At least 523 records · Page 29

Photovoltaic-assisted heat pump water heater system and method

A solar power system has a photovoltaic module that supplies electrical current derived from sunlight to a heater system of a hot water tank. The heater system uses the electrical energy from the photovoltaic module, and optionally also from a local power grid, to heat water up to a selected maximum stored hot water temperature. Control circuitry senses when the level of electrical power is below a threshold solar-power level, and in response sets the stored hot water temperature for the heater system to a first lower temperature value. The control circuitry also senses when the level of electrical power is above the threshold solar-power level, an in response sets the stored hot water temperature for the heater system to a second elevated temperature value higher than the lower temperature, making advantageous use of solar power when available. A mixing unit adds cold water to set the dispensed water temperature.

14 SOLAR ENERGY↗

Temperature Compensated Sapphire Resonator for Ultrastable Oscillator Operating at Temperatures Near 77 Deg Kelvin

A sapphire resonator for an ultrastable oscillator capable of substantial performance improvements over the best available crystal quartz oscillators in a compact cryogenic package is based on a compensation mechanism enabled by the difference between copper and sapphire thermal expansion coefficients for so tuning the resonator as to cancel the temperature variation of the sapphire's dielectric constant. The sapphire resonator consists of a sapphire ring separated into two parts with webs on the outer end of each to form two re-entrant parts which are separated by a copper post. The re-entrant parts are bonded to the post by indium solder for good thermal conductivity between parts of that subassembly which is supported on the base plate of a closed copper cylinder (rf shielding casing) by a thin stainless steel cylinder. A unit for temperature control is placed in the stainless steel cylinder and is connected to the subassembly of re-entrant parts and copper post by a layer of indium for good thermal conduction. In normal use, the rf shielding casing is placed in a vacuum tank which is in turn placed in a thermos flask of liquid nitrogen. The temperature regulator is controlled from outside the thermos flask to a temperature in a range of about 40K to 150K, such as 87K for the WGH-811, mode of resonance in response to microwave energy inserted into the rf shielding casing through a port from an outside source.

Dick, G. John↗

Effect of Residual Noncondensables on Pressurization and Pressure Control of a Zero-Boil-Off Tank in Microgravity

The Zero-Boil-Off Tank (ZBOT) Experiment is a small-scale experiment that uses a transparent ventless Dewar and a transparent simulant phase-change fluid to study sealed tank pressurization and pressure control with applications to on-surface and in-orbit storage of propellant cryogens. The experiment will be carried out under microgravity conditions aboard the International Space Station in the 2014 timeframe. This paper presents preliminary results from ZBOT's ground-based research that focuses on the effects of residual noncondensable gases in the ullage on both pressurization and pressure reduction trends in the sealed Dewar. Tank pressurization is accomplished through heating of the test cell wall in the wetted and un-wetted regions simultaneously or separately. Pressure control is established through mixing and destratification of the bulk liquid using a temperature controlled forced jet flow with different degrees of liquid jet subcooling. A Two-Dimensional axisymmetric two-phase CFD model for tank pressurization and pressure control is also presented. Numerical prediction of the model are compared to experimental 1g results to both validate the model and also indicate the effect of the noncondensable gas on evolution of pressure and temperature distributions in the ullage during pressurization and pressure control. Microgravity simulations case studies are also performed using the validated model to underscore and delineate the profound effect of the noncondensables on condensation rates and interfacial temperature distributions with serious implications for tank pressure control in reduced gravity.

Marangoni and Natural Convection↗

A comparison of closed loop thermionic reactor control schemes.

The dynamics of the constant-voltage and constant-emitter-temperature control schemes are described. The closed loop responses to load changes, converter failures and reactivity perturbations are shown. Both control schemes inherently allow load voltages to vary during transients. An alternative control scheme is proposed which allows constant load voltage while preserving constant emitter temperatures.

Sawyer, C. D.↗

Thermal test results of the two-phase thermal bus technology demonstration loop

A two-phase heat transport system, the Thermal Bus Technology Demonstrator, has been built and tested for NASA Johnson Space Center for application on Space Station. The loop is a separated two-phase system that uses evaporator flow control valves and liquid condenser flooding to achieve temperature control. Both ambient and thermal vacuum tests have been completed in NASA's Chamber A, initially using Freon-11 and then ammonia as the working fluid. Overall, the tests were quite successful, with the bus achieving all major test objectives, including operation at 19.5 kW and set points at 35 F (1.7 C), 70 F (21.1 C) and 104 F (40.0 C), load sharing, asymmetrical heating and isothermality around the loop. Low plate to vapor temperature drops were obtained for the monogroove cold plate using ammonia and are indicative of the high evaporative film coefficients obtainable with this design.

Edelstein, Fred↗

Waste Chemistry Envelope for the Determination of Pitting Corrosion Susceptibility - 19554

Liquid radioactive wastes at the Hanford and Savannah River sites are stored in large underground carbon steel tanks. The high-level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks, will be required to be in service for times exceeding the initial intended life (i.e., greater than 60 years). Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. Administrative programs are in place to mitigate potential corrosion mechanisms and thereby maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. Waste chemistry and temperature control are the means by which corrosion degradation of the waste tanks is minimized. Chemistry controls are based on in-situ coupon tests, waste tank experience, and laboratory testing. These requirements comprise the technical standards for corrosion control. The standards are utilized then as guidelines for operational procedures. The present waste chemistry controls for the Hanford DSTs were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the DOE Savannah River Site (SRS). Portions of the SRS chemistry limits, which were developed at the Savannah River National Laboratory (SRNL) were coupled with corrosion testing results from Pacific Northwest National Laboratories (PNNL) and adopted for corrosion control of the double-shell tank (DST) waste at the Hanford Site. Since that time, the temperatures of the waste in the DSTs have decreased to less than 50 deg. C in most cases as the radioactive material has decayed. As a consequence, new chemistry controls were formulated for SCC in 2010. This testing however, did not address that potential for pitting in the supernatant and at the liquid-air interface. Indeed, initial tests indicated that the inhibitor requirements for SCC would be insufficient for the prevention of pitting. In addition to lower waste temperatures, future retrieval and process changes may impact the DST waste chemistry. Initial projections suggest that the waste chemistry of the DSTs may shift to a broader range of pH and higher aggressive anion concentrations (e.g., chloride, sulfate, etc.) than the wastes that are presently stored. Additionally, processes within the vitrification facility may result in streams that are returned to the tank farm for evaporation. These streams may also contain high concentrations of aggressive species. SRNL investigated the propensity for pitting of the carbon steel waste tanks at current and projected DST waste chemistries. A statistically designed series of tests provided a pitting factor that relates the ratio of the inhibitor species to the aggressive species and the probability of observing pitting. An acceptable pitting factor was determined and was utilized for the development of a new chemistry envelope. The new chemistry envelope was compared to the envelope that was established for SCC and was determined to be bounding. Validation of the new chemistry envelope was performed via model simulations and comparison with historical experimental results and approaches to establishing chemistry envelopes. The new chemistry envelope will eventually be part of an overall assessment of the condition of the tanks and any changes made to the overall structural integrity program for the Hanford DSTs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Turbine gas temperature measurement and control system

A fluidic Turbine Inlet Gas Temperature (TIGIT) Measurement and Control System was developed for use on a Pratt and Whitney Aircraft J58 engine. Based on engine operating requirements, criteria for high temperature materials selection, system design, and system performance were established. To minimize development and operational risk, the TIGT control system was designed to interface with an existing Exhaust Gas Temperature (EGT) Trim System and thereby modulate steady-state fuel flow to maintain a desired TIGT level. Extensive component and system testing was conducted including heated (2300F) vibration tests for the fluidic sensor and gas sampling probe, temperature and vibration tests on the system electronics, burner rig testing of the TIGT measurement system, and in excess of 100 hours of system testing on a J58 engine. (Modified author abstract)

Webb, W. L.↗

Mission Performance of the GLAS Thermal Control System - 7 Years In Orbit

ICESat (Ice, Cloud and land Elevation Satellite) was launched in 2003 carrying a single science instrument - the Geoscience Laser Altimeter System (GLAS). Its primary mission was to measure polar ice thickness. The GLAS thermal control architecture utilized propylene Loop Heat Pipe (LHP) technology to provide selectable and stable temperature control for the lasers and other electronics over a widely varying mission thermal environment. To minimize expected degradation of the radiators, Optical Solar Reflectors (OSRs) were used for both LHP radiators to minimize degradation caused by UV exposure in the various spacecraft attitudes necessary throughout the mission. Developed as a Class C mission, with selective redundancy, the thermal architecture was single st ring, except for temperature sensors used for heater control during normal operations. Although originally planned for continuous laser operations over the nominal three year science mission, laser anomalies limited operations to discrete measurement campaigns repeated throughout the year. For trending of the science data, these periods were selected to occur at approximately the same time each year, which resulted in operations during similar attitudes and beta angles. Despite the laser life issues, the LHPs have operated nearly continuously over this time, being non-operational for only brief periods. Using mission telemetry, this paper looks at the performance of the thermal subsystem during these periods and provides an assessment of radiator degradation over the mission lifetime.

Grob, Eric W.↗

Quantitative Characterization of Impacts of Coupled Geomechanics and Flow on Safe and Permanent Geological Storage of CO 2 in Fractured Aquifers

This is the final scientific report for the award DE-FE0023305, entitled “Quantitative Characterization of Impacts of Coupled Geomechanics and Flow on Safe and Permanent Geological Storage of CO 2 in Fractured Aquifers.” The work has been divided into six tasks. In Task 2, we characterized rock properties, which are important when developing a quantitative approach for understanding and predicting geomechanical effects on large-scale CO 2 injection and long-term storage in the subsurface. Rock properties of interest for this characterization include porosity, permeability, elastic constants, strength, and heat capacity. We measured rock properties for three different rock types: concrete, sandstone and shale. These properties were obtained from the acoustic measurement, permeability and porosity measurement, Brazilian test, the uniaxial compressive test, and heat capacity measurement. Then, using the Brazilian technique to fracture samples, we measured their permeability under brine injection for varying effective stresses, followed by similar measurements of permeability under sc-CO 2 injection. Permeability to brine and sc-CO 2 decreased as the effective stress increased. The apparent permeability to sc-CO 2 was an order of magnitude less than that for brine, a consequence of CO 2 being the non-wetting fluid. In Task 3, we developed understandings and correlations for CO 2 injection pressure induced fracturing. We initially fractured four eight inch cubes of concrete with brine to establish a standard test procedure. Then, additional concrete samples were fractured using brine. Confining stresses were exerted on the samples and brine was injected at a constant rate into a borehole that was previously drilled into the concrete cube. The borehole pressure was measured and fracture initiation was identified as a peak in the pressure profile. That was followed by fracture propagation, which was identified as a plateau in the pressure profile, and finally the fracture reached the sample surface. The sample surfaces were photographed before and after fracturing, which enabled determination of where the fracture reached the sample surface. Afterwards, aqueous food dye solution was injected into the fractured concrete samples to color the fracture planes. The borehole was filled with food dye solution in advance, a gas pulse was transmitted to the borehole, and the borehole was then shut in to allow the food dye to be driven into existing fractures. Then, the concrete samples were broken down by high-pressure gas injection to reveal the geometry and morphology of the hydraulic fractures. In addition, acoustic measurements were conducted on multiple locations on each face of the concrete samples before and after injection for comparison. This comparison was used to confirm changes in the internal structure of the concrete sample, namely the formation of fractures. There were six concrete samples fractured with brine. Afterwards, concrete samples were fracture using sc-CO 2 . The main change in experimental procedure was the inclusion of temperature control, since in the field, we mostly encounter temperature and pressure conditions above the supercritical point of CO 2 . The concrete samples were pre-heated in an oven to elevate their temperature, and thermal tape was used to heat the CO 2 to a temperature above its supercritical temperature. Two concrete samples were fractured using liquid CO 2 , four concrete samples were fractured using gaseous CO 2 , and twenty two concrete samples were fractured using sc-CO 2 . For the concrete samples fractured using sc-CO 2 , three had pre-existing hydraulic fractures on the surface near the wellbore, and two were water saturated (as opposed to containing only air). Two concrete samples were composite samples, with a high permeability ball in the center, in order to represent CO 2 injection into a high permeability zone surrounded by a low permeability sealing formation. Later, we fractured five shale samples, obtained from the Niobrara shale outcrop, with sc-CO 2 . The injection rate was constant, confining stresses were applied, the shale samples were pre-heated in an oven to the desired temperature, and the sample was then fractured. An analysis of the failure type was done for many of the concrete samples, based on the predicted break down pressure for tensile and shear failure, and it was found that most samples fractured due to shear failure. Also, the presence of induced fractures has little to no effect on the fracture initiation pressure, but significantly changes the fracture morphology. The CO 2 fracturing in water saturated samples behaved much similar to brine induced fracturing. There was a significant difference of breakdown pressure for injection of CO 2 and brine, where the breakdown pressure for CO 2 induced fracturing is generally around the minimum horizontal stress and that for brine is much higher. Finally, the fracture orientation for most samples with large confining stress differential was perpendicular to the minimum horizontal stress. When the stress differential, especially the difference between the two directions with the smallest stresses was small, the fracture orientation was determined not only by the minimum stress direction, but also the magnitude of the confining stress, the tensile strength of the rock, and the breakdown pressure. In Task 4, we modified our coupled flow-geomechanical models to model fracture growth and propagation in storage formations and caprocks. These flow-geomechanical models are TOUGH2-CSM and TOUGH2-FLAC. The TOUGH2-CSM fluid and heat flow formulation is based on the TOUGH2 formulation of mass and energy conservation equations that govern fluid and heat flow in general multiphase, multicomponent, multi-porosity systems. The TOUGH2-CSM simplified geomechanical formulation is based on the linear theory of elasticity applied to multi-porosity non-isothermal (thermo-multi-poroelastic) media. We previously derived, from the fundamental relations of the linear theory of elasticity, an equation relating mean stress, pore pressures, temperatures, and body force (the Mean Stress equation) that we added to the TOUGH2-CSM fluid and heat flow equations. We extended the TOUGH2-CSM simplified geomechanical formulation to calculate the entire stress tensor by deriving equations for stress tensor components from derivatives of the Cartesian thermo-multi-poroelastic Navier equation components. In addition, we derived equations for stress tensor components in rz-coordinates. We solved these geomechanical equations using the integral finite difference method. This method utilizes momentum fluxes obtained by “factoring” a divergence operator out of each geomechanical equation. In Task 5, we did a literature survey to determine suitable correlations for fracture initiation, growth, and propagation. After surveying numerous papers, we modified TOUGH2-CSM to model stress dependent fracture initiation and growth using the Mohr-Coulomb criterion for shear failure in faults and caprock and the condition of negative minimum effective stress for tensile failure. Tensile failure results in a fracture whose width depends on the difference between fracture pressure and minimum stress and whose propagation is based on the difference between the stress intensity factor at the fracture tip and the rock toughness. The TOUGH-FLAC model is based on the FLAC3D ubiquitous joint model, extended for the modeling of permeability changes induced by changes in effective normal stress across fractures as well permeability changes caused by shearing along fractures. In Task 6, we validated our coupled flow-geomechanical models using analytical solutions and problems from the literature. We validated the TOUGH2-CSM modifications using analytical solutions to the displacement from a uniform load on a semi-infinite elastic medium and the two-dimensional Mandel-Cryer effect. Those were followed by a sample problem to test our stress tensor calculations, which was for injection into a single-phase reservoir with constant properties. Comparisons of our simulator to published results were done on for the depletion of a single-phase reservoir with stress dependent porosity, two examples from the In Salah gas project, an axisymmetric baserock–reservoir–caprock system with a normal faulting stress regime that had thermally induced shear stresses, simulations of CO 2 leakage through caprock in a two-dimensional reservoir in Cartesian coordinates, and predictions of caprock failure from CO 2 injection into an axisymmetric reservoir. Finally, we simulated CO 2 injection pressure-induced fracturing from one of our laboratory studies, Sample 39, and obtained a fracture profile. We also validated the TOUGH2-FLAC model for fluid driven fracture growth against solutions based on the KGD model and a case with an inclined fracture that was loaded from the boundaries to achieve wing-crack propagation. The strain softening tensile behavior and softening of modulus considering a simple damage approach was verified by a simulation representing hydraulic fracturing stress measurement around a vertical well. Finally, the model was validated against deep fracture zone opening and surface uplift at In Salah with inverses analysis used to improve the match of simulation with field data. In Task 7, we developed a scheme based on inverse modeling that can be used to identify caprock leakage. Injection of fluid into a reservoir results in a time varying pressure profile that depends on the properties of the rock and the fluid. The presence of significant caprock leakage would effect this pressure profile and we used inverse modeling, namely the Levenberg-Marquardt method, to determine the leakage location from the pressure profile. A two-dimensional and a three-dimensional example based on published data were presented. The published simulation was run and its results were considered as “field” data. In the two-dimensional example, a simulation of CO 2 injection into a two-dimensional aquifer-caprock system, the caprock had a vertical fault through which leakage could occur. The location of this leakage was obtained from our inverse modeling scheme. In the three-dimensional example, the simulation domain had four geological layers, one of which was the injection zone that contained a horizontal injection well. We simulated fractures as high permeability gridblocks, introduced a fracture that spanned the caprock depth, and ran a simulation to obtain “field” data. Then, using our inverse modeling scheme, we obtained the location of that fracture.

58 GEOSCIENCES↗

System accurately controls pressure in cryogenic tanks

High-resolution differential pressure transducer senses very small positive or negative pressure variations in the cryogenic tank relative to absolute reference pressure. System is useful in calibrating instruments where working fluid must be maintained at closely controlled temperature, or in processes requiring very fine pressure control.

Kirchmeier, W. E., Jr.↗

Thermal analysis system /TAS-1/ program

Digital computer program develops temperature control system which maintains various subsystems within proper temperature limits. Coding is simple and input rules are easy to use and remember. Output format is easy to understand and to analyze for error diagnosis.

Hultberg, J. A.↗

Thermal control systems for low temperature Shuttle payloads

Greater sensitivity and longer life for future space sensor systems place more stringent demands on cooling system technology. Results are presented for a study designed to determine and evaluate low-temperature thermal control system concepts for various cooling categories in the range 3-200 K and to generate hardware development plans for undeveloped viable system concepts. The study considered Shuttle launched payloads in the 1980-1991 time frame, with 1-5 yr of life. Cooling concepts are categorized as open-cycle (expendable), closed-cycle (mechanical), solid-state, and radiative. Particular attention is given to the concepts of multistage heat pipe radiator, diode heat pipe radiator, and radiator guarded cryostat. Results are given for parametric analyses of the Vuilleumier refrigerator, the rotary reciprocating refrigerator, the solid hydrogen refrigerator, the solid hydrogen/multistage radiator hybrid cooler, and the magneto-Peltier hybrid cooler.

Wright, J. P.↗

Thermal compensator for helium refrigerators

Closed-cycle helium refrigerator sensor generates negative-feedback control signals that drive heating diode to maintain temperature stability. Temperature-sensing diode and heating diode are mounted on heat sink that provides conductive path between load and cold tip. Method is applicable to other temperature-control applications, such as laser equipment, electronic instruments, and computer systems.

Hillman, J. J.↗

Commercial use of materials processing in space

The paper examines the scientific and commercial aspects of Materials Processing in the Space program. The elimination of gravity driven convection in molten materials can preclude undesirable stirring and mixing during crystal growth, and improve the casting of alloys and composites, chemical reactions, and the separation of biological materials. The elimination of hydrostatic pressure will allow alloy heat-treatment without distortion and growth of heavy crystals, such as thorium oxide, and containerless processing of liquids and molten materials. On the other hand, more sophisticated process control and diagnostic methods in sample preparation and temperature control must be developed, concluding that space made products of commercial interest are likely to be low volume, high value items.

Zoller, L. K.↗

Geoscience Laser Altimetry System (GLAS) On-Orbit Flight Report on the Propylene Loop Heat Pipes (LHPs)

The Geoscience Laser Altimetry System (GLAS) instrument which is the sole instrument on ICESat was launched on January 12, 2003. GLAS utilizes two actively controlled propylene Loop Heat Pipes (LHPs) as the core of its thermal system. The LHPs started quickly when the Dale Ohm starter heaters were powered and have as designed. The low control heater power and on-orbit tight temperature control appear independent of gravity effects when comparing ground testing to flight data. The use of coupling blocks was also unique to these LHPs. Their application reduced control heater power by reducing the subcooling from the radiator. The effectiveness in reducing subcooling of the coupler blocks decreased during flight from ground testing, but internal thermal isolation in the compensation chamber between the subcooled returning liquid increased in flight resulting in no net increase in control heater power versus ground measurements. Overall the application of LHPs in the thermal system for GLAS met instrument requirements and provided flexibility for the overall system as last minute requirements became known.

Baker, Charles L.↗

Device and method for measuring thermal conductivity of thin films

A device and method are provided for measuring the thermal conductivity of rigid or flexible, homogeneous or heterogeneous, thin films between 50 .mu.m and 150 .mu.m thick with relative standard deviations of less than five percent. The specimen is sandwiched between like material, highly conductive upper and lower slabs. Each slab is instrumented with six thermocouples embedded within the slab and flush with their corresponding surfaces. A heat source heats the lower slab and a heat sink cools the upper slab. The heat sink also provides sufficient contact pressure onto the specimen. Testing is performed within a vacuum environment (bell-jar) between 10.sup.-3 to 10.sup.-6 Torr. An anti-radiant shield on the interior surface of the bell-jar is used to avoid radiation heat losses. Insulation is placed adjacent to the heat source and adjacent to the heat sink to prevent conduction losses. A temperature controlled water circulator circulates water from a constant temperature bath through the heat sink. Fourier's one-dimensional law of heat conduction is the governing equation. Data, including temperatures, are measured with a multi-channel data acquisition system. On-line computer processing is used for thermal conductivity calculations.

Amer, Tahani R.↗

Temperature Stability and Control Requirements for Thermal Vacuum/Thermal Balance Testing of the Aquarius Radiometer

The paper describes the specific temperature stability and control requirements for the thermal vacuum and thermal balance testing of the Aquarius Instrument at the Goddard Space Flight Center in Greenbelt, Maryland. The testing was conducted in the 10' wide x 15' deep Facility 225 Thermal Vacuum chamber. The temperature control stability requirements were less than .14 C RMS thermal variation over a seven-day period. The thermal test specification also called for the ability to impose a high-resolution sinusoidal variation for all heater zones. The special requirements of the Aquarius radiometer test necessitated the construction of a multi-function test fixture and the modification of two existing heater controller racks.

Johnson, Chris↗