Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIMING PROPERTIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Plasma formation in a double-gap vircator

Time-resolved light emission imaging was used to observe the plasma formation within the cavity of the double-gap vircator powered by a sub-microsecond generator ({approx}500 kV, {approx}10 kA, {approx}500 ns). The vircator generated well reproducible S-band microwave pulses of {approx}200 MW peak power and up to 200 ns full duration. The plasma light emission was observed {approx}30 ns prior to the ending of the generated microwave pulses at the surface of the aluminum foil separating the vircator cavity gaps, in the gap where the virtual cathode is formed. Estimations showed that the energy deposition into the foil by the high-current electron beam is sufficient for the surface plasma formation. The plasma ions accelerated toward the virtual cathode neutralize its electron space charge. The latter was confirmed by the increase in the electron current transmitted through the vircator cavity. In addition, the time of the plasma appearance was determined by comparing the measured transmitted current with that following from the one-dimensional model of a stationary un-neutralized two-stream electron flow. This time agrees with the maximum of the microwave power observed in the experiments, thus showing that the plasma ions cause the termination of the microwave generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Semianalytic model of electron pulse propagation: Magnetic lenses and rf pulse compression cavities

The analytical Gaussian electron pulse propagation model of Michalik and Sipe [J. Appl. Phys. 99, 054908 (2006)] is extended to include the action of external forces on the pulse. The resultant ability to simulate efficiently the effect of electron optical elements (e.g., magnetic lenses and radio-frequency cavities) allows for the rapid assessment of electron pulse delivery systems in time-resolved ultrafast electron diffraction and microscopy experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Seeded FEL Microbunching Experiments at the UCLA Neptune Laboratory

Seeded high-gain FELs, which can generate very powerful radiation pulses in a relatively compact undulator and simultaneously modulate the electron beam longitudinally at the seed wavelength, are important tools for advanced accelerator development. A single-pass 0.5-9 THz FEL amplifier-buncher driven by a regular photoinjector is being built at the UCLA Neptune Laboratory. FEL interactions at 340 {mu}m (1 THz) are considered for the first experiment, since time-resolved measurements of longitudinal current distribution of the bunched beam using the RF deflecting cavity are possible. A design of a 0.2-2.0 {mu}m FEL using the same undulators is presented. In this case the FEL is driven by a high-peak current beam from the laser-plasma accelerator tunable in the 100-300 MeV range.

43 PARTICLE ACCELERATORS↗

Four-dimensional imaging of the initial stage of fast evolving plasmas

Using an ultrafast electron probe capable of four-dimensional diagnosis, the initial stage of fast evolving plasmas produced by a 10{sup 14} W/cm{sup 2} laser irradiation of a metal target was investigated in real time with picosecond time resolution. The associated strong transient electric field was identified to have two components, which either focus or defocus the probe electron beam. The effects of this field on the probe electron beam can be reproduced by a self-expanding charge cloud containing about 5x10{sup 7} suprathermal electrons with the outermost layer expanding at an average speed of 1.2x10{sup 7} m/s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photodissociation of thioglycolic acid studied by femtosecond time-resolved transient absorption spectroscopy

Steady-state and time-resolved spectroscopies were employed to study the photodissociation of both the neutral (HS-CH{sub 2}-COOH) and doubly deprotonated ({sup -}S-CH{sub 2}-COO{sup -}) forms of thioglycolic acid (TGA), a common surface-passivating ligand used in the aqueous synthesis and organization of semiconducting nanostructures. Room temperature UV-Vis absorption spectroscopy indicated strong absorption by the S{sub 1} and S{sub 2} excited states at 250 nm and 185 nm, respectively. The spectrum also contained a weaker absorption band that extended to approximately 550 nm, which was assigned to the {pi}{sub CO}{sup *}(leftarrow)n{sub O} transition. Femtosecond time-resolved transient absorption spectroscopy was performed on TGA using 400 nm excitation and a white-light continuum probe to provide the temporally and spectrally resolved data. Both forms of TGA underwent a photoinduced dissociation from the excited state to form an {alpha}-thiol-substituted acyl radical ({alpha}-TAR, S-CH{sub 2}-CO). For the acidic form of TGA, radical formation occurred with an apparent time constant of 60 {+-} 5 fs; subsequent unimolecular decay took 400 {+-} 60 fs. Similar kinetics were observed for the deprotonated form of TGA (70 {+-} 10 fs radical formation; 420 {+-} 40 fs decay). The production of the {alpha}-TAR was corroborated by the observation of its characteristic optical absorption. Time-resolved data indicated that the photoinduced dissociation of TGA via cleavage of the C-OH bond occurred rapidly ({<=}100 fs). The prevalence of TGA in aqueous semiconducting nanoparticles makes its absorption in the visible spectral region and subsequent dissociation key to understanding the behavior of nanoscale systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thicker, more efficient superconducting strip-line detectors for high throughput macromolecules analysis

Fast detectors with large area are required in time-of-flight mass spectrometers for high throughput analysis of biological molecules. We fabricated and characterized subnanosecond 1x1 mm{sup 2} NbN superconducting strip-line detectors. The influence of the strip-line thickness on the temporal characteristics and efficiency of the detector for the impacts of keV accelerated molecules is investigated. We find that the increase of thickness improves both efficiency and response time. In the thicker sample we achieved a rise time of 380 ps, a fall time of 1.38 ns, and a higher count rate. The physics involved in this behavior is investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photoelectron angular distributions from autoionizing 4s{sup 1}4p{sup 6}6p{sup 1} states in atomic krypton probed with femtosecond time resolution

Photoelectron angular distributions (PADs) are obtained for a pair of 4s{sup 1}4p{sup 6}6p{sup 1} (a singlet and a triplet) autoionizing states in atomic krypton. A high-order harmonic pulse is used to excite the pair of states and a time-delayed 801 nm ionization pulse probes the PADs to the final 4s{sup 1}4p{sup 6} continuum with femtosecond time resolution. The ejected electrons are detected with velocity map imaging to retrieve the time-resolved photoelectron spectrum and PADs. The PAD for the triplet state is inherently separable by virtue of its longer autoionization lifetime. Measuring the total signal over time allows for the PADs to be extracted for both the singlet state and the triplet state. Anisotropy parameters for the triplet state are measured to be {beta}{sub 2}= 0.55 {+-} 0.17 and {beta}{sub 4}=-0.01 {+-} 0.10, while the singlet state yields {beta}{sub 2}= 2.19 {+-} 0.18 and {beta}{sub 4}= 1.84 {+-} 0.14. For the singlet state, the ratio of radial transition dipole matrix elements, X, of outgoing S to D partial waves and total phase shift difference between these waves, {Delta}, are determined to be X= 0.56 {+-} 0.08 and {Delta}= 2.19 {+-} 0.11 rad. The continuum quantum defect difference between the S and D electron partial waves is determined to be -0.15 {+-} 0.03 for the singlet state. Based on previous analyses, the triplet state is expected to have anisotropy parameters independent of electron kinetic energy and equal to {beta}{sub 2}= 5/7 and {beta}{sub 4}=-12/7. Deviations from the predicted values are thought to be a result of state mixing by spin-orbit and configuration interactions in the intermediate and final states; theoretical calculations are required to quantify these effects.

74 ATOMIC AND MOLECULAR PHYSICS↗

Time-resolved shadowgraphic study of femtosecond laser ablation of aluminum under different ambient air pressures

Femtosecond pulse laser ablation of aluminum under different ambient air pressures between 1 atm and 4 x 10{sup -4} Pa is investigated using a femtosecond time-resolved shadowgraphic method. It is observed that as the ambient air pressure decreases, the contact front becomes more and more distinct for a certain pressure range, demonstrating that the confinement effect of the ambient air to the ablated target material can play a critically important role in the laser ablation process. It is also found that the concentric and semicircular stripe pattern, which results from the diffraction of the probe beam by the expanding plume of a specific material state and is typically observed in the shadowgraphs for 1-2 ns delay time, gradually blurs and disappears while the ambient air pressure decreases from 1 atm to 7000 Pa. If a prepulse or a relatively large pulse pedestal exists before the main pulse, however, the stripe pattern can still be observed even though the ambient air pressure is 5 x 10{sup -4} Pa. It is thus inferred that what contributes to the formation of the unique stripe pattern is a mixture of the ejected target material and ionized background gas induced by the femtosecond laser ablation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of electron solvation in I{sup -}(CH{sub 3}OH){sub n} clusters (4 {<=}n{<=} 11)

The dynamics of electron solvation following excitation of the charge-transfer-to-solvent precursor state in iodide-doped methanol clusters, I{sup -}(CH{sub 3}OH){sub n=4-11}, are studied with time-resolved photoelectron imaging. This excitation produces a I{sup ...}(CH{sub 3}OH){sub n}{sup -} cluster that is unstable with respect to electron autodetachment and whose autodetachment lifetime increases monotonically from {approx}800 fs to 85 ps as n increases from 4 to 11. The vertical detachment energy (VDE) and width of the excited state feature in the photoelectron spectrum show complex time dependence during the lifetime of this state. The VDE decreases over the first 100-400 fs, then rises exponentially to a maximum with a {approx}1 ps time constant, and finally decreases by as much as 180 meV with timescales of 3-20 ps. The early dynamics are associated with electron transfer from the iodide to the methanol cluster, while the longer-time changes in VDE are attributed to solvent reordering, possibly in conjunction with ejection of neutral iodine from the cluster. Changes in the observed width of the spectrum largely follow those of the VDEs; the dynamics of both are attributed to the major rearrangement of the solvent cluster during relaxation. The relaxation dynamics are interpreted as a reorientation of at least one methanol molecule and the disruption and formation of the solvent network in order to accommodate the excess charge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space- and time-resolved characterization of nanosecond time scale discharge at pressurized gas

The phenomenon of ultra-fast electrical gas breakdown was investigated. Nanosecond high-voltage pulses with durations of 1 and 5 ns and amplitudes of 100 and 200 kV, respectively, were used to study the parameters of the discharge in a pressured (1-7) x 10{sup 5} Pa air-filled gap. The development of the discharge and the plasma propagation velocity was examined using optical fast frame imaging. The generation of runaway electrons in the breakdown process was confirmed by electron imaging and time-resolved x-ray diagnostics. Runaway electron beam energy distribution was obtained for a 1 ns duration high-voltage pulse. The origin and the role of runaway electrons in the discharge initiation are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energetic Ion Beam Production by a Low-Pressure Plasma Focus Discharge

Energetic ion beam emissions in a 3 kJ Mather type plasma focus operating at low-pressure regime are investigated. Deuterium gas is used and the discharge is operated in a low-pressure regime of below 1 mbar. Formation of the current sheath during the breakdown phase at the back wall is assisted by a set delayed trigger pulse. Energetic and intense ion beams with good reproducibility have been obtained for the operating pressure ranging from 0.05 mbar to 0.5 mbar. Deuteron beam is determined by time resolved measurement by making use of three biased ion collectors placed at the end on direction. The average energies of deuteron beams are resolved by using time-of flight method. Correlation between the ion emissions and the current sheath dynamics is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved gas temperature evolution in pulsed Ar-N{sub 2} microwave discharge

Temporal evolution of the gas temperature (T{sub g}) in a pulsed microwave surfaguide discharge is studied by measuring the N{sub 2} rotational temperature. We found that at high power applied per pulse, gas temperature grows linearly, and saturates after about 150 {mu}s. This effect is absent at low power values, or at short pulse durations. Observed T{sub g} behavior correlates with time-resolved measurements of the N{sub 2} vibrational temperature, as well as with N emission lines. Consequently, T{sub g} time behavior was related to N atoms production in plasma. Using obtained T{sub g} growth rates, the effective power used for plasma heating is determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Highly Efficient Neutron Veto Using Boron-Loaded Liquid Scintillator

By surrounding a dark matter detector with a layer of boron-loaded liquid scintillator, a highly efficient neutron veto can be produced. In Monte Carlo studies, a one meter thick layer of scintillator has a veto efficiency greater than 99.5% for nuclear recoil events induced by radiogenic neutrons, and a veto efficiency of more than 95% for nuclear recoil events produced by cosmogenic neutrons. The use of boron-loaded scintillator both reduces the veto-induced dead time by decreasing the neutron capture time and allows high neutron detection efficiency to be achieved in a relatively compact geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved resonant soft x-ray diffraction with free-electron lasers: Femtosecond dynamics across the Verwey transition in magnetite

Resonant soft x-ray diffraction (RSXD) with femtosecond (fs) time resolution is a powerful tool for disentangling the interplay between different degrees of freedom in strongly correlated electron materials. It allows addressing the coupling of particular degrees of freedom upon an external selective perturbation, e.g., by an optical or infrared laser pulse. Here, we report a time-resolved RSXD experiment from the prototypical correlated electron material magnetite using soft x-ray pulses from the free-electron laser FLASH in Hamburg. We observe ultrafast melting of the charge-orbital order leading to the formation of a transient phase, which has not been observed in equilibrium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-resolved photoelectron spectroscopy of coupled electron-nuclear motion

We investigate pump-probe electron detachment spectroscopy in a model system which is ideally suited to study coupled electronic and nuclear wave-packet dynamics. Time-resolved photoelectron spectra are calculated within the adiabatic approximation and a discretization of the detachment continuum. These spectra are compared to those which derive from a non-Born-Oppenheimer description and a numerically exact treatment of the detachment process. In this way it is possible to identify the influence of non-adiabatic effects on the spectra in a systematic way and also to test commonly applied approximations.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Electronics For The Versatile Array Of Neutron Detectors At Low Energies

A {chi}{sup 2} minimization algorithm has been developed to extract sub-sampling-time information from digitized waveforms, to be used to instrument the future Versatile Array of Neutron Detectors at Low energies. The algorithm performance has been characterized with a fast Arbitrary Function Generator, obtaining time resolution better than 1 ns for signals of amplitudes between 50 mV and 1V, with negligible walk in the whole range. The proof-of-principle measurement of the beta-delayed neutron emission from {sup 89}Br indicates a resolution of 1 ns can be achieved in realistic experimental conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗