Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Resilience of High-Efficiency CdSeTe:As and CdSeTe:Cu Solar Cells to Proton Irradiation

Power generation in space is currently dominated by expensive III-V multi-junction photovoltaic (PV) devices and cheap crystalline silicon (c-Si) PV devices. Both of these technologies degrade rapidly in proton-radiation-rich space environments, such as the Van Allen belt. The present study of cadmium selenide telluride- (CdSeTe-) based PV devices exposed to 150-to-1500 keV proton irradiation with fluences up to 9 x 1013 cm-2 reveal a more radiation-hard alternative to III-V and c-Si PV technologies. We report on measurement and analysis of current density vs voltage (JV), external quantum efficiency (EQE), external radiative efficiency, and capacitance vs voltage (CV) characteristics. JV characteristics of As-doped CdSeTe devices show 80% remaining power conversion efficiency (PCE) relative to unexposed controls when exposed to 650 keV protons at a fluence of 1012 cm-2. Under these same irradiation conditions, Cu-doped CdSeTe devices demonstrate an even better 95% PCE retention compared with unirradiated control devices. Evidence of radiation-induced absorber p-type doping compensation is observed in the glass-side EQE at 0 V and CV characteristics of most of the irradiated CdSeTe:As devices, but clear compensation is evident only for the most heavily irradiated CdSeTe:Cu devices. Elevated blue-green photocurrent in the film-side 0 V EQE suggests a buried junction in the most heavily irradiated CdSeTe:As devices. Although CdSeTe:Cu devices are the more resilient of the CdSeTe structures, both CdSeTe-based technologies are radiation-hard when compared to c-Si and III-V multi-junction PV.

14 SOLAR ENERGY↗

When x-rays alter the course of your experiments

The continuing increase in the brilliance of synchrotron radiation beamlines allows for many new and exciting experiments that were impossible before the present generation of synchrotron radiation sources came on line. However, the exposure to such intense beams also tests the limits of what samples can endure. Whilst the effects of radiation induced damage in a static experiment often can easily be recognized by changes in the diffraction or spectroscopy curves, the influence of radiation on chemical or physical processes, where one expects curves to change, is less often recognized and can be misinterpreted as a 'real' result instead of as a 'radiation influenced result'. This is especially a concern in time-resolved materials science experiments using techniques as powder diffraction, small angle scattering and x-ray absorption spectroscopy. In this work, the effects of radiation (5–50 keV) on some time-resolved processes in different types of materials and in different physical states are discussed. We show that such effects are not limited to soft matter and biology but rather can be found across the whole spectrum of materials research, over a large range of radiation doses and is not limited to very high brilliance beamlines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

Development of a broadband hard x-ray radiography platform for pulsed-power experiments

In this article, we develop and demonstrate a broadband hard x-ray radiography platform at the Zebra Pulsed Power Laboratory that integrates point-projection radiography, bremsstrahlung measurements, and hard x-ray pinhole imaging, designed to diagnose current-driven, cylindrically compressed matter. Initial laser-pulsed-power coupled experiments revealed that intense background radiation generated during 1 MA Zebra current shots overwhelmed laser-produced hard x-rays, obscuring radiographic images. Using combined spectral and spatial diagnostics, we identify energetic electrons accelerated by return currents as the dominant source of background hard x-rays, with electron energies inferred to be 3–4 MeV based on Monte Carlo simulations, and demonstrate mitigation through modifications to the radiation shielding and return-current configuration. The diagnostic platform was validated using a wire-pinch hard x-ray source, allowing radiographs of static 1-mm-diameter aluminum wires to be obtained while simultaneously measuring x-ray source spectra and spatial emission distributions within a single shot. Measured wire transmission profiles were quantitatively reconstructed using radiation transport simulations that incorporate an experimentally inferred two-temperature exponential x-ray spectrum from bremsstrahlung signal analysis and spatially distributed emission sources identified by pinhole imaging. Agreement between measured and simulated transmission profiles demonstrates the validity of the radiographic and x-ray source characterization approach, establishing this diagnostic platform as a promising tool for diagnosing magnetically driven, high-density plasmas relevant to warm dense matter and inertial fusion energy research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fuel–shell mix and yield degradation in kinetic shock-driven inertial confinement fusion implosions

Fuel–shell mix in kinetic plasma conditions is probed using nuclear and x-ray self-emission in shock-driven, D 3 He-gas-filled inertial confinement fusion implosions. As initial gas fill density decreases, measured nuclear yields and ion temperatures are lower than expected as compared to radiation-hydrodynamic simulations. Spatially and temporally resolved x-ray emissions indicate significant mixing at the fuel–shell interface in implosions with low initial gas fill density. In conclusion, this observed fuel–shell mix introduces a substantial amount of shell ions into the center of the implosion prior to and during shock flash and is the key mechanism needed in the kinetic-ion simulations to match experimental nuclear yields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Terawatt attosecond x-ray source driven by a plasma accelerator

Plasma accelerators can generate ultra-high-brightness electron beams that open the door to light sources with a smaller physical footprint and properties un-achievable with conventional accelerator technology. In this paper, we show that electron beams from Plasma WakeField Accelerators can generate few-cycle coherent tunable soft x-ray pulses with TW peak power and a duration of tens of attoseconds, an order of magnitude more powerful, shorter, and with better stability than state-of-the-art X-ray Free Electron Lasers (XFELs). Such a light source would significantly enhance the ability to experimentally investigate electron dynamics on ultrafast timescales, having a broad-ranging impact across multiple scientific fields. Rather than starting from noise as in typical XFELs, the x-ray emission in this approach is driven by coherent radiation from a pre-bunched, high peak current electron beam of attosecond duration. This relaxes the restrictive tolerances that have hindered progress toward utilizing plasma accelerators as coherent x-ray drivers thus far, presenting a new paradigm for advanced accelerator light source applications.

43 PARTICLE ACCELERATORS↗

Environmental cell for in situ X-ray synchrotron micro-CT imaging with simultaneous acoustic measurements

Synchrotron radiation provides the necessary spatial and temporal resolution for non-invasive operando studies of dynamic processes under complex environmental conditions. Here a new environmental cell for simultaneous in situ dynamic X-ray imaging and measuring acoustic properties of geological samples is presented. The primary purpose of this cell is to study gas-hydrate formation in porous geo-materials and its influence on their acoustic properties. The cell is designed for cylindrical samples of 9 mm in diameter, confining and pore pressures up to 12 MPa, and temperatures from –20°C to room temperature. The cell is portable and can be easily assembled and operated at different X-ray sources. This cell enables a wide range of experiments studying physical/chemical processes in the Earth subsurface that change the mechanical properties of rocks (geochemical reactions, phase transitions, etc.).

47 OTHER INSTRUMENTATION↗

MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography

Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterisation of Specimens from a Former Soviet Thorium Processing Facility to Support Site Remediation

The former Prydniprovski Chemical Plant (PChP) is a large ex-soviet nuclear materials processing site of roughly 260 hectares, located in central Ukraine. PcHP was in operation between 1948 and 1991 for the purposes of processing uranium and thorium ore into ore concentrate. During its operational lifetime, tens of millions of tonnes of radioactive waste was generated on the site. A consequence of these activities, coupled with the mismanagement of the resulting radioactive materials and by-products, is that approximately 45% of the southern part of the site has become radioactively contaminated. This area comprises some 100-200 buildings and structures, many of which are in a state of disrepair and dereliction. Around 20 of these buildings are heavily radioactively contaminated, with radiation levels from a few μSv/hr to a maximum of 4 mSv/hr reported. The European Commission is currently working with the Ukraine Ministry of Energy and Coal Use and the Nuclear Regulator to improve radiological safety and security at the site. In order for these remediation works to proceed, the site management needs to characterise the radioactive materials that are held there. As part of this activity, the team from the University of Bristol have undertaken a survey of one of the most heavily contaminated buildings, collecting a selection of in situ material samples. A suite of complimentary materials characterisation techniques (e.g. X-ray Fluorescence, Raman Spectroscopy, etc) have been deployed in order to determine the radionuclides and composition of the compounds present. Characterisation of these samples will allow the operators of the chemical plant to go forward with remediation works within the building.

07 ISOTOPE AND RADIATION SOURCES↗

GRB 110213A: A Study of Afterglow Electromagnetic Cascade Radiation

We obtained well-sampled optical photometry of GRB 110213A, including Swift/UVOT and XRT. Combining our data from those of other ground-based telescopes, we present 15 optical multicolor light curves showing similar shapes with two peaks. In contrast, in the X-ray band, only a single peak is observed between the two optical peaks. Temporal and spectral analysis of GRB 110213A shows that the X-rays differ from the optical for Phases I–III (before the second peak of the optical band at ~5.6 ks). Moreover, they have the same spectral behavior at late times (Phases IV–VI). These data indicate that the optical and X-ray emission are dominated by different components. The synchrotron-supported pair cascade emission is included in the standard external forward-shock model, which is dominated by synchrotron radiation and synchrotron self-Compton (SSC). We find that the optical bands of GRB 110213A are dominated by the cascade emission from synchrotron radiation + SSC at the early stage, while the primary synchrotron + SSC radiation dominates the X-ray band. At late stages, both the X-ray and optical bands are dominated by emission from primary synchrotron + SSC radiation. The cascade component can reasonably explain the first optical peak. In contrast, the primary synchrotron + SSC emission mainly contributes to the second peak.

79 ASTRONOMY AND ASTROPHYSICS↗

High-contrast, convergent x-ray imaging with laser-Compton sources

Techniques are provided for the production of high-contrast, x-ray and/or gamma-ray radiographic images. The images have minimal contributions from object-dependent background radiation. The invention utilizes the low divergence, quasi-monoenergetic, x-ray or gamma-ray output from a laser-Compton source in combination with x-ray optical technologies to produce a converging x-ray or gamma-ray beam with which to produce a high-contrast, shadowgraph of a specific object. The object to be imaged is placed within the path of the converging beam between the x-ray optical assembly and the focus of the x-ray beam produced by that assembly. The beam is then passed through an optically thick pinhole located at the focus of the beam. Downstream of the pinhole, the inverted shadowgraph of the object is then recorded by an appropriate 2D detector array.

Barty, Christopher P. J.↗

A Comparison of Cs-137 γ Rays and 320-kV X-Rays in a Mouse Bone Marrow Transplantation Model

US homeland security concerns regarding the potential misuse of some radiation sources used in radiobiological research, for example, cesium-137 ( 137 Cs), have resulted in recommendations by the National Research Council to conduct studies into replacing these sources with suitable X-ray instruments. The objective of this research is to compare the effectiveness of an X-RAD 320 irradiator (PXINC 2010) with a 137 Cs irradiator (Gammacell-1000 Unit) using an established bone marrow chimeric model. Using measured radiation doses for each instrument, we characterized the dose–response relationships for bone marrow and splenocyte ablation, using a cytotoxicity-hazard model. Our results show that the X-RAD 320 photon energy spectrum was suitable for ablating bone marrow at the 3 exposure levels used, similar to that of 137 Cs photons. However, the 320-kV X-rays were not as effective as the much higher energy γ rays at depleting mouse splenocytes. Furthermore, the 3 X-ray levels used were less effective than the higher energy γ rays in allowing the successful engraftment of donor bone marrow, potentially as a result of the incomplete depletion of the spleen cells. More defined studies are warranted for determining whether bone marrow transplantation in mice can be successfully achieved using 320-kV X-rays. A higher X-ray dose then used is likely needed for transplantation success.

320-kV X-rays↗

X-ray free-electron laser wavefront sensing using the fractional Talbot effect

Wavefront sensing at X-ray free-electron lasers is important for quantitatively understanding the fundamental properties of the laser, for aligning X-ray instruments and for conducting scientific experimental analysis. A fractional Talbot wavefront sensor has been developed. This wavefront sensor enables measurements over a wide range of energies, as is common on X-ray instruments, with simplified mechanical requirements and is compatible with the high average power pulses expected in upcoming X-ray free-electron laser upgrades. Single-shot measurements were performed at 500 eV, 1000 eV and 1500 eV at the Linac Coherent Light Source. These measurements were applied to study both mirror alignment and the effects of undulator tapering schemes on source properties. The beamline focal plane position was tracked to an uncertainty of 0.12 mm, and the source location for various undulator tapering schemes to an uncertainty of 1m, demonstrating excellent sensitivity. These findings pave the way to use the fractional Talbot wavefront sensor as a routine, robust and sensitive tool at X-ray free-electron lasers as well as other high-brightness X-ray sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Human perception of ionizing radiation

Here, in this work, we address the question of whether humans can perceive ionizing radiation. We conducted a thorough review of the clinical and experimental literature related to ionizing radiation, with a focus on its acute effects. Specifically, we examined the three domains of X-ray perception found in animals (abdominal, olfactory, and retinal), which led us to instances of ionizing radiation-induced hearing and taste sensory phenomena in humans thus suggesting that humans can perceive X-rays across various sensory modalities via multiple mechanisms. We also analyzed literature to understand the mechanisms associated with reported symptoms, this led us to the concept of radiomodulation, an understudied modulatory effect of sub-ablative ionizing radiation doses on neurons. Based on this review of the literature we propose the hypothesis that a significant radiomodulation mechanism is the formation of reactive oxygen species from radiolysis which activates immune and sensory signal transduction mechanisms specifically related to the redox activity in TRP and K+ channels. Additionally, we find evidence to support the previous claims of perception stemming from Cherenkov radiation and ozone production which are perceived using canonical sensory modalities. Finally, for we provide a concise summary of the applications of ionizing radiation in clinical imaging and therapy, as well as prospects for future developments of radiation technologies for biomedical and fundamental research.

Ionizing radiation↗

A combined MeV-neutron and x-ray source for the National Ignition Facility

We report that in support of future radiation-effects testing, a combined environment source has been developed for the National Ignition Facility (NIF), utilizing both NIF’s long-pulse beams, and the Advanced Radiographic Capability (ARC) short pulse lasers. First, ARC was used to illuminate a gold foil at high-intensity, generating a significant x-ray signal > 1 MeV. This was followed by NIF 10 ns later to implode an exploding pusher target filled with fusionable gas for neutron generation. The neutron and x-ray bursts were incident onto a retrievable, close-standoff diagnostic snout. With separate control over both neutron and x-ray emission, the platform allows for tailored photon and neutron fluences and timing on a recoverable test sample. The platform exceeded its initial fluence goals, demonstrating a neutron fluence of 2.3 ×10 13 n/cm 2 and an x-ray dose of 7 krad.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence of Morphological Change in Sulfur Cathodes upon Irradiation by Synchrotron X-rays

While the development of lithium–sulfur battery cathodes has benefited substantially from the use of in situ and ex situ X-ray absorption studies, the degree of undesired influence from synchrotron radiation has not been studied. In this study, we present evidence of severe beam damage on sulfur cathodes under irradiation by synchrotron X-rays. Specifically, X-ray fluorescence mapping with relatively low dosage was conducted to observe the morphological changes after conducting X-ray absorption spectroscopy (XAS). Under open-circuit conditions, the morphology of the sulfur spontaneously changes and tends to migrate out of the region of XAS sampling. Our work indicates that effort should be placed in first obtaining a no-change/stable open-circuit baseline when attempting to conduct in operando studies of lithium–sulfur batteries using synchrotron radiation with an energy of <7.7 keV and a flux of >6 × 10 12 photons s –1 .

25 ENERGY STORAGE↗

High gas throughput SOLPS-ITER simulations extending the ITER database to strong detachment

Abstract SOLPS-ITER simulations performed for Q DT = 10, P SOL = 100 MW burning plasmas on ITER extend the existing database to high values of separatrix averaged neon impurity concentration (⟨ c Ne ⟩ ≈ 6%) and divertor neutral pressure (⟨ p div ⟩ > 25 Pa) in order to determine the heat flux mitigation capability of these scenarios and whether strongly detached states are accessible. In the existing database of ITER simulations, the level of detachment was limited to cases where the integral ion flux to the outer target was greater than 80% of the value at rollover, with the impurity radiation localized near the target. With the possibility of narrow heat flux channels and increased deposited power due to tile shaping, it is important to explore operation at a higher degree of detachment. Two series of simulations were explored to extend the database of SOLPS simulations. By increasing the deuterium and neon puff rates proportionally, the peak divertor energy flux ( q ⊥,max ) is decreased from 5 to 3 MW m −2 while ⟨ p div ⟩ increased from 11 to 27 Pa. By increasing only the neon puff, q ⊥, max can be reduced to <1MW m −2 while ⟨ p div ⟩ is maintained at ∼ 11 Pa. As the neon puff level is increased, the position of the impurity radiation peak is shifted towards the X-point. At the highest neon puff levels with steady-state solutions, the electron temperature is reduced below 1 eV across 50 cm of each divertor target. The new cases extend previously observed tight relationships in power and momentum loss factors to low electron temperature improving their utility for highly detached regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Manufacturability-based optical design optimization for advanced Kirkpatrick–Baez X-ray focusing mirrors

The advanced Kirkpatrick–Baez (AKB) mirror setup is an effective and compelling solution to provide stable X-ray nano-focusing for synchrotron radiation or free-electron laser beamlines. We propose an AKB mirror design optimization approach to mitigate the difficulties associated with mirror fabrication by minimizing the total slope ranges of the four curved mirrors while achieving the expected focusing performance. In the optimization, we have considered geometry constraints to ensure the beam acceptance with the required clear aperture, the diffraction-limited focal size with the adequate numerical aperture, and the desired mirror gaps for adjustment and the necessary working distance for the sample stage. Additionally, practical constraints linked to mirror metrology and fabrication, such as mirror length limits and curvature uncertainty in measurement, are taken into account. Furthermore, progressive objective optimization eliminates the need for any initial guess, fully automating the AKB optimization process. This approach facilitates the development of an elegant Wolter-I or Wolter-III type AKB design solution that satisfies these multiple constraints. In cases where constraints cannot be simultaneously satisfied, the optimization results provide valuable insights into areas where trade-offs need to be considered. Simulations with ray tracing and wavefront propagation validate the optimized AKB design showing high tolerance to the beam incident angle.

36 MATERIALS SCIENCE↗