Freshwater Flux Variability Lengthens the Period of the Low-Frequency AMOC Variability

Atlantic Meridional Overturning Circulation (AMOC) exhibits interdecadal to multidecadal variability, yet the extent to which the surface freshwater flux (FWF) variability affects the AMOC variability remains unclear. This study isolates the contribution of FWF variability in modulating AMOC through a partially coupled experiment, in which the FWF effect from the atmosphere and sea ice are disabled. It is demonstrated that the FWF effect can remarkably enhance the persistence of positive salinity anomalies in the Labrador Sea, and sustain the dense water formation that was initiated by the cold temperature anomalies. Therefore, the FWF variability serves as a positive feedback on AMOC and lengthens the period of the AMOC oscillation. Further lead-lag regressions of atmospheric and oceanic variables onto the AMOC time series illuminate that the persistent salinity anomalies are generated through two pathways: i) the phase lag between temperature and salinity anomalies in the Labrador Sea; and ii) a downstream propagation of extra high-salinity anomaly along the East Greenland Current, due to the reduced sea ice melting flux associated with an atmosphere forcing over the southern Greenland tip.

58 GEOSCIENCES↗

Reply to: Low-frequency quantum oscillations in LaRhIn 5 : Dirac point or nodal line?

We thank G.P. Mikitik and Yu.V. Sharlai for contributing this note and the cordial exchange about it. First and foremost, we note that the aim of our paper is to report a methodology to diagnose topological (semi)metals using magnetic quantum oscillations. Thus far, such diagnosis has been based on the phase offset of quantum oscillations, which is extracted from a “Landau fan plot”. A thorough analysis of the Onsager–Lifshitz–Roth quantization rules has shown that the famous π-phase shift can equally well arise from orbital or spin magnetic moments in topologically trivial systems with strong spin-orbit coupling or small effective masses. Therefore, the “Landau fan plot” does not by itself constitute a proof of a topologically nontrivial Fermi surface. In the paper at hand, we report an improved analysis method that exploits the strong energy dependence of the effective mass in linearly dispersing bands. This leads to a characteristic temperature dependence of the oscillation frequency which is a strong indicator of nontrivial topology, even for multi-band metals with complex Fermi surfaces. Three materials, Cd 3 As 2 , Bi 2 O 2 Se and LaRhIn5 served as test cases for this method. Linear band dispersions were detected for Cd 3 As 2 , as well as the F ≈ 7 T pocket in LaRhIn 5 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of a low frequency, density profile reflectometer system for the MAST-U spherical tokamak

Validated and accurate edge profiles (temperature, density, etc.) are vitally important to the Mega Ampere Spherical Tokamak Upgrade (MAST-U) divertor and confinement effort. Density profile reflectometry has the potential to significantly add to the measurement capabilities currently available on MAST-U (e.g., Thomson scattering and Langmuir probes). This work presents the diagnostic requirements, problems, and solutions facing profile reflectometry in spherical tokamaks and MAST-U in particular. Requirements include density measurements near zero electron density in the scrape off layer region, coverage for a broad range of MAST-U plasma parameters, high time (≤10 microseconds) and spatial resolutions (≤1 cm), reliability, and identification of the plasma start frequency.

Instruments & Instrumentation↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Bandwidth and Beam Profile Characteristics of a Simple Low-Frequency Collimated Ultrasound Beam Source

We numerically investigate the bandwidth and collimation characteristics of ultrasound beams generated by a simple collimated ultrasound beam source that consists of a piezoelectric disk operated near its radial mode resonances. We simulate the ultrasound beam generated in a fluid medium as a function of the excitation frequency for two cases: (1) free piezoelectric disk that corresponds to zero-traction along the lateral edge and (2) fixed piezoelectric disk that corresponds to zero-displacement along the lateral edge. We present and discuss the physical mechanism underpinning the frequency-dependent collimation and bandwidth properties of the ultrasound beams. We observe that the collimated beam generated by the free disk repeatedly lengthens/shortens and also extends/retracts sidelobes with increasing frequency. Alternatively, fixing the piezoelectric disk results in a consistent beam profile shape across a broad range of frequencies. This facilitates generating broadband signals such as a Gaussian pulse or chirp, which are common in ultrasound imaging. Thus, the fixed piezoelectric disk finds application as a collimated ultrasound beam source in a wide range of applications including medical ultrasound imaging, scanning acoustic microscopy, sonar detection, and other nondestructive ultrasound inspection techniques.

47 OTHER INSTRUMENTATION↗

Relaxation behavior in low-frequency complex conductivity of sands caused by bacterial growth and biofilm formation by Shewanella oneidensis under a high-salinity condition

Complex electrical conductivity is increasingly used to monitor subsurface processes associated with microbial activities because microbial cells mostly have surface charges and thus electrical double layers. Although highly saline environments are frequently encountered in coastal and marine sediments, there are limited data available on the complex conductivity associated with microbial activities under a high-salinity condition. Therefore, we have developed the spectral responses of complex conductivity of sand associated with bacterial growth and biofilm formation under a highly saline condition of approximately 1% salinity and approximately 2 S/m pore water conductivity with an emphasis on relaxation behavior. A column test is performed, in which the model bacteria Shewanella oneidensis MR-1 are stimulated for cell growth and biofilm formation in a sand pack, whereas the complex conductivity is monitored from 0.01 Hz to 10 kHz. The test results indicate that the real conductivity increases in the early stage due to the microbial metabolites and the increased surface conduction with cell growth but soon begin to decrease because of the reduction of charge passages due to bioclogging. However, the imaginary conductivity significantly increases with time, and clear bell-shaped relaxation behaviors are observed with the peak frequency of 0.1–1 Hz, associated with the double-layer polarization of cells and electrically conductive pili and biofilms. The Cole-Cole relaxation model appears to capture such relaxation behaviors well, and the modeling results indicate gradual increases in normalized chargeability and decreases in relaxation time during bacterial growth and biofilm formation in the highly saline condition. Comparison with previous literature confirms that the high-salinity condition further increases the normalized chargeability, whereas it suppresses the phase shift and thus the imaginary conductivity. Our results suggest that the complex conductivity can effectively capture microbial biomass formation in sands under a highly saline condition.

58 GEOSCIENCES↗

Low-frequency Electromagnetic Detection Limits of Underground Nuclear Explosions

Underground nuclear explosions produce a broadband electromagnetic signal that can propagate to the surface at some distance. We perform a logistic regression on historical electromagnetic detections to calculate a probabilistic detection curve for prediction of the propagation distance for any given underground nuclear explosion. The curve predicts positive detections at scaled ranges of 2414.6, 2025.7, 1908.3, and 1672.4 m/ktonne 1/3 at probabilities of 50, 90, 95 and 99%, respectively. For a theoretical 100 ktonne underground nuclear explosion these scaled ranges translate to absolute ranges of 11.2, 9.4, 8.9, and 7.8 km at probabilities of 50, 90, 95 and 99%, respectively. We also motivate a need for improved electromagnetic sensor design and deployment by extending the detection analysis using the quoted signal-to-noise ratio of two and noise amplitude of 10 pT along with attenuation relationships that go as 1/r to 1/r 3 . We find that reducing the noise floor by a factor often could extend the detection limit to approximately 5 to 25 km/ktonne 1/3 , which translates to 24 to 112 km for a theoretical 100 ktonne underground nuclear explosion.

58 GEOSCIENCES↗

A Miniaturized Long-Life, Low-Frequency Acoustic Transmitter for Fish Tracking in Marine Environment - CRADA 447

Advance state-of-art technologies for tracking marine mammals, fish, sea turtles, and other protected species, based on acoustic telemetry. Objectives include: (1) develop a new acoustic transmitter that has a greatly improved detection range and service life while being significantly smaller and lighter than the existing commercial counterparts; and (2) reach a TRL of 5 so the technology is ready for organizations interested in small- or medium-scale field trials.