Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Pressure Transducer Measurement Variability in Deep Wells Screened Across the Water Table

Abstract Automated water level measurements collected using vented pressure transducers in deep wells screened across the water table may exhibit a greater response to barometric pressure changes than the true water level. The cause was hypothesized to be disequilibrium in barometric pressure between the wellbores and land surface due to air exchange with the deep vadose zone. In this study, vented and nonvented pressure transducers were installed and operated simultaneously in two deep wells screened across the water table. A vent tube open to the atmosphere at land surface allowed for barometric compensation of the vented transducers. Two nonvented transducers were installed in each well, one submerged in the water and one above the water surface. The difference in readings allowed for barometric compensation. Manual measurements were also collected. It was confirmed that measurements from the vented transducers exhibited greater variability in response to barometric pressure changes than the nonvented transducers and manual measurements. Comparison of the downhole barometric pressure measurements to values from a nearby meteorology station showed the response in the wells to changes in barometric pressure was time‐lagged and attenuated. Thus, the reference pressure from land surface supplied to the vented transducers was not representative of the air pressure within the wells. This caused fluctuations of the transducer readings in response to barometric pressure changes to be greater than the true water level change. This issue can be resolved by the use of nonvented pressure transducers.

McDonald, John P.↗

Moisture performance of sealed attics in the mixed-humid climate

Oak Ridge National Laboratory studied 8 homes in the mixed-humid climate, 4 with vented attics and 4 with sealed attics. ORNL wanted to understand the moisture performance of the sealed attic and how it affected the interior environment. We found that the attic and interior of sealed attic homes were more humid than the attic and interior observed in vented attic homes. This is due to the lack of ventilation in the sealed attic. Historically attics have been vented to dehumidify the attic and interior of the home. A sealed attic design greatly reduces the venting potential and thus this drying pathway and can cause elevated interior moisture over a vented attic home. Despite the elevated attic and interior moisture in the sealed attic homes, so far no mold or material degradation has been found. The roof sheathing moisture content has stayed below 20%, indicating low potential for material degradation. Also the relative humidity at the roof sheathing has stayed within the ASHRAE 160 design criteria except for a short time during the 2011/2012 winter. This was due to a combination of the sealed attic design (minimal venting to the outside) and the duct work not being operated in the attic which usually provides a dehumidification pathway. It was also found that when the humidity was controlled using the HVAC system, it resulted in 7% more cooling energy consumption. In the mixed-humid climate this reduces the cost effectiveness of the sealed attic design as a solution for bringing ducts into a semi-conditioned space. Because of this we are recommending the other alternatives be used to bringing ducts into the conditioned space in both new construction and retrofit work in the mixed-humid climate.

54 ENVIRONMENTAL SCIENCES↗

Indoor Climate and Moisture Durability Performances of Houses with Unvented Attic Roof Constructions in a Mixed-Humid Climate

A sealed or unvented attic is an energy-efficient envelope component that can reduce the amount of energy a house consumes for space conditioning if the air handler and/or ducts are located in the attic. The attic is typically sealed by using spray foam on the underside of the roof deck and covering the soffit, ridge and gable vents to minimize air leakage from the attic to the outside. This approach can save up to 10% in space-conditioning energy when ducts are located in the attic (DOE 2013). Past research done by ORNL and Florida Solar Energy Center suggests that in more hot, humid climates, an unvented attic could potentially create a more humid, uncomfortable living environment than a vented attic (Colon 2011, Boudreaux, Pallin et al. 2013). Research showed that controlling the higher indoor humidity could reduce the energy savings from the sealed, unvented attic, which in turn would decrease the energy savings payback. Research also showed that the roof assembly (5.5 inches of open-cell foam, 1inch of closed-cell foam, OSB, felt paper, and asphalt shingles) stored moisture, thus acting as a moisture buffer. During the fall and winter, the roof assembly stored moisture and during the spring and summer it released moisture. This phenomenon is not seen in a vented attic, in which the air exchange rate to the outside is greater and, in the winter, helps to dehumidify the attic air. It was also seen that in a vented attic, the direction of water vapor diffusion is on average from the attic to the interior of the house. Air leakage from the attic to the interior also occurs during more of the year in a house with an unvented attic than in one with a vented attic. These discoveries show that the moisture dynamics in a house with an unvented attic are much different from those in a house with a vented attic. This study reports on a series of computer model investigations completed to determine the key variables impacting indoor comfort and the durability of roof assemblies against moisture. The key variables investigated were the leakage area from the attic to the outside, leakage area from the attic to the interior, leakage area from the interior to the outside, supply duct leakage in the attic, and interior moisture generation. These investigations are described in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Component-Specific Measurements to Develop Emission Factors for Compressors and Gas Gathering Lines

The Department of Energy (DOE) National Energy Technology Laboratory (NETL) and other critical stakeholders (e.g., U.S. Environmental Protection Agency (USEPA), state regulators, and industry) seek to more accurately characterize and quantify methane emissions from compressors and gathering lines within the Gathering and Boosting (G&B) segment of the natural gas system network. These efforts will reduce uncertainties in emissions estimates in USEPA’s current Green House Gas Inventory (GHGI) under their Greenhouse Gas Reporting Program (GHGRP). For this study, four G&B stations in the Gulf Coast Area were visited four times over the course of one year. Components were classified according to equipment and component type and emissions from select components were measured using multiple measurement technologies. The following major equipment types were considered: i) compressors, ii) separators, iii) dehydrators, iv) coalescers, v) slug catchers, vi) yard piping, vii) tanks, and viii) gathering lines. Individual components on each equipment type were further divided into the following main categories: i) connectors, ii) valves, iii) pressure relief valves (PRV), iv) meters, v) gauges, vi) regulators, vii) pneumatic device vents, and viii) compressor vents (e.g., distance piece vents [DPVs] and rod packing vents [RPVs]). Components were screened for the presence of leaks and venting emissions with an optical gas imaging (OGI) camera, and methane emission rates were measured using a microdilution high volume sampler. Downwind emissions were measured using an Open Path Fourier Transform Infrared (OP-FTIR) Spectrometer. Data were evaluated to assess correlation with site, equipment, time, and operational variables. Key findings and recommendations from the study include: A) Different counting methodologies can result in vastly different component counts, thus influencing total emissions calculations using Subpart W population EFs. A standard methodology should be adopted for classifying and counting components in order to minimize inconsistencies across studies and instruct stakeholders responsible for GHGI reporting. B) Results support current component subcategories listed in USEPA Subpart W, including the subdivision of connectors (flanged and “other”) and pneumatic device vents (intermittent, continuous low bleed, and continuous high bleed). C) Emission rates vary across sites and a relationship between higher emissions and compressor age was observed for some components. D) Component emission rates varied between field campaigns. The type of components contributing to overall measured emissions also varied among field campaigns. However, the emission rate variability was larger between different components (of the same category) than the variability in one component over the four field campaigns. Therefore, when calculating emission factors, it is not necessary to take repeat measurements to capture component variability. E) Measuring the emission rate of a sample for an extended period of time is not necessary to capture the average component emission rate. F) For reporting purposes, excluding liquid lines from site-wide screening may have a negligible effect on component-related emissions. However, from a site management perspective, malfunctioning components were not uncommon on liquid lines and contributed substantially to fugitive emissions at some sites. G) Population EFs, whether including or excluding liquid lines, were a conservative estimate of fugitive emissions. Leaker EFs consistently underestimated emissions at the field sites. Measurements at more sites, particularity sites in other areas of the country, need to be completed before determining the accuracy of EFs.

03 NATURAL GAS↗

Small experiments for the maturation of orbital cryogenic transfer technologies

The no-vent method is a promising approach to handling the problems of low-g venting during propellant transfer. A receiver tank is first cooled to remove thermal energy from the tank wall and the resultant vapor vented overboard. The nozzles mix the incoming liquid and residual vapor in the tank maintaining a thermodynamic state which allows the tank to fill with liquid without venting. Ground based testing at NASA Lewis Research Center (LeRC) has demonstrated the no-vent fill process and attempted to bound its low-gravity performance. But, low-gravity testing is required to validate the method. As an alternative to using a dedicated spacecraft for validation, several small scale experiments to study no-vent fill in low-g were formulated. Cost goals quickly limited the search to two possibilities: a secondary payload on the space shuttle, or a small scale sounding rocket experiment. The key issues of small scale experimentation are discussed, and a conceptual design of a sounding rocket experiment with liquid hydrogen for studying the fill process is presented.

Chato, David J.↗

The VTRE Program: An overview

The Vented Tank Resupply Experiment (VTRE) Program is a NASA In-Space Technology Experiments Program (IN-STEP) that will develop, and fly a small, low cost space experiment to investigate, develop, and acquire needed data to extend and advance the technology of capillary vane fluid management devices to applications requiring direct venting of gas from tanks in low-gravity. GAS venting may be required for control of pressure, or to allow low-g fill of a tank with liquid while holding a constant tank back pressure by gas venting. Future space applications requiring these fluid management capabilities include both cryogenic and Earth storable fluid systems. The experiment is planned as a Shuttle Hitchhiker payload, and will be developed around two transparent tanks equipped with capillary vane devices between which a test liquid can be transferred. Experiments will be conducted for vented transfer, direct venting, stability of liquid positioning to accelerations within and significantly above the design values, and fluid reorientation by capillary wicking of liquid into the vane device following intentional liquid upset.

Bailey, William J.↗

Small experiments for the maturation of orbital cryogenic transfer technologies

The no-vent fill method is a promising approach to handle the problems of low-g venting during propellant transfer. A receiver tank is first cooled to remove thermal energy from the tank wall and the resultant vapor vented overboard. Then nozzles mix the incoming liquid and residual vapor in the tank maintaining a thermodynamic state which allows the tank to fill with liquid without venting. Ground based testing at NASA Lewis Research Center (LeRC) has demonstrated the no-vent fill process and attempted to bound its low-gravity performance. But, low-gravity testing is required to validate the method. As an alternative to using a dedicated spacecraft for validation the authors have formulated several small scale experiments to study no-vent fill in low-g. Cost goals quickly limited the search to two possibilities: a secondary payload on the Space Shuttle, or a small scale sounding rocket experiment. This paper will discuss the key issues of small scale experimentation and present a conceptual design of a sounding rocket experiment with liquid hydrogen for studying the fill process.

Chato, David J.↗

Demonstration of Metabolic Heat Regenerated Temperature Swing Adsorption Technology

Patent-pending Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is currently being investigated for removal and rejection of CO2 and heat from a Portable Life Support System (PLSS) to a Martian environment. The metabolically-produced CO2 present in the vent loop gas is collected using a CO2 selective adsorbent that has been cooled via a heat exchanger to near CO2 sublimation temperatures (approx.195K) with liquid CO2 obtained from Martian resources. Once the adsorbent is fully loaded, fresh warm, moist vent loop (approx.300K) is used to heat the adsorbent via another heat exchanger. The adsorbent will then reject the collected CO2 to the Martian ambient. Two beds are used to achieve continuous CO2 removal by cycling between the cold and warm conditions for adsorbent loading and regeneration, respectively. Small experiments have already been completed to show that an adsorbent can be cycled between these PLSS operating conditions to provide adequate conditions for CO2 removal from a simulated vent loop. One of the remaining technical challenges is extracting enough heat from the vent loop to warm the adsorbent in an appreciable time frame to meet the required adsorb/desorb cycle. The other key technical aspect of the technology is employing liquid CO2 to achieve the appropriate cooling. A technology demonstrator has been designed, built and tested to investigate the feasibility of 1) warming the adsorbent using the moist vent loop, 2) cooling the adsorbent using liquid CO2, and 3) using these two methods in conjunction to successfully remove CO2 from a vent loop and reject it to Mars ambient. Both analytical and numerical methods were used to perform design calculations and trades. The demonstrator was built and tested. The design analysis and testing results are presented along with recommendations for future development required to increase the maturity of the technology.

Paul, Heather↗

LOX Tank Helium Removal for Propellant Scavenging

System studies have shown a significant advantage to reusing the hydrogen and oxygen left in these tanks after landing on the Moon in fuel cells to generate power and water for surface systems. However in the current lander concepts, the helium used to pressurize the oxygen tank can substantially degrade fuel cell power and water output by covering the reacting surface with inert gas. This presentation documents an experimental investigation of methods to remove the helium pressurant while minimizing the amount of the oxygen lost. This investigation demonstrated that significant quantities of Helium (greater than 90% mole fraction) remain in the tank after draining. Although a single vent cycle reduced the helium quantity, large amounts of helium remained. Cyclic venting appeared to be more effective. Three vent cycles were sufficient to reduce the helium to small (less than 0.2%) quantities. Two vent cycles may be sufficient since once the tank has been brought up to pressure after the second vent cycle the helium concentration has been reduced to the less than 0.2% level. The re-pressurization process seemed to contribute to diluting helium. This is as expected since in order to raise the pressure liquid oxygen must be evaporated. Estimated liquid oxygen loss is on the order of 82 pounds (assuming the third vent cycle is not required).

Chato, David J.↗

Analyzers Measure Greenhouse Gases, Airborne Pollutants

In complete darkness, a NASA observatory waits. When an eruption of boiling water billows from a nearby crack in the ground, the observatory s sensors seek particles in the fluid, measure shifts in carbon isotopes, and analyze samples for biological signatures. NASA has landed the observatory in this remote location, far removed from air and sunlight, to find life unlike any that scientists have ever seen. It might sound like a scene from a distant planet, but this NASA mission is actually exploring an ocean floor right here on Earth. NASA established a formal exobiology program in 1960, which expanded into the present-day Astrobiology Program. The program, which celebrated its 50th anniversary in 2010, not only explores the possibility of life elsewhere in the universe, but also examines how life begins and evolves, and what the future may hold for life on Earth and other planets. Answers to these questions may be found not only by launching rockets skyward, but by sending probes in the opposite direction. Research here on Earth can revise prevailing concepts of life and biochemistry and point to the possibilities for life on other planets, as was demonstrated in December 2010, when NASA researchers discovered microbes in Mono Lake in California that subsist and reproduce using arsenic, a toxic chemical. The Mono Lake discovery may be the first of many that could reveal possible models for extraterrestrial life. One primary area of interest for NASA astrobiologists lies with the hydrothermal vents on the ocean floor. These vents expel jets of water heated and enriched with chemicals from off-gassing magma below the Earth s crust. Also potentially within the vents: microbes that, like the Mono Lake microorganisms, defy the common characteristics of life on Earth. Basically all organisms on our planet generate energy through the Krebs Cycle, explains Mike Flynn, research scientist at NASA s Ames Research Center. This metabolic process breaks down sugars for energy to fuel cellular functions. "We think this chemical process did not exist when life first formed on Earth," he says, "because it is based on oxygen being available, and there was little oxygen available on the early Earth." It is possible that there are anaerobic regions beneath the sea floor in which life forms like those early non-Krebs Cycle microbes may yet exist. To detect and potentially collect samples of life emerging from hydrothermal vents, Flynn and his colleagues created Medusa, a multi-sensor instrument designed for long-term observation of diked vents on the ocean floor. When the vents erupt, Medusa assesses indicators of life within the expelled water. If the results are positive, the observatory collects samples and detaches from the ocean floor, making the long journey to the surface for retrieval by scientists. One of the indicators Medusa measures is the ratio of carbon isotopes in the water, namely carbon-12 and carbon-13. Living organisms preferentially take up carbon-12, Flynn says, so examining the ratio of these isotopes can help to determine the source of carbon in an environment as either biological or non-biological. "On Mars, there is evidence of localized methane in the atmosphere, and that methane could come from biological sources or from geochemical ones," Flynn says. "Determining the background planetary carbon isotope ratios and then evaluating the specific carbon ratios in this methane would help to determine how it was formed." A long-duration observatory similar to Medusa could one day provide essential evidence for or against the presence of life on the Red Planet or beneath the ice-crusted oceans of Europa.

Source record↗

ISS External Microorganisms: A Payload to Close Planetary Protection Knowledge Gaps for Crewed Missions

Before NASA or COSPAR is able to set planetary protection requirements for crewed missions to locations like Mars there are a number of critical knowledge gaps that must be addressed (1). One of the most important knowledge gaps is an understanding of microbial leakage from crewed habitats and space suits. Current ECLSS (Environmental Control and Life Support System) and PLSS (Portable Life Support System) requirements do not include any provisions to control microbes that may escape along with vented or leaked gasses. The current generation of NASA space suits can leak at rates as high as 100 cm2 /min. during nominal operation (2). ISS (International Space Station) intentionally vents atmospheric gases like CO2 to maintain habitable conditions for the crew. Furthermore, every time an airlock is used for EVA (extravehicular activity)there is an accompanying release of internal atmosphere. Since it is not possible to sterilize a crewed mission, it is important that we understand what if any microbes are entrained in these vented and leaked products. It is also important to understand if these microbes can survive on exterior surfaces. Recent sampling of the Russian segments of ISS suggest that bacteria and fungi from inside ISS may be capable of surviving on external surfaces(3). NASA is developing an aseptic sampling tool for use during EVA and plans to collect samples from vents on ISS to build on these results. The results of this work will be used to develop planetary protection requirements for vented and leaked gasses from crewed volumes. NASA has developed and tested a tool kit for collecting microbiological samples during EVA(4). This tool kit contains eight commercially available, 23 mm. diameter, foam swabs that can be used to aseptically collect samples while at vacuum. The swabs are individually housed in aluminum canisters that are equipped with 0.2 μm Teflon filters. These filters allow the canisters to equilibrate to pressure changes while preventing microbiological contamination. The canisters will be cleaned and sterilized before flight. Results from ground-based testing indicate that this tool kit is capable of aseptically collecting microbes while at vacuum without becoming contaminated during pressure changes(5). Based on the results of this ground testing we have modified the tool kit to meet NASA safety requirements and improve the ergonomics. We added additional mounting points to the tool kit to give astronauts more options for securing it during use. We also changed the opening mechanism to improve the precision with which swabs can be extracted from the tool kit. We plan to use this kit on an upcoming EVA to collect samples from non-propulsive vents and areas near the U.S. airlock on ISS. These samples will be frozen at -80 ̊C and stored on station until they can be returned to Earth. We will analyze these returned samples using next generation DNA sequencing to determine the community composition and function of external ISS environments. The results of this study will close planetary protection knowledge gaps for crewed missions and will help NASA determine appropriate planetary protection requirements for life support systems. The tool kit will also be useful for collecting aseptic samples on upcoming crewed or robotic missions and could easily be modified to collect samples with organic contamination control requirements as well.

A B Regberg↗

ISS External Microorganisms: A Payload to Close Planetary Protection Knowledge Gaps for Crewed Missions

Before NASA or COSPAR is able to set planetary protection requirements for crewed missions to locations like Mars there are a number of critical knowledge gaps that must be addressed (1). One of the most important knowledge gaps is an understanding of microbial leakage from crewed habitats and space suits. Current ECLSS (Environmental Control and Life Support System) and PLSS (Portable Life Support System) requirements do not include any provisions to control microbes that may escape along with vented or leaked gasses. The current generation of NASA space suits can leak at rates as high as 100 cm2 /min. during nominal operation (2). ISS (International Space Station) intentionally vents atmospheric gases like CO2 to maintain habitable conditions for the crew. Furthermore, every time an airlock is used for EVA (extravehicular activity)there is an accompanying release of internal atmosphere. Since it is not possible to sterilize a crewed mission, it is important that we understand what if any microbes are entrained in these vented and leaked products. It is also important to understand if these microbes can survive on exterior surfaces. Recent sampling of the Russian segments of ISS suggest that bacteria and fungi from inside ISS may be capable of surviving on external surfaces(3). NASA is developing an aseptic sampling tool for use during EVA and plans to collect samples from vents on ISS to build on these results. The results of this work will be used to develop planetary protection requirements for vented and leaked gasses from crewed volumes. NASA has developed and tested a tool kit for collecting microbiological samples during EVA(4). This tool kit contains eight commercially available, 23 mm. diameter, foam swabs that can be used to aseptically collect samples while at vacuum. The swabs are individually housed in aluminum canisters that are equipped with 0.2 μm Teflon filters. These filters allow the canisters to equilibrate to pressure changes while preventing microbiological contamination. The canisters will be cleaned and sterilized before flight. Results from ground-based testing indicate that this tool kit is capable of aseptically collecting microbes while at vacuum without becoming contaminated during pressure changes(5). Based on the results of this ground testing we have modified the tool kit to meet NASA safety requirements and improve the ergonomics. We added additional mounting points to the tool kit to give astronauts more options for securing it during use. We also changed the opening mechanism to improve the precision with which swabs can be extracted from the tool kit. We plan to use this kit on an upcoming EVA to collect samples from non-propulsive vents and areas near the U.S. airlock on ISS. These samples will be frozen at -80 ̊C and stored on station until they can be returned to Earth. We will analyze these returned samples using next generation DNA sequencing to determine the community composition and function of external ISS environments. The results of this study will close planetary protection knowledge gaps for crewed missions and will help NASA determine appropriate planetary protection requirements for life support systems. The tool kit will also be useful for collecting aseptic samples on upcoming crewed or robotic missions and could easily be modified to collect samples with organic contamination control requirements as well.

A B Regberg↗

Planar high density sodium battery

A method of making a molten sodium battery is disclosed. A first metallic interconnect frame having a first interconnect vent hole is provided. A second metallic interconnect frame having a second interconnect vent hole is also provided. An electrolyte plate having a cathode vent hole and an anode vent hole is interposed between the metallic interconnect frames. The metallic interconnect frames and the electrolyte plate are sealed thereby forming gaseous communication between an anode chamber through the anode vent hole and gaseous communication between a cathode chamber through the cathode vent hole.

25 ENERGY STORAGE↗

Recovery of Natural Gas Equipment Emissions into Gas Compression Engines for the Reduction of Potential Greenhouse Gas Emissions

Since the turn of the millennium, the United States (U.S.) oil and natural gas (ONG) industry has nearly doubled its natural gas production rate. As a result, the ONG industry has recently come under increasing scrutiny for its contributions to greenhouse gas (GHG) emissions. Consequently, various solutions to this problem have been proposed and formulated to reduce the impacts of GHG emissions on the environment. West Virginia University (WVU) have found it important to research the impacts of recovering vented gas streams into prime-mover engines. The U.S. Department of Energy (DOE) and National Energy Technology Laboratory (NETL) have granted WVU funding to research and develop a “Methane Mitigator” (M2) - a “Scalable Vent Mitigation Strategy to Simultaneously Reduce Methane Emissions and Fuel Consumption from the Compression Industry.” One of the main areas of interest for this research was the collection of emissions from natural gas equipment into a Caterpillar G3508J natural gas compression engine. The parameters being analyzed from the engine were brake-specific emissions and power output. The emissions sources considered for this research were pneumatic controllers (PCs), reciprocating compressor vents, and the engine’s open crankcase breather. The compressor vent and PC emissions were simulated using a mass flow controller (MFC) and flowed into the engine using two separate methods: (1) directly into the air intake, and (2) through a retrofitted closed crankcase ventilation system (CCV), serving as a buffer volume. The crankcase emissions were quantified without the CCV, and the impact on exhaust emissions from circulating the crankcase gases into the intake was measured. The simulated compressor vent and PC flows from the MFC had limited effect on the steady state operation of the engine and resulting performance. When the simulated flows were fed directly into the engine’s air intake, the changes within the engine’s continuous performance and emission parameters were larger but lasted for shorter durations. Conversely, when the simulated flows were fed into the CCV before entering the air intake, the changes in the engine’s performance and emission parameters were less pronounced for continuous analysis but lasted for longer durations. In either case, the continuous emission changes in both emissions and performance varied in size depending on the test scenario being run, but the cycle average changes in emissions and performance showed little impact overall compared to the engine’s baseline operation. As a result, the inclusion of a CCV shows a decrease in baseline carbon dioxide equivalent (CO2-eq.) engine emissions (from combined exhaust and open crankcase) of almost 4%. Likewise, the CCV inclusion reduced baseline total methane (CH4) from combined exhaust and open crankcase by upwards of 16%. These atmospheric emissions only decreased further with the inclusions of collected PC and compressor vent flows. The resulting changes in time-averaged rated exhaust behavior (or lack thereof) prove that the proposed M2 system could likely be deployed at sites with modern lean-burn natural gas engines as a viable option for reducing and eliminating potential GHG sources that would have otherwise been unutilized as energy sources.

03 NATURAL GAS↗

Hydrogen Diffusion through Multiple Packaging Layers

For this scenario, hydrogen is generated in a container that is eventually stored within a drum or some type of long range storage container. When preparing for long-term storage, the hydrogen container (HC) is placed in a plastic bag (PB1). The PB1 is then placed inside an inner drum (ID). The ID is placed inside a plastic bag (PB2) which is then placed within an outer drum (OD). One or more ODs are then storage is a large container (LC). Filtered vents or vent holes are located on all the container barriers to prevent pressurization and allow gases to flow in and out of the HC. The LC is vented to the atmosphere with four vent paths for this example. The source of hydrogen generation for this study is not important. Any source that generates hydrogen in elemental form (i.e., H{sub 2}) is a candidate for the purposes of this generic evaluation. The released hydrogen accumulates inside the waste packaging. Depending on the permeability of the packaging layers, some of the accumulated hydrogen may diffuse out of the packaging layers and into the space surrounding the drums. Since the drums are confined in the LC, the hydrogen accumulates in the LC as it did inside the drums if venting of the LC does not occur. If accumulation in the LC is allowed without venting, the confinement is eventually breached or the hydrogen is consumed by reaction with other chemical species. One possible reaction is combustion with oxygen. Such a reaction can be explosive, and from this possibility arises the safety concern.

08 HYDROGEN↗

Ash production and dispersal from sustained low-intensity Mono-Inyo eruptions

Recent rhyolitic volcanism has demonstrated that prolonged low-intensity ash venting may accompany effusive dome formation. In this work, we examine the possibility and some consequences of episodes of extended, weak ash venting at the rhyolitic Mono-Inyo chain in Eastern California. We describe ash-filled cracks within one of the youngest domes, Panum Crater, which provide a textural record of ash venting during dome effusion. We use synchrotron-based X-ray computed tomography to characterize the particles in these tuffisites. Particle sizes in well-sorted tuffisite layers agree well with grain size distributions observed during weak ash venting at Soufrière Hills Volcano, Montserrat, and yield approximate upper and lower bounds on gas velocity and mass flux during the formation of those layers. We simulate ash dispersal with Ash3d to assess the consequences of long-lived Mono-Inyo ash venting for ash deposition and the accompanying volcanic hazards. Finally, our results highlight the sensitivity of large-scale outcomes of volcanic eruptions to small-scale processes.

54 ENVIRONMENTAL SCIENCES↗

Behavior of Ullage Bubbles During Blowdown in Low-g Experiment (BUBBLE): Overview of a Cryogenic Tank Depressurization Test

Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.

tank venting↗

Volatile aldehyde emissions from “sub-ohm” vaping devices

"Sub-ohm" atomizers with reduced resistance can deliver more power than conventional electronic cigarettes. Typical battery outputs are 100 watts or more. These devices are particularly popular among young users, and can be a significant source of volatile carbonyls in the indoor environment. Emissions from next-generation sub-ohm vaping products were characterized by determining e-liquid consumption and volatile aldehydes emissions for several combinations of popular high-power configurations. Tests explored the effect of dilution air flow (air vent opening), puffing volume, and coil assembly configuration. The mass of liquid consumed per puff increased as the puff volume increased from 50 to 100 mL, then remained relatively constant for larger puff volumes up to 500 mL. This is likely due to mass transfer limitations at the wick and coil assembly, which reduced the vaporization rate at higher puff volumes. Carbonyl emission rates were systematically evaluated using a 0.15 Ω dual coil atomizer as a function of the puffing volume and dilution air flow, adjusted by setting the air vents to either 100% (fully open), 50%, 25%, or 0% (closed). The highest formaldehyde emissions were observed for the lowest puff volume (50 mL) when the vents 31 were closed (48 ng mg-1), opened at 25% (39 ng mg -1 ) and at 50% (32 ng mg -1 ).. By contrast, 50-mL puffs with 100% open vents, and puff volumes >100 mL for any vent aperture, generated formaldehyde yields of 20 ng mg -1 or lower, suggesting that a significant cooling effect resulted in limited carbonyl formation. Considering the effect of the coil resistance when operated at a voltage of 3.8 V, the amount of liquid evaporated per puff decreased as the resistance increased, in the order of 0.15 Ω > 0.25 Ω > 0.6 Ω consistent with decreasing aerosol temperatures measured at the mouthpiece. Three different configurations of 0.15 Ω coils (dual, quadruple and octuple) were evaluated, observing significant variability. No clear trend was found between carbonyl emission rates and coil resistance or configuration, with highest emissions corresponding to a 0.25 Ω dual coil atomizer. Carbonyl emission rates were compared with those determined using the same methodology for conventional e-cigarettes (lower power tank systems), observing overall lower yields for the sub-ohm devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗