Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ultrasonic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

NONDESTRUCTIVE DETECTION OF DELAMINATION IN THERMAL BARRIER COATINGS USING ULTRASONIC TECHNIQUE

Nondestructive testing using an acousto-ultrasonic technique has been utilized to detect the change of material properties and provide early warning of failure of thermal barrier coating (TBC) systems. Testing was performed on René N5 and Haynes 230 coupons with an applied NETL-bond coat, as well as on coupons containing both an applied MCrAlY bond coat and 7-YSZ top coat. The coupons were subjected to either cyclic or isothermal testing at 1100ºC. Ultrasonic testing was performed before and after thermal testing using piezoelectric sensors with dry contact on the surface of the coatings. Proof-of-concept test results indicated that changes in the properties of the 40m bond coat can be detected using the proposed technique. Waveforms generated via Pitch/Catch indicated minor changes within the bond coat applied to René N5 substrate after 400500 hours of cyclic oxidation at 1100°C. In contrast, marked differences in waveforms and travel time reflected significant crack formation and spallation of the bond coat from the Haynes 230 substrate. Finite element analysis (FEA) simulation of the wave propagation on a simplified TBC system with nonlinear effects was conducted. FEA results clearly show detection of a small embedded void incorporated to simulate delamination. Comparisons between experimental measurements and finite element simulations were used to estimate the material properties of the coatings and the substrate.

36 MATERIALS SCIENCE↗

Improvements in Low-Frequency, Ultrasonic Phased-Array Evaluation for Thick Section Cast Austenitic Stainless Steel Piping Components

Research is being conducted for the U.S. Nuclear Regulatory Commission (NRC) at the Pacific Northwest National Laboratory (PNNL) to assess the effectiveness and reliability of advanced nondestructive examination (NDE) methods for the inspection of light water reactor (LWR) components. A primary objective of this work is to evaluate various NDE methods to assess their ability to detect, localize, and size cracks in coarse-grained steel components. This particular study focused on the evaluation of custom-designed, low-frequency (500 kHz) phased-array (PA) probes for examining welds in thick-section cast austenitic stainless steel (CASS) piping. In addition, research was conducted to observe ultrasonic sound field propagation effects from known coarse-grained microstructures found in parent CASS material. The study was conducted on a variety of thick-wall, coarse-grained CASS specimens that were previously inspected by an older generation 500-kHz PA-UT probe and acquisition instrument configuration. This comparative study describes the impact of the new PA probe design on flaw detection and sizing in a low signal-to-noise environment. The set of Pressurized Water Reactor Owners Group (PWROG) CASS specimens examined in this study are greater than 50.8-mm (2.0-in.) thick with documented flaws and microstructures. These specimens are on loan to PNNL from the Electric Power Research Institute (EPRI) NDE Center in Charlotte, North Carolina. The flaws contained within these specimens are thermal fatigue cracks (TFC) or mechanical fatigue cracks (MFC) and range from 13% to 42% in through-wall extent. In addition, ultrasonic signal continuity was evaluated on two CASS parent material ring sections by examining the edge-of-pipe response (corner geometry) for regions of signal loss.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Insights Gained from Ultrasonic Testing of Piping Welds Subjected to the Mechanical Stress Improvement Process

Pacific Northwest National Laboratory (PNNL) is assisting the United States Nuclear Regulatory Commission (NRC) in developing a position on the management of primary water stress corrosion cracking (PWSCC) in leak-before-break piping systems. Part of this involves determining whether inspections alone, or inspections plus mitigation, are needed. This work addresses the reliability of ultrasonic testing (UT) of cracks that have been mitigated by the mechanical stress improvement process (MSIP). The MSIP has been approved by the NRC (NUREG-0313) since 1986 and modifies residual stresses remaining after welding with compressive, or neutral, stresses near the inner diameter surface of the pipe. This compressive stress is thought to arrest existing cracks and inhibit new crack formation. To evaluate the effectiveness of the MSIP and the reliability of ultrasonic inspections, flaws were evaluated both before and after MSIP application. An initial investigation was based on data acquired from cracked areas in 325-mm-diameter piping at the Ignalina Nuclear Power Plant (INPP) in Lithuania. In a follow-on exercise, PNNL acquired and evaluated similar UT data from a dissimilar metal weld (DMW) specimen containing implanted thermal fatigue cracks. The DMW specimen is a carbon steel nozzle-to-safe end-to-stainless steel pipe section that simulates a pressurizer surge nozzle. The flaws were implanted in the nozzle-to-safe end Alloy 82/182 butter region. Results are presented on the effects of MSIP on specimen surfaces, and on UT flaw responses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Beta-Stabilized Ti-5Al-5Mo-5V-3Cr Primary and Secondary Phase Characterization using Ultrasonic Attenuation

Ti-5Al-5Mo-5V-3Cr (Ti-5553) is a beta-stabilized titanium alloy being evaluated for its use in additive manufacturing. The development of effective nondestructive characterization tools will be critical for successful insertion of Ti-5553 into applications. The microstructure of Ti-5553 can be modified significantly, through heat treatments alone, to produce single β-phase microstructure or dual α-β microstructure with variations on the types and quantities of the α phase in a β matrix. In this work, a set of heat treatments was chosen to obtain a range of microstructures, followed by an investigation of the ultrasonic response to gauge the degree to which these variations could be detected. Ultrasonic attenuation was selected because of its ability to detect differences in grain size and, potentially, the existence and limited details of secondary phases . Initial results show a very distinctive difference in attenuation between the single phase β and the α+β microstructures, and smaller, but still significant, differences among the α+β microstructures indicating that this approach merits further development.

ultrasonic attenuation, Ti-5Al-5Mo-5V-3Cr, heat tr↗

Room-temperature Synthesis of High-entropy Perovskite Oxide Nanoparticle Catalysts via Ultrasonication-based Method

Currently, a sonochemical-based technique for one-pot synthesis of entropy-stabilized perovskite oxide nanoparticle catalysts with high surface area is reported. The high-entropy perovskite oxides were synthesized as monodispersed, spherical nanoparticles with average crystallite size of ~5.9 nm. Taking advantage of the acoustic cavitation phenomenon in ultrasonication process, the nanoparticles of BaSr(ZrHfTi)O 3 , BaSrBi(ZrHfTiFe)O 3 and Ru/BaSrBi(ZrHfTiFe)O 3 were crystallized as single-phase perovskite structures through ultrasonication exposure without calcination. Of utmost importance, the entropically-driven stability of Ru/BaSrBi(ZrHfTiFe)O 3 with excellent dispersion of Ru in the perovskite phase, bestowed the nanoparticles of Ru/BaSrBi(ZrHfTiFe)O 3 with good catalytic activity for CO oxidation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultrasonic Evaluation and Imaging

Ultrasonic evaluation of materials for material characterization and flaw detection is as simple as manually moving a single-element probe across a speci-men and looking at an oscilloscope display in real time or as complex as automatically (under computer control) scanning a phased-array probe across a specimen and collecting encoded data for immediate or off-line data analyses. The reliability of the results in the second technique is greatly increased because of a higher density of measurements per scanned area and measurements that can be more precisely related to the specimen geometry. This chapter will briefly discuss applications of the collection of spatially encoded data and focus primarily on the off-line analyses in the form of data imaging. Pacific Northwest National Laboratory (PNNL) has been involved with as-sessing and advancing the reliability of inservice inspections of nuclear power plant components for over 35 years. Modern ultrasonic imaging techniques such as the synthetic aperture focusing technique (SAFT), phased-array (PA) technolo-gy and sound field mapping have undergone considerable improvements to effec-tively assess and better understand material constraints.

flaw detection↗

Surface engineering to enhance heat generation and joint strength in dissimilar materials AZ31 and DP590 ultrasonic welding

A multiscale simulation approach was developed and employed to optimize the sheet surface conditions for higher interfacial temperature and joint strength in ultrasonic welding of magnesium alloy AZ31 and dual-phase steel DP590. First, a mesoscale model was used to study the relationship between friction coefficient and surface roughness, which can be modified by various engineering methods. Then a macroscopic process model was employed to study the effects of surface roughness on heat generation, indicating that a temperature increase can be achieved with rougher surfaces on two sides of both DP590 and AZ31 sheets. Samples prepared by sanding and filing, as well as grinding, were first characterized for surface roughness and then welded under ultrasonic vibration. An infrared camera was used to measure temperatures in situ for model validation. Overall, lap shear test results for the welded joint showed that the joint strength can be improved by 10~25% using filing and round grinding methods as a result of the enhanced heat generation and mechanical interlocking on the interface.

42 ENGINEERING↗

Microstructure and Properties of Inconel 718 Fabricated by Directed Energy Deposition with In-Situ Ultrasonic Impact Peening

Many inherent issues, such as the detrimental residual stress, columnar grains with anisotropy, and weak mechanical properties, have severely impeded the adoption of metal additive manufacturing (AM) techniques including powder bed fusion and directed energy deposition (DED) processes. In this study, a hybrid AM process that consists of layer-wise laser metal deposition (i.e., a DED process) and in-situ ultrasonic impact peening (UIP) was applied to obtain Inconel 718 superalloy workpieces. Also, for further property enhancement, a post-heat treatment was applied to the deposited material obtained by the hybrid AM process. Scanning electron microscopy and transmission electron microscope were used to investigate the microstructure morphology and reveal the underlying strengthening mechanism. Electron backscatter diffraction was employed to quantitatively study the microstructure resulted from the hybrid AM process and the post-heat treatment. The profile of residual stress along the depth direction was obtained through X-ray diffraction. The results demonstrate that this hybrid AM process is capable of producing high-quality metal parts with significantly refined microstructure, and beneficial compressive residual stress along the depth into surface. Severe plastic strains are introduced by UIP, and the resulted mechanical twinning and dynamic recrystallization play an important role in refining microstructure. The material microstructure is further refined down to 100 µm, and the texture anisotropy is significantly diminished after solution treatment at 980 °C for 1 hour. Under the as-built condition, in-situ ultrasonic peening alters the residual stress component from a tensile state to an overall compressive state with a maximum value of − 190 MPa within the range of measurement depth.

36 MATERIALS SCIENCE↗

Enhanced Surface Properties and Microstructure Evolution of Cr12MoV Using Ultrasonic Surface Rolling Process Combined with Deep Cryogenic Treatment

In this study, the enhanced surface properties and microstructure evolution of quenched and tempered cold work die steel Cr12MoV, which were induced by ultrasonic surface rolling process combined with deep cryogenic treatment (UDCT), were systematically investigated. The results indicated that UDCT had an advantage over conventional ultrasonic surface rolling process (USRP) in improving surface mechanical properties, including smaller surface roughness and smoother machined surface with less cracks and defects; higher surface microindentation hardness with the value of ~ 890 HV (increased by ~ 6.2% compared with USRP); and lower friction coefficient. Such enhancements in surface properties are mainly attributed to the martensitic transformation of retained austenite, the dispersion strengthening of small secondary carbides and the homogenized carbides distribution during UDCT.

36 MATERIALS SCIENCE↗

Rationalization of anisotropic mechanical properties of Al-6061 fabricated using ultrasonic additive manufacturing

Ultrasonic additive manufacturing (UAM) is a solid-state process, which uses ultrasonic vibrations at 20 kHz along with mechanized tape layering and intermittent milling operation, to build fully functional three-dimensional parts. In the literature, UAM builds made with low power (1.5 kW) exhibited poor tensile properties in Z-direction, i.e., normal to the interfaces. This reduction in properties is often attributed to the lack of bonding at faying interfaces. The generality of this conclusion is evaluated further in 6061 aluminum alloy builds made with very high power UAM (9 kW). Tensile deformation behavior along X and Z directions were evaluated with small-scale in-situ mechanical testing equipped with high-resolution digital image correlation, as well as, multi-scale characterization of builds. Interestingly, even with complete metallurgical bonding across the interfaces without any discernable voids, poor Z-direction properties were observed. This reduction is correlated to coalescence of pre-existing shear bands at interfaces into micro voids, leading to strain localization and spontaneous failure on tensile loading.

Digital Image correlation↗

On the efficacy of post-build thermomechanical treatments to improve properties of Zirconium fabricated using ultrasonic additive manufacturing

Here, hot-isostatic pressing has been applied to Zirconium plate fabricated using the ultrasonic additive manufacturing (UAM) technique to enhance interfacial bond quality. Specimens heated to 800 C for 1 h at 100 MPa pressure showed grain growth across many prior foil-to-foil interfaces, thereby increasing foil adhesion. In addition to the material softening induced by a loss of Hall-Petch strengthening, premature failure of specimens loaded parallel to the build direction was observed. Premature specimen failure was attributed to the local delamination at prior foil-to-foil boundaries where grain growth was pinned by Ti impurities introduced during the UAM process via the interaction between a Ti-alloy buffer foil and the welded Zr-foils underneath. In addition, the presence of Ti along select foil interfaces resulted in the nucleation and growth of secondary (Zr,Ti)(Fe,Cr) laves phases during higher-temperature thermomechanical processing. Using a combination of micro-scale X-ray computed tomography, fractography, and in-situ digital image correlation, the effect of defects along prior foil-to-foil boundaries was revealed as delamination-assisted plasticity accelerated specimen failure in preferred tensile orientations. These findings underscore the importance of impurity control when optimizing weld quality of higher-strength material systems using ultrasonic welding.

36 MATERIALS SCIENCE↗

Visualization of hydraulic fracture using physics-informed clustering to process ultrasonic shear waves

Ultrasonic transmission is sensitive to the spatial variation in mechanical properties of materials due to the presence of cracks/fractures. Wave propagation through fractured media introduces changes in the frequency content, travel time and transmission coefficient of the wave. A workflow based on physics-informed unsupervised learning is developed to process the transmitted ultrasonic-shear waveforms to non-invasively visualize the geomechanical alterations due to hydraulic fracturing. Novelty of the work involves the assignment of both statistically consistent and physically consistent clusters to the measurements of shear waveforms acquired across the one axial and two frontal planes. Physically consistent/relevant information is incorporated by considering the travel time of the peak of spectral energy and transmission coefficient of the transmitted waveform. The proposed workflow generates maps of geomechanical alterations across the frontal and axial planes of the sample. The outputs of the workflow are in good agreement with independent techniques viz. acoustic emission and X-ray computed tomography. Finally, the proposed workflow can be adapted for improved fracture characterization in the subsurface when processing sonic-logging, cross-wellbore seismic or surface seismic waveform data.

42 ENGINEERING↗

A Flow-Through Ultrasonic Lysis System for the Disruption of Bacterial Spores

An automated, flow-through spore lysis instrument that is capable of rapidly disrupting bacterial spores is described. The system utilizes a flow-through chamber that allows for direct injection of the sample without the need for a chemical or enzymatic pre-treatment step to soften the spore coat prior to lysis. Lysis of Bacillus subtilis spores, a benign simulant of Bacillus anthracis, is achieved by flowing the sample through a tube whose axis is parallel to the faces of two transducers that deliver 10 W cm-2 to the surface of the tube at 1.4 MHz frequency. Increases in amplifiable DNA were assessed by real-time PCR analysis, which showed at least a 25-fold increase in amplifiable DNA following ultrasonic treatment, and dilution-to-extinction PCR, which suggests up to a 100-1000-fold increase. The modular design of the ultrasonic system and integrated fluidics allow it to be incorporated into multi-step sample treatment and detection systems.

59 BASIC BIOLOGICAL SCIENCES↗

Interface stability of ultrasonic additively manufactured Zircaloy-4 during hydrothermal corrosion

Simulated pressurized water reactor conditions (330 °C, 15.6 MPa, ~20 ppb oxygen) without irradiation were used to investigate the hydrothermal corrosion behavior of ultrasonic additively manufactured Zircaloy-4 up to 1000 h. X-ray computed tomography allowed for visualization of defects from processing and their progression after corrosion experiments. The specimens were found to have clear variability in the mass change data, compared to typical wrought Zircaloy-4 specimens. The variation in the mass change after exposure was attributed to weld defects connected to the specimen surface which allowed ingress of oxidant into the samples. Defects visualized by computed tomography were found via metallography and characterized. In conclusion, ultrasonic additively manufactured Zircaloy-4 was found to have comparable corrosion behavior as wrought Zircaloy-4 for specimens which did not have clear surface defects along weld interfaces.

36 MATERIALS SCIENCE↗

Microstructural characterization and mechanical properties of high power ultrasonic spot welded aluminum alloy AA6111–TiAl6V4 dissimilar joints

Aluminum alloy AA6111 and TiAl6V4 dissimilar alloys were successfully welded by high power ultrasonic spot welding. No visible intermetallic reaction layer was detected in as-welded AA6111/TiAl6V4 welds, even when transmission electron microscopy was used. The effects of welding time and natural aging on peak load and fracture energy were investigated. The peak load and fracture energy of welds increased with an increase in welding time and then reached a plateau. The lap shear strength (peak load) can reach the same level as that of similar Al–Al joints. After natural aging, the fracture mode of welds transferred from ductile fracture of the softened aluminum to interfacial failure due to the strength recovery of AA6111. - Highlights: • Dissimilar Al/Ti welds were produced by high power ultrasonic spot welding. • No visible intermetallic reaction layer was detected on weld interface. • The lap shear strength can reach the same level as that of similar Al–Al joints. • The fracture mode becomes interfacial failure after natural aging.

36 MATERIALS SCIENCE↗

Effect of preheat temperature and post-process treatment on the microstructure and mechanical properties of stainless steel 410 made via ultrasonic additive manufacturing

Ultrasonic additive manufacturing (UAM) is a solid-state manufacturing technology for producing near-net shape metallic parts combining additive ultrasonic metal welding and subtractive machining. Even though UAM has been demonstrated to produce robust metal builds in Al–Al, Al–Ti, Al-steel, Cu–Cu, Al–Cu, and other material systems, UAM welding of high strength steels has proven challenging. This study investigates process and post-processing methods to improve UAM steel weld quality and demonstrates the UAM fabrication of stainless steel 410 (SS 410) builds which possess, after post-processing, mechanical properties comparable with bulk material. Unlike UAM fabrication of softer metals, this study shows that increasing the baseplate temperature from 38°C (100°F) to 204°C (400°F) improves interfacial strength and structural homogeneity of the UAM steel samples. Further improvement in strength is achieved through post-processing. The hot isostatic pressing (HIP) post treatment improves the shear strength of UAM samples to 344 MPa from 154 MPa for as-welded samples. Microstructural analyses with SEM and EBSD show no evidence of body centered cubic (BCC) ferrite to face centered cubic (FCC) austenite transformation taking place during UAM welding of SS 410. The weld quality improvement of UAM steel at higher baseplate temperatures is believed to be caused by the reduction of the yield strength of SS 410 at elevated temperature. Finaly, HIP treatment is shown to increase the overall hardness of UAM SS 410 from 204 ± 7 HV to 240 ± 16 HV due to the formation of local pockets of martensite. Nanohardness tests show that the top of layer n is harder than the bottom of layer n+1 due to grain boundary strengthening.

36 MATERIALS SCIENCE↗

Pressure and Temperature Dependence of the Elasticity of Pyrope-Majorite [Py60Mj40 and Py50Mj50] Garnets Solid Solution Measured by Ultrasonic Interferometry Technique

Compressional (P) and shear (S) wave velocities have been measured for two synthetic polycrystalline specimens of pyrope-majorite garnets [Py60Mj40 and Py50Mj50] by ultrasonic interferometry to 8 GPa and 1000 K, in a DIA-type cubic anvil high pressure apparatus (SAM-85) interfaced with synchrotron X-radiation and X-ray imaging. Elastic bulk (KS) and shear (G) moduli data obtained at the end of the cooling cycles were fitted to functions of Eulerian strain to third order yielding pressure derivatives of the elastic moduli (?KS/?P)T = 4.3 (3); (?G/?P)T = 1.5 (1) for Py60Mj40 garnet and (?KS/?P)T = 4.4 (1); (?G/?P)T = 1.3 (1) for Py50Mj40 garnet. Both (?KS/?P)T and (?G/?P)T are identical for the two garnet compositions and are also consistent with Brillouin scattering data for polycrystalline Py50Mj50. Moreover, the new pressure derivatives of the elastic moduli are equal within experimental uncertainties to those of end-member pyrope garnet from ultrasonic studies.

43 PARTICLE ACCELERATORS↗

Influence of hot isostatic pressing on the performance of aluminum alloy fabricated by ultrasonic additive manufacturing

Ultrasonic additive manufacturing (UAM) is a solid-state manufacturing technique employing principles of ultrasonic welding coupled with mechanized tape layering to fabricate fully functional parts. However, UAM-fabricated parts often exhibit a reduction in strength when loaded normal to the welding interfaces (Z-direction). Here, the effect of hot isostatic pressing (HIP) on UAM builds of aluminum alloy was explored. Tensile testing and microstructure characterization were conducted; it was established that HIP eliminated the brittle Z-direction fracture and improved the strength and ductility of the Z-direction specimens. HIP eliminated voids and produced recrystallized structure; however, welding interfaces survived the HIP treatment.

36 MATERIALS SCIENCE↗