Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Calibration of calorimetric measurement in a liquid argon time projection chamber

The liquid argon time projection chamber provides high-resolution event images and excellent calorimetric resolution for studying neutrino physics and searching for beyond-standard-model physics. In this article, we review the main physics processes that affect detector response, including the electronics and field responses, space charge effects, electron attachment to impurities, diffusion, and recombination. We describe methods to measure those effects, which are used to calibrate the detector response and convert the measured raw analog-to-digital converter (ADC) counts into the original energy deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy Reconstruction and Calibration of the MicroBooNE LArTPC

MicroBooNE uses a liquid argon time projection chamber (LArTPC) for simultaneous tracking and calorimetry. Neutrino oscillation experiments plan to use LArTPCs over the next several decades. A challenge for these current and future experiments lies in characterizing detector performance and reconstruction capabilities with thorough associated systematic uncertainties. This work includes updates related to LArTPC detector physics challenges by reviewing MicroBooNE’s recent publications on calorimetry and its applications. Highlights include discussions on signal processing, calorimetric calibration, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Grids of Pure-hydrogen White Dwarf NLTE Model Atmospheres and the HST/STIS Flux Calibration

Nonlocal thermodynamic equilibrium (NLTE) calculations of hot white dwarf (WD) model atmospheres are the cornerstone of modern flux calibrations for the Hubble Space Telescope and for the CALSPEC database. These theoretical spectral energy distributions (SEDs) provide the relative flux versus wavelength, and only the absolute flux level remains to be set by reconciling the measured absolute flux of Vega in the visible with the Midcourse Space Experiment values for Sirius in the mid-IR. The most recent SEDs calculated by the tlusty and tmap NLTE model atmosphere codes for the primary WDs G191-B2B, GD 153, and GD 71 show improved agreement to 1% from 1500 Å to 30 μm, in comparison to the previous 1% consistency only from 2000 Å to 5 μm. These new NLTE models of hot WDs now provide consistent flux standards from the far UV to the mid-IR.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibrating the Galactic Cepheid Period–Luminosity Relation from the Maximum-likelihood Technique

We present a realization of the maximum-likelihood technique, which is one of the latest modifications of the Baade–Becker–Wesselink method. Our approach is based on nonlinear calibrations of the effective temperature and bolometric correction, which take into account metallicity and surface gravity. It allows one to estimate the key Cepheid parameters, the distance modulus, and the interstellar reddening, combining photometric and spectroscopic data (including the effective temperature data). This method is applied to a sample of 44 Galactic Cepheids for which multiphase temperature measurements are available. The additional data correction is performed to subtract the impact of the component in binary/multiple systems. We also study the effect of shock waves, whose presence in the stellar atmosphere distorts the observational data and leads to systematic errors in the obtained parameters. We determine the optimal restriction on the input data to eliminate this effect. This restriction provides accurate period–radius and period–luminosity relations that are consistent with the results in previous studies. We found the following relations: log R = (0.68 ± 0.03) · log P + (1.14 ± 0.03), M {sub v} = − (2.67 ± 0.16) · (log P − 1) − (4.14 ± 0.05).

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration and Validation of a Mechanistic COVID-19 Model for Translational Quantitative Systems Pharmacology – A Proof-of-Concept Model Development for Remdesivir

With the ongoing global pandemic of coronavirus disease 2019 (COVID-19), there is an urgent need to accelerate the traditional drug development process. Many studies identified potential COVID-19 therapies based on promising nonclinical data. However, the poor translatability from nonclinical to clinical settings has led to failures of many of these drug candidates in the clinical phase. In this study, we propose a mechanism-based, quantitative framework to translate nonclinical findings to clinical outcome. Adopting a modularized approach, this framework includes an in silico disease model for COVID-19 (virus infection and human immune responses) and a pharmacological component for COVID-19 therapies. Here, the disease model was able to reproduce important longitudinal clinical data for patients with mild and severe COVID-19, including viral titer, key immunological cytokines, antibody responses, and time courses of lymphopenia. Using remdesivir as a proof-of-concept example of model development for the pharmacological component, we developed a pharmacological model that describes the conversion of intravenously administered remdesivir as a prodrug to its active metabolite nucleoside triphosphate through intracellular metabolism and connected it to the COVID-19 disease model. After being calibrated with the placebo arm data, our model was independently and quantitatively able to predict the primary endpoint (time to recovery) of the remdesivir clinical study, Adaptive Covid-19 Clinical Trial (ACTT). Our work demonstrates the possibility of quantitatively predicting clinical outcome based on nonclinical data and mechanistic understanding of the disease and provides a modularized framework to aid in candidate drug selection and clinical trial design for COVID-19 therapeutics.

60 APPLIED LIFE SCIENCES↗

Robust calibration of non-perturbative models with history matching

We apply, for the first time, Bayes Linear Emulation and History Matching to the calibration of non-perturbative models in Monte Carlo event generators. In contrast to the usual approach of "Monte Carlo tuning", History Matching does not result in best-fit plus ellipsoidal parameter uncertainty estimates but instead identifies all parameter space regions that are consistent with data. This approach leads to a systematic and robust quantification of parametric uncertainties in the models, especially in those challenging cases where different, possibly disjoint, regions of parameter space deliver similar results, which are usually not properly treated with current methodology. We highlight the power of this method with the hadronisation models available through Sherpa : the built-in cluster fragmentation Ahadic and string fragmentation through an interface to Pythia .

Iskauskas, Andrew [Durham U. (main)] (ORCID:000000↗

Calibration of cohesive parameters for fracture test simulations of sub-sized bend specimens of AM steels

In this work, crack extensions in sub-sized side-grooved bend specimens of AM steels are examined with changing cohesive parameters. Two-dimensional FE analyses are first conducted to simulate crack extensions by nodal release. The simulation results indicate the near-tip maximum opening stress and separation work rate increase and then slightly decrease for the bend specimens. The hydrogen-charged bend specimens have lower near-tip maximum opening stresses and average separation work rates than those of the uncharged bend specimens. The changing near-tip maximum opening stresses and the separation work rates with increasing crack extension are determined as references for the changing cohesive strengths and energies, respectively. Two-dimensional FE analyses with different changing cohesive parameters are then performed. The simulation results with calibrated cohesive parameters can match well with the test results. The hydrogen-charged specimens have the lower changing cohesive strength vs crack growth curves compared with those of the uncharged specimens. The hydrogen-charged specimens have either lower or similar changing cohesive energy vs crack growth curves compared with those of the uncharged specimens. Finally, a three-dimensional FE analysis is conducted to simulate crack extension by nodal release in one bend specimen to examine the stress triaxialities in front of the growing crack fronts at different locations from the center plane to the planes near the side groove front with increasing crack extension to identify possible physical reasons for the changing cohesive parameters.

36 MATERIALS SCIENCE↗

Evaluation and calibration of MERRA-2 and CAMS reanalysis for PM 2.5 in a semi-urbanized area in the south of the Amazon

Air pollution has significant implications for the climate and poses irreversible risks to human health. The Amazon region of Brazil is severely affected by biomass burning (BB) emissions, yet air quality monitoring remains highly inadequate. Given the scarcity of surface-based observations, reanalysis models have become essential tools for assessing air pollution. Although MERRA-2 and CAMS PM 2.5 products are widely utilized, their validation and comprehensive evaluation for the Amazon Basin remain limited. Here, this study assesses the performance of these products in a semi-urbanized region in the southern Amazon. The calibrated time series was employed to analyze PM 2.5 concentrations from 2003 to 2023. Our results showed satisfactory performance of both products for the 24-h averages of PM 2.5 , with linear correlations above 0.76. However, it was found that both products overestimate surface concentrations. MERRA-2 performed better, with approximately 30% lower bias than CAMS. Time series analysis showed that the study area is strongly impacted by emissions BB in the dry period, mainly in August and September. Furthermore, our findings indicate a positive trend in increasing PM 2.5 concentrations, with a notable rise observed since 2014. The average PM 2.5 levels frequently exceed the daily air quality guidelines established by the WHO in 2021. It has been estimated that the population of this region is exposed to concentrations above 15 μg.m -3 , on average, more than 30 days per year. Our results contribute to the evaluation of MERRA-2 and CAMS products for Amazon and provide a corrected estimate for surface PM 2.5 . Recent concerns about air quality and the implementation of new surface monitoring networks may improve the evaluation of reanalysis products. In the short term, the need for this information makes our assessments indispensable.

54 ENVIRONMENTAL SCIENCES↗

Calibrating hypersonic turbulence flow models with the HIFiRE-1 experiment using data-driven machine-learned models.

In this paper we study the efficacy of combining machine-learning methods with projection-based model reduction techniques for creating data-driven surrogate models of computationally expensive, high-fidelity physics models. Such surrogate models are essential for many-query applications e.g., engineering design optimization and parameter estimation, where it is necessary to invoke the high-fidelity model sequentially, many times. Surrogate models are usually constructed for individual scalar quantities. However there are scenarios where a spatially varying field needs to be modeled as a function of the model’s input parameters. Here we develop a method to do so, using projections to represent spatial variability while a machine-learned model captures the dependence of the model’s response on the inputs. The method is demonstrated on modeling the heat flux and pressure on the surface of the HIFiRE-1 geometry in a Mach 7.16 turbulent flow. The surrogate model is then used to perform Bayesian estimation of freestream conditions and parameters of the SST (Shear Stress Transport) turbulence model embedded in the high-fidelity (Reynolds-Averaged Navier–Stokes) flow simulator, using shock-tunnel data. The paper provides the first-ever Bayesian calibration of a turbulence model for complex hypersonic turbulent flows. We find that the primary issues in estimating the SST model parameters are the limited information content of the heat flux and pressure measurements and the large model-form error encountered in a certain part of the flow.

42 ENGINEERING↗

A comparative study of calibration techniques for finite strain elastoplasticity: Numerically-exact sensitivities for FEMU and VFM

Accurate identification of material parameters is crucial for predictive modeling in computational mechanics. Here, the two primary approaches in the experimental mechanics community for calibration from full-field digital image correlation data are known as finite element model updating (FEMU) and the virtual fields method (VFM). In VFM, the objective function is a squared mismatch between internal and external virtual work or power. In FEMU, the objective function quantifies the weighted mismatch between model predictions and corresponding experimentally measured quantities of interest. It is minimized by iteratively updating the parameters of an FE model. While FEMU is seen as more flexible, VFM is commonly used instead of FEMU due to its considerably greater computational expense. However, comparisons between the two methods usually involve approximations of gradients or sensitivities with finite difference schemes, thereby making direct assessments difficult. Hence, in this study, we compare VFM and FEMU in the context of numerically-exact sensitivities obtained through local sensitivity analyses and the application of automatic differentiation software. To this end, we conduct a series of test cases to assess both methods under practical challenges using a finite strain elastoplasticity model.

Automatic differentiation↗

Towards robust autonomous impedance spectroscopy analysis: A calibrated hierarchical Bayesian approach for electrochemical impedance spectroscopy (EIS) inversion

Distribution-based analyses, such as the distribution of relaxation times (DRT) and the distribution of diffusion times (DDT), present model-free alternatives to equivalent circuit modeling for analysis of electrochemical impedance spectroscopy (EIS) data. However, reconstructing such distributions from noisy impedance data is an ill-posed problem that must be solved with specialized inversion algorithms, requiring careful control and tuning. Furthermore, most inversion algorithms developed to date can only solve problems of limited complexity. Herein, we present a new hierarchical Bayesian method for EIS inversion, leveraging efficient algorithms for optimization and Hamiltonian Monte Carlo (HMC) sampling to solve models of arbitrary complexity. We overcome the challenge of ad-hoc parameter tuning by encoding intrinsic characteristics of the DRT and DDT into flexible prior distributions and “pre-calibrating” the model to simulated data. This approach is versatile, highly robust to noise, and provides quantitative estimates of both the error structure of the data and the uncertainty in the recovered distributions. The model is validated with simulated data to demonstrate accurate recovery of the DRT and the DDT. The method also shows promise for simultaneous recovery of multiple distributions, raising the intriguing possibility of semi-autonomous EIS analysis and ad-hoc model construction. Finally, the practical utility of the method is illustrated with experimental data. Throughout, we draw comparisons to several recently published EIS inversion methodologies.

36 MATERIALS SCIENCE↗

Calibrating Synchronous-Generator-Interfaced DG Models in Microgrids Using Multiple Event Data

Microgrids, consisting of distributed generators (DGs), loads, and energy storage systems, play an important role in future smart grids. In order to evaluate how microgrids operate and their dynamic response, it is necessary to develop accurate dynamic models of DGs in microgrids. This paper proposes a systematic method to calibrate synchronous-generator-interfaced DG models. Challenges associated with model validation in microgrids are analyzed. Underlying parameters are categorized into two groups, i.e., the steady-state parameters and time constants, which are estimated in two successive stages using multiple event data. This methodology ensures that the validated model with the estimated parameters are applicable for all events. A modified unscented Kalman filter (UKF) is proposed to deal with the cases in which measurement of power angle is unavailable. The effectiveness of the proposed method is validated using field test data of a 2.6 MVA diesel generator in a real microgrid.

Wang, Zhiwen↗

Flow boiling transient critical heat flux tests with stainless steel and FeCrAl: Transient correlation implementation, model calibration, and sensitivity analysis

In this study, steady-state and transient internal-flow critical heat flux (CHF) experiments were carried out under two flow conditions, at atmospheric pressure, on 316 stainless steel (316-SS) and iron-chromium-aluminum (FeCrAl) tubes. Slow power transients at a low mass flow (300 kg/m 2 - s) with very low subcooling (X e =-0.0054) generated premature CHFs, which were prevented by faster power transients and high mass flow (1000 kg/m 2 - s). The measured transient CHFs increased linearly with increasing power transients, compared with the steady-state CHF. Yet, the wall superheat at the CHFs decreased with faster power transients. Transient CHF correlations highlighting heterogeneous spontaneous nucleation were calibrated to the measured CHFs and compared with other existing correlations. Transient CHF multipliers were acquired from pool and flow boiling empirical CHF correlations that were generated. The multipliers were applied to the RELAP5-3D nuclear system code to analyze the discrepancies between the measured data and the predicted CHF and post-CHF behavior, which improved peak cladding temperature predictions by 24.6%. A variance-based global sensitivity study perturbing the experimental uncertainties and cladding material thermal properties showed the diminishing influence of flow boiling heat transfer with increasing power transients, highlighting the significance of the volumetric heat capacity for the cladding integrity during transients. Transient CHF correlations were applied to the most limiting design basis accident: a hot-zero-power reactivity-initiated accident on a generic pressurized water reactor RELAP5-3D model.

36 MATERIALS SCIENCE↗

An automated QC station for the calibration of the Mu2e calorimeter readout units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. Here, in this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ground calibration and in-flight commissioning of the Gamma-Ray and Neutron Spectrometer (GRNS) for NASA’s Psyche mission

NASA's Psyche spacecraft is currently enroute to the asteroid 16 Psyche, where it will perform an orbital investigation focused on determining the nature of the asteroid. A key part of this investigation is measurements of elemental composition to determine if the asteroid is rich in iron-nickel metal. To that end, the Psyche spacecraft payload includes a Gamma-Ray and Neutron Spectrometer (GRNS). GRNS is composed of two subsystems; a Gamma-Ray Spectrometer (GRS) with a high-purity germanium γ-ray sensor surrounded by a borated plastic scintillator Anti-Coincidence Shield (ACS), and a Neutron Spectrometer (NS) with three 3 He-filled gas proportional counters that are sensitive to different neutron energy regimes. We describe results from the pre-launch calibration campaign, along with early in-flight results from post-launch instrument commissioning. The information detailed here is focused on providing future users of GRNS data with the information needed to properly interpret the observations from the instrument.

Peplowski, Patrick N. [Johns Hopkins Univ., Baltim↗

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection↗

Projecting Permafrost Thaw of Sub-Arctic Tundra With a Thermodynamic Model Calibrated to Site Measurements

Northern circumpolar permafrost thaw affects global carbon cycling, as large amounts of stored soil carbon becomes accessible to microbial breakdown under a warming climate. The magnitude of carbon release is linked to the extent of permafrost thaw, which is locally variable and controlled by soil thermodynamics. Soil thermodynamic properties, such as thermal diffusivity, govern the reactivity of the soil-atmosphere thermal gradient, and are controlled by soil composition and drainage. In order to project permafrost thaw for an Alaskan tundra experimental site, we used seven years of site data to calibrate a soil thermodynamic model using a data assimilation technique. The model reproduced seasonal and interannual temperature dynamics for shallow (5–40 cm) and deep soil layers (2–4 m), and simulations of seasonal thaw depth closely matched observed data. The model was then used to project permafrost thaw at the site to the year 2100 using climate forcing data for three future climate scenarios (RCP 4.5, 6.0, and 8.5). Minimal permafrost thawing occurred until mean annual air temperatures rose above the freezing point, after which we measured over a 1 m increase in thaw depth for every 1 °C rise in mean annual air temperature. Under no projected warming scenario was permafrost remaining in the upper 3 m of soil by 2100. We demonstrated an effective data assimilation method that optimizes parameterization of a soil thermodynamic model. The sensitivity of local permafrost to climate warming illustrates the vulnerability of sub-Arctic tundra ecosystems to significant and rapid soil thawing.

54 ENVIRONMENTAL SCIENCES↗

Exploring DFT+U parameter space with a Bayesian calibration assisted by Markov chain Monte Carlo sampling

Abstract The density-functional theory is widely used to predict the physical properties of materials. However, it usually fails for strongly correlated materials. A popular solution is to use the Hubbard correction to treat strongly correlated electronic states. Unfortunately, the values of the Hubbard U and J parameters are initially unknown, and they can vary from one material to another. In this semi-empirical study, we explore the U and J parameter space of a group of iron-based compounds to simultaneously improve the prediction of physical properties (volume, magnetic moment, and bandgap). We used a Bayesian calibration assisted by Markov chain Monte Carlo sampling for three different exchange-correlation functionals (LDA, PBE, and PBEsol). We found that LDA requires the largest U correction. PBE has the smallest standard deviation and its U and J parameters are the most transferable to other iron-based compounds. Lastly, PBE predicts lattice parameters reasonably well without the Hubbard correction.

36 MATERIALS SCIENCE↗