Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Mo-99 Concentration and processing by Solvent Extraction and Ion Exchange

Normally derived from its transient-equilibrium parent molybdenum-99 ( 99 Mo) (t½ = 66 h), the short-lived isotope technetium-99m ( 99m Tc) (t ½ = 6.0 h) is the most widely used medical isotope in diagnostic imaging today. The National Nuclear Security Administration’s (NNSA’s) Material Management and Minimization (M3) program—established under the auspices of the American Medical Isotope Production Act—has been tasked with facilitating the work of domestic 99 Mo suppliers that do not use highly enriched uranium (HEU). Superconducting electron linear accelerators that employ high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that can induce photonuclear reactions and uranium (U) fission. Argonne, in collaboration with industrial partners, has been developing the process chemistry for superconducting linear accelerator (LINAC)-irradiated triuranium octoxide (U 3 O 8 ) targets to produce 99 Mo. In short, the process involves dissolving the irradiated targets in nitric acid, which simultaneously releases valuable fission products (xenon and iodine). After adjusting the acid concentration, producers process the feed using tri-n-butyl phosphate (TBP), then mix the raffinate derived from this extraction cycle with a phosphinic acid such as Cyanex 272 or di(2-ethylhexyl) phosphoric acid (HDEHP), which is selective for Mo (molybdenum liquid liquid extraction [MoLLE]). In the next step, a concentration column comprising an anion exchange platform is used to decontaminate the remaining fission products, generating a pure 99 Mo stream in sodium hydroxide (NaOH)/sodium chloride (NaCl).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of the Energy Spread for CeC Project

The Coherent Electron Cooling requires small energy spread and uniformity of energy along the bunch. The diagnostics line is utilized for the measurement of the electron beam parameters. The beamline layout is shown in Fig. 1. Three quadrupoles after the linac are used to match beam into the common section. The main dipole is used to deflect beam towards common section. If it is switched off the beam goes to the diagnostics line. The beam optics in the diagnostics line is controlled by four quadrupoles. The deflecting cavity sweeping beam in the vertical direction follows the quadrupoles. Sector dipole is used for energy parameters measurement. It has deflection angle of 30 degrees. With diagnostics dipole switched off the beam propagated to the insertable slits system for emittance measurement. There are four profile monitors in the line, The first profile monitor (ACC YAG) is after the main dipole. The second profile monitor (YAG3) is in front of the diagnostics dipole after the deflecting cavity. YAG1 profile monitor is placed after the slits, and YAG2 profile monitor is placed after the diagnostics dipole. There is a solenoid between the deflecting cavity and YAG3. It is used for the beam energy measurement.

43 PARTICLE ACCELERATORS↗

Cosmic-ray gradients in the outer heliosphere

We report on a study of the expected spatial variation of the galactic cosmic-ray intensity in the vicinity of the solar-wind termination shock. Model simulations predict that the radial gradients change abruptly at the shock, and that the nature of the effect varies significantly with particle energy. At low energies, the radial gradient changes abruptly from a lower value inside the shock to a higher value outside, whereas at high energies, the higher value of the gradient is inside the shock. This effect, which is a consequence of the matching conditions at the shock and is closely related to diffusive shock acceleration, is qualitatively the same for both heliospheric magnetic polarity states and remains much the same in one-dimensional, two-dimensional and three-dimensional models. Hence drifts do not change the nature of this phenomenon, although they change it quantitatively. The effect may prove to be an important diagnostic tool for the study of the termination of the solar wind.

Kota, J.↗

New Laboratory-Based Satellite Impact Experiments for Breakup Fragment Characterization

A consortium consisting of the NASA Orbital Debris Program Office, U.S. Air Force's Space and Missile Systems Center, the Aerospace Corporation, and University of Florida is planning a series of hypervelocity impact experiments on mockup targets at the U.S. Air Force's Arnold Engineering Development Complex (AEDC) in early 2014. The target for the first experiment resembles a rocket upper stage whereas the target for the second experiment represents a typical 60‐cm/50‐kg class payload that incorporates modern spacecraft materials and components as well as exterior wrap of multi‐layer insulation and three solar panels. The projectile is designed with the maximum mass that AEDC's Range G two‐stage light gas gun can accelerate to an impact speed of 7 km/sec. The impact energy is expected to be close to 15 MJ to ensure catastrophic destruction of the target after the impact. Low density foam panels are installed inside the target chamber to slow down and soft‐catch the fragments for post‐impact processing. Diagnostic instruments, such as x‐ray and high speed optical cameras, will also be used to record the breakup process. The main goal of this "DebriSat" project is to characterize the physical properties, including size, mass, shape, and density distributions, of orbital debris that would be generated by a hypervelocity collision involving an upper stage or a modern satellite in the low Earth orbit environment. In addition, representative fragments will be selected for laboratory optical and radar measurements to allow for better interpretation of data obtained by telescope and radar observations. This paper will provide a preliminary report of the impact results and the plans to process, measure, and analyze the fragments.

Liou, J.-C.↗

A smart alarm for particle accelerator beamline operations

We present the initial results of a proof-of-concept 'smart alarm' for the Continuous Electron Beam Accelerator Facility injector beamline at Jefferson Lab. To minimize machine downtime and improve operational efficiency, an autonomous alarm system able to identify and diagnose unusual machine states is needed. Our approach leverages a trained neural network capable of alerting operators (a) when an anomalous condition exists in the beamline and (b) identifying the element setting that is the root cause. The tool is based on an inverse model that maps beamline readings (diagnostic readbacks) to settings (beamline attributes operators can modify). The model takes as input readings from the machine and computes machine settings which are compared to control setpoints. Instances where predictions differ from setpoints by a user-defined threshold are flagged as anomalous. Given data corresponding to 354 anomalous injector configurations, the model can narrow the root cause of an anomalous condition to three potential candidates with 94.6% accuracy. Furthermore, compared to the current method of identifying anomalous conditions which raises an alarm when machine parameters drift outside their normal tolerances, the data-driven model can identify 83% more anomalous conditions.

43 PARTICLE ACCELERATORS↗

Solar wind and coronal structure

Spectroscopic diagnostic techniques used to determine the coronal source region of the solar wind, and results of preliminary applications are examined. The topics reviewed are magnetic fields, coronal mass ejections, coronal holes, flow velocities, coronal temperatures, fine spatial structure, and future observational programs. The physical mechanisms responsible for plasma heating, solar-wind acceleration, the transport of mass momentum and energy, and the spatial differentiation of chemical abundances are also discussed. Among the data presented are Skylab's white-light coronagraph photograph of a coronal transient, X-ray photographs of the corona, and spectroheliograms showing bright points overlying polar plumes, and macrospicules.

Withbroe, G. L.↗

What We Learned From Analyzing 18 Million Rows of Commercial Buildings’ HVAC Fault Data

To achieve ambitious decarbonization goals it is critical that buildings operate to their full potential. Commercial HVAC systems, however, experience a wide range of operational faults, adversely affecting energy consumption, occupant comfort, and maintenance costs. Analytical tools such as fault detection & diagnostics (FDD) software identify and help diagnose these types of sensing, mechanical, or control-related faults. While significant energy savings has been documented for FDD, along with limited-scale studies on technical capabilities, there is a lack of empirical data on faults being reported by FDD tools. With FDD deployment accelerating significantly over the past decade there is an opportunity to gather and analyze data on commercial HVAC operational problems at an unprecedented scale. Such data could address many questions such as: [a] What faults are most commonly reported?; and [b] How does fault reporting vary by time of year and other possible drivers? A recent study into FDD fault reporting amassed the largest U.S. dataset of commercial HVAC air-side fault records, drawn from multi-year monitoring across over 60,000 pieces of HVAC equipment. The results of this study provide granular data on fault reporting for over 90 unique fault types. In this paper we provide an overview of the research process and highlight key findings and lessons learned. This study presents an extraordinary level of detail on FDD fault reporting characteristics across many climate zones and building types. Armed with these new insights, commercial building industry stakeholders can make better informed decisions when designing, configuring, and operating commercial HVAC systems.

Crowe, Eliot↗

Diagnosing nuclear power plant pipe wall thinning due to flow accelerated corrosion using a passive, thermal non-destructive evaluation method: Feasibility assessment via numerical experiments

Flow accelerated corrosion (FAC) in nuclear power plant pipes is one of the leading causes of accidents, fatalities, damage and outages. Current FAC identification methods employ expensive sensing technology and are “active” methods, where the response of the piping system to an externally-generated thermal, mechanical or optical excitation must be measured. As a result, these techniques require a disruptive and time-consuming setup. Here we propose a method that utilizes pipe surface temperature measurements to passively monitor for FAC-induced pipe wall thinning without the need for expensive equipment or post-installation setup time. This diagnostic method utilizes a simulation data-driven diagnostic model to estimate the amount of thickness reduction in a pipe based on changes in measured steady-state pipe temperatures. In order to reduce the computational burden of generating large, simulation-based datasets, the behavior of the insulation of the pipe was modeled using a suitably calibrated heat transfer boundary parameter. Additionally, global sensitivity analysis was performed to determine system parameter(s), such as the temperature of water flowing inside the pipe, which significantly affect the steady state pipe wall temperature and could cause errors in diagnosis. Two diagnostic models, one using only the change in steady-state temperature as an indicator for FAC-induced pipe wall thinning and the other using water temperature as an additional diagnostic model input were evaluated for their ability to estimate thickness reductions in a pipe using simulated pipe wall temperature data. For the numerical experiments conducted in this work, both models estimated wall thickness with errors within 0.5 mm, indicating that the proposed technique can potentially be used as a low-cost, first-pass method for FAC monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

KBKit: A Python Toolkit for Kirkwood–Buff Theory from Molecular Dynamics

Thermodynamic properties of liquid mixtures govern processes that range from drug delivery to energy storage, yet extracting these properties from molecular simulations remains challenging. Kirkwood–Buff (KB) theory offers a rigorous route by linking microscopic pair distribution functions to macroscopic free energies, but practical use of the theory has been hindered by two obstacles: (i) the long simulations needed to obtain well-converged Kirkwood-Buff integrals (KBIs) and (ii) the specialized corrections required to translate finite-size data to the thermodynamic limit. $\texttt{KBKit}$ is an open-source Python package that removes these barriers. It automatically computes KBIs and derived thermodynamic quantities from GROMACS input files, applies state-of-the-art finite-size corrections, and provides built-in diagnostic tools to quantify statistical uncertainty. Written with modern software-engineering practices—continuous integration, extensive unit testing, and thorough documentation—$\texttt{KBKit}$ is both reliable and easy to extend. By condensing complex KBI analysis into a few intuitive commands, $\texttt{KBKit}$ enables researchers to incorporate KB theory into routine simulation workflows and accelerate the discovery of solution-phase thermodynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Versatile multi-energy hard x-ray camera to study confined and unconfined fast electron dynamics and anisotropies (Invited)

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at the pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space, energy, and time resolved x-ray measurements. The novel camera has been used to measure the core radiation from non-Maxwellian (fast) electrons accelerated by Lower Hybrid (LH) waves and also the beam–target emission of tungsten in the divertor region produced by fast electron losses interacting with the target. In addition, anisotropic hard x-ray emission has been detected for the first time at the WEST core and edge plasma, with opposite toroidal intensity trends. Finally, experimental vertical and toroidal HXR profiles have been successfully reproduced with the LH code LUKE.

47 OTHER INSTRUMENTATION↗

Status of Error Correction Studies in Support of FFA@CEBAF

In pursuit of higher energy at the Continuous Electron Beam Accelerator Facility (CEBAF), the FFA@CEBAF energy upgrade study is considering the implementation of a novel technology to recirculate electron beam through the accelerating gradient of the machine more times. The technology in question is Fixed-Field Alternating-gradient (FFA) bending accelerator arcs: these arcs may replace the present highest energy electromagnetic (EM) arcs, and due to a much wider energy acceptance allow several more passes. The survey and beam error tolerance of the FFA arcs need to be well understood prior to commissioning, in addition to the limits of planned correction magnets and diagnostics. This work explores the current state of error tolerance and correction studies in FFA arcs at CEBAF.

Benesch, J.↗

The Crimean Solar Maximum Year Workshop, selected reports

Problems associated with the transport of energy and acceleration of charged particles in solar flares are considered. Existing theories are compared with observation with a view to either discriminating between rival theories (such as whether hard X-rays are emitted by thermal or nonthermal bremsstrahlung), constraining existing theories (such as deduction of the number of nonthermal electrons present from spectroscopic diagnostics in the soft X-ray part of the spectrum), or suggesting theories (such as attempting to explain the observed spatial structure of microwave emission relative to alpha).

Emslie, A. G.↗

Post-DTL Beam Delivery

Ensuring that the beam delivered from the upgraded Front-End (FE) meets the Key Performance Parameters (KPPs) at each user facility is critical to the success of the LANSCE Accelerator Modernization Project (LAMP). For a high-intensity, multi-user facility like LANSCE, compliance with beam loss and radiation thresholds is as important as the charge delivered to each target. While early LAMPF/LANSCE operations relied on iterative tuning to minimize losses from beam halo and tail particles, the new FE may introduce different beam distributions and loss modes—making predictive modeling essential. To manage this, the F2E (Front-End to End) effort is developing detailed particle-tracking models that reflect realistic beamline conditions, including halo formation and expected diagnostic readings. These "snapshot" simulations aim to benchmark live machine performance at a given moment. This will help quantify how beam quality from the new FE will propagate downstream through the facility. Only by validating these models can we confidently assess and mitigate the potential impacts of the LAMP FE on beam delivery. Post-DTL, the beam splits to serve five major user facilities. Historically, low-energy beam transport has been modeled using TRACE, and higher-energy sections with TRANSPORT. These have now been unified into MAD-X format and validated with codes such as Elegant, pyOrbit, XSuite, Impact-Z, and HPSim. The primary focus now is on accurate modeling of full particle distributions (including beam halo) as they traverse the accelerator and beamlines to each experimental station. All models are at various stages of validation with empirical data.

43 PARTICLE ACCELERATORS↗

Precision beam diagnostics at the NuMI facility using muon monitor observations

The Neutrinos at the Main Injector (NuMI) facility at Fermilab delivers an intense neutrino beam for multiple experiments by producing pions that decay into neutrinos, muons, and other particles. Magnetic horns—the primary pion focusing elements in the NuMI beamline—exhibit predominantly linear optics, enabling a predictable relationship between the proton beam and the resulting pion and muon phase spaces. This study has two primary objectives: first, to evaluate and confirm the linearity of the horn focusing mechanism using analytical models and numerical simulations; and second, to demonstrate that key beam parameters—such as proton beam intensity, beam position on target, and horn current—can be extracted from muon monitor observations within this linear optics framework. Using a machine learning model trained on spill-by-spill muon monitor data, we infer the horn current with a precision of ±0.05%, the beam intensity with ±0.1%, and the beam position on target with ±0.018⁢ mm horizontally and ±0.013⁢ mm vertically. This approach provides a reliable cross-check of beam parameters, helping to reduce systematic uncertainties that are critical for future experiments such as the Deep Underground Neutrino Experiment, which will rely on the neutrino beam produced by the Long-Baseline Neutrino Facility.

Beam control↗

Deep learning with plasma plume image sequences for anomaly detection and prediction of growth kinetics during pulsed laser deposition

Abstract Materials synthesis platforms that are designed for autonomous experimentation are capable of collecting multimodal diagnostic data that can be utilized for feedback to optimize material properties. Pulsed laser deposition (PLD) is emerging as a viable autonomous synthesis tool, and so the need arises to develop machine learning (ML) techniques that are capable of extracting information from in situ diagnostics. Here, we demonstrate that intensified-CCD image sequences of the plasma plume generated during PLD can be used for anomaly detection and the prediction of thin film growth kinetics. We develop multi-output (2 + 1)D convolutional neural network regression models that extract deep features from plume dynamics that not only correlate with the measured chamber pressure and incident laser energy, but more importantly, predict parameters of an auto-catalytic film growth model derived from in situ laser reflectivity experiments. Our results demonstrate how ML with in situ plume diagnostics data in PLD can be utilized to maintain deposition conditions in an optimal regime. Further, the predictive capabilities of plume dynamics on the kinetics of film growth or other film properties prior to deposition provides a means for rapid pre-screening of growth conditions for the non-expert, which promises to accelerate materials optimization with PLD.

36 MATERIALS SCIENCE↗

Evidence for electron energization accompanying spontaneous formation of ion acceleration regions in expanding plasmas

We report experiments conducted in an expanding argon plasma generated in the inductive mode of a helicon source in the Hot hELIcon eXperiment–Large Experiment on Instabilities and Anisotropies facility. As the neutral gas pressure increases, the supersonic ion acceleration weakens. Increasing neutral pressure also alters the radial profile of electron temperature, density, and plasma potential upstream of the plasma expansion region. Langmuir probe measurements of the electron energy probability function (EEPF) show that heating of electrons at the plasma edge by RF fields diminishes with increasing gas pressure, yielding a plasma with a centrally peaked electron temperature, and flat potential profiles at higher neutral pressures. For neutral pressures at which ion acceleration regions develop in the expanding plasma plume, EEPFs reveal electrons with two temperature components.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing the Mechanical Response of the Saturn Accelerator

The Saturn Particle Accelerator is a hot X-ray source used by the NNSA for creating conditions similar to that of a nuclear weapon. When Saturn fires some of it's energy is released in the form of mechanical shock and vibration. This mechanical output has not been characterized or understood, making design of components and diagnostics more difficult. Thus it will be helpful to understand this mechanical shock. This poster presents the beginnings of a project to do just that.

Cuneo, Nicolas Francis [Sandia National Laboratori↗

Active region flows

A wide range of observations has shown that active region phenomena in the photospheric, chromospheric and coronal temperature regimes are dynamical in nature. At the photosphere, recent observations of full line profiles place an upper limit of about + or - 20/msec on any downflows at supergranule cell edges. Observations of the full Stokes 5 profiles in the network show no evidence for downflows in magnetic flux tubes. In the area of chromospheric dynamics, several models were put forward recently to reproduce the observed behavior of spicules. However, it is pointed out that these adiabatic models do not include the powerful radiative dissipation which tend to damp out the large amplitude disturbances that produce the spicular acceleration in the models. In the corona, loop flows along field lines clearly transport mass and energy at rates important for the dynamics of these structures. However, advances in understanding the heating and mass balance of the loop structures seem to require new kinds of observations. Some results are presented using a remote sensing diagnostic of the intensity and orientation of macroscopic plasma electric fields predicted by models of reconnective heating and also wave heating.

Foukal, Peter↗