Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Diagnostics for measuring 4D beam matrix [Slides]

Detailed knowledge on the particle distribution in accelerators can strongly benefit machine tuning and understanding of deleterious effects, which degrade beam quality. Properties of the beam downstream the beamline (i.e. 4D beam matrix) depend on beam properties upstream and parameters of the beamline. Measuring 2D x-y beam profile downstream provides limited information about the beam. Multiple measurements at different settings of the beamline (quadrupole scan) may provide enough information to recover original beam profile. Essentially, this concept is similar to tomography, when we need to reconstruct a higher dimension object from multiple low dimension projections.

43 PARTICLE ACCELERATORS↗

Impulsive H-alpha diagnostics of electron-beam-heated solar flare model chromospheres

Time-dependent H-alpha profiles were computed for the dynamic model atmospheres of Fisher, Canfield, and McClymont (1985) simulating the effects of an intense impulsively initiated power-law beam of electrons incident on the chromosphere. The temporal response of H-alpha arises from three separate physical mechanisms, whose relative importance varies over the line profile. The fastest variations (typically less than 0.1 s for the explosive heating discussed here) arise from energy imbalance; these are apparent on chromospheric heating and cooling time scales and have their greatest amplitude at line center. Slower variations arise from ionization imbalance and are most apparent in the blue wing. The slowest variations arise from hydrodynamic effects and are related to the formation of a chromospheric condensation; these are most apparent in the red wing. These results provide a basis for the design and analysis of observations of H-alpha, in coordination with hard X-rays or microwaves, to test mechanisms of energy transport in solar flares.

Canfield, Richard C.↗

Characterization of high-current electron beam interaction with metal targets

The process of electron beam interaction with metal targets was characterized using electrical and optical diagnostics. Electron beams with current density of 5-10 A/cm{sup 2}, electron energy up to 120 keV, pulse duration up to 200 {mu}s, and cross-sectional area of 8-30 cm{sup 2} at the target surface were generated by GESA I and GESA II facilities. Streak imaging of the target surface specular reflectivity was used to determine the onset of melting and re-solidification of the target surface. Using time- and space-resolved schlieren imaging, the evolution of surface irregularities was studied. Experimental and numerical investigations of the neutral flow evaporated from the target surface showed a neutral density of {approx}10{sup 19} cm{sup -3} in the vicinity of the target and neutral velocities up to 2 x 10{sup 5} cm/s. Framing and streak images of visible light emission were used to study the temporal evolution of the target surface plasma and vapors. Time- and space-resolved spectroscopy was applied to determine the surface plasma density and temperature, which were found to be {approx}10{sup 14} cm{sup -3} and {<=}1 eV, respectively. Because of this small plasma density, electric fields in the plasma sheath are not sufficient to cause electrohydrodynamic instability of the liquid target surface. However, hydrodynamic instabilities due to the intense neutral flow observed in experimental and numerical studies are likely to be responsible for the growth of wavelike irregularities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined hydrogen and lithium beam emission spectroscopy observation system for Korea Superconducting Tokamak Advanced Research

A novel beam emission spectroscopy observation system was designed, built, and installed onto the Korea Superconducting Tokamak Advanced Research tokamak. The system is designed in a way to be capable of measuring beam emission either from a heating deuterium or from a diagnostic lithium beam. The two beams have somewhat complementary capabilities: edge density profile and turbulence measurement with the lithium beam and two dimensional turbulence measurement with the heating beam. Two detectors can be used in parallel: a CMOS camera provides overview of the scene and lithium beam light intensity distribution at maximum few hundred Hz frame rate, while a 4 × 16 pixel avalanche photo-diode (APD) camera gives 500 kHz bandwidth data from a 4 cm × 16 cm region. The optics use direct imaging through lenses and mirrors from the observation window to the detectors, thus avoid the use of costly and inflexible fiber guides. Remotely controlled mechanisms allow adjustment of the APD camera’s measurement location on a shot-to-shot basis, while temperature stabilized filter holders provide selection of either the Doppler shifted deuterium alpha or lithium resonance line. The capabilities of the system are illustrated by measurements of basic plasma turbulence properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade

Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (<10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from a diamond placed edge-on to the x-ray beam. Because of the high peak power density of the x-ray beams, this diamond experiences high temperatures and has to be clamped to a water-cooled heat spreader using thermal interface materials (TIMs), which play a key role in reducing the temperature of the diamond. To evaluate temperature changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This study presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.

43 PARTICLE ACCELERATORS↗

Fast switching magnet for heavy ion beam separation

This paper presents the design for a switching magnet capable of deflecting 6.5 MeV/u heavy-ion beams with mass-to-charge ratio of 7 by 10 degrees. This magnet can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The magnet has a laminated, iron dominated, H-shaped core. Directly-cooled copper pancake coils energize the magnet. We present the magnet design considerations, including the results of extensive computer modeling. Finally, we also present the conceptual engineering design and the studies of magnet yoke fabrication.

47 OTHER INSTRUMENTATION↗

Near-infrared noise in intense electron bunches

This article investigates electron bunch density fluctuations in the 1 −10 μ⁢m wavelength range, focusing on their impact on coherent electron cooling (CEC) in hadron storage rings. In this study, we compare the shot-noise model with experimental observations using bandwidth-filtered near-infrared optical transition radiation (OTR) photodiode signals, where the transverse bunch size is much larger than the OTR wavelength of interest. The relativistic electron bunch (𝛾 ≈ 50) parameters are close to those proposed for the coherent electron cooler in the electron-ion collider (EIC) project. Preliminary feasibility experiments were conducted, and the noise factors are presented, supported by particle tracking. No major density fluctuations or effective cooling rate decrease were revealed for EIC CEC design parameters. Additionally, longitudinal-space-charge-induced microbunching for the chicane-compressed bunch was observed with coherent OTR enhancements up to 100 times, providing further calibration of the measurement method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge-exchange recombination spectroscopy of the plasma ion temperature at the T-10 tokamak

Charge-exchange recombination spectroscopy (CXRS) based on a diagnostic neutral beam has been developed at the T-10 tokamak. The diagnostics allows one to measure the ion temperature profile in the cross section of the plasma column. In T-10 experiments, the measurement technique was adjusted and the elements of the CXRS diagnostics for ITER were tested. The used spectroscopic equipment makes it possible to reliably determine the ion temperature from the Doppler broadening of impurity lines (helium, carbon), as well as of the spectral lines of the working gas. The profiles of the plasma ion temperature in deuterium and helium discharges were measured at different plasma currents and densities, including with the use of active Doppler measurements of lines of different elements. The validity and reliability of ion temperature measurements performed by means of the developed CXRS diagnostics are analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Castellated tiles as the beam-facing components for the diagnostic calorimeter of the negative ion source SPIDER

This paper presents the results of numerical simulations and experimental tests carried out to assess the feasibility and suitability of graphite castellated tiles as beam-facing component in the diagnostic calorimeter of the negative ion source SPIDER (Source for Production of Ions of Deuterium Extracted from Radio frequency plasma). The results indicate that this concept could be a reliable, although less performing, alternative for the present design based on carbon fiber composite tiles, as it provides thermal measurements on the required spatial scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase Space Reconstruction from Accelerator Beam Measurements Using Neural Networks and Differentiable Simulations

Characterizing the phase space distribution of particle beams in accelerators is a central part of accelerator understanding and performance optimization. However, conventional reconstruction-based techniques either use simplifying assumptions or require specialized diagnostics to infer high-dimensional (> $2D$) beam properties. In this Letter, we introduce a general-purpose algorithm that combines neural networks with differentiable particle tracking to efficiently reconstruct high-dimensional phase space distributions without using specialized beam diagnostics or beam manipulations. Furthermore, we demonstrate that our algorithm accurately reconstructs detailed 4D phase space distributions with corresponding confidence intervals in both simulation and experiment using a single focusing quadrupole and diagnostic screen. This technique allows for the measurement of multiple correlated phase spaces simultaneously, which will enable simplified 6D phase space distribution reconstructions in the future.

47 OTHER INSTRUMENTATION↗

The Characterization and Performance of the Luminosity Monitors for the Qweak Experiment at Jefferson Lab

The $Q_{weak}$ experiment at Jefferson Lab is a precision measurement of the weak charge of the proton using parity-violating electron scattering. To make this measurement the experiment uses diagnostic detectors with small counting statistical errors that provide information about beam and target properties. The $Q_{weak}$ luminosity monitors were designed to provide this information. The luminosity monitors are arrays of quartz \v Cerenkov detectors coupled with air lightguides to photomultiplier tubes operating in unity gain mode and read out in current mode. There are two sets of luminosity monitors, a ``downstream'' array at a mean laboratory scattering angle of 0.5 degrees that detects an equal mixture of elastic e-p and M\o ller scattered electrons and an ``upstream'' array at a mean scattering angle of 5 degrees that primarily detects low energy M\o ller scattered electrons. The monitors can also be equipped with high gain bases to operate in pulse counting mode for use as beam monitors in special low beam current diagnostic runs. The characterization and performance of the luminosity monitors will be presented.

Leacock, John↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Diagnostics for ITER

After an introduction into the specific challenges in the field of diagnostics for ITER (specifically high level of nuclear radiation, long pulses, high fluxes of particles to plasma facing components, need for reliability and robustness), an overview will be given of the spectroscopic diagnostics foreseen for ITER. The paper will describe both active neutral-beam based diagnostics as well as passive spectroscopic diagnostics operating in the visible, ultra-violet and x-ray spectral regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status and Plans for an SRF Accelerator Test Facility at Fermilab

A superconducting RF accelerator test facility is currently under construction at Fermilab. The accelerator will consist of an electron gun, 40 MeV injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, and multiple downstream beam lines for testing diagnostics and performing beam experiments. With 3 cryomodules installed this facility will initially be capable of generating an 810 MeV electron beam with ILC beam intensity. The facility can accommodate up to 6 cryomodules for a total beam energy of 1.5 GeV. This facility will be used to test SRF cryomodules under high intensity beam conditions, RF power equipment, instrumentation, and LLRF and controls systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

43 PARTICLE ACCELERATORS↗