Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Seismic isolation: A pathway to standardized advanced nuclear reactors

Standardizing advanced nuclear reactors is a pathway to substantially reducing their overnight capital cost and achieving parity with other power sources, including renewables and fossil fuels. The seismic load case has thwarted standardization of nuclear power plants because site-specific seismic hazard and local near-surface geology has triggered soil-structure-interaction analysis, design, equipment qualification, regulatory review, and licensing, ensuring that each build is different. To achieve standardized or site-independent certified advanced reactor designs, the impact of the seismic load case on the engineering and construction cost and time must be substantially mitigated. Seismic isolation is a mature technology that has been used for more than 30 years in non-nuclear sectors to substantially reduce earthquake demands in buildings and other infrastructure. In this paper, seismic isolation is used to enable standardization of advanced reactor designs, aimed at the complete re-use of a site-independent, certified design and repeated procurement of safety-class equipment. A pathway to standardized designs using seismic isolation is demonstrated for two fundamentally different advanced reactors: a molten salt reactor and a high temperature gas reactor. Each reactor building is equipped with three specialized pieces of safety-class equipment, namely, a reactor vessel, a steam generator, and a control rod drive mechanism housing that is attached to the reactor head. Analysis is performed per ASCE and ASME standards to design the buildings and the equipment for two base conditions: conventional (fixed base) and base isolated. The impact of the seismic load case is characterized for the reinforced concrete walls in the buildings and for the equipment, measured using vessel wall thickness and horizontal accelerations. Here the analysis results show that the fixed-base buildings, designed for a site of low seismic hazard (peak ground acceleration, PGA = 0.15 g) could be constructed at a site of much greater seismic hazard (PGA = 0.7 g) if seismic base isolation is employed. Importantly, the scope of the site-specific analysis, design, and qualification would be limited to the seismic isolators and the isolated substructure, drastically reducing plant-specific engineering, review, and licensing, and time to construction start. Regulatory challenges and opportunities with standardized reactor designs are identified.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

In cooperation with the Building America Program, The Levy Partnership explored a variety of options to reduce space-conditioning energy consumption, working with partners to design, manu- facture, and build test homes in three states. The Levy Partnership tested the use of minisplit ductless heat pumps in combi- nation with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The team set out to achieve 50% less energy consumption, compared to the 2009 International Energy Conservation Code, while maintaining home afford- ability and thermal comfort. The strategy also included a highly efficient thermal envelope to reduce space-conditioning loads.

30 DIRECT ENERGY CONVERSION↗

2025 Intern Poster

The Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) houses the largest U.S. inert atmosphere hot cell for nuclear material research. Key features include the precision gamma scanning (PGS), Fuel Accident Condition Simulator (FACS), Neutron Radiography Reactor (NRAD), and the focus of this project, the Metallograph Loading Cell (MET Cell). The MET Cell performs tests on spent nuclear fuel, such as microhardness testing, microscopy, and neutron radiography. However, the MET Cell’s existing pressure and lighting control systems are outdated and inefficient, with inadequate documentation for system changes over time. This project aims to design a new automated control system for the MET Cell, ensuring longevity (minimum ten years), ease of troubleshooting/repair, and integration into the building monitoring system. The design process addressed challenges such as space restrictions, varied voltages within enclosures, sourcing new components, and security limitations. Compliance with NFPA 70, UL508A, MFC Physical Security, and INL Engineering standards was essential. The project involves repurposing an existing PLC to manage lighting and pressure control using digital and analog signals, simplifying wiring, and ensuring thorough documentation for future reference.

42 - ENGINEERING↗

Automatic Digitization and Orientation of Scanned Mesh Data for Floor Plan and 3D Model Generation

This paper describes a novel approach for generating accurate floor plans and 3D models of building interiors using scanned mesh data. Unlike previous methods, which begin with a high resolution point cloud from a laser range-finder, our approach begins with triangle mesh data, as from a Microsoft HoloLens. It generates two types of floor plans, a “pen-and-ink” style that preserves details and a drafting-style that reduces clutter. It processes the 3D model for use in applications by aligning it with coordinate axes, annotating important objects, dividing it into stories, and removing the ceiling. Its performance is evaluated on commercial and residential buildings, with experiments to assess quality and dimensional accuracy. Our approach demonstrates promising potential for automatic digitization and orientation of scanned mesh data, enabling floor plan and 3D model generation in various applications such as navigation, interior design, furniture placement, facilities management, building construction, and HVAC design.

Sharma, Ritesh↗

Parametric optimization of PCM-enhanced underground thermal energy storage for buildings in moderate cold climates

This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short- and long-duration thermal energy storage technology, making it a promising technology for cold climates.

15 GEOTHERMAL ENERGY↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Opening the Door to Grid-Interactive Efficient Buildings with Energy Codes

Building codes represent standard design practice in the construction industry and must continually evolve to account for advancing technologies and innovative practices. Energy codes have historically focused on energy efficiency within buildings and across their systems. However, many of tomorrow's technologies go beyond efficiency and target increased flexibility. These demand flexibility (DF) measures can postpone or reduce building electric load based on price or other grid signals, and include smart appliances, connected lighting, and connected mechanical systems. Expanding codes to enable such grid-interactive efficient building (GEB) has the potential to influence their realization at scale, which will support renewable-energy grid-integration and building-sector decarbonization. However, considering DF measures in code development creates a new set of challenges for codes and the practices contained therein. This paper considers the role of building energy codes in enabling GEB. Specifically, it reviews the status of demand flexibility (DF) measures in current commercial building energy code. It examines the national model code development process and identifies components barring the consideration and inclusion of DF measures - including code scope, characterization and analysis of proposed new prescriptive measures, and accounting for time-of-day and geographic differences in their benefits. The paper presents findings from code development analyses that indicate the cost benefit of DF measures and the limitations associated with current code development conventions. To encourage building flexibility and improved energy resilience moving forward, recommendations are made for removing code development barriers and sanctioning DF measure consideration in future model codes.

Building Energy Codes and Standards, Grid-Interact↗

Protein Assembly by Design

Proteins are nature’s primary building blocks for the construction of sophisticated molecular machines and dynamic materials, ranging from protein complexes such as photosystem II and nitrogenase that drive biogeochemical cycles to cytoskeletal assemblies and muscle fibers for motion. Such natural systems have inspired extensive efforts in the rational design of artificial protein assemblies in the last two decades. As molecular building blocks, proteins are highly complex, in terms of both their three-dimensional structures and chemical compositions. To enable control over the self-assembly of such complex molecules, scientists have devised many creative strategies by combining tools and principles of experimental and computational biophysics, supramolecular chemistry, inorganic chemistry, materials science, and polymer chemistry, among others. Owing to these innovative strategies, what started as a purely structure-building exercise two decades ago has, in short order, led to artificial protein assemblies with unprecedented structures and functions and protein-based materials with unusual properties. Furthermore, our goal in this review is to give an overview of this exciting and highly interdisciplinary area of research, first outlining the design strategies and tools that have been devised for controlling protein self-assembly, then describing the diverse structures of artificial protein assemblies, and finally highlighting the emergent properties and functions of these assemblies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COVID-19 through Adverse Outcome Pathways: Building networks to better understand the disease – 3rd CIAO AOP Design Workshop

On April 28-29, 2021, 50 scientists from different fields of expertise met for the 3rd online CIAO workshop. The CIAO project “Modelling the Pathogenesis of COVID-19 using the Adverse Outcome Pathway (AOP) framework” aims at building a holistic assembly of the available scientific knowledge on COVID-19 using the AOP framework. An individual AOP depicts the disease progression from the initial contact with the SARS-CoV-2 virus through biological key events (KE) toward an adverse outcome such as respiratory distress, anosmia or multiorgan failure. Assembling the individual AOPs into a network highlights shared KEs as central biological nodes involved in multiple outcomes observed in COVID-19 patients. During the workshop, the KEs and AOPs established so far by the CIAO members were presented and posi­tioned on a timeline of the disease course. Modulating factors influencing the progression and severity of the disease were also addressed as well as factors beyond purely biological phenomena. CIAO relies on an interdisciplinary crowd­sourcing effort, therefore, approaches to expand the CIAO network by widening the crowd and reaching stakeholders were also discussed. To conclude the workshop, it was decided that the AOPs/KEs will be further consolidated, inte­grating virus variants and long COVID when relevant, while an outreach campaign will be launched to broaden the CIAO scientific crowd.

60 APPLIED LIFE SCIENCES↗

Simulation and power quality analysis of a Loose-Coupled bipolar DC microgrid in an office building

With distributed generation and battery storage technologies thriving in microgrids, the use of direct current (DC) microgrids in the building sector offers multiple advantages in energy efficiency and power quality compared with alternating current (AC) systems. This study developed a new concept of a loose-coupled bipolar DC building power system. In this work, the concept was used to design a real-world office building in Shenzhen, China. A power system model was developed to study the stability and control of the DC power system and to verify DC power quality. The design and modeling of the DC power control system is discussed in detail. The study developed a few common fault scenarios in DC building microgrids that were simulated in the MATLAB-Simulink environment to validate the design of a loose-coupled bipolar DC system. The results indicate that the proposed loose-coupled bipolar DC system schema, when implemented with proper control algorithms, can achieve good fault-tolerant performance with reliable power quality, even during disruptive system events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating AlphaFold and deep learning for atomistic interpretation of cryo-EM maps

Abstract Interpretation of cryo-electron microscopy (cryo-EM) maps requires building and fitting 3D atomic models of biological molecules. AlphaFold-predicted models generate initial 3D coordinates; however, model inaccuracy and conformational heterogeneity often necessitate labor-intensive manual model building and fitting into cryo-EM maps. In this work, we designed a protein model-building workflow, which combines a deep-learning cryo-EM map feature enhancement tool, CryoFEM (Cryo-EM Feature Enhancement Model) and AlphaFold. A benchmark test using 36 cryo-EM maps shows that CryoFEM achieves state-of-the-art performance in optimizing the Fourier Shell Correlations between the maps and the ground truth models. Furthermore, in a subset of 17 datasets where the initial AlphaFold predictions are less accurate, the workflow significantly improves their model accuracy. Our work demonstrates that the integration of modern deep learning image enhancement and AlphaFold may lead to automated model building and fitting for the atomistic interpretation of cryo-EM maps.

59 BASIC BIOLOGICAL SCIENCES↗

Advancements in Heat Transfer and Fluid Mechanics (Fundamentals and Applications)

Thermo-fluid science is a foundational discipline for numerous mechanical systems, particularly in energy production and building equipment, where thermal and mechanical energy transfer play critical roles. Advancements in heat transfer and fluid mechanics have significantly enhanced these systems, driving progress in associated market sectors. For instance, evaporator and condenser coils are essential for optimizing vapor compression cycles in building equipment. Heat pumps used for space and water heating constitute a major share of building systems, with microchannel heat exchanger technology at the forefront of these innovations. It is worth mentioning that advancements in heat transfer and fluid mechanics significantly alleviate the challenge of designing energy-efficient building equipment. The development of research techniques has contributed significantly to the advancement of science; for example, in the experimental field, non-intrusive measurement techniques such as Particle Image Velocimetry (PIV) are now capable of resolving flow behavior in a 3D format for different length and time scales.

42 ENGINEERING↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From Atoms to Wheels: The Role of Multi-Scale Modeling in the Future of Transportation Electrification

Traditionally, prototype hardware is built for validation testing to ensure battery systems design changes meet vehicle-level requirements, which is expensive both in cost and time. Virtual engineering (VE) of battery systems for electric vehicle (EV) propulsion offers a reduced-cost alternative to the traditional development process and uses multi-scale modeling to virtually probe the impact of design changes in a particular part on the overall performance of the system. This allows for rapid iteration over multiple design spaces, without committing to build hardware. This perspective article discusses current trends in VE for EV applications and proposes improvements to accelerate EV adoption.

Garrick, Taylor R. (ORCID:0000000322518129)↗

Field Measurement of Central CO2 Heat Pump Water Heater for Multifamily Retrofit

Domestic hot water heating of multifamily buildings accounts for a substantial portion of the energy load of existing buildings. This load is made up of both the energy required to produce hot water and the energy needed to maintain the temperature of the heated water within a building’s distribution piping so that heat can be promptly delivered to building occupants as needed. Properly designed heat pump water heater (HPWH) systems have the ability to improve efficiency in both water heating and temperature control operations. Further, CO2 heat pump technology reflects a shift away from traditional refrigerants and toward refrigerants with low global warming potential (GWP). In this paper’s case study, a design consisting of multiple CO2 heat pump water heaters (commonly used in single-family homes) with a novel “swing tank” was proposed to meet the demand for domestic hot water heating and recirculation loop temperature maintenance. The proposed design was applied to the retrofit of a 60-unit, low-rise, multi-family building located in the Pacific Northwest of the United States. The purpose of this paper is to verify the performance of the system including the proposed “swing tank” in a centralized SHW system using CO2 HPWH. It also provides practical information and lessons learned from the retrofit project. Long-term monitoring data showed that the system had a coefficient of performance (COP) of three or greater and provided an average of 20 gallons of hot water per day per apartment. The results of this work indicate that residential-scale CO2 HPWH equipment and a “swing tank” design can efficiently provide domestic hot water heating and temperature maintenance for mid-sized multifamily buildings.

Banks, Adria↗

Guide to Determining Climate Zone by County: Building America and IECC 2021 Updates

This report describes the climate zone designations used by the U.S. Department of Energy (DOE) Building America Program. The report aims to help residential building stakeholders identify the appropriate climate zone designation for each county in the United States, including Hawaii and Alaska. Identifying the correct climate zone is important for many activities including residential construction projects, code compliance, energy analysis and modeling, and other analytical activities where climate zones impact the energy and moisture performance of residential buildings. This report supersedes the previous Building America publication: Guide to Determining Climate Regions by County, published in 2010. This report reflects climate designations used by the International Code Council (ICC) in the 2021 versions of the International Energy Conservation Code (IECC), the International Residential Code (IRC), and other codes produced by ICC. The information provided here and associated data should be used for the most up-to-date information regarding climate zone designations in the United States.

2021 IECC↗

Accelerated Materials Design for Molten Salt Technologies Using Innovative High-Throughput Methods

The focus of the project is on building an innovative accelerated materials design platform for molten salt technologies using novel high-throughput methods coupled to data analytics. The main objectives is to predict a FeCrMnNi alloy compositional space with better corrosion resistance than stainless steel 316 and identify new molten salt corrosion mechanisms. The project demonstrates the feasibility to use high-throughput methods coupled to data analytics to accelerate alloy design for extreme environments applications. Using a trained and tested machine learning (ML) model, 2000 FeCrMnNi alloy corrosion rate in molten chloride salts were predicted and a compositional field with corrosion rate lower than 316 stainless steel was identified. The ML model interpretability unveiled multiple features of importance in the model prediction. Some features were expected to be of relative significance, such as work function, surface energy and alloy electronegativity, and the ML model interpretability analysis confirmed those. On the other hand, the most important feature is the diffusion coefficient of Ni in the bulk alloy which indicates that a surface diffusion mechanism plays an important role in the overall corrosion mechanism in molten salts.

36 MATERIALS SCIENCE↗