Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Building America Case Study: Side-by-Side Testing of Water Heating Systems: Results from 2013-2014 Evaluation Final Report, Cocoa, FL

The Florida Solar Energy Center (FSEC) has completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). This report contains a summary of research activities regarding the evaluation of two residential electric heat pump water heaters (HPWHs), a solar thermal system utilizing a polymer glazed absorber and a high efficiency natural gas system.

30 DIRECT ENERGY CONVERSION↗

Corrosion consequences of microfouling in water reclamation systems

This paper examines the potential fouling and corrosion problems associated with microbial film formation throughout the water reclamation system (WRS) designed for the Space Station Freedom. It is shown that the use of advanced metal sputtering techiques combined with image analysis and FTIR spectroscopy will present realistic solutions for investigating the formation and function of biofilm on different alloys, the subsequent corrosion, and the efficiency of different treatments. These techniques, used in combination with electrochemical measurements of corrosion, will provide a powerful approach to examinations of materials considered for use in the WRS.

Ford, Tim↗

Method Development for In Situ Microbiome Profiling of the Water Recovery System’s Wastewater Tank Onboard the International Space Station

A distinctive microbial community has inhabited the International Space Station (ISS) Water Recovery System (WRS) for over 14 years and has experienced the stressors associated with the microgravity environment. The WRS generates potable water for the crew from urine distillate, humidity condensate, Sabatier product water, and the occasional off-loading of ground-supplied water (1). The reservoir for these products, the wastewater tank, does not have a means of microbial control. Current in situ microbial monitoring of the WRS is limited to quarterly culture-based assessments of the potable water product using a microbial capture device and coliform detection bag. Additional analysis of the wastewater and condensate sources are collected into Teflon bags for analysis following return to the ground. The time between sample collection and the return to Earth, as well as the lack of preservation, results in a skewed depiction of the microbiome. Routinely observed from these returned wastewater samples are high counts (105 – 106 colony forming units per mL) and two prevailing genera, Ralstonia and Cupriavidus, as well as a high abundance of unidentified organisms (Table 1). The wastewater tank likely contains a more diverse microbiome, as a higher diversity of bacteria and fungi has been noted upstream and downstream of the tank.

Sarah Stahl-Rommel↗

Biodeterioration of materials in water reclamation systems

The chemicals produced by the microbial processes involved in the 'biofilms' which form on the surfaces of manned spacecraft water reclamation systems encompass both metals and organic poisons; both are potential hazards to astronaut health and the growth of the plants envisioned for closed-cycle life support systems. Image analysis is here shown to be a very useful technique for the study of biofilm formation on candidate water-processor materials for Space Station Freedom. The biodeterioration of materials exposed to biofilms can be swiftly evaluated by means of electrochemical impedance spectroscopy.

Ford, Tim↗

Evaluating Domestic Hot Water Distribution System Options With Validated Analysis Models

A developing body of work is forming that collects data on domestic hot water consumption, water use behaviors, and energy efficiency of various distribution systems. A full distribution system developed in TRNSYS has been validated using field monitoring data and then exercised in a number of climates to understand climate impact on performance. This study builds upon previous analysis modelling work to evaluate differing distribution systems and the sensitivities of water heating energy and water use efficiency to variations of climate, load, distribution type, insulation and compact plumbing practices. Overall 124 different TRNSYS models were simulated. Of the configurations evaluated, distribution losses account for 13-29% of the total water heating energy use and water use efficiency ranges from 11-22%. The base case, an uninsulated trunk and branch system sees the most improvement in energy consumption by insulating and locating the water heater central to all fixtures. Demand recirculation systems are not projected to provide significant energy savings and in some cases increase energy consumption. Water use is most efficient with demand recirculation systems, followed by the insulated trunk and branch system with a central water heater. Compact plumbing practices and insulation have the most impact on energy consumption (2-6% for insulation and 3-4% per 10 gallons of enclosed volume reduced). The results of this work are useful in informing future development of water heating best practices guides as well as more accurate (and simulation time efficient) distribution models for annual whole house simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology transfer potential of an automated water monitoring system

The nature and characteristics of the potential economic need (markets) for a highly integrated water quality monitoring system were investigated. The technological, institutional and marketing factors that would influence the transfer and adoption of an automated system were studied for application to public and private water supply, public and private wastewater treatment and environmental monitoring of rivers and lakes.

Jamieson, W. M.↗

Towards an Indian Land Data Assimilation System (ILDAS): A Coupled Hydrologic-Hydraulic System for Water Balance Assessments

Effective management of water resources requires reliable estimates of land surface states and fluxes, including water balance components. But most land surface models run in uncoupled mode and do not produce river discharge at catchment scales to be useful for water resources management applications. Such integrated systems are also rare over India where hydrometeorological extremes have wreaked havoc on the economy and people. So, an Indian Land Data Assimilation System (ILDAS) with a coupled land surface and a hydrodynamic model has been developed and driven by multiple meteorological forcings (0.1°, daily) to estimate land surface states, channel discharge, and floodplain inundation. ILDAS benefits from an integrated framework as well as the largest suite of observation records collected over India and has been used to produce a reanalysis product for 1981–2021 using four forcing datasets, namely, Modern-Era Retrospective Analysis for Research and Applications, Version 2 (MERRA-2), Climate Hazards Group InfraRed Precipitation with Station data (CHIRPS), ECMWF’s ERA-5, and Indian Meteorological Department (IMD) gridded precipitation. We assessed the uncertainty and bias in these precipitation datasets and validated all major components of the terrestrial water balance, i.e., surface runoff, soil moisture, terrestrial water storage anomalies, evapotranspiration, and streamflow, against a combination of satellite and in situ observation datasets. Our assessment shows that ILDAS can represent the hydrological processes reasonably well over the Indian landmass with IMD precipitation showing the best relative performance. Evaluation against ESA-CCI soil moisture shows that MERRA-2 based estimates outperform the others, whereas ERA-5 performs best in simulating evapotranspiration when evaluated against MODIS ET. Evaluations against observed records show that CHIRPS-based estimates have the highest performance in reconstructing surface runoff and streamflow. Once operational, this system will be useful for supporting transboundary water management decision making in the region.

Indian Land Data Assimilation System (ILDAS)↗

Monitoring Based Commissioning: Step-by-Step Approach to Implementation in Chiller Plants

Chilled water systems consume a significant portion of the energy in manufacturing, and inefficient operation could significantly influence utility bills and the environmental footprint of a facility. One way to ensure long-term energy-efficient plant operation is to ensure that chilled water system equipment, such as chillers, cooling towers, and pumps, are running at their best. Periodic operational assessments help to meet efficiency objectives for cooling plants. However, occasional set point and operational changes resulting from short-term fluctuations cause the plant operation to deviate from optimal. These changes accumulate over time, and operational efficiency deteriorates. Significant energy efficiency improvement potential in chilled water systems can be achieved by operational changes alone. Recent developments in information technology and the industrial internet of things data processing ability have overcome traditional problems and given rise to a new paradigm: monitoring-based commissioning (MBCx). Commissioning platforms and fault detection and diagnostics capabilities have evolved over time and presented more sophisticated abilities to efficiently control process cooling plants. The typical architectures of the MBCx process and a detailed approach to implement the process for chilled water systems are presented. A case study highlighting the energy-and cost-savings potential of MBCx systems is also presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-situ Raman Instrumentation and Measurements in Supercritical Water Oxidation Systems

Due to the advent of recent advances in reactor designs and operational procedures, renewed attention has been given to a host of supercritical water oxidation (SCWO) technology applications. This includes resource recovery, water reclamation, and solid waste destruction. SCWO is often recognized as a “green technology” because of its ability to extract useful energy while producing benign products from environmentally challenging waste streams (e.g., wet organic wastes, pharmaceutical wastes, military wastes). The present work was motivated by NASA’s interests in solid waste management and water recovery for long-duration space missions. To that end, the main focus of this paper is to present work on characterizing the behavior of supercritical water oxidation systems utilizing state of the art laser Raman spectroscopy. The main benefit of Raman diagnostics is its ability to identify chemical composition and to measure concentrations of the compounds involved in the reaction. Two separate Raman systems for SCWO measurements that have been developed for this study will be described. The first system is a 2-D traversing system useful for making in-situ measurements in conditions where spatial gradients of species and temperature are important and has been successfully utilized in making species (ethanol, oxygen, water, nitrogen and carbon dioxide) concentrations and temperature measurements in ethanol hydrothermal jet flames. The second system is a packaged modular Raman probe unit for portable deployment to different reactors and is more suitable for relatively homogeneous systems such as a batch reactor. The design, development, and examples of obtained results from both systems will be presented for various reactant streams. Reaction rate and fuel conversion estimates from chemistry models will also be presented.

supercritical water oxidation↗

Detectability-Based Resilience of Water Distribution System Using Failure Finger Print

This study introduces a detectability-based sensor localizing framework to enhance the resilience of water distribution systems. The framework includes leakage detection and resilience assessment. A feasibility test and a sensitivity analysis prove the framework successfully can detect correct leakage location. The resilience measure was found to increase for higher detectability and shorter identification time. The sensor location is constrained by minimizing the number of sensors and maximizing the detectability and resilience. Results show that two sensors will efficiently detect burst leakage in the studied network. Detectability varies from 71.3% to 99.4% depending on the location of two sensors, while resilience value was reduced by 7.5%. Estimated water loss due to detection time lag are almost 111 ML, which may lead to significant direct and indirect economic loss.

Lee, Seungyub↗

Thermal Neutralizer of Industrial Wastewaters for Power-, Heat-, and Water-Supply Systems of Oil and Gas Enterprises

A design for a neutralizer of industrial wastewaters that complemented power-, heat-, and water-supply systems of oil and gas enterprises was proposed. A scheme of a neutralizer with thermal destruction of effluents and gaseous and liquid combustible wastes and container disposal of the resulting dry residue was presented. Technical solutions that made it possible to achieve the lowest specific fuel consumption among known designs and to increase the energy efficiency and environmental safety of oil and gas enterprises were described.

42 ENGINEERING↗

Control and prevention measures for legionellosis in hospitals: A cross-sectional survey in Italy

Highlights: • Legionellosis risk is high in Italian hospitals with many hospitalizations. • Legionella contamination in the water system was assessed in 97% of hospitals. • Risk assessment was performed in 73% of hospitals but only 53% had a dedicated team. • Measures to reduce legionellosis risk were adopted in 93.3% of hospitals. • Training courses on Legionnaires’ disease were planned in 36.5% of hospitals. Risk assessment, environmental monitoring, and the disinfection of water systems are the key elements in preventing legionellosis risk. The Italian Study Group of Hospital Hygiene of the Italian Society of Hygiene, Preventive Medicine, and Public Health and the Italian Multidisciplinary Society for the Prevention of Health Care-Associated Infections carried out a national cross-sectional survey to investigate the measures taken to prevent and control legionellosis in Italian hospitals. A multiple-choice questionnaire was developed, comprising 71 questions regarding hospital location, general characteristics, clinical and environmental surveillance, and control and preventive measures for legionellosis in 2015. Overall, 739 hospitals were enrolled from February to June 2017, and 178 anonymous questionnaires were correctly completed and evaluated (response rate: 24.1%). The survey was conducted using the SurveyMonkey® platform, and the data were analyzed using Stata 12 software. Of the participating hospitals, 63.2% reported at least one case of legionellosis, of which 28.2% were of proven nosocomial origin. The highest case numbers were reported in the Northern Italy, in hospitals with a pavilion structure or cooling towers, and in hospitals with higher numbers of beds, wards and operating theaters. Laboratory diagnosis was performed using urinary antigen testing alone (31.9%), both urinary antigen testing and single antibody titer (17.8%), or with seroconversion also added (21.5%). Culture-based or molecular investigations were performed in 28.8% and 22.1% of the clinical specimens, respectively. The water systems were routinely tested for Legionella in 97.4% of the hospitals, 62% of which detected a positive result (> 1000 cfu/L). Legionella pneumophila serogroup 2–15 was the most frequently isolated species (58.4%). The most common control measures were the disinfection of the water system (73.7%), mostly through thermal shock (37.4%) and chlorine dioxide (34.4%), and the replacement (69.7%) or cleaning (70.4%) of faucets and showerheads. A dedicated multidisciplinary team was present in 52.8% of the hospitals, and 73% of the hospitals performed risk assessment. Targeted training courses were organized in 36.5% of the hospitals, involving nurses (30.7%), physicians (28.8%), biologists (21.5%), technicians (26.4%), and cleaners (11%). Control and prevention measures for legionellosis are present in Italian hospitals, but some critical aspects should be improved. More appropriate risk assessment is necessary, especially in large facilities with a high number of hospitalizations. Moreover, more sensitive diagnostic tests should be used, and dedicated training courses should be implemented.

54 ENVIRONMENTAL SCIENCES↗

Residential solar-heating system

Complete residential solar-heating and hot-water system, when installed in highly-insulated energy-saver home, can supply large percentage of total energy demand for space heating and domestic hot water. System which uses water-heating energy storage can be scaled to meet requirements of building in which it is installed.

Source record↗

Water Containment Systems for Testing High-Speed Flywheels

Water-filled containers are used as building blocks in a new generation of containment systems for testing high-speed flywheels. Such containment systems are needed to ensure safety by trapping high-speed debris in the event of centrifugal breakup or bearing failure. Traditional containment systems for testing flywheels consist mainly of thick steel rings. The effectiveness of this approach to shielding against high-speed debris was demonstrated in a series of tests.

Trase, Larry↗