Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Nanoparticles as contrast-enhancing agents in optical coherence tomography imaging of the structural components of skin: Quantitative evaluation

This work examines the effect of gold nanoshells and titania nanoparticles on the imaging contrast of structural components of skin in optical coherence tomography (OCT). Experimental data are compared to Monte Carlo (MC) simulation results. In experiments with pig skin in vivo, the epidermis - dermis contrast is improved from 0.78 {+-} 0.03 to 0.92 {+-} 0.04 by gold nanoshells applied to the skin surface and from 0.78 {+-} 0.03 to 0.86 {+-} 0.04 by titania nanoparticles. The contrast of glands is enhanced by titania from 0.68 {+-} 0.12 to 0.84 {+-} 0.07. The highest contrast is reached 120 - 150 min after applying gold nanoshells and 160 - 200 min after applying titania. According to the MC simulation results, the contrast of inclusions increases from zero to 0.85 and 0.65, respectively. (optical tomography)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Depth-resolved monitoring of diffusion of hyperosmotic agents in normal and malignant human esophagus tissues using optical coherence tomography in-vitro

Depth-resolved monitoring with differentiation and quantification of glucose diffusion in healthy and abnormal esophagus tissues has been studied in vitro. Experiments have been performed using human normal esophagus and esophageal squamous cell carcinoma (ESCC) tissues by the optical coherence tomography (OCT). The images have been continuously acquired for 120 min in the experiments, and the depth-resolved and average permeability coefficients of the 40 % glucose solution have been calculated by the OCT amplitude (OCTA) method. We demonstrate the capability of the OCT technique for depth-resolved monitoring, differentiation, and quantifying of glucose diffusion in normal esophagus and ESCC tissues. It is found that the permeability coefficients of the 40 % glucose solution are not uniform throughout the normal esophagus and ESCC tissues and increase from (3.30 {+-} 0.09) Multiplication-Sign 10{sup -6} and (1.57 {+-} 0.05) Multiplication-Sign 10{sup -5} cm s{sup -1} at the mucous membrane of normal esophagus and ESCC tissues to (1.82 {+-} 0.04) Multiplication-Sign 10{sup -5} and (3.53 {+-} 0.09) Multiplication-Sign 10{sup -5} cm s{sup -1} at the submucous layer approximately 742 {mu}m away from the epithelial surface of normal esophagus and ESCC tissues, respectively. (optical coherence tomography)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators

The method of optical coherence tomography with the scheme of parallel reception of the interference signal (P-OCT) is developed on the basis of spatial paralleling of the reference wave by means of a phase diffraction grating producing the appropriate time delay in the Mach–Zehnder interferometer. The absence of mechanical variation of the optical path difference in the interferometer essentially reduces the time required for 2D imaging of the object internal structure, as compared to the classical OCT that uses the time-domain method of the image construction, the sensitivity and the dynamic range being comparable in both approaches. For the resulting field of the interfering object and reference waves an analytical expression is derived that allows the calculation of the autocorrelation function in the plane of photodetectors. For the first time a method of linear phase modulation by 2π is proposed for P-OCT systems, which allows the use of compact high-frequency (a few hundred kHz) piezoelectric cell-based modulators. For the demonstration of the P-OCT method an experimental setup was created, using which the images of the inner structure of biological objects at the depth up to 1 mm with the axial spatial resolution of 12 μm were obtained. (optical coherence tomography)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional representation of late-arriving photons for detecting inhomogeneities in diffuse optical tomography

A method for rapid detection of absorbing inhomogeneity in a strongly scattering medium having the properties of a biological tissue before the image reconstruction is described based on the principles of diffuse optical tomography. The method is based on preliminary processing of a three-dimensional surface obtained from the set of time-resolved data in the Cartesian coordinate system, followed by its conformal transformation into two surfaces in the cylindrical coordinate system. A specific feature of the method is the use of late-arriving photons, scattered and diffusely transmitted through an optically turbid object. (optical tomography)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical limit of spatial resolution in diffuse optical tomography using a perturbation model

We have assessed the limit of spatial resolution of timedomain diffuse optical tomography (DOT) based on a perturbation reconstruction model. From the viewpoint of the structure reconstruction accuracy, three different approaches to solving the inverse DOT problem are compared. The first approach involves reconstruction of diffuse tomograms from straight lines, the second – from average curvilinear trajectories of photons and the third – from total banana-shaped distributions of photon trajectories. In order to obtain estimates of resolution, we have derived analytical expressions for the point spread function and modulation transfer function, as well as have performed a numerical experiment on reconstruction of rectangular scattering objects with circular absorbing inhomogeneities. It is shown that in passing from reconstruction from straight lines to reconstruction using distributions of photon trajectories we can improve resolution by almost an order of magnitude and exceed the accuracy of reconstruction of multi-step algorithms used in DOT. (optical tomography)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of in vivo and ex vivo laser scanning microscopy and multiphoton tomography application for human and porcine skin imaging

Two state-of-the-art microscopic optical methods, namely, confocal laser scanning microscopy in the fluorescence and reflectance regimes and multiphoton tomography in the autofluorescence and second harmonic generation regimes, are compared for porcine skin ex vivo and healthy human skin in vivo. All skin layers such as stratum corneum (SC), stratum spinosum (SS), stratum basale (SB), papillary dermis (PD) and reticular dermis (RD) as well as transition zones between these skin layers are measured noninvasively at a high resolution, using the above mentioned microscopic methods. In the case of confocal laser scanning microscopy (CLSM), measurements in the fluorescence regime were performed by using a fluorescent dye whose topical application on the surface is well suited for the investigation of superficial SC and characterisation of the skin barrier function. For investigations of deeply located skin layers, such as SS, SB and PD, the fluorescent dye must be injected into the skin, which markedly limits fluorescence measurements using CLSM. In the case of reflection CLSM measurements, the obtained results can be compared to the results of multiphoton tomography (MPT) for all skin layers excluding RD. CLSM cannot distinguish between dermal collagen and elastin measuring their superposition in the RD. By using MPT, it is possible to analyse the collagen and elastin structures separately, which is important for the investigation of anti-aging processes. The resolution of MPT is superior to CLSM. The advantages and limitations of both methods are discussed and the differences and similarities between human and porcine skin are highlighted. (laser biophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring of permeability of different analytes in human normal and cancerous bladder tissues in vitro using optical coherence tomography

We report our preliminary results on quantification of glucose and dimethyl sulfoxide (DMSO) diffusion in normal and cancerous human bladder tissues in vitro by using a spectral domain optical coherence tomography (SD-OCT). The permeability coefficients (PCs) of a 30% aqueous solution of glucose are found to be (7.92 ± 0.81) × 10{sup -6} cm s{sup -1} and (1.19 ± 0.13) × 10{sup -5} cm s{sup -1} in normal and cancerous bladder tissues, respectively. The PCs of 50% DMSO are calculated to be (8.99 ± 0.93) × 10{sup -6} cm s{sup -1} and (1.43 ± 0.17) × 10{sup -5} cm s{sup -1} in normal and cancerous bladder tissues, respectively. The obtained results show a statistically significant difference in permeability of normal and cancerous tissue and indicate that the PC of 50% DMSO is about 1.13-and 1.21-fold higher than that of 30% glucose in normal bladder and cancerous bladder tissues, respectively. Thus, the quantitative measurements with the help of PCs from OCT images can be a potentially powerful method for bladder cancer detection. (optical coherence tomography)

60 APPLIED LIFE SCIENCES↗

Low-coherence terahertz tomography based on spatially separated counterpropagating beams with allowance for probe radiation absorption in the medium

This paper analyses low-coherence tomography of absorbing media with the use of spatially separated counterpropagating object and reference beams. A probe radiation source based on a broadband terahertz (THz) generator that emits sufficiently intense THz waves in the spectral range 90 – 350 μm and a prism spectroscope that separates out eight narrow intervals from this range are proposed for implementing this method. This allows media of interest to be examined by low-coherence tomography with counterpropagating beams in each interval. It is shown that, according to the Rayleigh criterion, the method is capable of resolving inhomogeneities with a size near one quarter of the coherence length of the probe radiation. In addition, the proposed tomograph configuration allows one to determine the average surface asperity slope and the refractive index and absorption coefficient of inhomogeneities 180 to 700 mm in size, and obtain spectra of such inhomogeneities in order to determine their chemical composition. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of haemodilution on the optical properties of blood during coagulation studied by optical coherence tomography

We report an investigation of the effects of blood dilution with hypertonic (7.5 %) and normal (0.9 %) saline on its optical properties during coagulation in vitro using optical coherence tomography. The light penetration depth and attenuation coefficient are obtained from the dependences of reflectance on the depth. Normal whole blood has served as the control group. The average coagulation time is equal to 420±16,418±16 and 358±14 s with blood volume replacement of 2 %, 11 %, and 20 % by 0.9 % normal saline, respectively. With 2 %, 11% and 20% blood volume replacement with 7.5 % hypertonic saline, the average coagulation time is 422±17,1160±45 and 1730±69 s, respectively. For normal whole blood, the average coagulation time amounts to 425±19 s. it is shown that dilution with normal saline has a procoagulant effect when it replaces 20 % of blood volume, and hypertonic saline has an anticoagulant effect if it replaces 11 % or more of blood volume. It is concluded that optical coherence tomography is a potential technique to quantify and monitor the liquid – gel transition during the coagulation process of blood diluted by normal and hypertonic saline. (biophotonics)

60 APPLIED LIFE SCIENCES↗

High-resolution multicontrast tomography with an X-ray microarray anode–structured target source

Multicontrast X-ray imaging with high resolution and sensitivity using Talbot–Lau interferometry (TLI) offers unique imaging capabilities that are important to a wide range of applications, including the study of morphological features with different physical properties in biological specimens. The conventional X-ray TLI approach relies on an absorption grating to create an array of micrometer-sized X-ray sources, posing numerous limitations, including technical challenges associated with grating fabrication for high-energy operations. We overcome these limitations by developing a TLI system with a microarray anode–structured target (MAAST) source. The MAAST features an array of precisely controlled microstructured metal inserts embedded in a diamond substrate. Using this TLI system, tomography of a Drum fish tooth with high resolution and tri-contrast (absorption, phase, and scattering) reveals useful complementary structural information that is inaccessible otherwise. The results highlight the exceptional capability of high-resolution multicontrast X-ray tomography empowered by the MAAST-based TLI method in biomedical applications.

47 OTHER INSTRUMENTATION↗

FIRST THREE-DIMENSIONAL RECONSTRUCTIONS OF CORONAL LOOPS WITH THE STEREO A+B SPACECRAFT. III. INSTANT STEREOSCOPIC TOMOGRAPHY OF ACTIVE REGIONS

Here we develop a novel three-dimensional (3D) reconstruction method of the coronal plasma of an active region by combining stereoscopic triangulation of loops with density and temperature modeling of coronal loops with a filling factor equivalent to tomographic volume rendering. Because this method requires only a stereoscopic image pair in multiple temperature filters, which are sampled within {approx}1 minute with the recent STEREO/EUVI instrument, this method is about four orders of magnitude faster than conventional solar rotation-based tomography. We reconstruct the 3D density and temperature distribution of active region NOAA 10955 by stereoscopic triangulation of 70 loops, which are used as a skeleton for a 3D field interpolation of some 7000 loop components, leading to a 3D model that reproduces the observed fluxes in each stereoscopic image pair with an accuracy of a few percents (of the average flux) in each pixel. With the stereoscopic tomography we infer also a differential emission measure distribution over the entire temperature range of T {approx} 10{sup 4}-10{sup 7}, with predictions for the transition region and hotter corona in soft X-rays. The tomographic 3D model provides also large statistics of physical parameters. We find that the extreme-ultraviolet loops with apex temperatures of T{sub m} {approx}< 3.0 MK tend to be super-hydrostatic, while hotter loops with T{sub m} {approx} 4-7 MK are near-hydrostatic. The new 3D reconstruction model is fully independent of any magnetic field data and is promising for future tests of theoretical magnetic field models and coronal heating models.

99 GENERAL AND MISCELLANEOUS↗

THREE-DIMENSIONAL DOPPLER TOMOGRAPHY OF THE RS VULPECULAE INTERACTING BINARY

Three-dimensional Doppler tomography has been used to study the H{alpha} emission sources in the RS Vulpeculae (RS Vul) interacting binary. The two-dimensional tomogram of this binary suggested that most of the emission arises from the cool mass losing star with additional evidence of a gas stream flowing close to its predicted trajectory. However, the three-dimensional tomogram revealed surprising evidence that the gas stream has an average velocity of -85 km s{sup -1} relative to the central velocity plane at V{sub z} = 0 km s{sup -1}, unlike U CrB in which the stream was prominent along this central plane. These unexpected V{sub z} motions may result from the interaction between magnetic activity on the cool star and the gravitationally induced Roche lobe overflow from that star. Evidence of a loop prominence on the cool star close to the L1 point has been found in the three-dimensional tomogram of RS Vul; hence, the magnetic field lines may have deflected the gas stream relative to the central plane. This result is consistent with earlier detections of RS Vul as both an X-ray and a radio source, and represents the first detection of a loop prominence in an interacting binary based on tomography. Moreover, recent radio images of {beta} Per, the prototype of the Algols, show that the magnetic field of the mass losing star is asymmetric and extends well beyond the orbital plane of the binary, so it is now plausible that the gas flow between the stars in RS Vul could be deflected in an asymmetric way by the magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

Interior soft x-ray tomography with sparse global sampling

To investigate the feasibility of interior imaging reconstruction in soft X-ray tomography for higher-resolution cellular imaging, including whole-cell imaging, we develop an alignment and reconstruction algorithm that combines a small number of sparse whole-cell images with a high-resolution local interior scan. Based on numerical simulations, we demonstrate that combined reconstructions mitigate the depth-of-field limitation in high-resolution scans, enable radiation dose optimization, and yield quantitative X-ray absorption values with sparse sampling. We further validate our numerical approach using experimental data from two different cell types and show that the combined reconstruction reliably provides high spatial resolution within an interior region of interest of a whole cell. The resulting sparse reconstruction framework offers robust, faithful visualization of cellular organelles in soft X-ray tomography. This mesoscale imaging strategy allows one to ‘scout’ and zoom into selected subcellular volumes of interest, enabling increased spatial resolution without sacrificing larger-volume imaging and providing information on the relative positions of all organelles within a cell.

3D imaging↗

Multi-slice electron ptychographic tomography for three-dimensional phase-contrast microscopy beyond the depth of focus limits

Electron ptychography is a powerful computational method for atomic-resolution imaging with high contrast for weakly and strongly scattering elements. Modern algorithms coupled with fast and efficient detectors allow imaging specimens with tens of nanometers thicknesses with sub-0.5 Ångstrom lateral resolution. However, the axial resolution in these approaches is currently limited to a few nanometers, limiting their ability to solve novel atomic structures ab initio. Here, we experimentally demonstrate multi-slice ptychographic electron tomography, which allows atomic resolution three-dimensional phase-contrast imaging in a volume surpassing the depth of field limits. We reconstruct tilt-series 4D-STEM measurements of a $\mathrm{Co_3O_4}$ nanocube, yielding 2 Å axial and 0.7 Å transverse resolution in a reconstructed volume of $\mathrm{(18.2\,nm)^3}$. Our results demonstrate a 13.5-fold improvement in axial resolution compared to multi-slice ptychography while retaining the atomic lateral resolution and the capability to image volumes beyond the depth of field limit. Multi-slice ptychographic electron tomography significantly expands the volume of materials accessible using high-resolution electron microscopy. We discuss further experimental and algorithmic improvements necessary to also resolve single weakly scattering atoms in 3D.

36 MATERIALS SCIENCE↗

Convolutional neural network based non-iterative reconstruction for accelerating neutron tomography *

Abstract Neutron computed tomography (NCT), a 3D non-destructive characterization technique, is carried out at nuclear reactor or spallation neutron source-based user facilities. Because neutrons are not severely attenuated by heavy elements and are sensitive to light elements like hydrogen, neutron radiography and computed tomography offer a complementary contrast to x-ray CT conducted at a synchrotron user facility. However, compared to synchrotron x-ray CT, the acquisition time for an NCT scan can be orders of magnitude higher due to lower source flux, low detector efficiency and the need to collect a large number of projection images for a high-quality reconstruction when using conventional algorithms. As a result of the long scan times for NCT, the number and type of experiments that can be conducted at a user facility is severely restricted. Recently, several deep convolutional neural network (DCNN) based algorithms have been introduced in the context of accelerating CT scans that can enable high quality reconstructions from sparse-view data. In this paper, we introduce DCNN algorithms to obtain high-quality reconstructions from sparse-view and low signal-to-noise ratio NCT data-sets thereby enabling accelerated scans. Our method is based on the supervised learning strategy of training a DCNN to map a low-quality reconstruction from sparse-view data to a higher quality reconstruction. Specifically, we evaluate the performance of two popular DCNN architectures—one based on using patches for training and the other on using the full images for training. We observe that both the DCNN architectures offer improvements in performance over classical multi-layer perceptron as well as conventional CT reconstruction algorithms. Our results illustrate that the DCNN can be a powerful tool to obtain high-quality NCT reconstructions from sparse-view data thereby enabling accelerated NCT scans for increasing user-facility throughput or enabling high-resolution time-resolved NCT scans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Error-mitigated nonorthogonal quantum eigensolver via shadow tomography

We present a shadow-tomography-enhanced nonorthogonal quantum eigensolver (NOQE) for more efficient and accurate electronic structure calculations on near-term quantum devices. By integrating shadow tomography into the NOQE, the measurement cost scales linearly rather than quadratically with the number of reference states, while also reducing the required qubits and circuit depth by half. This approach enables extraction of all matrix elements via randomized measurements and classical postprocessing. We analyze its sample complexity and show that, for small systems, it remains constant in the high-precision regime, while for larger systems, it scales linearly with the system size. We further apply shadow-based error mitigation to suppress noise-induced bias without increasing quantum resources. Demonstrations on the hydrogen molecule in the strongly correlated regime achieve chemical accuracy under realistic noise, showing that our method is both resource-efficient and noise-resilient for practical quantum chemistry simulations in the near term.

quantum algorithms & computation↗

Polychromatic cone-beam phase-contrast tomography

A method is presented for quantitative phase-contrast tomography using unfiltered radiation from a small polychromatic source. The three-dimensional distribution of complex refractive index in a monomorphous object is reconstructed given a single projection image per view angle. The reconstruction algorithm is achromatic and stable with respect to high-spatial-frequency noise, in contrast to conventional tomography. The density distribution in a test sample was accurately reconstructed from polychromatic phase-contrast data collected with a point-projection x-ray microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How accurately can 21 cm tomography constrain cosmology?

There is growing interest in using 3-dimensional neutral hydrogen mapping with the redshifted 21 cm line as a cosmological probe. However, its utility depends on many assumptions. To aid experimental planning and design, we quantify how the precision with which cosmological parameters can be measured depends on a broad range of assumptions, focusing on the 21 cm signal from 6<z<20. We cover assumptions related to modeling of the ionization power spectrum, to the experimental specifications like array layout and detector noise, to uncertainties in the reionization history, and to the level of contamination from astrophysical foregrounds. We derive simple analytic estimates for how various assumptions affect an experiment's sensitivity, and we find that the modeling of reionization is the most important, followed by the array layout. We present an accurate yet robust method for measuring cosmological parameters that exploits the fact that the ionization power spectra are rather smooth functions that can be accurately fit by 7 phenomenological parameters. We find that for future experiments, marginalizing over these nuisance parameters may provide constraints almost as tight on the cosmology as if 21 cm tomography measured the matter power spectrum directly. A future square kilometer array optimized for 21 cm tomography could improve the sensitivity to spatial curvature and neutrino masses by up to 2 orders of magnitude, to {delta}{omega}{sub k}{approx_equal}0.0002 and {delta}m{sub {nu}}{approx_equal}0.007 eV, and give a 4{sigma} detection of the spectral index running predicted by the simplest inflation models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗