Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WELLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Influence of magnetic field strength on potential well in the ionization stage of a double stage Hall thruster

Similar to a single stage Hall thruster, the magnetic field, which controls electron trajectory and electric field distribution, is the most important factor determining the performance of a double stage Hall thruster. Especially, a potential well, which is helpful to reduce the ion loss on the thruster walls, is shaped in the ionization stage due to the existence of an annular magnetic field topology there. In this paper, the influence of magnetic field strength in the ionization stage on the potential well is researched with both experiments and particle-in-cell simulations. It is found that the depth of potential well increases with the magnetic field strength as a result of enhanced magnetic confinement and lowered electron conductivity. Consequently, the plasma density as well as the ion current entering the acceleration stage increases. However, an excessive magnetic field strength leads to an excess of ion loss on the walls of the acceleration stage. Therefore, there is an appropriate magnetic field strength in the ionization stage that results in a proper potential well and consequently an optimal performance of a double stage Hall thruster.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Room-temperature stability of excitons and transverse-electric polarized deep-ultraviolet luminescence in atomically thin GaN quantum wells

Here, we apply first-principles calculations to study the effects of extreme quantum confinement on the electronic, excitonic, and radiative properties of atomically thin (1–4 atomic monolayers) GaN quantum wells embedded in AlN. We determine the quasiparticle bandgaps, exciton energies and wave functions, radiative lifetimes, and Mott critical densities as a function of well and barrier thickness. Our results show that quantum confinement in GaN monolayers increases the bandgap up to 5.44 eV and the exciton binding energy up to 215 meV, indicating the thermal stability of excitons at room temperature. Exciton radiative lifetimes range from 1 to 3 ns at room temperature, while the Mott critical density for exciton dissociation is approximately 10 13 cm -2 . The luminescence is transverse-electric polarized, which facilitates light extraction from c-plane heterostructures. We also introduce a simple approximate model for calculating the exciton radiative lifetime based on the free-carrier bimolecular radiative recombination coefficient and the exciton radius, which agrees well with our results obtained with the Bethe–Salpeter equation predictions. In conclusion, our results demonstrate that atomically thin GaN quantum wells exhibit stable excitons at room temperature for potential applications in efficient light emitters in the deep ultraviolet as well as room-temperature excitonic devices.

36 MATERIALS SCIENCE↗

How well do one-electron self-interaction-correction methods perform for systems with fractional electrons?

Recently developed locally scaled self-interaction correction (LSIC) is a one-electron SIC method that, when used with a ratio of kinetic energy densities (z σ ) as iso-orbital indicator, performs remarkably well for both thermochemical properties as well as for barrier heights overcoming the paradoxical behavior of the well-known Perdew–Zunger self-interaction correction (PZSIC) method. In this work, we examine how well the LSIC method performs for the delocalization error. Our results show that both LSIC and PZSIC methods correctly describe the dissociation of $H$$^{+}_{2}$ and $H$$^{+}_{2}$ but LSIC is overall more accurate than the PZSIC method. Likewise, in the case of the vertical ionization energy of an ensemble of isolated He atoms, the LSIC and PZSIC methods do not exhibit delocalization errors. For the fractional charges, both LSIC and PZSIC significantly reduce the deviation from linearity in the energy vs number of electrons curve, with PZSIC performing superior for C, Ne, and Ar atoms while for Kr they perform similarly. The LSIC performs well at the endpoints (integer occupations) while substantially reducing the deviation. The dissociation of LiF shows both LSIC and PZSIC dissociate into neutral Li and F but only LSIC exhibits charge transfer from Li + to F – at the expected distance from the experimental data and accurate ab initio data. Overall, both the PZSIC and LSIC methods reduce the delocalization errors substantially.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adiabatic splitting, transport, and self-trapping of a Bose-Einstein condensate in a double-well potential

We show that the adiabatic dynamics of a Bose-Einstein condensate (BEC) in a double-well potential can be described in terms of a dark variable resulting from the combination of the population imbalance and the spatial atomic coherence between the two wells. By means of this dark variable, we extend, to the nonlinear matter-wave case, the recent proposal by Vitanov and Shore [Phys. Rev. A 73, 053402 (2006)] on adiabatic passage techniques to coherently control the population of two internal levels of an atom or molecule. We investigate the conditions to adiabatically split or transport a BEC as well as to prepare an adiabatic self-trapping state by the optimal delayed temporal variation of the tunneling rate via either the energy bias between the two wells or the BEC nonlinearity. The emergence of nonlinear eigenstates and unstable stationary solutions of the system as well as their role in the breaking down of the adiabatic dynamics is investigated in detail.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pressure Transducer Measurement Variability in Deep Wells Screened Across the Water Table

Abstract Automated water level measurements collected using vented pressure transducers in deep wells screened across the water table may exhibit a greater response to barometric pressure changes than the true water level. The cause was hypothesized to be disequilibrium in barometric pressure between the wellbores and land surface due to air exchange with the deep vadose zone. In this study, vented and nonvented pressure transducers were installed and operated simultaneously in two deep wells screened across the water table. A vent tube open to the atmosphere at land surface allowed for barometric compensation of the vented transducers. Two nonvented transducers were installed in each well, one submerged in the water and one above the water surface. The difference in readings allowed for barometric compensation. Manual measurements were also collected. It was confirmed that measurements from the vented transducers exhibited greater variability in response to barometric pressure changes than the nonvented transducers and manual measurements. Comparison of the downhole barometric pressure measurements to values from a nearby meteorology station showed the response in the wells to changes in barometric pressure was time‐lagged and attenuated. Thus, the reference pressure from land surface supplied to the vented transducers was not representative of the air pressure within the wells. This caused fluctuations of the transducer readings in response to barometric pressure changes to be greater than the true water level change. This issue can be resolved by the use of nonvented pressure transducers.

McDonald, John P.↗

A field-shaping multi-well avalanche detector for direct conversion amorphous selenium

Purpose: A practical detector structure is proposed to achieve stable avalanche multiplication gain in direct-conversion amorphous selenium radiation detectors. Methods: The detector structure is referred to as a field-shaping multi-well avalanche detector. Stable avalanche multiplication gain is achieved by eliminating field hot spots using high-density avalanche wells with insulated walls and field-shaping inside each well. Results: The authors demonstrate the impact of high-density insulated wells and field-shaping to eliminate the formation of both field hot spots in the avalanche region and high fields at the metal-semiconductor interface. Results show a semi-Gaussian field distribution inside each well using the field-shaping electrodes, and the electric field at the metal-semiconductor interface can be one order-of-magnitude lower than the peak value where avalanche occurs. Conclusions: This is the first attempt to design a practical direct-conversion amorphous selenium detector with avalanche gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A radiation quality correction factor k{sub Q} for well-type ionization chambers for the measurement of the reference air kerma rate of {sup 60}Co HDR brachytherapy sources

Purpose: The aim of this study was to investigate whether a chamber-type-specific radiation quality correction factor k{sub Q} can be determined in order to measure the reference air kerma rate of {sup 60}Co high-dose-rate (HDR) brachytherapy sources with acceptable uncertainty by means of a well-type ionization chamber calibrated for {sup 192}Ir HDR sources. Methods: The calibration coefficients of 35 well-type ionization chambers of two different chamber types for radiation fields of {sup 60}Co and {sup 192}Ir HDR brachytherapy sources were determined experimentally. A radiation quality correction factor k{sub Q} was determined as the ratio of the calibration coefficients for {sup 60}Co and {sup 192}Ir. The dependence on chamber-to-chamber variations, source-to-source variations, and source strength was investigated. Results: For the PTW Tx33004 (Nucletron source dosimetry system (SDS)) well-type chamber, the type-specific radiation quality correction factor k{sub Q} is 1.19. Note that this value is valid for chambers with the serial number, SN ≥ 315 (Nucletron SDS SN ≥ 548) onward only. For the Standard Imaging HDR 1000 Plus well-type chambers, the type-specific correction factor k{sub Q} is 1.05. Both k{sub Q} values are independent of the source strengths in the complete clinically relevant range. The relative expanded uncertainty (k = 2) of k{sub Q} is U{sub k{sub Q}} = 2.1% for both chamber types. Conclusions: The calibration coefficient of a well-type chamber for radiation fields of {sup 60}Co HDR brachytherapy sources can be calculated from a given calibration coefficient for {sup 192}Ir radiation by using a chamber-type-specific radiation quality correction factor k{sub Q}. However, the uncertainty of a {sup 60}Co calibration coefficient calculated via k{sub Q} is at least twice as large as that for a direct calibration with a {sup 60}Co source.

60 APPLIED LIFE SCIENCES↗

Predominance and metabolic potential of Halanaerobium spp. in produced water from hydraulically fractured Marcellus Shale wells

Here, microbial activity in the produced water from hydraulically fractured oil and gas wells may potentially interfere with hydrocarbon production and cause damage to the well and surface infrastructure via corrosion, sulfide release, and fouling. In this study, we surveyed the microbial abundance and community structure of produced water sampled from 42 Marcellus Shale wells in southwestern Pennsylvania (well age ranged from 150 to 1,846 days) to better understand the microbial diversity of produced water. We sequenced the V4 region of the 16S rRNA gene to assess taxonomy and utilized quantitative PCR (qPCR) to evaluate the microbial abundance across all 42 produced water samples. Bacteria of the order Halanaerobiales were found to be the most abundant organisms in the majority of the produced water samples, emphasizing their previously suggested role in hydraulic fracturing-related microbial activity. Statistical analyses identified correlations between well age and biocide formulation and the microbial community, in particular, the relative abundance of Halanaerobiales . We further investigated the role of members of the order Halanaerobiales in produced water by reconstructing and annotating a Halanaerobium draft genome (named MDAL1), using shotgun metagenomic sequencing and metagenomic binning. The recovered draft genome was found to be closely related to the species H. congolense, an oil field isolate, and Halanaerobium sp. strain T82-1, also recovered from hydraulic fracturing produced water. Reconstruction of metabolic pathways revealed Halanaerobium sp. strain MDAL1 to have the potential for acid production, thiosulfate reduction, and biofilm formation, suggesting it to have the ability to contribute to corrosion, souring, and biofouling events in the hydraulic fracturing infrastructure.

04 OIL SHALES AND TAR SANDS↗

Enhanced Surgical Decision-Making Tools in Breast Cancer: Predicting 2-Year Postoperative Physical, Sexual, and Psychosocial Well-Being following Mastectomy and Breast Reconstruction (INSPiRED 004)

Background: We sought to predict clinically meaningful changes in physical, sexual, and psychosocial well-being for women undergoing cancer-related mastectomy and breast reconstruction 2 years after surgery using machine learning (ML) algorithms trained on clinical and patient-reported outcomes data. Patients and Methods: We used data from women undergoing mastectomy and reconstruction at 11 study sites in North America to develop three distinct ML models. We used data of ten sites to predict clinically meaningful improvement or worsening by comparing pre-surgical scores with 2 year follow-up data measured by validated Breast-Q domains. We employed ten-fold cross-validation to train and test the algorithms, and then externally validated them using the 11th site’s data. We considered area-under-the-receiver-operating-characteristics-curve (AUC) as the primary metric to evaluate performance. Results: Overall, between 1454 and 1538 patients completed 2 year follow-up with data for physical, sexual, and psychosocial well-being. In the hold-out validation set, our ML algorithms were able to predict clinically significant changes in physical well-being (chest and upper body) (worsened: AUC range 0.69–0.70; improved: AUC range 0.81–0.82), sexual well-being (worsened: AUC range 0.76–0.77; improved: AUC range 0.74–0.76), and psychosocial well-being (worsened: AUC range 0.64–0.66; improved: AUC range 0.66–0.66). Baseline patient-reported outcome (PRO) variables showed the largest influence on model predictions. Conclusions: Machine learning can predict long-term individual PROs of patients undergoing postmastectomy breast reconstruction with acceptable accuracy. This may better help patients and clinicians make informed decisions regarding expected long-term effect of treatment, facilitate patient-centered care, and ultimately improve postoperative health-related quality of life.

60 APPLIED LIFE SCIENCES↗

Cape EGS: Frisco Pad Wells Flow Test Microseismic Data

This dataset contains microseismic data acquired during the Frisco pad flow test project led by Fervo Energy, conducted between July 17th - Aug 12th 2024, near the Utah FORGE geothermal site. The microseismic data was collected from various Utah FORGE wells: via Distributed Acoustic Sensing (DAS) fiber in 16B, and two 3-component geophones located in wells 56-32 and 78B. The dataset is structured in SEGY format, where the first six traces represent data from the geophones, and the remaining traces capture DAS data from well 16B. Each SEGY file in this dataset contains triggered microseismic events, with event initiation based on Short-Time Average over Long-Time Average (STA/LTA) detection criteria during the stimulation process. Files are grouped by time intervals and named following the structure "[WellPad][WellName][Month]_[Year]Divine_Trigger[EventNumber].sgy," indicating well pad, well name, date, and event number. Sampling parameters include a spatial sampling of approximately 2 meters for DAS channels and a temporal sampling rate of 2000 Hz, with each data record spanning 1.2 seconds. The files' coordinates are referenced to the location of the FORGE 16A-32 wellhead, positioned at UTM coordinates: Easting 334641.1891 m and Northing 4263443.693 m. The geographic coordinates for this origin are 38.50402147 latitude and -112.8963897 longitude, with an elevation of 1650.0249 meters above sea level.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Neubrex Well 16B(78)-32 DAS Data - April, 2024

This dataset comprises Distributed Acoustic Sensing (DAS) data collected from the Utah FORGE monitoring well 16B(78)-32 (the producer well) during hydraulic fracture stimulation operations conducted in April 2024. The data were acquired continuously over the stimulation period at a temporal sampling rate of 10,000 Hz (10 kS/s) and a spatial resolution of approximately 3.35 feet (1.02109 meters). The measurements were captured using a Neubrex NBX-S4100 Time Gated Digital DAS interrogator unit connected to a single-mode fiber optic cable, which was permanently installed within the casing string. All recorded channels correspond to downhole segments of the fiber optic cable, from a measured depth (MD) of 5,369.35 feet to 10,352.11 feet. The DAS data reflect raw acoustic energy generated by physical processes within and surrounding the well during stimulation activities at wells 16A(78)-32 and 16B(78)-32. These data have potential applications in analyzing cross-well strain, far-field strain rates (including microseismic activity), induced seismicity, and seismic imaging. Metadata embedded in the attributes of the HDF5 files include detailed information on the measured depths of the channels, interrogation parameters, and other acquisition details. The dataset also includes a recording of a seminar held on September 19, 2024, where Neubrex's Chief Operating Officer presented insights into the data collection, analysis, and preliminary findings. The raw data files, stored in HDF5 format, are organized chronologically according to the recording intervals from April 9 to April 24, 2024, with each file corresponding to a 12-second recording interval.

15 GEOTHERMAL ENERGY↗

Multi-Scale Lithofacies and Chemostratigraphic Analysis of Two Middle Devonian Marcellus Shale Wells in Northern West Virginia, USA

The Marcellus Shale Energy and Environmental Laboratory (MSEEL) consists of two project areas within the dry gas producing region of the Marcellus shale play in Monongalia County, West Virginia. MSEEL is a collaborative field project led by West Virginia University, with Northeast Natural Energy LLC, several industrial partners, and sponsored by the US Department of Energy National Energy Technology Laboratory. The study areas are drilled approximately 8.5 miles apart to better understand the vertical and lateral changes in stratigraphy over a short distance. Two vertical pilot wells, MIP-3H and Boggess 17H were drilled in the fall of 2015 and spring of 2019, respectively. Core was recovered from the MIP-3H (API: 47-061-01707-00-00) 112 feet (34m) between depths of 7445 to 7557 feet, and from the Boggess 17H (API: 47-061-01812-00-00) 139 feet (42m) between depths of 7908 and 8012 ft. A full suite of triple combo (gamma ray, neutron, density logs), image logs, and advanced logging tools were run in both wells and calibrated to core analysis. Core analysis includes medical computed tomography (CT) scans, mineralogy and chemostratigraphy determined from handheld X-Ray fluorescence (hhXRF) and X-Ray powder diffraction (XRD) measurements, and determination of total organic content (TOC). Lithofacies were determined at core-scale using traditional core description techniques and medical CT-scan images. Log-scale facies are based on mineralogy and TOC data and developed using petrophysical logging data calibrated to core data (XRD and pyrolysis data). Chemostratigraphic analysis utilized hhXRF data to determine the major and trace element trends in the cores. In the two wells six shale lithofacies were recognized at the core and log scale. Both wells show organic-rich facies (TOC > 6.5%) primarily in the middle and lower Marcellus, with a slight decrease in thickness of this interval in the Boggess 17H. This interval is interpreted as an increase in paleo-productivity (increased Ni, Zn, and V), decreased sedimentation (decreased detrital proxies), and anoxic to euxinic conditions (increased Mo and chalcophile elements). Paleo-redox conditions in both wells are dynamic throughout deposition transitioning between euxinic/anoxic to dysoxic/oxic. This trend is seen through elemental proxies and calcite/pyrite concretion distributions.

03 NATURAL GAS↗

Core Analysis E-Reports Produced for the Southwest Regional Partnership on Carbon Sequestration for Wells 13-10A, 13-14, and 32-8 of the Farnsworth Unit, Texas

The submission is three electronic reports (e-reports) produced by Terra Tek, a former Schlumberger company, for and under the oversight of the Southwest Regional Partnership on Carbon Sequestration (SWP). The SWP designed and implemented a coring and core analysis program in conjunction with the previous field operator Chaparral Energy, L.L.C. The main SWP contacts who oversaw the coring and core analysis program, including geologic core descriptions and sample selection for testing by the Terra Tek, are listed below in the Authors section. The three reports are for Wells 13-10A, 13-14, and 32-8 of the Farnsworth Unit, TX, a site of the SWP's CO2 storage and enhanced oil recovery project. The e-reports include many data types that are not listed in full detail here, but may include: geomechanical, geochemical, and petrophysical measurements; white light and UV core photos; spectral gamma logs on the core; and Heterogeneous Rock Analysis logs. Fracture core review reports are included for Wells 13-14 and 32-8. The three e-reports each have many subfolders with the various types of data in spreadsheets, pdfs, image files, or other formats. The main e-reports for each well are listed by the well name. The sub-folder “E-Report” for each well has a Report.html file, which, when opened, will have hyperlinks to the various data sets and information. The files in the zipped folder will need to be extracted for the Report.html files to work properly. These authors thank Joseph Hall, a geologist formerly of Chaparral Energy, L.L.C., for assistance in designing the coring program, his geologic expertise of the Farnsworth Unit, and his assistance with characterizing the core. Christopher Gillespie, of Terra Tek at the time, managed the myriad geomechanical, geochemical, and petrophysical measurements provided by Terra Tek for this project. The core from which the samples were collected for this project are housed at the Subsurface Data and Core Libraries of the New Mexico Bureau of Geology and Mineral Resources, Socorro, New Mexico, USA. Funding for this project is provided by the U.S. Department of Energy's (DOE) National Energy Technology Laboratory (NETL) through the Southwest Regional Partnership on Carbon Sequestration (SWP) under Award No. DE-FC26-05NT42591. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. These e-reports describe objective technical results and analysis. Any subjective views or opinions that might be expressed in the reports do not necessarily represent the views of the US Department of Energy or the United States Government.

Caprock↗

Completion Report for Well ER-EC-12 Corrective Action Units 101 and 102: Central and Western Pahute Mesa

Well ER-EC-12 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Restoration Project at the Nevada National Security Site (formerly known as the Nevada Test Site), Nye County, Nevada. The well was drilled in June and July 2010 as part of the Pahute Mesa Phase II drilling program. The primary purpose of the well was to provide detailed hydrogeologic information in the Tertiary volcanic section in the area between Pahute Mesa and the Timber Mountain caldera complex that will help address uncertainties within the Pahute Mesa–Oasis Valley hydrostratigraphic model. In particular, the well was intended to help define the structural position and hydraulic parameters for volcanic aquifers potentially down-gradient from historic underground nuclear tests on Pahute Mesa. It may also be used as a long-term monitoring well.

54 ENVIRONMENTAL SCIENCES↗

Completion Report for Well ER-EC-15 Corrective Action Units 101 and 102: Central and Western Pahute Mesa

Well ER-EC-15 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Restoration Project at the Nevada National Security Site (formerly known as the Nevada Test Site), Nye County, Nevada. The well was drilled in October and November 2010, as part of the Pahute Mesa Phase II drilling program. The primary purpose of the well was to provide detailed hydrogeologic information in the Tertiary volcanic section in the area between Pahute Mesa and the Timber Mountain caldera complex that will help address uncertainties within the Pahute Mesa–Oasis Valley hydrostratigraphic model. In particular, the well was intended to help define the structural position and hydraulic parameters of volcanic aquifers potentially down-gradient from underground nuclear tests on Pahute Mesa. It may also be used as a long-term monitoring well.

54 ENVIRONMENTAL SCIENCES↗

Vapor Extraction Well Performance and Recommendations for Future Soil Vapor Extraction Activities at the A-014 Outfall

The vadose zone near the A-014 Outfall contains residual volatile organic compounds that serve as a potential source for groundwater contamination. Since 1995 active soil vapor extraction has been an integral part of the corrective actions at this facility. Currently two separate soil vapor extraction systems are being used to remove contamination in the vapor phase from the subsurface. The 782-3M soil vapor extraction unit was deployed in April of 1995 and the A-014 Mobile #3 unit was deployed in January of 2009. The objective of this investigation is to evaluate the performance of individual wells associated with these systems and provide recommendations on possible optimizations to these systems. Options that are considered include continuation of active extraction, transition to a low-energy soil vapor extraction treatment, or abandon nonperforming wells. The scope of the investigation examined the eighteen (18) vadose zone wells that are associated with the ongoing Resource Conservation and Recovery Act corrective action program within A/M Area. During the evaluation process, individual wells were isolated and purged for a standard period using the existing soil vapor extraction system. Following the purge period, vapor samples were collected intermittently over the following 24–72-hour period. The objective of the sampling activity was to collect sufficient data to estimate the mass flow rate of contaminants from the individual extraction wells. Subsequent analysis then evaluated and ranked extraction performance to provide recommendations on the viability, operational scheme, and applicability of low energy soil vapor extraction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Cavern and Well Stability at the West Hackberry SPR Site Using a Full-Dome Model

This report presents computational analyses that simulate the structural response of caverns at the Strategic Petroleum Reserve (SPR) West Hackberry site. The cavern field comprises 22 caverns. Five caverns (6, 7, 8, 9, 11) were acquired from industry and have unusual shapes and a history dating back to 1946. The other 17 caverns (101-117) were leached according to SPR standards in the mid-1980s and have tall cylindrical shapes. The history of the caverns and their shapes are simulated in a three-dimensional geomechanics model of the site that predicts deformations, strains, and stresses. Future leaching scenarios corresponding to oil drawdowns using fresh water are also simulated by increasing the volume of the caverns. Cavern pressures are varied in the model to capture operational practices in the field. The results of the finite element model are interpreted to provide information on the current and future status of subsidence, well integrity, and cavern stability. The most significant results in this report are relevant to Cavern 6. The cavern is shaped like a bowl with a large ceiling span and is in close proximity to Cavern 9. The analyses predict tensile stresses at the edge of the ceiling during repressurization of Cavern 6 following workover conditions. During a workover the cavern is at low pressure to service a well. The wellhead pressures are atmospheric. When the workover is complete, the cavern is repressurized. The resulting elastic stresses are sufficient to cause tension around the edge of the large ceiling span. With time, these stresses relax to a compressive state because of salt creep. However, the potential for salt fracture and propagation exists, particularly towards Cavern 9. With only 200 feet of salt between the caverns, the operational consequences must be examined if the two caverns become connected. A critical time may be during a workover of Cavern 9 in part because of the operational vulnerabilities, but also because dilatant damage is predicted under the ledge that forms the lower lobe in the cavern. The remaining caverns have no significant issues regarding cavern stability and may be safely enlarged during subsequent oil drawdowns. Predicted well strains and subsidence are significant and consequently future remedial actions may be necessary. These predicted well strains certainly suggest appropriate monitoring through a well-logging program. Subsidence is currently being monitored.

02 PETROLEUM↗

Active Well Counting Using New PSD Plastic Detectors

This report presents results and analysis from a series of proof-of-concept measurements to assess the suitability of segmented detectors constructed from Eljen EJ-299-34 PSD-plastic scintillator with pulse-shape discrimination capability for the purposes of quantifying uranium via active neutron coincidence counting. Present quantification of bulk uranium materials for international safeguards and domestic materials control and accounting relies on active neutron coincidence counting systems, such as the Active Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL), that use moderated He-3 proportional counters along with necessarily low-intensity 241Am(Li) neutron sources. Scintillation-based fast-neutron detectors are a potentially superior technology to the existing AWCC and UNCL designs due to their spectroscopic capability and their inherently short neutron coincidence times that largely eliminate random coincidences and enable interrogation by stronger sources. One of the past impediments to the investigation and adoption of scintillation counters for the purpose of quantifying bulk uranium was the commercial availability of scintillators having the necessary neutron-gamma pulse-shape discrimination properties only as flammable liquids. Recently, Eljen EJ-299-34 PSD-plastic scintillator became commercially available. The present work is the first assessment of an array of PSD-plastic detectors for the purposes of quantifying bulk uranium. The detector panel used in the present work was originally built as the focal plane for a fast-neutron imager, but it was repurposed for the present investigation by construction of a stand to support the inner well of an AWCC immediately in front of the detector panel. The detector panel and data acquisition of this system are particularly well suited for performing active-well fast-neutron counting of LEU and HEU samples because the active detector volume is solid, the 241Am(Li) interrogating neutrons are largely below the detector threshold, and the segmented construction of the detector modules allow for separation of true neutron-neutron coincidences from inter-detector scattering using the kinematics of neutron scattering. The results from a series of measurements of a suite of uranium standards are presented, and compared to measurements of the same standards and source configurations using the AWCC. Using these results, the performance of the segmented detectors reconfigured as a well counter is predicted and outperforms the AWCC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗