Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ablator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Radiofrequency Ablation of Liver Tumors in Combination with Local OK-432 Injection Prolongs Survival and Suppresses Distant Tumor Growth in the Rabbit Model with Intra- and Extrahepatic VX2 Tumors

Purpose: To evaluate survival and distant tumor growth after radiofrequency ablation (RFA) and local OK-432 injection at a single tumor site in a rabbit model with intra- and extrahepatic VX2 tumors and to examine the effect of this combination therapy, which we termed immuno-radiofrequency ablation (immunoRFA), on systemic antitumor immunity in a rechallenge test. Methods: Our institutional animal care committee approved all experiments. VX2 tumors were implanted to three sites: two in the liver and one in the left ear. Rabbits were randomized into four groups of seven to receive control, RFA alone, OK-432 alone, and immunoRFA treatments at a single liver tumor at 1 week after implantation. Untreated liver and ear tumor volumes were measured after the treatment. As the rechallenge test, tumors were reimplanted into the right ear of rabbits, which survived the 35 weeks and were followed up without additional treatment. Statistical significance was examined by log-rank test for survival and Student's t test for tumor volume. Results: Survival was significantly prolonged in the immunoRFA group compared to the other three groups (P < 0.05). Untreated liver and ear tumor sizes became significantly smaller after immunoRFA compared to controls (P < 0.05). In the rechallenge test, the reimplanted tumors regressed without further therapy compared to the ear tumors of the control group (P < 0.05). Conclusion: ImmunoRFA led to improved survival and suppression of distant untreated tumor growth. Decreases in size of the distant untreated tumors and reimplanted tumors suggested that systemic antitumor immunity was enhanced by immunoRFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Ablation in Combination with Chemotherapy for the Treatment of Advanced Non-Small Cell Lung Cancer

PurposeTo verify whether microwave ablation (MWA) used as a local control treatment had an improved outcome regarding advanced non-small cell lung cancer (NSCLC) when combined with chemotherapy.MethodsThirty-nine patients with histologically verified advanced NSCLC and at least one measurable site other than the ablative sites were enrolled. Primary tumors underwent MWA followed by platinum-based doublet chemotherapy. Modified response evaluation criteria in solid tumors (mRECIST) and RECIST were used to evaluate therapeutic response. Complications were assessed using the National Cancer Institute Common Toxicity Criteria (version 3.0).ResultsMWA was administered to 39 tumors in 39 patients. The mean and median diameters of the primary tumor were 3.84 cm and 3.30 cm, respectively, with a range of 1.00–9.00 cm. Thirty-three (84.6 %) patients achieved a partial response. No correlation was found between MWA efficacy and clinicopathologic characteristics. For chemotherapy, 11 patients (28.2 %) achieved a partial response, 18 (46.2 %) showed stable disease, and 10 (25.6 %) had progressive disease. The overall objective response rate and disease control rate were 28.2 and 74.4 %, respectively. The median progression-free survival time was 8.7 months (95 % CI 5.5–11.9). The median overall survival time was 21.3 months (95 % CI 17.0–25.4). Complications were observed in 22 (56.4 %) patients, and grade 3 adverse events were observed in 3 (7.9 %) patients.ConclusionsPatients with advanced NSCLC could benefit from MWA in combination with chemotherapy. Complications associated with MWA were common but tolerable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Lung Thermal Ablation of Non-surgical Clinical N0 Non-small Cell Lung Cancer: Results of Eight Years’ Experience in 87 Patients from Two Centers

PurposeTo evaluate the survival outcomes of percutaneous thermal ablation (RFA + microwaves) for patients presenting N0 non-small-cell lung cancer (NSCLC) ineligible for surgery.Materials and MethodsEighty-seven patients from two comprehensive cancer centers were included. Eighty-two patients were treated with RFA electrodes and five with microwave antenna. Overall survival (OS) and disease-free survival (DFS) were estimated and predictive factors of local tumor progression, OS and DFS identified and compared by univariate and multivariate analysesResultsMedian follow-up was 30.5 months (interquartile range 16.7–51) and tumor size was 21 mm (range 10–54 mm). Treatment was incomplete for 14 patients with a local tumor progression of 11.5, 18.3, and 21.1 % at 1, 2, and 3 years, respectively. Two patients presented with neurological (grade III or IV) complications, and one died of respiratory and multivisceral failure as a result of the procedure at 29 days. In univariate analysis, increasing tumor size (P = 0.003) was the only predictive factor related to risk of local tumor progression. 5-year OS and DFS were 58.1 and 27.9 %, respectively. Sex (P = 0.044), pathology (P = 0.032), and tumor size >2 cm (P = 0.046) were prognostic factors for DFS. In multivariate analysis, pathology (P = 0.033) and tumor size >2 cm (P = 0.032) were independent prognostic factors for DFS.ConclusionsOversized and overlapping ablation of N0 NSCLC was well tolerated, effective, with few local tumor progressions, even over long-term follow-up. Increasing tumor size was the main prognostic factor linked to OS, DFS, and local tumor progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize the tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Antibiotic Prophylaxis for Percutaneous Radiofrequency Ablation (RFA) of Primary Liver Tumors Necessary? Results From a Single-Center Experience

PurposeThe purpose of this study was to evaluate need for antibiotic prophylaxis for radiofrequency ablation (RFA) of liver tumors in patients with no significant co-existing risk factors for infection.Materials and MethodsFrom January 2004 to September 2013, 83 patients underwent 123 percutaneous RFA procedures for total of 152 hepatocellular carcinoma (HCC) lesions. None of the patients had pre-existing biliary enteric anastomosis (BEA) or any biliary tract abnormality predisposing to ascending biliary infection or uncontrolled diabetes mellitus. No pre- or post-procedure antibiotic prophylaxis was provided for 121 procedures. Data for potential risk factors were reviewed retrospectively and analyzed for the frequency of infectious complications, including abscess formation.ResultsOne patient (1/121 (0.8 %) RFA sessions) developed a large segment 5 liver abscess/infected biloma communicating with the gallbladder 7 weeks after the procedure, successfully treated over 10 weeks with IV and PO antibiotic therapy and percutaneous catheter drainage. This patient did not receive any antibiotics prior to RFA. During the procedure, there was inadvertent placement of RFA probe tines into the gallbladder. No other infectious complications were documented.ConclusionThese data suggest that the routine use of prophylactic antibiotics for liver RFA is not necessary in majority of the patients undergoing liver ablation for HCC and could be limited to patients with high-risk factors such as the presence of BEA or other biliary abnormalities, uncontrolled diabetes mellitus, and large centrally located tumors in close proximity to central bile ducts. Larger randomized studies are needed to confirm this hypothesis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography (CBCT) Versus CT in Lung Ablation Procedure: Which is Faster?

AimTo compare cone-beam CT (CBCT) versus computed tomography (CT) guidance in terms of time needed to target and place the radiofrequency ablation (RFA) electrode on lung tumours.Materials and MethodsPatients at our institution who received CBCT- or CT-guided RFA for primary or metastatic lung tumours were retrospectively included. Time required to target and place the RFA electrode within the lesion was registered and compared across the two groups. Lesions were stratified into three groups according to their size (<10, 10–20, >20 mm). Occurrences of electrode repositioning, repositioning time, RFA complications, and local recurrence after RFA were also reported.ResultsForty tumours (22 under CT, 18 under CBCT guidance) were treated in 27 patients (19 male, 8 female, median age 67.25 ± 9.13 years). Thirty RFA sessions (16 under CBCT and 14 under CT guidance) were performed. Multivariable linear regression analysis showed that CBCT was faster than CT to target and place the electrode within the tumour independently from its size (β = −9.45, t = −3.09, p = 0.004). Electrode repositioning was required in 10/22 (45.4 %) tumours under CT guidance and 5/18 (27.8 %) tumours under CBCT guidance. Pneumothoraces occurred in 6/14 (42.8 %) sessions under CT guidance and in 6/16 (37.5 %) sessions under CBCT guidance. Two recurrences were noted for tumours receiving CBCT-guided RFA (2/17, 11.7 %) and three after CT-guided RFA (3/19, 15.8 %).ConclusionCBCT with live 3D needle guidance is a useful technique for percutaneous lung ablation. Despite lesion size, CBCT allows faster lung RFA than CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

18F-FDOPA PET/CT-Guided Radiofrequency Ablation of Liver Metastases from Neuroendocrine Tumours: Technical Note on a Preliminary Experience

AimTo review our preliminary experience with 6-l-18F-fluorodihydroxyphenylalanine (18F-FDOPA) PET/CT-guided radiofrequency ablation (RFA) of liver metastases from neuroendocrine tumours (NETs).Materials and MethodsThree patients (mean age 51.3 years; range 43–56) with gastro-entero pancreatic NET (GEP-NET) liver metastases underwent 18F-FDOPA PET/CT-guided RFA. Patients were referred with oligometastatic hepatic-confined disease (1–6 metastases; <3 cm) on 18F-FDOPA PET/CT; poor lesion visualisation on US, CT, and MR; and ongoing symptoms. Procedures were performed in an interventional PET/CT scanner under general anaesthesia using a split-dose protocol. Lesion characteristics, procedural duration and technical success (accurate probe placement and post-procedural ablation-zone photopaenia), complications, patient and operator dose, and clinical outcomes were evaluated.ResultsThirteen liver metastases (mean size 11.4 mm, range 8–16) were treated in three patients (two presented with “carcinoid syndrome”). Technical success was 100 % with a mean procedural duration of 173.3 min (range 90–210) and no immediate complications. Mean patient dose was 2844 mGy·cm (range 2104–3686). Operator and radiographer doses were acceptable other than the operator’s right hand in the first case (149 µSv); this normalised in the second case. There was no local tumour or extra-hepatic disease progression at mid-term follow-up (mean 12.6 months; range 6–20); however, two cases progressed with new liver metastases at different sites. There was 100 % clinical success (n = 2) in resolving carcinoid syndrome symptoms.Conclusion18F-FDOPA PET/CT-guided RFA appears technically feasible, safe, and effective in patients with GEP-NETs and low-burden hepatic metastases. Further prospective studies are required to elucidate its precise role in tailored multimodality management of GEP-NET liver metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

23 Lung Metastases Treated by Radiofrequency Ablation Over 10 Years in a Single Patient: Successful Oncological Outcome of a Metastatic Cancer Without Altered Respiratory Function

An 82-year-old man, who was diagnosed in 2002 with an oncocytic (Hürthle cell) thyroid carcinoma, was initially treated by local surgery and was refractory to radioiodine treatment. The patient had successive secondary recurrences from 2006 onwards. Metastases were suspected due to an elevation of thyroglobulin in serum. Hypermetabolic nodules were targeted using FDG PET as well as CT-guided radiofrequency ablations. Thyroglobulin levels decreased following each procedure. 10 years later, tolerance and efficacy are excellent; 23 lung metastases have been treated during 11 sessions without current relapse. Respiratory function and quality of life are not altered. This report illustrates how radiofrequency ablation can be efficiently integrated into the long-term management of poorly aggressive oligometastatic cancer, in combination with other local and/or systemic therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Nonrigid Registration of Pre-Procedure MR with Post-Procedure CT After Radiofrequency Ablation for Hepatocellular Carcinoma

PurposeTo evaluate the value of pre-radiofrequency ablation (RFA) MR and post-RFA CT registration for the assessment of the therapeutic response of hepatocellular carcinoma (HCC).Materials and MethodsA total of 178 patients with single HCC who received RFA as an initial treatment and had available pre-RFA MR and post-RFA CT images were included in this retrospective study. Two independent readers (one experienced radiologist, one inexperienced radiologist) scored the ablative margin (AM) of treated tumors on a four-point scale (1, residual tumor; 2, incomplete AM; 3, borderline AM; 4, sufficient AM), in two separate sessions: (1) visual comparison between pre-and post-RFA images; (2) with addition of nonrigid registration for pre- and post-RFA images. Local tumor progression (LTP) rates between low-risk (response score, 3–4) and high-risk groups (1–2) were analyzed using the Kaplan–Meier method at each interpretation session.ResultsThe patients’ reassignments after using the registered images were statistically significant for inexperienced reader (p < 0.001). In the inexperienced reader, LTP rates of low- and high-risk groups were significantly different with addition of registered images (session 2) (p < 0.001), but not significantly different in session 1 (p = 0.101). However, in the experienced reader, LTP rates of low- and high-risk groups were significantly different in both interpretation sessions (p < 0.001). Using the registered images, the cumulative incidence of LTP at 2 years was 3.0–6.6%, for the low-risk group, and 18.6–27.8% for the high-risk group.ConclusionRegistration between pre-RFA MR and post-RFA CT images may allow better assessment of the therapeutic response of HCC after RFA, especially for inexperienced radiologists, helping in the risk stratification for LTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Percutaneous Intrahepatic Split by Microwave Ablation (PISA) After Portal Vein Embolization for Hypertrophy of Future Liver Remnant: The Radiological Stage-1 ALPPS

PurposeTo assess the feasibility of radiological stage-1 ALPPS, associating liver partition and portal vein ligation for staged hepatectomy, by combining portal vein embolization (PVE) with percutaneous intrahepatic split by ablation (PISA).Materials and MethodsThree patients (mean age 65.0 ± 7.3 years) underwent PVE and PISA. PISA was performed 21 days after PVE by microwave ablation to create a continuous intrahepatic cutting plane. Abdominal CT examinations were performed before and after PVE and PISA. The future liver remnant (FLR) volume was calculated by semiautomatic segmentation, and increase was reported as a percentage of the pre-procedural volume. The FLR/body weight (FLR/BW) ratio was calculated; a ratio greater than 0.8% was considered sufficient for guaranteeing adequate liver function after surgery. The liver function before and after PISA was also evaluated by 99mTc-mebrofenin hepatobiliary scintigraphy. Patients’ laboratory tests, performance status, ability to walk were assessed before and after PVE and PISA procedures.ResultsNo procedure-related complications were recorded. The FLR volume increase in each patient was 42.0, 33.1 and 30.4% within 21 days of PVE and 109.3, 68.1 and 71.7% within 10 days after PISA. The FLR/BW ratios were 0.76, 0.66, 0.63% and 1.13, 0.83, 0.83% after PVE and PISA procedures, respectively. Two patients underwent successful right hepatectomy; in one patient, despite 1.13% FLR/BW, surgery was not performed because of the absolute rejection of blood transfusion due to the patient’s religious convictions.ConclusionRadiological stage-1 ALPPS is a feasible, minimally invasive option to be further investigated to become an effective alternative to surgical stage-1 ALPPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Faraday detector uranium isotope ratio measurement: Insights from solution- and laser ablation-based sampling methodologies on the Neoma MC-ICP-MS

In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 10 11 vs 10 13 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser ablation of high-loading Li-ion battery electrodes improves accessible capacity and cycle life for Behind-the-Meter Storage

Adoption of Behind-the-Meter Storage (BTMS) requires design of batteries that enable high safety, long cycle life, and low cost at the system level. Pairing Li 4 Ti 5 O 12 (LTO) with LiMn 2 O 4 (LMO) achieves targets related to safety and cycle life, but these materials' low energy densities contribute to higher cost at the system scale. Increasing electrode loading is a simple approach to improve energy density, but comes with a trade-off in electrode utilization due to long, tortuous Li + diffusion pathways. Here, laser ablation is used to microstructure (pattern) high-loading electrodes to enhance electrode performance through improved Li + diffusion pathways. Four cell types, comprising combinations of standard or patterned anode and cathode, were prepared to evaluate the effects of laser ablation at each electrode. A rate test shows that patterning electrodes enhances active material utilization at ≳1C rates. Patterning the cathode yields the most benefit, as cells with a patterned cathode demonstrate a ~20% higher accessible capacity than those without at 1.4C. Additionally, 1C capacity retention of cells with patterned cathode (91% through 3000 cycles) is significantly improved over cells with only the anode patterned (64%) and non-patterned electrodes (50%). Characterization of post-mortem cells before and after refreshing their electrolyte suggests that 1C capacity retention is improved by mitigation of electrode "dry-out". We hypothesize that the microstructure acts as a reservoir of additional electrolyte, or a path for gas to escape, so that active material remains wetted throughout long-term cycling, and/or the microstructure may reduce localized, gas-forming overpotentials in the high-loading electrode.

25 ENERGY STORAGE↗

Al-Si-N thin films deposited by laser ablation: Effect of plasma parameters on mechanical and optical properties

Highlights: • Al-Si-N thin films deposited by PLD showed a chemical composition of the films dependent on the silicon plasma density. • The change in the direct band gap of the samples was related to the Si content and the maximum was 5.54 eV for 20 at.% of Si. • Maximum hardness of 30.3 ± 1.5 GPa was obtained at 4 at.% Si. • The increase in the silicon content of Al-Si-N thin films promotes the formation of a-Si{sub 3}N{sub 4} matrix. - Abstract: Al-Si-N thin films were deposited using simultaneous laser ablation of silicon and aluminum targets in a nitrogen atmosphere at a substrate temperature of 200 °C. The silicon content of the films was studied as a function of the plasma parameters (mean ion kinetic energy and plasma density), produced by the ablation of the silicon target. The plasma parameters were measured by means of a planar Langmuir probe and optical emission spectroscopy. The chemical composition of the films was determined by X-ray photoelectron spectroscopy. The results showed a dependence between the silicon content and the silicon plasma density. Optical emission spectroscopy measurements showed that variations of the working pressure produced changes in the intensity of excited species (N{sub 2}{sup +}, Si{sup 2+}, Al{sup +} and Al{sup 0}), and in the incorporation of these elements into the films. For a working pressure of 0.6 Pa, hardness measurements gave a maximum of 30 ± 1.5 GPa for a silicon content of 4 at.%. The optical constants (refractive index and extinction coefficient) and direct band gap were evaluated as a function of the silicon content in the films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser ablation molecular isotopic spectrometry of carbon isotopes

Quantitative determination of carbon isotopes using Laser Ablation Molecular Isotopic Spectrometry (LAMIS) is described. Optical emission of diatomic molecules CN and C 2 is used in these measurements. Two quantification approaches are presented:empirical calibration of spectra using a set of reference standards and numerical fitting of a simulated spectrum to the experimental one. Formation mechanisms of C 2 and CN in laser ablation plasma are briefly reviewed to provide insights for implementation of LAMIS measurements. A simulated spectrum of the 12 C 2 Swan system was synthesized using four constituents within 473.5–476.5 nm. Simulation included three branches of 12 C 2 (1-0), branches R(0-0) and R(1-1), and branch P(9-8) of 12 C 2 . Spectral positions of the tail lines in R(0-0) and R(1-1) were experimentally measured, since they were not accurately known before. The Swan band (1-0) of the isotopologue 13 C 12 C was also simulated. Fitting to the experimental spectrumyielded the ratio 13 C/ 12 C = 1.08% in a good agreement with measurements by isotope ratio mass spectrometry. LAMIS promises to be useful in coal, oil and shale exploration, carbon sequestration monitoring, and agronomy studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of rare earth elements in coal fly ash using laser ablation inductively coupled plasma mass spectrometry and scanning electron microscopy

Reference standard NIST SRM 1633b and FA 345, a fly ash sample from an eastern U.S. coal power plant, were analyzed to determine and quantify the mineralogical association of rare earth elements (REE). These analyses were completed using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and a scanning electron microscope, equipped with an energy-dispersive X-ray spectrometer (SEM-EDS). Internal standardization was avoided by quantifying elemental concentrations by normalizing to 100% oxides. Mineral grains containing elevated REE concentrations were found in diverse chemical environments, but were most commonly found in regions where Al and Si were predominant. Dividing the spot analyses into time segments yielded plots that showed the REE content changing over time as individual mineral grains were being ablated. SEM-EDS images of FA 345 confirmed the trends that were found in the LA-ICP-MS results. Small grains of apatite, monazite, or zircon were frequently observed as free mineral grains or embedded in amorphous aluminosilicate glass and were not associated with ferrous particles. This finding is consistent with previous reports that magnetic enrichment may be an effective way of concentrating non-magnetic REE phases. Moreover, aggressive mechanical and chemical-based separation schemes will be required to separate and recover REE from aluminosilicate glass.

01 COAL, LIGNITE, AND PEAT↗

Shock wave mediated plume chemistry for molecular formation in laser ablation plasmas

Laser ablation is used in a variety of applications albeit formation mechanisms of molecules and nanoclusters are not well understood. We investigated the formation mechanisms of AlO molecules during complex interactions between an Al laser plume expanding into ambient air at atmospheric pressure levels. To produce the plasma a high-purity Al target was ablated using 1064 nm, 6 ns laser pulses. Our results show that the plasma chemistry leading to the formation of AlO is mediated by shock waves. During the early times of plasma expansion, the generated shock waves at the plume edges act as a barrier for the combustion process and the molecular formation is prevalent after the shockwave collapse. The temporally and spatially resolved contour mapping of Al and AlO highlight the formation routes and persistence of species in the plasma and its relation to plume hydrodynamics.

2D fast imaging↗

Ambient Metabolic Profiling and Imaging of Biological Samples with Ultrahigh Molecular Resolution using Laser Ablation Electrospray Ionization 21 Tesla FTICR Mass Spectrometry

Mass spectrometry (MS) has been an indispensable analytical tool in capturing the complexity and array of biomolecules within biological systems. However, conventional MS-based analytical workflows are limited in both throughput and measuring the native molecular state these systems, due in large part to sample handling and preparation. The development of ambient ionization methods capable of sampling directly from tissues circumvent many of these issues but requires the use of high-performance MS to resolve the molecular complexity within these samples. Herein, we demonstrate the unique combination of laser ablation electrospray ionization (LAESI) coupled with a 21 Tesla Fourier transform ion cyclotron resonance (21T-FTICR-MS) for MS imaging applications. This analytical platform provides isotopic fine structure information directly from native tissues, delivering a higher degree of confidence for molecular identification. The ability to capture and visualize the complex metabolic behavior of living organisms in situ is a bioanalytical grand challenge that has yet to be fully realized. Due to their excellent sensitivity and selectivity, mass spectrometry (MS)-based platforms offer a unique opportunity to characterize an array of biomolecules from a variety of biological samples.[1] One method in particular, MS imaging (MSI), has demonstrated the ability to simultaneously determine the spatial distributions for hundreds of biomolecules, e. g., metabolites, lipids, peptides, and xenobiotics, within complex biological systems simultaneously.[2-3] Matrix-assisted laser desorption/ionization (MALDI)-MSI remains the most common of these methods.[4] However, the application of an exogenous matrix, and the limited availability of commercial sources that operate under atmospheric pressure,[5] has significantly prohibited the ability of MALDI to be useful for biomolecular mapping of living systems. Ambient ionization methods that require minimal to no sample preparation, like desorption electrospray ionization (DESI and nano-DESI) and laser ablation electrospray ionization (LAESI), demonstrated the ability to spatially map biomolecule distributions within live organisms.

Mass Spectometry, fourier transform ion cyclostron↗

Selectively accessing the hotspots of optical nanoantennas by self-aligned dry laser ablation

Plasmonic nanostructures serve as optical antennas for concentrating the energy of incoming light in localized hotspots close to their surface. By positioning nanoemitters in the antenna hotspots, energy transfer is enabled, leading to novel hybrid antenna-emitter-systems, where the antenna can be used to manipulate the optical properties of the nano-objects. The challenge remains how to precisely position emitters within the hotspots. We report a self-aligned process based on dry laser ablation of a calixarene that enables the attachment of molecules within the electromagnetic hotspots at the tips of gold nanocones. Within the laser focus, the ablation threshold is exceeded in nanoscale volumes, leading to selective access of the hotspot areas. A first indication of the site-selective functionalization process is given by attaching fluorescently labelled proteins to the nanocones. In a second example, Raman-active molecules are selectively attached only to nanocones that were previously exposed in the laser focus, which is verified by surface enhanced Raman spectroscopy. Enabling selective functionalization is an important prerequisite e.g. for preparing single photon sources for quantum optical technologies, or multiplexed Raman sensing platforms.

77 NANOSCIENCE AND NANOTECHNOLOGY↗