Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Effect of a growth hormone treatment on bone orthotropic elasticity in dwarf rats

A refinement of the current ultrasonic elasticity technique was used to measure the orthotropic elastic properties of rat cortical bone as well as to quantify changes in elastic properties, density, and porosity of the dwarf rat cortex after a treatment with recombinant human growth hormone (rhGH). The ultrasonic elasticity technique was refined via optimized signal management of high-frequency wave propagation through cubic cortical specimens. Twenty dwarf rats (37 days old) were randomly assigned to two groups (10 rats each). The dwarf rat model (5-10% of normal GH) was given subcutaneous injections of either rhGH or saline over a 14-day treatment period. Density was measured using Archimedes technique. Porosity and other microstructural characteristics were also explored via scanning electron microscopy and image analysis. Statistical tests verified significant decreases in cortical orthotropic Young's (-26.7%) and shear (-16.7%) moduli and density (-2.42%) concomitant with an increase in porosity (+125%) after rhGH treatments to the dwarf model (p < 0.05). A change in material symmetry from orthotropy toward planar isotropy within the radial-circumferential plane after GH treatments was also noted. These results demonstrate some alteration in bone properties at this time interval. Structural implications of these changes throughout physiological loading regimens should be explored.

NASA Discipline Musculoskeletal↗

Effects of spaceflight on rat peripheral blood leukocytes and bone marrow progenitor cells

The white blood cell (WBC) elements and the bone marrow myeloid progenitor cell populations were analyzed to ascertain adaptation to micro-gravity and subsequent readaptation to 1 G in rats flown on the 14-day Spacelab Life Sciences-2 (SLS-2) mission. Bone marrow cells were harvested from one group of rats killed inflight (FD13) and blood was drawn from three other groups at various times. The WBC level was normal on FD14 with the exception of neutrophilia. On FD13, numbers of colony-forming units-granulocyte (CFU-G), CFU-GM, and CFU-M from flight animals were decreased compared with ground controls when incubated with recombinant rat interleukin-3 (rrIL-3) alone or in combination with recombinant human erythropoietin (rhEpo). On recovery (R + 0), flight rats had decreased numbers of total leukocytes and absolute numbers of lymphocytes and monocytes with elevated neutrophils compared with control rats. They had lower numbers of CD4, CD8, CD2, CD3, and B cells in the peripheral blood but no differences in spleen lymphocytes.

NASA Discipline Number 00-00↗

Simulated Space Radiation and Weightlessness: Vascular-Bone Coupling Mechanisms to Preserve Skeletal Health

We examined experimentally the effects of radiation and/or simulated weightlessness by hindlimb unloading on bone and blood vessel function either after a short period or at a later time after transient exposures in adult male, C57Bl6J mice. In sum, recent findings from our studies show that in the short term, ionizing radiation and simulate weightlessness cause greater deficits in blood vessels when combined compared to either challenge alone. In the long term, heavy ion radiation, but not unloading, can lead to persistent, adverse consequences for bone and vessel function, possibly due to oxidative stress-related pathways.

microgravity↗

Cost and Time Effective Lithography of Reusable Millimeter Size Bone Tissue Replicas With Sub‐15 nm Feature Size on A Biocompatible Polymer

Abstract The ability to replicate the microenvironment of biological tissues creates unique biomedical possibilities for stem cell applications. Current fabrication methods are limited by either the control on feature size and shape, or by the throughput and size of the replicas. Here, a novel platform is reported that combines thermal scanning probe lithography (tSPL) with innovative methodologies for the low‐cost and high‐throughput nanofabrication of large area quasi‐3D bone tissue replicas with high fidelity, sub‐15 nm lateral precision, and sub‐2 nm vertical resolution. This bio‐tSPL platform features a biocompatible polymer resist that withstands multiple cell culture cycles, allowing the reuse of the replicas, further decreasing costs and fabrication times. The as‐fabricated replicas support the culture and proliferation of human induced mesenchymal stem cells, which display broad therapeutic and biomedical potential. Furthermore, it is demonstrated that bio‐tSPL can be used to nanopattern the bone tissue replicas with amine groups, for subsequent tissue‐mimetic biofunctionalization. The achieved level of time and cost‐effectiveness, as well as the cell compatibility of the replicas, make bio‐tSPL a promising platform for the production of tissue‐mimetic replicas to study stem cell‐tissue microenvironment interactions, test drugs, and ultimately harness the regenerative capacity of stem cells and tissues for biomedical applications.

Liu, Xiangyu↗

Trends in Radiation Therapy for Bone Metastases, 2015 to 2017: Choosing Wisely in the Era of Complex Radiation

Guidelines recommend short-course (≤10 fractions) external-beam radiation therapy (EBRT) for bone metastases. Stereotactic body radiation therapy (SBRT) may also improve outcomes; however, routine use is not recommended outside clinical trials. We assessed national radiation therapy trends in complex techniques for bone metastases and associated expenditures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasmonic Hybridization and Near-Field Localization in Gold “Dog Bone” Nanoparticles

Gold nanoparticles with complex anisotropic geometries offer unique opportunities for tailoring plasmonic near-fields beyond the limits of conventional nanorods. Here we combine photon-induced near-field electron microscopy (PINEM) and full-wave simulations to resolve plasmon hybridization and near-field localization in gold dog-bone nanoparticles and their dimers with and without conformal SiO 2 shells. We demonstrate that the dog-bone geometry drives unconventional polarization-dependent field confinement, including pronounced tip-localized near-fields under both longitudinal and transverse excitation. Conformal SiO 2 shells red-shift the plasmon resonances through dielectric screening and prevent charge-transfer coupling in adjacent dimers. Depending on the dimer orientation and excitation polarization, coupled structures exhibit distinct bonding- and antibonding-like hybridized modes as well as interparticle near-field channels. However, weakly interacting dimers retain largely independent particle responses with geometry-governed asymmetries. The close agreement between PINEM measurements and simulations establishes a direct picture of how shape, dielectric environment, and nanoscale coupling together define plasmonic modes in complex anisotropic nanoparticles. These findings provide design principles for engineering localized optical fields in plasmonic nanoscale structures.

hybridization↗

Motion of Molecules in Supramolecular Scaffolds Enhances Bone Regeneration

The regeneration of human tissues is a great scientific challenge and a critical factor to achieve a long healthspan and prevent disabilities due to injury or disease. Materials chemistry can contribute to this goal with the development of bioactive supramolecular systems that can signal cells for regeneration. Recent work in our laboratory using in vivo models of spinal cord injury and cartilage regeneration has demonstrated that the motion of bioactive molecules in supramolecular scaffolds enhances receptor signaling. We report here on a novel molecular strategy to control supramolecular motion in filamentous assemblies using bone regeneration as a functional target. The supramolecular assemblies are composed of monomers that arrange, by design, with either parallel or antiparallel β-sheets, and some of them contain a terminal peptide sequence that binds BMP-2. We found that parallel β-sheet supramolecular assemblies promote greater osteogenic differentiation of progenitor cells in vitro relative to antiparallel assemblies, as well as superior quality of newly regenerated bone in a rat model of spinal fusion. Furthermore, these assemblies drastically reduce the dangerous supraphysiological dose of BMP-2 used clinically for spinal fusion. Here, we attribute the enhanced bioactivity to the weaker nature of hydrogen bonds in parallel relative to antiparallel β-sheet assemblies, which in turn allows greater supramolecular motion and cell signaling of the growth factor-binding molecules.

Anatomy↗

Bi-fated tendon-to-bone attachment cells are regulated by shared enhancers and KLF transcription factors

The mechanical challenge of attaching elastic tendons to stiff bones is solved by the formation of a unique transitional tissue. Here, we show that murine tendon-to-bone attachment cells are bi-fated, activating a mixture of chondrocyte and tenocyte transcriptomes, under regulation of shared regulatory elements and Krüppel-like factors (KLFs) transcription factors. High-throughput bulk and single-cell RNA sequencing of humeral attachment cells revealed expression of hundreds of chondrogenic and tenogenic genes, which was validated by in situ hybridization and single-molecule ISH. ATAC sequencing showed that attachment cells share accessible intergenic chromatin areas with either tenocytes or chondrocytes. Epigenomic analysis revealed enhancer signatures for most of these regions. Transgenic mouse enhancer reporter assays verified the shared activity of some of these enhancers. Finally, integrative chromatin and motif analyses and transcriptomic data implicated KLFs as regulators of attachment cells. Indeed, blocking expression of both Klf2 and Klf4 in developing limb mesenchyme impaired their differentiation.

59 BASIC BIOLOGICAL SCIENCES↗

Mineral intake and bone loss.

Nutrition role in bone formation and maintenance noting Ca metabolism, intake and balance, bone loss and disease and P, Mg and fluorides

Hegsted, D. M.↗

Cutting thin sections of bone

Medical equipment for obtaining repetitive planoparallel sections of bone to study healing of bone structure under high gravity stress is described. Device consists of modified saw with diamond cutting edges. Construction of device and manner of use are explained.

Ashley, W. W.↗

Ultrasonic bone densitometer

Human bone density changes can be determined by a device originally developed for in-flight testing of astronauts' bones during extended space missions. Device is comparable in size, weight and power consumption to portable television set.

Hoop, J. M.↗

Comparison of calcium and phosphorus excretion with bone density changes during restraint in immature Macaca nemestrina primates.

Calcium and phosphorus balance data on Macaca nemestrina monkeys during immobilization are presented and correlated with X-ray bone densitometry findings. A positive mineral balance was maintained during the immobilized period. A reduced bone density was observed in most skeletal sites examined with increased density observed in epiphyseal regions. Migration of mineral from one site to another is suggested as a possible explanation for the findings.

Hoffman, R. A.↗

In vivo measurement of mechanical impedance of bone

System of measurement provides indications of ulnar properties independent of characteristics of surrounding soft tissue and other bones. Mechanical modal approximated ulnar response so average bending rigidity could be determined to provide direct index of bone resistance to bending loading.

Young, D. R.↗

Bone mineral changes in the Apollo astronauts

Loss of mineral from bone during periods of immobilization, recumbency or weightlessness have been observed. These losses are more apparent in the lower extremity than the upper and have been observed to exceed 30% in the case of the central os calcis during 36 weeks of bedrest. In early Gemini studies using X-ray densitometry, large losses of bone mineral were observed in the radius and ulna. This observation was not validated in the Apollo 14, 15 and 16 crewmen when a more precise technique, gamma ray absorptiometry, was used. The large losses reported for the early Gemini missions were not seen when this new measuring technique was employed.

Vogel, J. M.↗

Bone mineral measurement - Skylab experiment M-078

Experimental observations of loss of bone mineral due to prolonged bedrest or weightlessness are reported. A new, precise method was employed that featured an essentially monoergetic photon source (125I) and a scintillation detector operating in a rectilinear scanning mode to measure bone mineral in the radius, ulna, and os calcis by the absorptiometric technique. Variable but small losses were found during 4-6 weeks of bedrest; losses of up to 40% were noted in the os calcis after 9 months. When the technique was used during the Apollo 14, 15, and 16 missions, only one crewmen showed significant losses in the os calcis and none in the radius or ulna. The variability recorded during bedrest was connected with the initial 24-hr urinary hydroxyproline excretion and the initial os calcis mineral content. The relevance of prediction terms based on bedrest data to Skylab and longer missions is discussed.

Vogel, J. M.↗