Effect of Surface Pressure Integration Methodology on Launch Vehicle Buffet Forcing Functions

The 2014 test of the Space Launch System (SLS) Rigid Buffet Model conducted at the NASA Langley Transonic Dynamics Tunnel employed an extremely high number of unsteady pressure transducers. The high channel count provided an opportunity to examine the effect of transducer placement on the resulting buffet forcing functions (BFFs). Rings of transducers on the forward half of the model were employed to simulate a single-body vehicle. The impact of transducer density, circumferential distribution, and loss of a single transducer on the resulting BFFs were examined. Rings of transducers on the aft half of the SLS model were employed to examine the effect of transducer density and circumferential distribution on BFFs for a multi-body configuration. Transducer placement considerations with respect to model size, facility infrastructure, and data acquisition system capabilities, which affect the integration process, are also discussed.

Sekula, Martin K.↗

Pressure measurement at low temperatures

The present discussion centers on the following topics: (1) what types of pressure transducers show good potential for cryogenic use; (2) what are the output characteristics (stability, sensitivity, etc.) of a transducer when subjected to low temperature environments; and (3) are methods or apparatus available to calibrate cryogenically pressure transducers under static and dynamic conditions. Some information is available on the low-temperature performance of relatively few pressure transducer types; however, the information is either in the form of manufacturing specifications or unpublished reports. The results of this study clearly indicate that individual transducers, even from the same manufacturer, can exhibit totally different characteristics when subjected to identical cryogenic test procedures. This indicates the necessity of calibrating each transducer for use at low temperature. Also included in the discussion is the description of a static/dynamic low-temperature pressure transducer calibration facility, which is currently being developed.

Arvidson, J. M.↗

Experimental measurement of structural power flow on an aircraft fuselage

An experimental technique is used to measure the structural power flow through an aircraft fuselage with the excitation near the wing attachment location. Because of the large number of measurements required to analyze the whole of an aircraft fuselage, it is necessary that a balance be achieved between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four transducers mounted on a bakelite platform, the structural intensity vectors at locations distributed throughout the fuselage are measured. To minimize the errors associated with using a four transducers technique the measurement positions are selected away from bulkheads and stiffeners. Because four separate transducers are used, with each transducer having its own drive and conditioning amplifiers, phase errors are introduced in the measurements that can be much greater than the phase differences associated with the measurements. To minimize these phase errors two sets of measurements are taken for each position with the orientation of the transducers rotated by 180 deg and an average taken between the two sets of measurements. Results are presented and discussed.

Cuschieri, J. M.↗

Low Differential Pressure Generator

A method and apparatus for evaluating low differential pressure transducers includes a pressure generator in the form of a piston-cylinder assembly having a piston that may be manually positioned precisely within the cylinder to change the volume and thus the pressure at respective sides of the piston. At one side of the piston the cylinder communicates with a first chamber and at the other side of the piston the cylinder communicates with a second chamber, the first and second chambers being formed within a common tank by a partition wall. The chambers each communicate with the transducer to be evaluated and a standard pre-calibrated transducer the transducers being connected fluidly in parallel so that a pressure differential between air in the two chambers resulting from movement of the piston within the cylinder is communicated to both the transducer to be evaluated and the standard transducer, and the outputs of the transducers is observed and recorded.

Stout, Stephen J.↗

Sensor Applications at Kennedy Space Center (KSC)

Transducers used at KSC (Kennedy Space Center), in support of processing and launch of flight vehicles and payloads, are designed and tested to meet specific program requirements. Any equipment, transducer or support instrumentation in direct contact or in support to flight vehicle operations is considered ground support equipment (GSE) and required to meet strict program requirements (i.e. Space Shuttle Program, Space Station Program, Evolved Expendable Launch Vehicles, etc.) Transducers used in KSC applications are based on commercial off-the-shelf (COTS) transducers and sensors. In order to fully meet KSC requirements, these transducers evolve from standard COTS to modified COTS. The Transducer and Data Acquisition Group of the Instrumentation Branch at Kennedy Space Center is responsible for providing the technical expertise as well as qualification-testing capability to transform these COTS transducers in modified COTS suitable for use around flight hardware.

Perotti, Jose M.↗

Compliance and Functional Testing of IEEE 1451.1 for NCAP-to-NCAP Communications in a Sensor Network

Distributed control in a networked environment is an irreplaceable feature in systems with remote sensors and actuators. Although distributed control was not originally designed to be networked, usage of off-the-shelf networking technologies has become so prevalent that control systems are desired to have access mechanisms similar to computer networks. However, proprietary transducer interfaces for network communications and distributed control overwhelmingly dominate this industry. Unless the lack of compatibility and interoperability among transducers is resolved, the mature level of access (that computer networking can deliver) will not be achieved in such networked distributed control systems. Standardization of networked transducer interfaces will enable devices from different manufacturers to talk to each other and ensure their plug-and-play capability. One such standard is the suite of IEEE 1451 for sensor network communication and transducer interfaces. The suite not only provides a standard interface for smart transducers, but also outlines the connection of an NCAP (network capable application processor) and transducers (through a transducer interface module TIM). This paper presents the design of the compliance testing of IEEE 1451.1 (referred to as Dot1) compatible NCAP-to-NCAP communications on a link-layer independent medium. The paper also represents the first demonstration of NCAP-to-NCAP communications with Dot1 compatibility: a tester NCAP and an NCAP under test (NUT).

Figueroa, Jorge↗

Ultrasonic bone densitometer

A device, for measuring the density of a bone structure so as to monitor the calcium content, is described. A pair of opposed spaced ultrasonic transducers are held within a clamping apparatus closely adjacent the bone being analyzed. These ultrasonic transducers incude piezoelectric crystals shaped to direct signals through the bone encompassed in the heel and finger of the subject being tested. A pulse generator is coupled to one of the transducers and generates an electric pulse for causing the transducers to generate an ultrasonic sound wave which is directed through the bone structure to the other transducer. An electric circuit, including an amplifier and a bandpass filter couples the signals from the receiver transducer back to the pulse generator for retriggering the pulse generator at a frequency proportional to the duration that the ultrasonic wave takes to travel through the bone structure being examined.

Hoop, J. M.↗

Surface acoustic wave stabilized oscillators: Additional aging results

Updated aging data for SAW oscillators with aluminum transducers on ST-cut quartz, for gold transducers on ST-cut quartz, and for aluminum transducers on SiO2/LiTaO3. Devices with gold transducers age differently (both and shape of curve) from those having a aluminum transducers indicating the transducer metallization can represent an important aging mechanism.

Source record↗

Effects of material inhomogeneities on ultrasonic measurements - The problem and a solution

Most ultrasonic measurements of materials involve the generation of an acoustic wave and the propagation of that wave from a transducer through a coupling medium to a specimen under test. After interacting with the specimen, the wave propagates through the coupling medium to a receiving transducer and is converted to an electrical signal. The information presented to the observer by the electrical signal depends on each element of the system. In this paper, the role that the receiving transducer plays in ultrasonic measurements is examined. The phase-sensitive nature of conventional receiving transducers has, for the most part, been neglected in nondestructive evaluations. This is shown to lead to significant data misinterpretation. A new acoustoelectric transducer (AET) has been developed which is phase insensitive. Comparative data obtained with both conventional and AET transducers are presented and discussed. The AET is shown to produce more accurate measurements for the cases investigated.

Heyman, J. S.↗

Real time pressure signal system for a rotary engine

A real-time IMEP signal which is a composite of those produced in any one chamber of a three-lobed rotary engine is developed by processing the signals of four transducers positioned in a Wankel engine housing such that the rotor overlaps two of the transducers for a brief period during each cycle. During the overlap period of any two transducers, their output is compared and sampled for 10 microseconds per 0.18 degree of rotation by a sampling switch and capacitive circuit. When the switch is closed, the instantaneous difference between the value of the transducer signals is provided while with the switch open the average difference is produced. This combined signal, along with the original signal of the second transducer, is fed through a multiplexer to a pressure output terminal. Timing circuits, controlled by a crank angle encoder on the engine, determine which compared transducer signals are applied to the output terminal and when, as well as the open and closed periods of the switches.

Rice, W. J.↗

Experimental measurement of structural power flow on an aircraft fuselage

An experimental technique is used to measure structural intensity through an aircraft fuselage with an excitation load applied near one of the wing attachment locations. The fuselage is a relatively large structure, requiring a large number of measurement locations to analyze the whole of the structure. For the measurement of structural intensity, multiple point measurements are necessary at every location of interest. A tradeoff is therefore required between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four transducers mounted on a bakelite platform, structural intensity vectors are measured at locations distributed throughout the fuselage. To minimize the errors associated with using the four transducer technique, the measurement locations are selected to be away from bulkheads and stiffeners. Furthermore, to eliminate phase errors between the four transducer measurements, two sets of data are collected for each position, with the orientation of the platform with the four transducers rotated by 180 degrees and an average taken between the two sets of data. The results of these measurements together with a discussion of the suitability of the approach for measuring structural intensity on a real structure are presented.

Cuschieri, J. M.↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer. respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Kline-Schoder, Robert↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting. distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receive, the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

An IEEE 1451.1 Architecture for ISHM Applications

The IEEE 1451.1 Standard for a Smart Transducer Interface defines a common network information model for connecting and managing smart elements in control and data acquisition networks using network-capable application processors (NCAPs). The Standard is a network-neutral design model that is easily ported across operating systems and physical networks for implementing complex acquisition and control applications by simply plugging in the appropriate network level drivers. To simplify configuration and tracking of transducer and actuator details, the family of 1451 standards defines a Transducer Electronic Data Sheet (TEDS) that is associated with each physical element. The TEDS contains all of the pertinent information about the physical operations of a transducer (such as operating regions, calibration tables, and manufacturer information), which the NCAP uses to configure the system to support a specific transducer. The Integrated Systems Health Management (ISHM) group at NASA's John C. Stennis Space Center (SSC) has been developing an ISHM architecture that utilizes IEEE 1451.1 as the primary configuration and data acquisition mechanism for managing and collecting information from a network of distributed intelligent sensing elements. This work has involved collaboration with other NASA centers, universities and aerospace industries to develop IEEE 1451.1 compliant sensors and interfaces tailored to support health assessment of complex systems. This paper and presentation describe the development and implementation of an interface for the configuration, management and communication of data, information and knowledge generated by a distributed system of IEEE 1451.1 intelligent elements monitoring a rocket engine test system. In this context, an intelligent element is defined as one incorporating support for the IEEE 1451.x standards and additional ISHM functions. Our implementation supports real-time collection of both measurement data (raw ADC counts and converted engineering units) and health statistics produced by each intelligent element. The handling of configuration, calibration and health information is automated by using the TEDS in combination with other electronic data sheets extensions to convey health parameters. By integrating the IEEE 1451.1 Standard for a Smart Transducer Interface with ISHM technologies, each element within a complex system becomes a highly flexible computation engine capable of self-validation and performing other measures of the quality of information it is producing.

Morris, Jon A.↗

Bubble measuring instrument and method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Kline-Schoder, Robert↗

High-Performance Scanning Acousto-Ultrasonic System

A high-performance scanning acousto-ultrasonic system, now undergoing development, is designed to afford enhanced capabilities for imaging microstructural features, including flaws, inside plate specimens of materials. The system is expected to be especially helpful in analyzing defects that contribute to failures in polymer- and ceramic-matrix composite materials, which are difficult to characterize by conventional scanning ultrasonic techniques and other conventional nondestructive testing techniques. Selected aspects of the acousto-ultrasonic method have been described in several NASA Tech Briefs articles in recent years. Summarizing briefly: The acousto-ultrasonic method involves the use of an apparatus like the one depicted in the figure (or an apparatus of similar functionality). Pulses are excited at one location on a surface of a plate specimen by use of a broadband transmitting ultrasonic transducer. The stress waves associated with these pulses propagate along the specimen to a receiving transducer at a different location on the same surface. Along the way, the stress waves interact with the microstructure and flaws present between the transducers. The received signal is analyzed to evaluate the microstructure and flaws. The specific variant of the acousto-ultrasonic method implemented in the present developmental system goes beyond the basic principle described above to include the following major additional features: Computer-controlled motorized translation stages are used to automatically position the transducers at specified locations. Scanning is performed in the sense that the measurement, data-acquisition, and data-analysis processes are repeated at different specified transducer locations in an array that spans the specimen surface (or a specified portion of the surface). A pneumatic actuator with a load cell is used to apply a controlled contact force. In analyzing the measurement data for each pair of transducer locations in the scan, the total (multimode) acousto-ultrasonic response of the specimen is utilized. The analysis is performed by custom software that extracts parameters of signals in the time and frequency domains. The computer hardware and software provide both real-time and postscan processing and display options. For example, oscilloscope displays of waveforms and power spectral densities are available in real time. Images can be computed while scanning continues. Signals can be digitally preprocessed and/or post-processed by filtering, windowing, time-segmenting, and running-waveform-averaging algorithms. In addition, the software affords options for off-line simulation of the waveform-data-acquisition and scanning processes. In tests, the system has been shown to be capable of characterizing microstructural changes and defects in SiC/SiC and C/SiC ceramic-matrix composites. Delaminations, variations in density, microstructural changes attributable to infiltration by silicon, and crack-space indications (defined in the next sentence) have been revealed in images formed from several time- and frequency-domain parameters of scanning acousto-ultrasonic signals. The crack-space indications were image features that were not revealed by other nondestructive testing methods and are so named because they turned out to mark locations where cracking eventually occurred.

Roth, Don↗