Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Turbulent Acceleration of Interstellar Pickup Ions at the Heliospheric Termination Shock Forms the Global ENA Spectrum

The heliospheric energetic neutral atom spectrum observed by the Interstellar Boundary Explorer (IBEX) reveals that the heliosheath proton distribution is consistent with a power law. The origin of the spectrum is likely from interstellar pickup ions (PUIs) accelerated at the heliospheric termination shock (HTS). We present an explanation of the proton spectrum origin using a test particle simulation of PUIs accelerated at the HTS. PUIs experience preferential heating by the motional electric field in the shock foot, but do not develop a power-law tail without the presence of turbulence at wavenumbers (k) close to the PUI gyroradius scale (R g ). Voyager 2 observations of the magnetic field downstream of the HTS indicate a moderate amount of turbulence at kR g ≅ 1, (δB /B 0 ) 2 @ 0.01, which we find to be sufficient for producing a downstream suprathermal PUI tail but not at intensities observed by IBEX. Within the shock ramp, however, Voyager observed the turbulence power at much smaller scales to be nearly 100 times stronger, suggesting the possibility of strong turbulence at the PUI gyroradius scale. We show that a proton distribution can develop a power law downstream of the HTS consistent with IBEX observations if (δB /B 0 ) 2 ≳ 0.1 at kR g ≅ 1 in the shock foot. Shock drift acceleration of PUIs by the motional electric field is aided by interactions with turbulence upstream of the shock overshoot. Steepening of the IBEX proton spectrum in directions farther from the heliospheric nose suggests the HTS compression ratio and/or turbulence power weakens near the heliotail.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and demonstration of next generation technology for Nb_3Sn accelerator magnets with lower cost, improved performance uniformity, and higher operating point in the 12-14 T range

The scope of the proposal outlined in this white paper is the development and demonstration of the technology needed for next generation of Nb_3Sn accelerator magnets in the 12-14 T range. The main goal is to cut magnet cold-mass cost by a factor 2 or higher with respect to the Nb_3Sn magnets produced by the US Accelerator Upgrade Project (AUP) for the High-Luminosity Large Hadron Collider (HL-LHC). This goal will be achieved by significant reduction of labor hours, higher operating point, and improved performance uniformity. A key factor will be automation that will be achieved through industry involvement and benefitting from the experience gained in US national laboratories through the production of the AUP magnets. This partnership will enable the development of a technology that will be easily transferable to industry for mid- and large-scale production of Nb_3Sn accelerator magnets in the 12-14 T range. This step is essential to enable next generation of colliders such as the FNAL-proposed Muon Collider, FCC and other HEP hadron colliders. This is a Directed R&D where direction is given by the field range and industry involvement for high-automation and industry-ready technology. The plan includes ten milestones, to be achieved in 6-8 years at the cost of 5-7 $M/year.

43 PARTICLE ACCELERATORS↗

Finding Beam Loss Locations at PIP2IT Accelerator With Oscillating Dipole Correctors

The PIP2IT accelerator was assembled in multiple stages in 2014 - 2021 to test concepts and components of the future PIP-II linac that is being constructed at Fermilab. In its final configuration, PIP2IT accelerated a 0.55 ms x 20 Hz x 2 mA H- beam to 16 MeV. To determine location of the beam loss in the accelerators low-energy part, where radiation monitors are ineffective, a method using oscillating trajectories was implemented. If the beam is scraped at an aperture limitation, moving its centroid with two dipole correctors located upstream and oscillating in sync, produces a line at the corresponding frequency in spectra of BPM sum signals downstream of the loss point. Comparison of these responses along the beam line allows to find the loss location. The paper describes the method and results of its implementation at PIP2IT.

43 PARTICLE ACCELERATORS↗

Beam Optics Design of a Prototype 20 KW Conduction-cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

Superconducting low-beta Nb 3 Sn cavity for ATLAS and future ion accelerators

We report on a Nb 3 Sn-coated low-beta superconducting radio frequency (RF) cavity intended for accelerating ions. We aim to apply the cavity in ATLAS, our Argonne National Laboratory user facility for nuclear physics studies with ion beams in the energy range of 5–20 MeV u −1 . The Nb 3 Sn-coated cavity, a 145 MHz quarter-wave optimized for ions moving with velocity β = $v/c$ = 0.08 exhibits an order-of-magnitude reduction in RF losses into helium at 4.4 K compared to a superconducting niobium (Nb) cavity at the same frequency and temperature. Experimentally measured fields are among the highest to date for any Nb 3 Sn-coated cavity, reaching a peak surface magnetic field of 105 mT. We also present a practical solution to the problem of cavity frequency tuning. Tuning by mechanical deformation has been a challenge with Nb 3 Sn due to its brittle nature, however, using a set of techniques tailored to the properties of thin-film Nb 3 Sn on Nb, we can repeatably tune the cavity to the ATLAS master clock frequency after it is cooled, while maintaining the excellent performance characteristics. The same Nb 3 Sn cavity technology offers broad benefits for future ion accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Subfemtosecond Wakefield Injector and Accelerator Based on an Undulating Plasma Bubble Controlled by a Laser Phase

Here, we demonstrate that a long-propagating plasma bubble executing undulatory motion can be produced in the wake of two copropagating laser pulses: a near-single-cycle injector and a multicycle driver. When the undulation amplitude exceeds the analytically derived threshold, highly localized injections of plasma electrons into the bubble are followed by their long-distance acceleration. While the locations of the injection regions are controlled by the carrier-envelope phase (CEP) of the injector pulse, the monoenergetic spectrum of the accelerated subfemtosecond high-charge electron bunches is shown to be nearly CEP independent.

43 PARTICLE ACCELERATORS↗

Single-Shot Diagnosis of Electron Energy Evolution via Streaked Betatron X Rays in a Curved Laser Wakefield Accelerator

We report on an experimental observation of the streaking of betatron x rays in a curved laser wakefield accelerator. The streaking of the betatron x rays was realized by launching a laser pulse into a plasma with a transverse density gradient. By controlling the plasma density and the density gradient, we realized the steering of the laser driver, electron beam, and betatron x rays simultaneously. Furthermore, we observed an energy-angle correlation of the streaked betatron x rays and utilized it in diagnosing the electron acceleration process in a single-shot mode. Our work could also find applications in advanced control of laser beam and particle propagation. More importantly, the angular streaked betatron x ray has an intrinsic spatiotemporal correlation, which makes it a promising tool for single-shot pump-probe applications.

43 PARTICLE ACCELERATORS↗

Cost-efficiency enhancement of X- and Ku-band split waveguides for industrial accelerators

Compact microwave electron linear accelerators must operate at high frequencies in order to maintain tight SWaP (size, weight, and power) requirements, set by modern applications. Currently, the frequencies are practically limited to X- and Ku-bands because of the availability of MW-class magnetrons, required to achieve beam energies of several MeV, and tight fabrication tolerances. The latter is associated with micron-level accuracy and further waveguide frequency tuning process, both increasing its costs dramatically. By implying a novel split structure fabrication approach, it is possible to relax these tolerances to the values of 10–20 μm and eliminate the tuning step, greatly reducing their total costs. Finally, this paper presents the results of microwave measurements of split X- and Ku-band accelerating structures of different types and discusses the benefits of our fabrication approach.

43 PARTICLE ACCELERATORS↗

Hydrodynamic modeling of plasma channel systems for laser plasma accelerators

Structured plasma channels are an essential technology for driving high-gradient, plasma-based acceleration and control of electron and positron beams for advanced concepts accelerators. Laser and gas technologies can permit the generation of long plasma columns known as hydrodynamic, optically-field-ionized (HOFI) channels, which feature low on-axis densities and steep walls. By carefully selecting the background gas and laser properties, one can generate narrow, tunable plasma channels for guiding high intensity laser pulses. Here, we present on the development of simulations of HOFI channels using the FLASH code, a publicly available radiation hydrodynamics code. We explore sensitivities of the channel evolution to laser profile, intensity, and background gas conditions, and identify relevant scalings with laser intensity through a range of practical channel delays.

Accelerators↗

On possibility of low-emittance high-energy muon source based on plasma wakefield acceleration

We report plasma wakefield acceleration (PWA) channels are characterized by very high accelerating gradients and very strong focusing fields. We propose to employ these properties for effective production of low emittance high energy muon beams, consider muon beam dynamics in the PWFA cell and analyze various options and potential of the PWA-based muon sources.

43 PARTICLE ACCELERATORS↗

Tau tridents at accelerator neutrino facilities

We present the first detailed study of Standard Model neutrino tridents involving tau leptons at the near detectors of accelerator neutrino facilities. The rates of these processes were previously thought to be negligible, even at future facilities. Our full 2 → 4 calculation, including both coherent and incoherent scatterings, reveals that the DUNE near detector could observe a considerable number of tau tridents—an important background to new physics searches. We identify promising kinematic features that may allow distinction of tau tridents from the usual neutrino charged-current background at DUNE, and thus establish the observation of tau tridents for the first time. We also comment on the detection prospects at other accelerator and collider neutrino experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stable Positron Acceleration in Thin, Warm, Hollow Plasma Channels

Hollow plasma channels are attractive for lepton acceleration for providing intrinsic emittance preservation regimes. However, beam breakup instabilities dominate the dynamics. Here, we show that thin, warm hollow channels can sustain large-amplitude plasma waves ready for high-quality positron acceleration. We verify that the combination of warm electrons and thin hollow channels enables positron focusing structures. Such focusing wakefields unlock beam breakup damping mechanisms. We demonstrate that such channels emerge self-consistently during the long-term plasma dynamics in the blowout's regime aftermath, allowing for experimental demonstration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrabroad-band x-ray source using a picosecond, laser-driven plasma accelerator

An ultrabroad-band x-ray source, with photon energies from 10 keV to >1 MeV, based on a picosecond laser-driven plasma accelerator, is characterized and used to radiograph high-energy-density-science relevant targets. The measured yield of 10 12 photons/shot is reaching the necessary photon yields to radiograph, in a single shot, high areal density objects and matter under extreme conditions. By focusing a short laser pulse (120 J, 1 ps) into a gas jet, a < 100 mrad electron beam with energies up to 350 MeV and up to 70 nC of charge was produced by a combination of laser self-modulation instability and direct laser acceleration. A foil placed at the exit of the gas jet is used to convert part of the electron beam energy into x rays through inverse bremsstrahlung and/or inverse Compton scattering, generating a bright, broad-band, high-photon-energy beam. This beam is used to radiograph a gold half hohlraum with a high-density sphere inside with relevant characteristics for high-energy-density science and inertial confinement fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards continual machine learning for particle accelerators

This talk covers our work on errant beam prognostics at the Spallation Neutron Source (SNS), focusing on the end-to-end process from data collection to the development and deployment of predictive models in specific. A short overview of AIML work done for accelerators and current trends will be presented. We will walk through key steps involved in creating robust Machine Learning (ML) models, including model training, validation, and deployment in an operational setting. In addition to presenting our technical approach, we will share valuable lessons learned, emphasizing the importance of infrastructure to support the continuous adaptation of models to evolving data and system behaviors. This talk will provide insights into the challenges and solutions involved in applying ML to real-world operational environments, with a particular focus on managing data drift and changes in accelerator setup while ensuring model resilience over time.

Accelerator Physics↗

Heating and acceleration of ions with Kappa distribution functions by low‐frequency Alfvén wave

Abstract Heating and acceleration of ions with Kappa distribution functions (with parameter ) in low‐beta plasmas, by a low‐frequency Alfvén wave, is investigated using test‐particle simulations, yielding interesting new results. As long as the Alfvén wave amplitude is sufficiently large, the computed net heating energy of ions becomes independent of the wave frequency and amplitude, always approaching the same value of . The eventual energy of ions is dictated only by the initial ion energy and the ratio of the magnetic field energy density to the plasma density. The heating effect of the Kappa ions increases with . During the heating process, the ions are picked up by the Alfvén wave and pitch angle scattered, forming a quasi‐isotropic spherical shell velocity distribution. The Kappa ions are accelerated in the parallel direction, reaching a bulk flow speed roughly equal to the local Alfvén speed. Higher ‐value in the initial Kappa distribution leads to faster saturation. The above results may explain certain features of the ion heating and acceleration in the solar wind and corona.

Li, Kehua↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine-Learning Accelerated Studies of Materials with High Performance and Edge Computing

In the studies of materials, experimental measurements often serve as the reference to verify physics theory and modeling; while theory and modeling provide a fundamental understanding of the physics and principles behind. However, the interactions and cross validation between them have long been a challenge even to-date. Not only that inferring a physics model from experimental data is itself a difficult inverse problem, another major challenge is the orders-of-magnitude longer wall-clock time required to carry out high-fidelity computer modeling to match the timescale of experiments. We envisage that by combining high performance computing, data science, and edge computing technology, the current predicament can be alleviated, and a new paradigm of data-driven physics research will open up. For example, we can accelerate computer simulations by first performing the large-scale modeling on high performance computers and train a machine-learned surrogate model. This computationally inexpensive surrogate model can then be transferred to the computing units residing closely to the experimental facilities to perform high-fidelity simulations at a much higher throughout. The model will also be more amenable to analyzing and validating experimental observations in comparable time scales at a much lower computational cost. Further integration of these accelerated computer simulations with an outer machine learning loop can also inform and direct future experiments, while making the inverse problem of physics model inference more tractable. We will demonstrate a proof-of-concept by using a quantum Monte Carlo application, Dynamical Cluster Approximation (DCA++), to machine-learn a surrogate model and accelerate the study of quantum correlated materials.

Li, Ying Wai↗

Multichannel Analysis of Surface Waves Accelerated (MASWAccelerated): Software for efficient surface wave inversion using MPI and GPUs

Multichannel Analysis of Surface Waves (MASW) is a technique frequently used in geotechnical engineering and engineering geophysics to infer 1D layered models of seismic shear wave velocities in the top tens to hundreds of meters of the subsurface. We aim to accelerate MASW calculations by capitalizing on modern computer hardware available in the workstations of most engineers: multiple cores and graphics processing units (GPUs). We propose new parallel and GPU accelerated algorithms for computing 1D MASW inversion, and provide software implementations in C using Message Passing Interface (MPI) and CUDA. These algorithms take advantage of sparsity that arises in the problem, and the work balance between processes considers typical data trends. We compare our methods to an existing open source Matlab MASW tool. Our serial C implementation achieves a 2x speedup over the Matlab software, and we continue to see improvements by parallelizing the problem with MPI. Here we see nearly perfect strong and weak scaling for uniform data, and improve strong scaling for realistic data by repartitioning the problem to process mapping. By utilizing GPUs available on most modern workstations, we observe an additional 1.3x speedup over the serial C implementation on the first use of the method. We typically repeatedly evaluate theoretical dispersion curves as part of an optimization procedure, and on the GPU the kernel can be cached for faster reuse on later runs. We observe a 3.2x speedup on the cached GPU runs compared to the serial C runs. This work is the first open-source parallel or GPU-accelerated software tool for MASW imaging, and should enable geotechnical engineers to fully utilize all computer hardware at their disposal.

58 GEOSCIENCES↗