Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Calibration of Two-dimensional Floodplain Modeling in the Atchafalaya River Basin Using SAR Interferometry

Two-dimensional (2D) satellite imagery has been increasingly employed to improve prediction of floodplain inundation models. However, most focus has been on validation of inundation extent, with little attention on the 2D spatial variations of water elevation and slope. The availability of high resolution Interferometric Synthetic Aperture Radar (InSAR) imagery offers unprecedented opportunity for quantitative validation of surface water heights and slopes derived from 2D hydrodynamic models. In this study, the LISFLOOD-ACC hydrodynamic model is applied to the central Atchafalaya River Basin, Louisiana, during high flows typical of spring floods in the Mississippi Delta region, for the purpose of demonstrating the utility of InSAR in coupled 1D/2D model calibration. Two calibration schemes focusing on Manning s roughness are compared. First, the model is calibrated in terms of water elevations at a single in situ gage during a 62 day simulation period from 1 April 2008 to 1 June 2008. Second, the model is calibrated in terms of water elevation changes calculated from ALOS PALSAR interferometry during 46 days of the image acquisition interval from 16 April 2008 to 1 June 2009. The best-fit models show that the mean absolute errors are 3.8 cm for a single in situ gage calibration and 5.7 cm/46 days for InSAR water level calibration. The optimum values of Manning's roughness coefficients are 0.024/0.10 for the channel/floodplain, respectively, using a single in situ gage, and 0.028/0.10 for channel/floodplain the using SAR. Based on the calibrated water elevation changes, daily storage changes within the size of approx 230 sq km of the model area are also calculated to be of the order of 107 cubic m/day during high water of the modeled period. This study demonstrates the feasibility of SAR interferometry to support 2D hydrodynamic model calibration and as a tool for improved understanding of complex floodplain hydrodynamics

Hahn Chul Jung↗

MODIS On-Orbit Calibration and Lessons Learned

The Moderate Resolution Imaging Spectroradiometer (MODIS) is a key instrument for NASA's Earth Observing System (EOS) Terra and Aqua missions. Since launch, Terra and Aqua MODIS have successfully operated for more than 12 and 10 years, respectively, and generated an unprecedented amount of data products for the science and user community over a wide range of applications. MODIS was developed with improved design and stringent calibration requirements over its heritage sensors in order . to extend and enhance their long-term data records. Its follow-on instrument, the Visible/Infrared Imager Radiometer Suite (VIIRS), was launched on-board the Suomi National Polar-orbiting Partnership (NPP) spacecraft October 28, 2011. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.S!Jlll, and at 250m, SOOm, and lkm spatial resolutions (nadir). MODIS on-orbit calibration is provided by a set of onboard calibrators (OBC), including a solar diffuser (SO), a solar diffuser stability monitor (SDSM), a blackbody (BB), and a spectroradiometric calibration assembly (SRCA). In addition to the onboard calibrators, regular lunar observations are made by both Terra and Aqua MODIS to track their calibration stability in the reflective solar region. This tutorial session provides an overview of MODIS on-orbit calibration and characterization methodologies. It discusses challenging issues and lessons learned from sensor design, operation, calibration, and inter-comparisons. Examples of instrument on-orbit performance are illustrated with a focus on the improvements made based on various lessons learned. It is expected that MODIS experience and lessons will continue to provide valuable information for future earth observing missions/sensors.

Xiong, Jack↗

A Full-Envelope Air Data Calibration and Three-Dimensional Wind Estimation Method Using Global Output-Error Optimization and Flight-Test Techniques

A novel, efficient air data calibration method is proposed for aircraft with limited envelopes. This method uses output-error optimization on three-dimensional inertial velocities to estimate calibration and wind parameters. Calibration parameters are based on assumed calibration models for static pressure, angle of attack, and flank angle. Estimated wind parameters are the north, east, and down components. The only assumptions needed for this method are that the inertial velocities and Euler angles are accurate, the calibration models are correct, and that the steady-state component of wind is constant throughout the maneuver. A two-minute maneuver was designed to excite the aircraft over the range of air data calibration parameters and de-correlate the angle-of-attack bias from the vertical component of wind. Simulation of the X-48B (The Boeing Company, Chicago, Illinois) aircraft was used to validate the method, ultimately using data derived from wind-tunnel testing to simulate the un-calibrated air data measurements. Results from the simulation were accurate and robust to turbulence levels comparable to those observed in flight. Future experiments are planned to evaluate the proposed air data calibration in a flight environment.

Taylor, Brian R.↗

Calibration and Sequence Development Status for the Sample Analysis at Mars Investigation on the Mars Science Laboratory

The measurement goals of the Sample Analysis at Mars (SAM) instrument suite on the "Curiosity" Rover of the Mars Science Laboratory (MSL) include chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples [1,2]. SAM directly supports the ambitious goals of the MSL mission to provide a quantitative assessment of habitability and preservation in Gale crater by means of a range of chemical and geological measurements [3]. The SAM FM combined calibration and environmental testing took place primarily in 2010 with a limited set of tests implemented after integration into the rover in January 2011. The scope of SAM FM testing was limited both to preserve SAM consumables such as life time of its electromechanical elements and to minimize the level of terrestrial contamination in the SAM instrument. A more comprehensive calibration of a SAM-like suite of instruments will be implemented in 2012 with calibration runs planned for the SAM testbed. The SAM Testbed is nearly identical to the SAM FM and operates in a ambient pressure chamber. The SAM Instrument Suite: SAM's instruments are a Quadrupole Mass Spectrometer (QMS), a 6-column Gas Chromatograph (GC), and a 2-channel Tunable Laser Spectrometer (TLS). Gas Chromatography Mass Spectrometry is designed for identification of even trace organic compounds. The TLS [5] secures the C, H, and O isotopic composition in carbon dioxide, water, and methane. Sieved materials are delivered from the MSL sample acquisition and processing system to one of68 cups of the Sample Manipulation System (SMS). 59 of these cups are fabricated from inert quartz. After sample delivery, a cup is inserted into one of 2 ovens for evolved gas analysis (EGA ambient to >9500C) by the QMS and TLS. A portion of the gas released can be trapped and subsequently analyzed by GCMS. Nine sealed cups contain liquid solvents and chemical derivatization or thermochemolysis agents to extract and transform polar molecules such as amino acids, nucleobases, and carboxylic acids into compounds that are sufficiently volatile to transmit through the GC columns. The remaining 6 cups contain calibrants. SAM FM Calibration Overview: The SAM FM calibration in the Mars chamber employed a variety of pure gases, gas mixtures, and solid materials. Isotope calibration runs for the TLS utilized 13C enriched C02 standards and 0 enriched CH4. A variety of fluorocarbon compounds that spanned the entire mass range of the QMS as well as C3-C6 hydrocarbons were utilized for calibration of the GCMS. Solid samples consisting of a mixture of calcite, melanterite, and inert silica glass either doped or not with fluorocarbons were introduced into the SAM FM cups through the SAM inlet funnel/tube system.

Mahaffy, Paul R.↗

Calibration Variable Selection and Natural Zero Determination for Semispan and Canard Balances

Independent calibration variables for the characterization of semispan and canard wind tunnel balances are discussed. It is shown that the variable selection for a semispan balance is determined by the location of the resultant normal and axial forces that act on the balance. These two forces are the first and second calibration variable. The pitching moment becomes the third calibration variable after the normal and axial forces are shifted to the pitch axis of the balance. Two geometric distances, i.e., the rolling and yawing moment arms, are the fourth and fifth calibration variable. They are traditionally substituted by corresponding moments to simplify the use of calibration data during a wind tunnel test. A canard balance is related to a semispan balance. It also only measures loads on one half of a lifting surface. However, the axial force and yawing moment are of no interest to users of a canard balance. Therefore, its calibration variable set is reduced to the normal force, pitching moment, and rolling moment. The combined load diagrams of the rolling and yawing moment for a semispan balance are discussed. They may be used to illustrate connections between the wind tunnel model geometry, the test section size, and the calibration load schedule. Then, methods are reviewed that may be used to obtain the natural zeros of a semispan or canard balance. In addition, characteristics of three semispan balance calibration rigs are discussed. Finally, basic requirements for a full characterization of a semispan balance are reviewed.

Ulbrich, Norbert M.↗

Calibration of the DSCOVR EPIC Visible and NIR Channels using MODIS Terra and Aqua Data and EPIC Lunar Observations

The unique position of the Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) at the Lagrange 1 point makes an important addition to the data from currently operating low Earth orbit observing instruments. EPIC instrument does not have an onboard calibration facility. One approach to its calibration is to compare EPIC observations to the measurements from polar-orbiting radiometers. Moderate Resolution Imaging Spectroradiometer (MODIS) is a natural choice for such comparison due to its well-established calibration record and wide use in remote sensing. We use MODIS Aqua and Terra L1B 1km reflectances to infer calibration coefficients for four EPIC visible and NIR channels: 443, 551, 680 and 780 nm. MODIS and EPIC measurements made between June 2015 and 2016 are employed for comparison. We first identify favorable MODIS pixels with scattering angle matching temporarily collocated EPIC observations. Each EPIC pixel is then spatially collocated to a subset of the favorable MODIS pixels within 25 km radius. Standard deviation of the selected MODIS pixels as well as of the adjacent EPIC pixels is used to find the most homogeneous scenes. These scenes are then used to determine calibration coefficients using a linear regression between EPIC counts/sec and reflectances in the close MODIS spectral channels. We present thus inferred EPIC calibration coefficients and discuss sources of uncertainties. The lunar EPIC observations are used to calibrate EPIC O2 absorbing channels (688 and 764 nm), assuming that there is a small difference between moon reflectances separated by approx.10 nm in wavelength provided the calibration factors of the red (680 nm) and near-IR (780 nm) are known from comparison between EPIC and MODIS.

Geogdzhayev, Igor V.↗

A Consistent EPIC Visible Channel Calibration using VIIRS and MODIS as a Reference

The Earth Polychromatic Imaging Camera (EPIC) aboard the Deep Space Climate Observatory (DSCOVR) satellite constantly images the sunlit disk of Earth from the Lagrange-1 (L1) point in 10 spectral channels spanning the UV, VIS, and NIR spectrums. Recently, the DSCOVR EPIC team has publicly released version 2 dataset, which has implemented improved navigation, stray-light correction, and flat-fielding of the CCD array. The EPIC 2-year data record must be well-calibrated for consistent cloud, aerosol, trace gas, land use and other retrievals. Because EPIC lacks onboard calibrators, the observations made by EPIC channels must be calibrated vicariously using the coincident measurements from radiometrically stable instruments that have onboard calibration systems. MODIS and VIIRS are best-suited instruments for this task as they contain similar spectral bands that are well-calibrated onboard using solar diffusers and lunar tracking. We have previously calibrated the EPIC version 1 dataset by using EPIC and VIIRS angularly matched radiance pairs over both all-sky ocean and deep convective clouds (DCC). We noted that the EPIC image required navigations adjustments, and that the EPIC stray-light correction provided an offset term closer to zero based on the linear regression of the EPIC and VIIRS ray-matched radiance pairs. We will evaluate the EPIC version 2 navigation and stray-light improvements using the same techniques. In addition, we will monitor the EPIC channel calibration over the two years for any temporal degradation or anomalous behavior. These two calibration methods will be further validated using desert and DCC invariant Earth targets. The radiometric characterization of the selected invariant targets is performed using multiple years of MODIS and VIIRS measurements. Results of these studies will be shown at the conference.

Haney, C. O.↗

Calibrating X-ray Imaging Devices for Accurate Intensity Measurement

The purpose of the project presented is to develop methods to accurately calibrate X-ray imaging devices. The approach was to develop X-ray source systems suitable for this endeavor and to develop methods to calibrate solid state detectors to measure source intensity. NSTec X-ray sources used for the absolute calibration of cameras are described, as well as the method of calibrating the source by calibrating the detectors. The work resulted in calibration measurements for several types of X-ray cameras. X-ray camera calibration measured efficiency and efficiency variation over the CCD. Camera types calibrated include: CCD, CID, back thinned (back illuminated), front illuminated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Accuracy Signal Validation Framework for Sensor Calibration Assessment in NPPs

Effective and efficient health management of sensing channels and instrumentation supports reliable and accurate process monitoring capacities in any industry. Current practice in the nuclear industry relies on periodic calibration assessment and correction activities. This time based maintenance technique consists of three steps: i) removal of sensor to a test environment, ii) testing and recalibration, and iii) reinstallation of sensor into its working environment. This procedure is highly labor intensive, adds to the outage cost and timeline, and contributes to worker radiation exposure and ALARA requirements. Furthermore, the human element contributes to error factors in all stages of the procedure. The effectiveness of this calibration procedure after sensors are returned to working environmental variables also raises concerns, and the practicability of this periodic approach is uncertain for future reactor designs with longer operating cycles between refueling outages. Studies indicate that periodic calibration assessment find only 10% of sensing instrumentations with calibration issues during a single outage (18- 24 months), meaning at least 90% of sensors are undergoing unnecessary maintenance actions. This provides an opportunity to maintain the current levels of safety and functional integrity with fewer, more targeted maintenance actions and lower economic burden. Performance-based maintenance planning shows much promise over current periodic maintenance approaches. Specifically, online monitoring (OLM) utilizes the continually collected process data to non-intrusively monitor the calibration status of process instrumentation and detect the onset of de-calibration, thereby minimizing the number of recalibration procedures required. Ultimately, this can lead to termination of time based recalibration at NPPs. OLM utilizes the process measurements made for process monitoring and control to evaluate the calibration status of the sensors and instrumentation making the measurements. OLM can detect and differentiate sensor faults and process anomalies, thus providing a valuable tool to suit the industry's and regulatory body's requirements. Though supported by more than a decade of research, OLM for sensor calibration assessment is yet to be implemented in the US fleet due to regulatory requirements and constraints. As shown in Figure 1, OLM utilizes process data to train statistical models that predict normal, error-free process behavior. Measured process values are compared with error-corrected predictions to ascertain the presence of faults. The reliability of OLM is dependent on the quality of its predictions, measured in part by the uncertainty in these predictions. This research develops a framework to accurately quantify the prediction uncertainty based on Bayesian inference techniques to provide the required confidence levels for OLM systems. The expected outcomes include signal validation by high-accuracy, high-confidence uncertainty quantification for variable sensor types and operating ranges. Furthermore, the framework will facilitate fault detection capacities and so-called virtual sensors, a capability to replace faulty sensor measurements with error-corrected values when a sensor fault is detected. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous and Constrained Calibration of Multiple Hyperspectral Images Through a New Generalized Empirical Line Model

The empirical line (EL) calibration method is commonly used for atmospheric correction of remotely sensed spectral images and recovery of surface reflectance. The current EL-based methods are applicable to calibrate only single images. Therefore, the use of the EL calibration is impractical for imaging campaigns, where many (partially overlapped) images are acquired to cover a large area. In addition, the EL results are unconstrained and an undesired reflectance with negative values or larger than 100% can be obtained. In this paper, we use the standard EL model to formulate a new generalized empirical line (GEL) model. Based on the GEL, we present a novel method for simultaneous and constrained calibration of multiple images. This new method allows for calibration through multiple image constrained empirical line (MIcEL) and three additional calibration modes. Given a set of images, we use the available ground targets and automatically extracted tie points between overlapping images to calibrate all the images in the set simultaneously. Quantitative and visual assessments of the proposed method were carried out relatively to the off-the-shelf method quick atmospheric correction (QUAC), using real hyperspectral images and field measurements. The results clearly show the superiority of MIcEL with respect to the minimization of the difference between the reflectance values of the same object in different overlapping images. An assessment of the absolute accuracy, with respect to 11 field measurement points, shows that the accuracy of MIcEL, with an average mean absolute error (MAE) of ~11%, is comparable with respect to the QUAC.

47 OTHER INSTRUMENTATION↗

SU-E-T-298: Small Field Total Scatter Factors Using a Commercial Scintillator Detector: Calibration Parameters Are Not Independent of Field Size

Purpose: To evaluate the accuracy in total scatter factor (Sc,p) determination for small fields using commercial plastic scintillator detector (PSD). The manufacturer's spectral discrimination method to subtract Cerenkov light from the signal is discussed. Methods: Sc,p for field sizes ranging from 0.5 to 10 cm were measured using PSD Exradin (Standard Imaging) connected to two channel electrometer measuring the signals in two different spectral regions to subtract the Cerenkov signal from the PSD signal. A Pinpoint ionisation chamber 31006 (PTW) and a non-shielded semiconductor detector EFD (Scanditronix) were used for comparison. Measures were performed for a 6 MV X-ray beam. The Sc,p are measured at 10 cm depth in water for a SSD=100 cm and normalized to a 10'10 cm{sup 2} field size at the isocenter. All detectors were placed with their symmetry axis parallel to the beam axis.We followed the manufacturer's recommended calibration methodology to subtract the Cerenkov contribution to the signal as well as a modified method using smaller field sizes. The Sc,p calculated by using both calibration methodologies were compared. Results: Sc,p measured with the semiconductor and the PinPoint detectors agree, within 1.5%, for field sizes between 10'10 and 1'1 cm{sup 2}. Sc,p measured with the PSD using the manufacturer's calibration methodology were systematically 4% higher than those measured with the semiconductor detector for field sizes smaller than 5'5 cm{sup 2}. By using a modified calibration methodology for smalls fields and keeping the manufacturer calibration methodology for fields larger than 5'5cm{sup 2} field Sc,p matched semiconductor results within 2% field sizes larger than 1.5 cm. Conclusion: The calibration methodology proposed by the manufacturer is not appropriate for dose measurements in small fields. The calibration parameters are not independent of the incident radiation spectrum for this PSD. This work was partially financed by grant 2012 of Barcelona board of the AECC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-202-07: Protocol and Hardware for Improved Flood Field Calibration of TrueBeam FFF Cine Imaging

Purpose: Flattening filter free photon energies are commonly used for high dose treatments such as SBRT, where localization accuracy is essential. Often, MV cine imaging may be employed to verify correct localization. TrueBeam Electronic Portal Imaging Devices (EPIDs) equipped with the 40×30cm{sup 2} Image Detection Unit (IDU) are prone to image saturation at the image center especially for higher dose rates. While saturation often does not occur for cine imaging during treatment because the beam is attenuated by the patient, the flood field calibration is affected when the standard calibration procedure is followed. Here we describe the hardware and protocol to achieve improved image quality for this model of TrueBeam EPID. Methods: A stainless steel filter of uniform thickness was designed to have sufficient attenuation to avoid panel saturation for both 6XFFF and 10XFFF at the maximum dose rates (1400 MU/min & 2400 MU/min, respectively). The cine imaging flood field calibration was then acquired with the filter in place for the FFF energies under the standard calibration geometry (SDD=150cm). Image quality during MV cine was assessed with & without the modified flood field calibration using a low contrast resolution phantom and an anthropomorphic phantom. Results: When the flood field is acquired using the standard procedure (no filter in place), a pixel gain artifact is clearly present in the image center (r=3cm for 10XFFF at 2400 MU/min) which appears similar to and may be mis-attributed to panel saturation in the subject image. The artifact obscured all low contrast inserts at the image center and was also visible on the anthropomorphic phantom. Using the filter for flood field calibration eliminated the artifact. Conclusion: Use of a modified flood field calibration procedure improves image quality for cine MV imaging with TrueBeams equipped with the 40×30cm{sup 2} IDU.

60 APPLIED LIFE SCIENCES↗

Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Calibration System

As a continuing effort to increase the calibration accuracy of the AVIRIS data a number of recent improvements have been implemented and are in the process of being tested during the 1994 flight season. These include the following innovations: A direct observation of a laboratory radiance standard is now used to double check the wide field-of-view calibration via an integrating sphere source. Launch site field calibration of the AVIRIS sensor is now being planned to augment the laboratory and inflight calibration. Modification to a dry air conditioning unit has been made to enable ground calibration at flight operating temperatures. One hundred lines of dark imagery has been added to the end of each flight line to assist in the analysis and removal of residual coherent noise. The intensity of the onboard calibration lamp has been modified to improve response in the blue end of the spectrum. Novel spectral filters have been installed in the onboard calibration source.

Airborne Visible/Infrared Imaging Spectrometer Cal↗

MODIS and VIIRS Calibration History and Future Outlook

The MODIS is a key instrument for NASA’s EOS program, currently operated onboard the Terra and Aqua spacecraft launched in 1999 and 2002, respectively. The VIIRS is a MODIS follow-on instrument for the JPSS program. Adding to the ones operated onboard the S-NPP and NOAA-20 satellites launched in 2011 and 2017, respectively, three nearly identical VIIRS instruments will also be launched. This will enable the data records from MODIS and VIIRS to be extended beyond 2040. In addition to various applications and scientific studies of the Earth’s system, long-term data records from MODIS and VIIRS observations will greatly benefit the space-based climate observing system. This is attributed to the high-quality measurements and extensive calibration efforts, from pre-launch to post-launch. This paper provides an overview of MODIS and VIIRS calibration history and approaches applied to establish and maintain sensor calibration traceability and accuracy. It illustrates calibration and performance issues through different phases of the mission using examples derived from ground testing equipment, on-board calibrators, and other calibration targets. Moreover, discussed in this paper are outstanding challenges and future efforts to maintain and improve sensor calibration stability and long-term data quality, and to better support the space-based climate observing system.

MODIS↗

Terra MODIS: 20 years of on-orbit calibration and performance

For nearly 20 years, Terra MODIS observations have generated a broad range of data products, enabling the remote sensing community and users worldwide for their studies of many key geophysical parameters of the Earth’s system. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.4 μm, that are calibrated by a set of on-board calibrators (OBC). Also contributed to sensor on-orbit calibration and characterization are near monthly-scheduled lunar observations and long-term trends of sensor responses over select ground targets. The quality of MODIS data products relies strongly on the dedicated efforts to the operate instrument, derive and update calibration parameters, and improve calibration strategies and algorithms in order to address on-orbit changes of sensor characteristics and its OBC functions. This paper provides an overview of Terra MODIS on-orbit operation and calibration activities over the last 20 years, including changes made to extend and preserve instrument and OBC functions and their implementation strategies. It illustrates sensor on-orbit performance using data from its OBC, lunar observations, and select ground targets and discusses major changes in sensor characteristics and corrections applied to the L1B algorithms or updates of calibration look-up tables (LUTs). Also described in this paper are lessons learned from Terra MODIS and future efforts to further extend its long-term data records.

Terra↗

Determination of elemental impurities in plastic calibration standards using laser induced breakdown spectroscopy

Dual-energy computed tomography (CT) scanning is a rapidly emerging imaging technique employed in nondestructive evaluation of various materials. CT has been used for characterizing rocks and visualizing multiphase flow through rocks for over 25 years. The most common technique for dual-energy CT scanning relies on homogeneous calibration standards to produce the most accurate decoupled data. However, the use of calibration standards with impurities increases the probability of error in the reconstructed data and results in poor rock characterization. Laser-induced breakdown spectroscopy was used to determine impurity concentration in a set of commercially purchased calibration standards used in dual-energy scanning for material identification with coal samples. Two calibration models were developed by using univariate calibration with the internal ratio method and multiple linear regression. Seven elements (Al, Fe, Mg, Na, Ni, Sr, and Ti) were examined in five different samples containing varying amounts of each ion to compare calibration from univariate data analysis and from multivariate data analysis. The contaminant concentrations were also measured by a commercially available inductively coupled plasma optical emission spectroscopy instrument, and the data were used as a reference in developing calibration curves for a modified version of the single linear regression model and the multiple linear regression model.

01 COAL, LIGNITE, AND PEAT↗

Development of pseudo-random binary gratings and arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable flair. A major difficulty in using surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. Therefore, accurate calibration of profilometers, the understanding of their MTF limitations, and cross calibration between tools represents a considerable challenge for quantitative optical metrology. In previous work the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudo-random (BPR) gratings. Here, they present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocol. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat Power Spectrum Density (PSD). Three different BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Figure 1 shows the fabrication sequence. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. Figure 2 shows representative scanning probe height data for the 400 nm BPR sample. Figure 2 shows the raw Power Spectral Density for 5 different objectives. They demonstrate that the two dimensional BPR array is a very effective calibration standard. However, departures from ideal, such as square sidewall, and uniform etch depth ultimately can limit the accuracy of the calibration. The effects of fabrication imperfections on the efficiency of calibration will be discussed.

36 MATERIALS SCIENCE↗