Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Li-ion battery thermal runaway suppression system using microchannel coolers and refrigerant injections

A battery management system with thermally integrated fire suppression includes a multiplicity of individual battery cells in a housing; a multiplicity of cooling passages in the housing within or between the multiplicity of individual battery cells; a multiplicity of sensors operably connected to the individual battery cells, the sensors adapted to detect a thermal runaway event related to one or more of the multiplicity of individual battery cells; and a management system adapted to inject coolant into at least one of the multiplicity of cooling passages upon the detection of the thermal runaway event by the any one of the multiplicity of sensors, so that the thermal runaway event is rapidly quenched.

25 ENERGY STORAGE↗

Design and specifications of the diagnostics for the instrumented calorimeter of Source for the Production of Ions of Deuterium Extracted from Radio frequency plasma

In the development of the neutral beam injector for ITER experiment, the test facility SPIDER is going to be built. To measure the beam parameters, several diagnostics are used. One of them is the Short-Time Retractable Instrumented Kalorimeter Experiment (STRIKE) which measures beam uniformity, beamlet divergence, and stripping losses. This contribution gives an overview of the diagnostics dedicated to these measurements: thermal cameras, thermocouples, current sensors, and electrostatic sensors. The specifications of these diagnostics have been defined according to the results of electrostatic and thermal simulations. A failure modes and effects analysis has been performed during the design. Consequently the project of the STRIKE diagnostics has been optimized to reduce the possible failure risks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of High-Resolution Thermal Infrared Remote Sensing and GIS to Assess the Urban Heat Island Effect

Day and night airborne thermal infrared image data at 5 m spatial resolution acquired with the 15-channel (0.45 micron - 12.2 micron) Advanced Thermal and Land Applications Sensor (ATLAS) over Alabama, Huntsville on 7 September, 1994 were used to study changes in the thermal signatures of urban land cover types between day and night. Thermal channel number 13 (9.6 micron - 10.2 micron) data with the best noise-equivalent temperature change (NEAT) of 0.25 C after atmospheric corrections and temperature calibration were selected for use in this analysis. This research also examined the relation between land cover irradiance and vegetation amount, using the Normalized Difference Vegetation Index (NDVI), obtained by ratioing the difference and the sum of the red (channel number 3: 0.60-0.63 micron) and reflected infrared (channel number 6: 0.76-0.90 micron) ATLAS data. Based on the mean radiance values, standard deviations, and NDVI extracted from 351 pairs of polygons of day and night channel number 13 images for the city of Huntsville, a spatial model of warming and cooling characteristics of commercial, residential, agricultural, vegetation, and water features was developed using a GIS approach. There is a strong negative correlation between NDVI and irradiance of residential, agricultural, and vacant/transitional land cover types, indicating that the irradiance of a land cover type is greatly influenced by the amount of vegetation present. The predominance of forests, agricultural, and residential uses associated with varying degrees of tree cover showed great contrasts with commercial and services land cover types in the center of the city, and favors the development of urban heat islands. The high-resolution thermal infrared images match the complexity of the urban environment, and are capable of characterizing accurately the urban land cover types for the spatial modeling of the urban heat island effect using a GIS approach.

Lo, C. P.↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

MEMS terahertz-to-infrared band converter using frequency selective planar metamaterial

A MEMS terahertz-to-infrared converter has been developed based on the unique properties of metamaterials that allow for selective control of the absorptivity and emissivity of the sensors. The converter consists of a sensing element structurally made of planar metamaterial membranes, connected to a substrate frame by four symmetrically-located thermal insulators. Upon THz absorption, the temperature of the sensing element increases and the outward infrared flux from the backside of the element is read by a commercial long-wave infrared camera. Two configurations were designed and fabricated with metamaterial absorptivity optimized for 3.8THz and 4.75THz quantum cascade lasers. The first sensor, fabricated with an oxidized aluminum backside, exhibits higher responsivity, but lower conversion efficiency than the second sensor, fabricated with a metamaterial backside. The spectral characteristics of the metamaterial on the two sides can be optimized to improve both responsivity and sensitivity, while keeping the sensors’ thermal time constant sufficiently small for real time imaging. No dedicated electronics or optics are required for readout making metamaterial-based MEMS THz-to-IR converters very attractive for THz imaging as means of a simple attachment to commercial IR cameras.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of Upper Air, Ground and Remote Sensing Data For the ATLAS Field Campaign in San Juan, Puerto Rico

The Atlas San Juan Mission was conducted in February 2004 with the main objectives of observing the Urban Heat Island of San Juan, providing high resolution data of the land use for El Yunque Rain Forest and for calibrating remote sensors. The mission was coordinated with NASA staff members at Marshall, Stennis, Goddard, and Glenn. The Airborne Thermal and Land Applications Sensor (ATLAS) from NASA/Stennis, that operates in the visual and IR bands, was used as the main sensor and was flown over Puerto Rico in a Lear 23 jet plane. To support the data gathering effort by the ATLAS sensor, remote sensing observations and upper air soundings were conducted along with the deployment of a number of ground based weather stations and temperature sensors. This presentation focuses in the analysis of this complementary data for the Atlas San Juan Mission. Upper air data show that during the days of the mission the Caribbean mid and high atmospheres were relatively dry and highly stable reflecting positive surface lifted index, a necessary condition to conduct this suborbital campaign. Surface wind patterns at levels below 850mb were dominated by the easterly trades, while the jet stream at the edge of the troposphere dominated the westerly wind at levels above 500mb. The jet stream remained at high latitudes reducing the possibility of fronts. In consequence, only 8.4 mm of precipitation were reported during the entire mission. Observation of soundings located about 150 km apart reflected minimum variations of the boundary layer across the island for levels below 850 meters and a uniform atmosphere for higher levels. The weather stations and the temperature sensors were placed at strategic locations to observe variations across the urban and rural landscapes. Time series plot of the stations' data show that heavily urbanized commercial areas have higher air temperatures than urban and suburban residential areas, and much higher temperatures than rural areas. Temperature differences [dT(U-R)] were obtained by subtracting the values of several stations from a reference urban station, located in the commercial area of San Juan. These time series show that the UHI peaks during the morning between 10:00am and noon to an average of 4.5 C, a temporal pattern not previously observed in similar studies for continental cities. It is also observed a high variability of the UHI with the precipitation patterns even for short events. These results may be a reflection of a large land use density by low level buildings with an apparent absence of significant heat storage effects in the urban areas, and the importance of the surrounding soil and vegetation moisture in controlling the urban tropical climate. The ATLAS data was used to determine albedo and surface temperature patterns on a 10m scale for the study area. These data were used to calibrate the spatial distribution of the surface temperature when using remote sensing images from MODIS (Moderate Resolution Imaging Spectroradiometer). Surface temperatures were estimated using the land surface temperature product MOD11_L2 distributed by the Land Process Distributed Active Archive Center (LP DAAC). These results show the maximum, minimum and average temperatures in San Juan and in the entire Island at a resolution of 1 km. The information retrieved from MODIS for land surface temperatures reflected similar temporal and spatial variations as the weather stations and ATLAS measurements with a highest absolute offset of about 5 C due to the differences between surface and air temperatures.

Gonzalez, J. E.↗

Analysis of Upper Air, Ground and Remote Sensing Data for the ATLAS Field Campaign in San Juan, Puerto Rico

The Atlas San Juan Mission was conducted in February 2004 with the main objectives of observing the Urban Heat Island of San Juan, providing high resolution data of the land use for El Yunque Rain Forest and for calibrating remote sensors. The mission was coordinated with NASA staff members at Marsha& Stennis, Goddard, and Glenn. The Airborne Thermal and Land Applications Sensor (ATLAS) from NASA/Stennis, that operates in the visual and IR bands, was used as the main sensor and was flown over Puerto Rico in a Lear 23 jet plane. To support the data gathering effort by the ATLAS sensor, remote sensing observations and upper air soundings were conducted along with the deployment of a number of ground based weather stations and temperature sensors. This presentation focuses in the analysis of this complementary data for the Atlas San Juan Mission. Upper air data show that during the days of the mission the Caribbean mid and high atmospheres were relatively dry and highly stable reflecting positive surface lifted index, a necessary condition to conduct this suborbital campaign. Surface wind patterns at levels below 850mb were dominated by the easterly trades, while the jet stream at the edge of the troposphere dominated the westerly wind at levels above 500mb. The jet stream remained at high latitudes reducing the possibility of fronts. In consequence, only 8.4 mm of precipitation were reported during the entire mission. Observation of soundings located about 150 km apart reflected minimum variations of the boundary layer across the Island for levels below 850 meters and a uniform atmosphere for higher levels. The weather stations and the temperature sensors were placed at strategic locations to observe variations across the urban and rural landscapes. Time series plot of the stations' data show that heavily urbanized commercial areas have higher air temperatures than urban and suburban residential areas, and much higher temperatures than rural areas. Temperature differences [dT(U-R)] were obtained by subtracting the values of several stations h m a reference urban station, located m the commercial area of San Juan. These time series show that the UHI peaks during the morning between 10:00am and noon to an average of 4.5 C, a temporal pattern not previously observed in similar studies for continental cities. It is also observed a high variability of the UHI with the precipitation patterns even for short events. These results may be a reflection of a large land use density by low level buildings with an apparent absence of significant heat storage effects in the urban areas, and the importance of the surrounding soil and vegetation moisture in controlling the urban tropical climate. The ATLAS data was used to determine albedo and surface temperature patterns on a 10m scale for the study area. These data were used to calibrate the spatial distribution of the surface temperature when using remote sensing images from MODIS (Moderate Resolution Imaging Spectradiometer). Surface temperatures were estimated using the land surface temperature product MODII-L2 distributed by the Land Process Distributed Active Archive Center(LP DAAC). These results show the maximum, minimum and average temperatures in San Juan and in the entire Island at a resolution of 1 km. The information retrieved from MODIS for land surface temperatures reflected similar temporal and spatial variations as the weather stations and ATLAS measurements with a highest absolute offset of about 5 C due to the differences between surface and air temperatures.

Gonzalez, Jorge E.↗

3D printed high performance strain sensors for high temperature applications

Realization of high temperature physical measurement sensors, which are needed in many of the current and emerging technologies, is challenging due to the degradation of their electrical stability by drift currents, material oxidation, thermal strain, and creep. In this paper, for the first time, we demonstrate that 3D printed sensors show a metamaterial-like behavior, resulting in superior performance such as high sensitivity, low thermal strain, and enhanced thermal stability. The sensors were fabricated using silver (Ag) nanoparticles (NPs), using an advanced Aerosol Jet based additive printing method followed by thermal sintering. The sensors were tested under cyclic strain up to a temperature of 500 °C and showed a gauge factor of 3.15 ± 0.086, which is about 57% higher than that of those available commercially. The sensor thermal strain was also an order of magnitude lower than that of commercial gages for operation up to a temperature of 500 °C. An analytical model was developed to account for the enhanced performance of such printed sensors based on enhanced lateral contraction of the NP films due to the porosity, a behavior akin to cellular metamaterials. Here, the results demonstrate the potential of 3D printing technology as a pathway to realize highly stable and high-performance sensors for high temperature applications.

47 OTHER INSTRUMENTATION↗

A rapid heating and high magnetic field thermal analysis technique

Abstract A new thermal analysis technique is described that allows measurements to be performed on bulk samples at extreme heating and cooling rates and in high magnetic fields. High heating rates, up to 1000 °C min −1 , are achieved through electromagnetic induction heating of a custom-built apparatus fitted with commercial thermal analysis heads and sensor. Rapid cooling rates, up to 100 °C min −1 , are enabled by gas quenching and the small thermal mass of the induction furnace. The custom apparatus is designed to fit inside a superconducting magnet capable of fields up to 9 Tesla. This study demonstrates that the instrument is capable of collecting accurate thermal analysis data in high magnetic fields and rapidly acquiring data for dynamic processes. While the full potential of the technique is still unrealized, currently, it can provide insight into phenomena at time scales relevant to heat treatment in many industrial processes and into little understood effects of high magnetic field processing.

47 OTHER INSTRUMENTATION↗

Thermal properties of silicon nitride beams below 1 Kelvin.

We have investigated the thermal transport of long, narrow beams of silicon nitride at cryogenic temperatures. Simultaneously employing a superconducting Transition Edge Sensor (TES) as both a heater and a sensor, we measured the thermal conductance of 1 {micro}m thick silicon nitride beams of different lateral dimensions. Based upon these measurements, we calculate the thermal parameters of the beams. We utilize a boundary limited phonon scattering model and assume the phonon mean free path to be temperature independent in the calculation. In the temperature range from 300 mK to 530 mK, the following results are obtained for 20 (30) {micro}m beams: the volume heat capacity is 0.083 T+0.509 T{sup 3} J/m{sup 3}-K, the width dependent phonon mean free path is 9.60 (11.05) {micro}m, and the width dependent thermal conductivity is 5.60 x 10{sup -3} T+3.41 x 10{sup -2} T{sup 3} (6.50 x 10{sup -3} T+3.93 x 10{sup -2} T{sup 3}) W/m-K.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of platinum resistance thermometers

An evaluation procedure for the characterization of industrial platinum resistance thermometers (PRTs) for use in the temperature range -120 to 160 C was investigated. This evaluation procedure consisted of calibration, thermal stability and hysteresis testing of four surface measuring PRTs. Five different calibration schemes were investigated for these sensors. The IPTS-68 formulation produced the most accurate result, yielding average sensor systematic error of 0.02 C and random error of 0.1 C. The sensors were checked for thermal stability by successive and thermal cycling between room temperature, 160 C, and boiling point of nitrogen. All the PRTs suffered from instability and hysteresis. The applicability of the self-heating technique as an in situ method for checking the calibration of PRTs located inside wind tunnels was investigated.

Daryabeigi, Kamran↗

Overview of the Dragonfly Entry Aerosciences Measurements (DrEAM) Suite

NASA Ames and Langley arepartnering with DLR to propose acomprehensive instrumentation suite known as the Dragonfly Entry Aerosciences Meas-urements (DrEAM). DrEAM being the first competed mission to fly EDL instrumentation as part of NASA’s Engineering Science Investigation (ESI).DrEAM will provide key aerothermodynamicdata and performance analysisfor Dragonfly’s forebody and backshell therma lprotection system (TPS),and also includes a DLR-provided Data Acquisition System(DAS).Titan’s atmosphere predominantly consists of nitro-gen (~98% by mole) with small amounts of methane(~2% by mole)and other trace gases. CN is a strong ra-diator and is found in nonequilibriumconcentrationsfor Titan entry. The accurate modeling of nonequilibrium CN radiation has proven to be a difficult task. Prompted by the Huygensmission, many experimental campaigns and analyses were performed to better understand the aerothermal environments experience by the probe dur-ing Titan entry[1].However, the Huygens probe carried no heatshieldinstrumentation. Therefore,the DrEAM instrumentation suite will significantly advance the state-of-the-art not only by documenting theenviron-ment and performance of Dragonfly’sentry system but also by making keymeasurements in Titan’s atmos-phere for thefirst time, thus providing new benchmark dataapplicable to entry science more generally. Current Measurement Goals: Aerothermal envi-ronments and TPS responsewill be measured using sen-sors similarto the Mars Entry, Descent, and Landing In-strumentation2 (MEDLI2) Integrated Sensor Plug(MISP) and the COMbined Aerothermaland Radiome-ter Sensor (COMARS)suite[2], with the latter supplied by DLR.For MEDLI2, MISP usedembedded thermo-couples (TCs) todirectly measure in-depth temperature of theTPS at several locations,which can also be used to infer surface environmentsvia inverse analysis. For DrEAM, the MISPstyle plugswill be known as Drag-onfly Sensors for Aero-Thermal Reconstruction (Drag-STR)plugs. On Schiaparelli, the COMARSsuite in-cludedthree total surface-mounted heatflux sensors, three pressure sensors, and one radiometer. For DrEAM, the COMARS package will be known as COmbined Sensor System for Titan Atmosphere (COSSTA). Atmospheric density measurements and capsuleaerodynamic data will be obtained throughthe onboard Inertial Measurement Unit (IMU),supple-mented by pressure transducers similar tothose used by the MEDLI Mars Entry AtmosphericData System (MEADS).The DrEAM pressure sensors will be known as Dragonfly Atmospheric Flight Transducers(DrAFT) Both DragSTR and DrAFThave flight heritagefrom MISP and MEADS on the MSLand Mars 2020mis-sions, and the COMARS suite successfullyflew on the ESA Schiaparelli EDMlander. A preliminary layout of the sensors is shown in Fig. 1. Because Dragonflyuses the same aeroshell provider (i.e., LockheedMartin) and materials for the TPS,with what are expected to be sim-ilar thicknesses as MSL and Mars 2020on both the heat shield and backshell, theDrEAMinstrumentation will look to utilize the same techniques and processes as de-veloped byMEDLI and MEDLI2for vehicle integra-tion. This commonality alsoenables DrEAMto lever-age the extensiveground test qualifications performed forMEDLI and MEDLI2 and claim substantial heritagefor this system.

A Brandis↗

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗