Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aberrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Wavefront analysis of the laser beam propagating through a turbid medium

Laser beam propagation through a scattering suspension of polystyrene microspheres in distilled water is studied theoretically and experimentally. The dependence of wavefront aberrations on the particle concentration is investigated. The existence of symmetric wavefront aberrations of the laser beam passed through a turbid medium is shown. (light scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement and correction of the wavefront of the laser light in a turbid medium

We report a numerical and experimental study of the laser beam propagation through a suspension of polystyrene microspheres in distilled water, showing the presence of higher-order centrally symmetric aberrations for the scatterer concentrations in the range from 1.3 × 10{sup 5} to 10{sup 6} mm{sup −3} and analysing the dependence of the scattered light wavefront distortion on the concentration of particles in a turbid medium. The study has also shown the effectiveness of the compensation of the wavefront aberrations of a scattered laser beam using a bimorph adaptive mirror. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Features of correlation measurements of the parameters of pulsed hyperspectral optical fields using an asymmetric interferometer

Differences in correlation measurements of the parameters of pulsed hyperspectral optical fields using symmetric and asymmetric interferometers are considered. It is shown analytically that the resulting cross-correlation function is sensitive to phase perturbations in the original wave field. The considered setup, which contains a telescopic reflective 4f system of parabolic mirrors in one arm, demonstrates that in the case of an asymmetric interferometer, the presence of aberrations leads to degradation of the reconstructed image, whereas in the case of symmetric interferometers these aberrations do not affect the result. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of sunitinib resistance on clear cell renal cell carcinoma therapeutic sensitivity in vitro

Sunitinib resistance creates a major clinical challenge for the treatment of advanced clear cell renal cell carcinoma (ccRCC) and functional and metabolic changes linked to sunitinib resistance are not fully understood. We sought to characterize the molecular and metabolic changes induced by the development of sunitinib resistance in ccRCC by developing and characterizing two human ccRCC cell lines resistant to sunitinib. Consistent with the literature, sunitinib-resistant ccRCC cell lines presented an aberrant overexpression of Axl and PD-L1, as well as a metabolic rewiring characterized by enhanced OXPHOS and glutamine metabolism. Therapeutic challenges of sunitinib-resistant ccRCC cell lines in vitro using small molecule inhibitors targeting Axl, AMPK and p38, as well as using PD-L1 blocking therapeutic antibodies, showed limited CTL-mediated cytotoxicity in a co-culture model. However, the AMPK activator metformin appears to sensitize the effect of PD-L1 blocking therapeutic antibodies and to enhance CTLs’ cytotoxic effects on ccRCC cells. These effects were not broadly observed with the Axl and the p38 inhibitors. Taken together, these data suggest that targeting certain pathways aberrantly activated by sunitinib resistance such as the AMPK/PDL1 axis might sensitize ccRCC to immunotherapies as a second-line therapeutic approach.

59 BASIC BIOLOGICAL SCIENCES↗

On the significance of power asymmetries in Planck CMB data at all scales

We perform an analysis of the CMB temperature data taken by the Planck satellite investigating if there is any significant deviation from cosmological isotropy. We look for differences in the spectrum between two opposite hemispheres and also for dipolar modulations. We propose a new way to avoid biases due to partial-sky coverage by producing a mask symmetrized in antipodal directions, in addition to the standard smoothing procedure. We also properly take into account both Doppler and aberration effects due to our peculiar velocity and the anisotropy of the noise, since these effects induce a significant hemispherical asymmetry. We are thus able to probe scales all the way to ℓ = 2000. After such treatment we find no evidence for significant hemispherical anomalies along any of the analyzed directions (i.e. deviations are less than 1.5σ when summing over all scales). Although among the larger scales there are sometimes higher discrepancies, these are always less than 3σ. We also find results on a dipolar modulation of the power spectrum. Along the hemispheres aligned with the most asymmetric direction for 2 ≤ ℓ ≤ 2000 we find a 3.3σ discrepancy when comparing to simulations. However, if we do not restrict ourselves to Planck's maximal asymmetry axis, which can only be known a posteriori, and compare Planck data with the modulation of simulations along their respective maximal asymmetry directions, the discrepancy goes down to less than 1σ (with, again, almost 3σ discrepancies in some low-ℓ modes). We thus conclude that no significant power asymmetries seem to be present in the full data set. Interestingly, without proper removal of Doppler and aberration effects one would find spurious anomalies at high ℓ, between 3σ and 5σ. Even when considering only ℓ < 600 we find that the boost is non-negligible and alleviates the discrepancy by roughly half-σ.

79 ASTRONOMY AND ASTROPHYSICS↗

Unsupported single-atom-thick copper oxide monolayers

Oxide monolayers may present unique opportunities because of the great diversity of properties of these materials in bulk form. However, reports on oxide monolayers are still limited. Here we report the formation of single-atom-thick copper oxide layers with a square lattice both in graphene pores and on graphene substrates using aberration-corrected scanning transmission electron microscopy. First-principles calculations find that CuO is energetically stable and its calculated lattice spacing matches well with the measured value. Furthermore, free-standing copper oxide monolayers are predicted to be semiconductors with band gaps ~3 eV. The new wide-bandgap single-atom-thick copper oxide monolayers usher a new frontier to study the highly diverse family of two-dimensional oxides and explore their properties and their potential for new applications.

2D materials↗

Translocations are induced in hematopoietic stem cells after irradiation of fetal mice

Abstract Although mammalian fetuses have been suggested to be sensitive to radiation, an increased frequency of translocations was not observed in blood lymphocytes from atomic bomb (A-bomb) survivors who were exposed to the bomb in utero and examined as adults. Since experiments using hematopoietic cells of mice and rats confirmed this finding, it was hypothesized that either irradiated fetal hematopoietic stem cells (f-HSCs) cannot generate exchange-type chromosomal aberrations or cells bearing induced aberrations are eliminated before the animals reach adulthood. In the present study, pregnant mice (12.5–15.5 days post coitum [dpc]) were irradiated with 2 Gy of X-rays and long-term HSCs (LT-HSCs) were isolated 24 h later. Multicolor fluorescence in situ hybridization (mFISH) analysis of LT-HSC clones proliferated in vitro showed that nine out of 43 (21%) clones from fetuses and 21 out of 41 (51%) clones from mothers bore translocations. These results indicate that cells with translocations can arise in mouse f-HSCs but exist at a lower frequency than in the mothers 24 h after X-ray exposure. Thus, it seems likely that translocation-bearing f-HSCs are generated but subsequently disappear, so that the frequency of lymphocyte translocations may decrease and reach the control level by the time the animals reach adulthood.

60 APPLIED LIFE SCIENCES↗

Focused Interest Groups Propel Innovation in the Emerging Data-Driven Hardware Ecosystem

Over the past several decades, the science of electron microscopy (EM) has risen to become one of the cornerstone approaches to understanding material structure, chemistry, and defects at exceptional spatial resolution. This rise can be attributed to the hard work of researchers and companies who have pushed the bounds of instrumentation and analysis, but it is also the result of advocacy by members of professional societies. Furthermore, such advocacy is exemplified by the Aberration Corrected EM (ACEM) focused interest group (FIG) of the Microscopy Society of America (MSA), which has played an important role in facilitating new hardware developments, promoting the exchange of ideas to catalyze discovery, and building the next generation of leaders in electron microscopy. From the early 2000s to the present, aberration correction has moved from proof-of-concept instrumentation to an established technique, providing unprecedented improvements in spatial and chemical resolution for breakthroughs in chemistry, physics, and materials science.

47 OTHER INSTRUMENTATION↗

Microfocusing at the PG1 beamline at FLASH

The Kirkpatrick–Baez (KB) refocusing mirror system installed at the PG1 branch of the plane-grating monochromator beamline at the soft X-ray/XUV free-electron laser in Hamburg (FLASH) is designed to provide tight aberration-free focusing down to 4 µm × 6 µm full width at half-maximum (FWHM) on the sample. Such a focal spot size is mandatory to achieve ultimate resolution and to guarantee best performance of the vacuum-ultraviolet (VUV) off-axis parabolic double-monochromator Raman spectrometer permanently installed at the PG1 beamline as an experimental end-station. The vertical beam size on the sample of the Raman spectrometer, which operates without entrance slit, defines and limits the energy resolution of the instrument which has an unprecedented design value of 2 meV for photon energies below 70 eV and about 15 meV for higher energies up to 200 eV. In order to reach the designed focal spot size of 4 µm FWHM (vertically) and to hold the highest spectrometer resolution, special fully motorized in-vacuum manipulators for the KB mirror holders have been developed and the optics have been aligned employing wavefront-sensing techniques as well as ablative imprints analysis. Lastly, aberrations like astigmatism were minimized. In this article the design and layout of the KB mirror manipulators, the alignment procedure as well as microfocus optimization results are presented.

43 PARTICLE ACCELERATORS↗

Ronchi shearing interferometry for wavefronts with circular symmetry

Ronchi testing of a focused electromagnetic wave has in the last few years been used extensively at X-ray free-electron laser (FEL) facilities to qualitatively evaluate the wavefront of the beam. It is a quick and straightforward test, is easy to interpret on the fly, and can be used to align phase plates that correct the focus of aberrated beams. In general, a single Ronchigram is not sufficient to gain complete quantitative knowledge of the wavefront. However the compound refractive lenses that are commonly used at X-ray FELs exhibit a strong circular symmetry in their aberration, and this can be exploited. Furthermore, a simple algorithm that uses a single recorded Ronchigram to recover the full wavefront of a nano-focused beam, assuming circular symmetry, is presented, and applied to experimental measurements at the Matter in Extreme Conditions instrument at the Linac Coherent Light Source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards Full Field-of-View Fourier Ptychography for Extreme Ultraviolet Microscope

We evaluate various Fourier ptychographic microscopy (FPM) reconstruction algorithms using both simulated and experimental data acquired from an Extreme Ultraviolet (EUV, 13.5 nm wavelength) microscope. We specifically focus on the algorithms' ability to robustly address field-dependent aberrations, which enables increased spatial resolution and quantitative phase imaging across an expanded field of view. We systematically compare the algorithms' performance under aberrations for a single zoneplate imaging system, utilizing Fourier Ring Correlation (FRC) as a systematic metric for assessing reconstruction quality. Furthermore, we explore the impact of systematic errors on the reconstruction of experimental data, aiming to increase the effective field of view by 25-fold, from the nominal 5x5 um2 diffraction-limited area. Additionally, our evaluation incorporates innovative FPM-adjacent methodologies, including the Angular Ptychographic Imaging with Closed-form method (APIC), for reconstructing EUV images.

Gu, Chaoying↗

Measurement of EUV lithography pupil amplitude and phase variation via image-based methodology

Here, an approach to image-based EUV aberration metrology using binary mask targets and iterative model-based solutions to extract both the amplitude and phase components of the aberrated pupil function is presented. The approach is enabled through previously developed modeling, fitting, and extraction algorithms. We seek to examine the behavior of pupil amplitude variation in real-optical systems. Optimized target images were captured under several conditions to fit the resulting pupil responses. Both the amplitude and phase components of the pupil function were extracted from a zone-plate-based EUV mask microscope. The pupil amplitude variation was expanded in three different bases: Zernike polynomials, Legendre polynomials, and Hermite polynomials. It was found that the Zernike polynomials describe pupil amplitude variation most effectively of the three.

60 APPLIED LIFE SCIENCES↗

An engineered design of a diffractive mask for high precision astrometry [Modeling a diffractive mask that calibrates optical distortions]

AutoCAD, Zemax Optic Studio 15, and Interactive Data Language (IDL) with the Proper Library are used to computationally model and test a diffractive mask (DiM) suitable for use in the Gemini Multi-Conjugate Adaptive Optics System (GeMS) on the Gemini South Telescope. Systematic errors in telescope imagery are produced when the light travels through the adaptive optics system of the telescope. DiM is a transparent, flat optic with a pattern of miniscule dots lithographically applied to it. It is added ahead of the adaptive optics system in the telescope in order to produce diffraction spots that will encode systematic errors in the optics after it. Once these errors are encoded, they can be corrected for. DiM will allow for more accurate measurements in astrometry and thus improve exoplanet detection. Furthermore, the mechanics and physical attributes of the DiM are modeled in AutoCAD. Zemax models the ray propagation of point sources of light through the telescope. IDL and Proper simulate the wavefront and image results of the telescope. Aberrations are added to the Zemax and IDL models to test how the diffraction spots from the DiM change in the final images. Based on the Zemax and IDL results, the diffraction spots are able to encode the systematic aberrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A computer aided treatment event recognition system in radiation therapy

Purpose: To develop an automated system to safeguard radiation therapy treatments by analyzing electronic treatment records and reporting treatment events. Methods: CATERS (Computer Aided Treatment Event Recognition System) was developed to detect treatment events by retrieving and analyzing electronic treatment records. CATERS is designed to make the treatment monitoring process more efficient by automating the search of the electronic record for possible deviations from physician's intention, such as logical inconsistencies as well as aberrant treatment parameters (e.g., beam energy, dose, table position, prescription change, treatment overrides, etc). Over a 5 month period (July 2012–November 2012), physicists were assisted by the CATERS software in conducting normal weekly chart checks with the aims of (a) determining the relative frequency of particular events in the authors’ clinic and (b) incorporating these checks into the CATERS. During this study period, 491 patients were treated at the University of Iowa Hospitals and Clinics for a total of 7692 fractions. Results: All treatment records from the 5 month analysis period were evaluated using all the checks incorporated into CATERS after the training period. About 553 events were detected as being exceptions, although none of them had significant dosimetric impact on patient treatments. These events included every known event type that was discovered during the trial period. A frequency analysis of the events showed that the top three types of detected events were couch position override (3.2%), extra cone beam imaging (1.85%), and significant couch position deviation (1.31%). The significant couch deviation is defined as the number of treatments where couch vertical exceeded two times standard deviation of all couch verticals, or couch lateral/longitudinal exceeded three times standard deviation of all couch laterals and longitudinals. On average, the application takes about 1 s per patient when executed on either a desktop computer or a mobile device. Conclusions: CATERS offers an effective tool to detect and report treatment events. Automation and rapid processing enables electronic record interrogation daily, alerting the medical physicist of deviations potentially days prior to performing weekly check. The output of CATERS could also be utilized as an important input to failure mode and effects analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Registration of human skull computed tomography data to an ultrasound treatment space using a sparse high frequency ultrasound hemispherical array

Purpose: Transcranial focused ultrasound (FUS) shows great promise for a range of therapeutic applications in the brain. Current clinical investigations rely on the use of magnetic resonance imaging (MRI) to monitor treatments and for the registration of preoperative computed tomography (CT)-data to the MR images at the time of treatment to correct the sound aberrations caused by the skull. For some applications, MRI is not an appropriate choice for therapy monitoring and its cost may limit the accessibility of these treatments. An alternative approach, using high frequency ultrasound measurements to localize the skull surface and register CT data to the ultrasound treatment space, for the purposes of skull-related phase aberration correction and treatment targeting, has been developed. Methods: A prototype high frequency, hemispherical sparse array was fabricated. Pulse-echo measurements of the surface of five ex vivo human skulls were made, and the CT datasets of each skull were obtained. The acoustic data were used to rigidly register the CT-derived skull surface to the treatment space. The ultrasound-based registrations of the CT datasets were compared to the gold-standard landmark-based registrations. Results: The results show on an average sub-millimeter (0.9 ± 0.2 mm) displacement and subdegree (0.8° ± 0.4°) rotation registration errors. Numerical simulations predict that registration errors on this scale will result in a mean targeting error of 1.0 ± 0.2 mm and reduction in focal pressure of 1.0% ± 0.6% when targeting a midbrain structure (e.g., hippocampus) using a commercially available low-frequency brain prototype device (InSightec, 230 kHz brain system). Conclusions: If combined with ultrasound-based treatment monitoring techniques, this registration method could allow for the development of a low-cost transcranial FUS treatment platform to make this technology more widely available.

60 APPLIED LIFE SCIENCES↗

Electron ptychography achieves atomic-resolution limits set by lattice vibrations

Transmission electron microscopes use electrons with wavelengths of a few picometers, potentially capable of imaging individual atoms in solids at a resolution ultimately set by the intrinsic size of an atom. However, owing to lens aberrations and multiple scattering of electrons in the sample, the image resolution is reduced by a factor of 3 to 10. By inversely solving the multiple scattering problem and overcoming the electron-probe aberrations using electron ptychography, we demonstrate an instrumental blurring of less than 20 picometers and a linear phase response in thick samples. The measured widths of atomic columns are limited by thermal fluctuations of the atoms. As a result, our method is also capable of locating embedded atomic dopant atoms in all three dimensions with subnanometer precision from only a single projection measurement.

42 ENGINEERING↗

Adaptive optics for optical microscopy [Invited]

Optical microscopy is widely used to visualize fine structures. When applied to bioimaging, its performance is often degraded by sample-induced aberrations. In recent years, adaptive optics (AO), originally developed to correct for atmosphere-associated aberrations, has been applied to a wide range of microscopy modalities, enabling high- or super-resolution imaging of biological structure and function in complex tissues. Here, we review classic and recently developed AO techniques and their applications in optical microscopy.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive optical third-harmonic generation microscopy for in vivo imaging of tissues

Third-harmonic generation microscopy is a powerful label-free nonlinear imaging technique, providing essential information about structural characteristics of cells and tissues without requiring external labelling agents. In this work, we integrated a recently developed compact adaptive optics module into a third-harmonic generation microscope, to measure and correct for optical aberrations in complex tissues. Taking advantage of the high sensitivity of the third-harmonic generation process to material interfaces and thin membranes, along with the 1,300-nm excitation wavelength used here, our adaptive optical third-harmonic generation microscope enabled high-resolution in vivo imaging within highly scattering biological model systems. Examples include imaging of myelinated axons and vascular structures within the mouse spinal cord and deep cortical layers of the mouse brain, along with imaging of key anatomical features in the roots of the model plant Brachypodium distachyon. In all instances, aberration correction led to enhancements in image quality.

60 APPLIED LIFE SCIENCES↗