) model experiments has been performed with Community Earth System Model version 2 (CESM2) with the Whole Atmosphere Community Climate Model (WACCM6) that are based on the Coupled Model Intercomparison Project phase 6 (CMIP6) overshoot scenario (SSP5-34-OS) as a baseline scenario to limit global warming to 1.5 or 2.0 °C above 1850–1900 conditions. The overshoot scenario allows us to applying a peak-shaving scenario that reduces the needed duration and amount of SAG application compared to a high forcing scenario. In addition, a feedback algorithm identifies the needed amount of sulfur dioxide injections in the stratosphere at four pre-defined latitudes, 30 °N, 15 °N, 15 °S, and 30 °S, to reach three surface temperature targets: global mean temperature, and interhemispheric and pole-to-Equator temperature gradients. These targets further help to reduce side effects, including overcooling in the tropics, warming of high latitudes, and large shifts in precipitation patterns. These experiments are therefore relevant for investigating the impacts on society and ecosystems. Comparisons to SAG simulations based on a high emission pathway baseline scenario (SSP5-85) are also performed to investigate the dependency of impacts using different injection amounts to offset surface warming by SAG. We find that changes from present-day conditions around 2020 in some variables depend strongly on the defined temperature target (1.5 °C vs. 2.0 °C). These include surface air temperature and related impacts, the Atlantic Meridional Overturning Circulation, which impacts ocean net primary productivity, and changes in ice sheet surface mass balance, which impacts sea level rise. Others, including global precipitation changes and the recovery of the Antarctic ozone hole, depend strongly on the amount of SAG application. Furthermore, land net primary productivity as well as ocean acidification depend mostly on the global atmospheric CO 2 concentration and therefore the baseline scenario. Multi-model comparisons of experiments that include strong mitigation and carbon dioxide removal with some SAG application are proposed to assess the robustness of impacts on societies and ecosystems.

42 ENGINEERING↗

Performance Analyses of Supercritical Carbon Dioxide-Based Parabolic Trough Collectors with Double-Glazed Receivers

Supercritical carbon dioxide is becoming a hot research topic as a potential heat transfer fluid in parabolic trough concentrators since it enables operating the solar system at high temperatures for a higher quality of energy. However, the corresponding inflated thermal losses necessitate alternative receiver designs. This work examines four double-glazed receivers, with each annular space being evacuated or non-evacuated, in terms of the absorber tube's diameter (53-80 mm) and the diameter ratios of the two glass shells (1.2-2.0). An analytical model is developed and validated for this purpose, and the four designs are further examined using ground-level solar and meteorological measurements. The results demonstrate higher performance in the case of fully evacuating the receiver and using the smallest possible diameters of the three concentric cylinders, where the energy and exergy efficiencies reach 65.3 and 40.3%, respectively. Yet, evacuating only the inner annular space is sufficient to achieve virtually the same performance level. This energy efficiency decreases to 62% in case of increasing the tube diameter to 80 mm. As the operating temperature increases from 423 to 850 K, the specific thermal losses increase by 3.98-4.34 folds, depending on the receiver design. Double glazing the receivers is favorable only at high operating temperatures of sCO2, where the reduction in thermal losses overcomes the drop in optical efficiency. For an inlet sCO2 temperature of 850 K, thermal losses are reduced by 33.64 and 53.92%, compared to evacuated and non-evacuated single-glazed receivers, respectively. Throughout the year, the fully evacuated and fully non-evacuated double-glazed receivers have energy efficiencies of 54.96 and 52.39%, exergy efficiencies of 33.64 and 32.06%, and thermal losses of 348.8 and 402.5 W/m, respectively.

analytical model↗

Convective Heat Transfer Potential of Particles/Airflow Through Single Cell Thick Additively Manufactured Octet-Shaped Lattice Frame Material

Abstract Particle-to-Supercritical Carbon Dioxide (sCO2) heat exchangers are one of the most critical components of the next-generation Concentrating Solar Power (CSP) plants. There have been several efforts to enhance the overall heat exchanger performance which essentially comprises of thermal resistances offered by sCO2 channel, wall (separating sCO2 with particles) thickness, particle-wall contact resistance and particle-side effective heat transfer coefficient. This study is focused towards reducing the particle side thermal resistance by incorporating single unit cell thick reticulated Octet lattice frame structures on the falling particle side to enhance the effective thermal conductivity of the particle channel and to enhance convective heat transfer between the falling particles and the solid phase of the falling particle channel (endwalls and fibers). Steady-state experiments were conducted to measure the effective thermal conductivity of lattice frame material for two cases: a) when void space was occupied by air, b) when void space was occupied with particles. Further, convective heat transfer experiments have been conducted with both air (steady-state) and particles (quasi steady-state) as “working fluid” for panels sandwiching the Octet array. Three different lattice porosities ranging from 0.75 to 0.9 have been tested for a wide range of air flow rates and a fixed particle flow rate (highest potential).

Aider, Youssef↗

Laser absorption spectrometer - Remote measurement of tropospheric ozone

The laser absorption spectrometer (LAS) is an airborne instrument able to perform remote measurement of trace atmospheric gases. The instrument uses a pair of carbon dioxide laser-heterodyne receiver systems that are directed downward from an airplane and determines gas concentration by the differential absorption method. Configured to measure tropospheric ozone, the LAS has been used in conjunction with another instrumented aircraft to test the accuracy of this method of measurement. A complete description of the instrument is presented, and the results of extensive flight testing are summarized.

Shumate, M. S.↗

Testing an Algae-Based Air-Regeneration System

The potential of an air-regeneration system based on the growth of unicellular algae on the surface of porous ceramic tubes was evaluated. The system is fairly robust with respect to environmental conditions and is capable of maintaining algal cultures for up to 365 days. Under standard conditions (50-66 micro mol/sq mm s (PPF), 450 micro mol mol of CO2), mature tubes can remove CO2 at a rate of up to 90 micro mol/sq m min. Under these conditions, approximately 200 square meters of area would be required for each member of the crew. However, the rate of uptake increases with both photon flux and CO2 concentration in accordance with Michaelis-Menton dynamics. An extrapolation to conditions of saturating light and carbon dioxide indicates that the area required can be reduced by a factor of at least 2.5.

Nienow, James↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

Maintaining Adequate Carbon Dioxide Washout for an Advanced Extravehicular Mobility Unit

Over the past several years, NASA has realized tremendous progress in technology development that is aimed at the production of an Advanced Extravehicular Mobility Unit (AEMU). Of the many functions provided by the spacesuit and portable life support subsystem within the AEMU, delivering breathing gas to the astronaut along with removing the carbon dioxide (CO2) remains one of the most important environmental functions that the AEMU can control. Carbon dioxide washout is the capability of the ventilation flow in the spacesuit helmet to provide low concentrations of CO2 to the crew member to meet breathing requirements. CO2 washout performance is a critical parameter needed to ensure proper and sufficient designs in a spacesuit and in vehicle applications such as sleep stations and hygiene compartments. Human testing to fully evaluate and validate CO2 washout performance is necessary but also expensive due to the levied safety requirements. Moreover, correlation of math models becomes challenging because of human variability and movement. To supplement human CO2 washout testing, a breathing capability will be integrated into a suited manikin test apparatus to provide a safe, lower cost, stable, easily modeled alternative to human testing. Additionally, this configuration provides NASA Johnson Space Center (JSC) the capability to evaluate CO2 washout under off-nominal conditions that would otherwise be unsafe for human testing or difficult due to fatigue of a test subject. Testing has been under way in-house at JSC and analysis has been initiated to evaluate whether the technology provides sufficient performance in ensuring that the CO2 is removed sufficiently and the ventilation flow is adequate for maintaining CO2 washout in the AEMU spacesuit helmet of the crew member during an extravehicular activity. This paper will review recent CO2 washout testing and analysis activities, testing planned in-house with a spacesuit simulator, and the associated analytical work along with insights from the medical aspect on the testing.

Chullen, Cinda↗

Effects of Acute Exposures to Carbon Dioxide Upon Cognitive Functions

Large quantities of carbon dioxide (CO2) originate from human metabolism and typically, within spacecraft, remain about 10-fold higher in concentration than at the earth's surface. There have been recurring complaints by crew members of episodes of "mental viscosity" adversely affecting their performance, and there is evidence from the International Space Station (ISS) that associates CO2 levels with reports of headaches by crewmembers. Additionally, there is concern that CO2 may contribute to vision impairment and intracranial pressure that has been observed in some crewmembers. Consequently, flight rules have been employed to control the level of CO2 below 4 mm Hg, which is well below the existing Spacecraft Maximum Allowable Concentration (SMAC) of 10 mm Hg for 24-hour exposures, and 5.3 mm Hg for exposures of 7 to 180 days. However, the flight rule imposed limit, which places additional demands upon resources and current technology, still exceeds the lower bound of the threshold range for reportable headaches (2 - 5 mm Hg). Headaches, while sometime debilitating themselves, are also symptoms that can provide evidence that physiological defense mechanisms have been breached. The causes of the headaches may elicit other subtle adverse effects that occur at CO2 levels well below that for headaches. The concern that CO2 may have effects at levels below the threshold for headaches appears to be substantiated in unexpected findings that CO2 at concentrations below 2 mm Hg substantially reduced some cognitive functions that are associated with the ability to make complex decisions in conditions that are characterized by volatility, uncertainty, complexity, ambiguity, and delayed feedback. These are conditions that could be encountered by crews in off-nominal situations or during the first missions beyond low earth orbit. If findings of the earlier study are confirmed in crew-like subjects, our findings would provide additional evidence that CO2 may need to be controlled at levels that are well below current spacecraft limits. Our study will extend the earlier study to determine if crew-like subjects are similarly effected by CO2. In addition to employing the Strategic Management Simulation tool, we will use the Cognition battery of psychometric measures that are being utilized aboard the ISS. It will be important to learn, by using Cognition, if additional cognitive domains are sensitive to concentrations of CO2 at or below limits currently controlled by flight rules. While spaceflight Cognition data will greatly enhance the knowledge base related to inflight behavioral health and performance, some of the measures may be influenced by fatigue (related to sleep deprivation and or workload) and changes in circadian rhythms. Therefore our use of this battery of tests in a well-controlled, ground-based study that is free of these potential confounding influences will establish a baseline terrestrial data set against which Cognition data collected in flight may be assessed. The findings from this study will be useful to the NASA Toxicology Office and the National Research Council Committee on Toxicology, which assists NASA in setting environmental standards, for revision of the SMAC for CO2, and for designing further studies on effects of CO2 upon cognitive functions.

Scully, R. R.↗

Effects of Spaceflight Relevant Carbon Dioxide Levels on Pathogenesis Related Microbial Characteristics

Background - Spaceflight can alter microbial pathogenesis - Microgravity (Nickerson et al. 2000 Infect Immun 68(6):3147-52; Crabbe 2011 Appl Environ Mirobiol 77(4):1221-30; Gilbert 2020 NPJ Micrograv 6:4) - Radiation (Dornmayr-Pfaffenhuemer 2011 Astrobiol 11(3):199-205; Romsdahl 2020 Front Microbiol 11:931; Perrone 2020 Microorganisms 8(10):1496) - Elevated CO2 (0.4%, compared to earth at 0.04%) - The effect of slightly elevated CO2 concentrations on microbial pathogenesis has not been studied.

carbon dioxide↗

(Photo)Electrocatalytic CO 2 Reduction at the Defective Anatase TiO 2 (101) Surface

Excessive carbon dioxide (CO 2 ) emissions by combustion of fossil fuels are linked to global warming and rapid climate change. One promising route to lowering the concentration of CO 2 in the atmosphere is to reduce it to useful small molecules via photoelectrocatalytic hydrogenation, which would enable solar energy storage with a zero-carbon emission cycle and perform a more efficient separation of the photogenerated electron and hole pair than pure photocatalysis. Indeed, photoelectrocatalytic CO 2 reduction has been an intense focus of research. Using the density functional theory (DFT), we studied the CO 2 reduction reaction on the defective anatase TiO 2 (101) surface, at both the solvent/catalyst and the electrolyte/catalyst interfaces. The analysis of the electronic structure of the surface shows a contrast between the solvent/catalyst and the electrolyte/catalyst interfaces, which results in the two corresponding catalytic cycles being distinct. Furthermore, our study explains at the electronic and mechanistic levels why methanol is the main product in the presence of the electrolyte and why the overpotential is not only controlled by the reaction process but also by the diffusion process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Increasing anthropogenic methane emissions arise equally from agricultural and fossil fuel sources

Climate stabilization remains elusive, with increased greenhouse gas concentrations already increasing global average surface temperatures 1.1°C above pre-industrial levels (World Meteorological Organization 2019). Carbon dioxide (CO2) emissions from fossil fuel use, deforestation, and other anthropogenic sources reached ~ 43 billion metric tonnes in 2019 (Friedlingstein et al 2019, Jackson et al 2019). Storms, floods, and other extreme weather events displaced a record 7 million people in the first half of 2019 (IDMC 2019). When global mean surface temperature four million years ago was 2°C–3°C warmer than today (a likely temperature increase before the end of the century), ice sheets in Greenland and West Antarctica melted and parts of East Antarctica’s ice retreated, causing sea levels to rise 10–20 m (World Meteorological Organization 2019). Methane (CH4) emissions have contributed almost one quarter of the cumulative radiative forcings for CO2, CH4, and N2O (nitrous oxide) combined since 1750 (Etminan et al 2016). Although methane is far less abundant in the atmosphere than CO2, it absorbs thermal infrared radiation much more efficiently and, in consequence, has a global warming potential (GWP) ~86 times stronger per unit mass than CO2 on a 20-year timescale and 28- times more powerful on a 100-year time scale (IPCC 2014). Global average methane concentrations in the atmosphere reached ~1875 parts per billion (ppb) at the end of 2019, more than two-and-a-half times preindustrial levels (Dlugokencky 2020). The largest methane sources include anthropogenic emissions from agriculture, waste, and the extraction and use of fossil fuels as well as natural emissions from wetlands, freshwater systems, and geological sources (Kirschke et al 2013, Saunois et al 2016a, Ganesan et al 2019). Here, we summarize new estimates of the global methane budget based on the analysis of Saunois et al (2020) for the year 2017, the last year of the new Global Methane Budget and the most recent year data are fully available. We compare these estimates to mean values for the reference ‘stabilization’ period of 2000–2006 when atmospheric CH4 concentrations were relatively stable. We present data for sources and sinks and provide insights for the geographical regions and economic sectors where emissions have changed the most over recent decades.

fossil fuel sources↗

Carbon Nanotube Based Chemical Sensors for Space and Terrestrial Applications

A nanosensor technology has been developed using nanostructures, such as single walled carbon nanotubes (SWNTs), on a pair of interdigitated electrodes (IDE) processed with a silicon-based microfabrication and micromachining technique. The IDE fingers were fabricated using photolithography and thin film metallization techniques. Both in-situ growth of nanostructure materials and casting of the nanostructure dispersions were used to make chemical sensing devices. These sensors have been exposed to nitrogen dioxide, acetone, benzene, nitrotoluene, chlorine, and ammonia in the concentration range of ppm to ppb at room temperature. The electronic molecular sensing of carbon nanotubes in our sensor platform can be understood by intra- and inter-tube electron modulation in terms of charge transfer mechanisms. As a result of the charge transfer, the conductance of p-type or hole-richer SWNTs in air will change. Due to the large surface area, low surface energy barrier and high thermal and mechanical stability, nanostructured chemical sensors potentially can offer higher sensitivity, lower power consumption and better robustness than the state-of-the-art systems, which make them more attractive for defense and space applications. Combined with MEMS technology, light weight and compact size sensors can be made in wafer scale with low cost. Additionally, a wireless capability of such a sensor chip can be used for networked mobile and fixed-site detection and warning systems for military bases, facilities and battlefield areas.

Li, Jing↗